Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Criticality Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Rossi-alpha Uncertainty Quantification by Analytic, Bootstrap, and Sample Methods to Inform Fitting Best Practices

The prompt neutron period (the negative reciprocal of the prompt neutron decay constant) can be estimated using the Rossi-alpha technique that is predicated on fitting Rossi alpha histograms and of interest in nuclear criticality safety and nonproliferation. The histograms are traditionally fit with a one-exponential model; however, recent work has proposed a two-exponential model to account for reflector induced phenomenon. Until recently, the uncertainty quantification for either model was inadequate (inaccurate and demanded large measurement times). Measurement uncertainty quantification by sample and analytic methods was developed and validated in Ref. The purpose of this transaction is to (i) validate a new bootstrap method by comparing bin-by-bin error bar estimates and (ii) demonstrate how to choose bin widths and reset times to optimize precision and accuracy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Guide for Using ENDF/B-VIII.0 Nuclear Data with MCNP

This report provides guidance for using the ENDF/B-VIII.0 nuclear data that were released in 2018 and 2020 with MCNP. Appendix A: Obtaining and installing the new ENDF/B-VIII.0 ACE nuclear data. Appendix B. Obtaining & using XSDIR files that include ENDF/B-VIII.0 data. Appendix C: ENDF/B-VIII.0-based ACE files for neutron cross-sections. A listing of the available temperatures and ZA numbers for neutron cross-sections (ACE files with suffix .nnC). Appendix D: ENDF/B-VIII.0-based ACE files for thermal scattering law (TSL) data, $S$(α,β). A listing of the available thermal scattering $S$(α,β) data (ACE files with suffix .nnT) The next section below provides guidance for modifying existing $\textit{mcnp}$ input files to use the ENDF/B-VIII.0 data. Detailed results from running several benchmark suites for nuclear criticality safety with both ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data are reported in. It is important to note that this report deals only with TSL data released in 2020. With the original release of ENDF/B-VIII.0 in 2018, the ACE files for neutron cross-sections were contained in a directory called Lib80X and the ACE files for TSL data were contained in a directory called ENDF80SaB. A few years later, it was determined that many of the TSL data files had been generated with faulty data or with incorrect processing, and a new set of ACE files for TSL data was created, with the corrected files contained in directory ENDF80SaB2.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automated Direct Perturbation Calculations with SCALE TSUNAMI [Abstract]

In nuclear criticality safety analysis, the sensitivity of the eigenvalue keff to uncertainties in nuclear data and its evaluation are crucial. The TSUNAMI sequences within the SCALE code system offer users various options with both multigroup (MG) and continuous-energy (CE) 3D Monte Carlo (MC) transport capabilities for calculating keff sensitivity coefficients and storing them in a sensitivity data file (SDF). Each methodology available in TSUNAMI offers distinct advantages and limitations, and its effectiveness can vary based on the specific problem being solved. As a best practice, practitioners typically use the direct perturbation (DP) method as a confirmatory step alongside their sensitivity calculations to verify the accuracy of the sensitivity data generated. In this process, DP calculations are usually performed on select nuclides, those considered most important for validating their total sensitivities. However, because of code limitations, analysts use a workaround method when conducting DP calculations for a single nuclide: rather than perturbing the nuclide's microscopic cross section, an equivalent number density for this nuclide is calculated to reflect the effect of a change in the macroscopic cross section due to a perturbation in the microscopic cross section. The current approach requires rerunning the CSAS criticality calculation several times with model changes. Although this method can yield results with acceptable accuracy, it is labor-intensive and prone to errors.

AZURE: SAMMY↗

Simulated Energy Response in a Multiplicity Detector

Neutron multiplicity analysis is used for many applications, including nonproliferation and criticality safety. Multiplicity detectors have advantages over total neutron counting as they provide the ability to assess both multiplication and mass in fissionable material. In addition, multiplicity detectors can generate real-time information, e.g., dose estimation. The ability to evaluate the detector efficiency in each application is of primary importance in producing meaningful analyses. Multiplicity detectors usually house 3 He tubes within a polyethylene moderator. If the tubes are located behind different thickness of polyethylene, they will have different energy responses. This paper assesses 3 He tube efficiency as a function of neutron energy for a specific multiplicity detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the 240 Pu(n,f) Prompt Fission Neutron Spectra with Chi-Nu

The DOE Nuclear Criticality Safety Program has funded a multi-year effort to measure the 240 Pu(n,f) Prompt Fission Neutron Spectrum at Chi-Nu. This project is a joint LANL-LLNL effort, involving the preparation of 12 240 Pu foils and construction of a Parallel-Plate Avalanche Counter at LLNL, with subsequent measurements of the 240 Pu(n,f) PFNS at the Chi-Nu beamline at the Los Alamos Neutron Science Center’s Weapons Neutron Research facility (LANSCE/WNR). We expect the PPAC to be ready in time to perform the measurements this run cycle.

240Pu Foils↗

Engagement opportunities in OECD NEA benchmark development

A myriad of opportunities is available to collaborate via international benchmark exercises and experimental data preservation activities. Many such opportunities abound under the auspices of the Nuclear Science Committee of the Organisation for Economic Co-operation and Development Nuclear Energy Agency (NEA). Key projects and activities of relevance to the development of advanced reactors design include the International Criticality Safety Benchmark Evaluation Project (ICSBEP), the International Reactor Physics Experiment Evaluation Project (IRPhEP), the International Assay Data of Spent Nuclear Fuel Database (SFCOMPO), the Shielding Integral Benchmark and Archive Database (SINBAD), and The International Experimental Thermal HYdraulicS Database (TIETHYS), and various cooperative benchmark exercises. Interested participants are encouraged to contact the leadership and secretariat of the various Technical Working Groups and Working Parties to become more engaged. This paper provides a summary of the current benchmark exercises and experimental databases available for international participation.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

ICSBEP Benchmarking Tutorial for DNCSH

As part of the DOE/NRC Collaboration for Criticality Safety Support for Commercial-Scale HALEU for Fuel Cycles and Transportation (DNCSH), a workshop was held on Teams on how to write a ICSBEP benchmark that meets modern standards. The workshop prepared people performing experiments and writing benchmarks so that they have an increased chance of submitting a benchmark that will be accepted. The workshop was led by experts from LANL, LLNL and Sandia.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Source Localization Using the NoMAD He-3 Detector [Slides]

With the goal of advancing criticality safety with neutron localization, the following tasks were successful: (1) demonstrated neutron source localization using a NoMAD detector and ML; and (2) developed a real-time system for streaming in data from NoMAD, verifying that the system works in experimental settings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Data Sensitivity/Uncertainty Studies of Tantalum-Reflected Systems

Tantalum (Ta) is a refractory metal with high melting point and high corrosion resistance. This makes it useful as a mold material for plutonium casting operations. Unfortunately, there are few criticality benchmarks with high nuclear data sensitivities. Given that, it is desirable to design new experiments to provide additional validation data for nuclear criticality safety, which is the objective of the Thales project. Multiple application models were used to represent process conditions (either normal conditions or credible upset conditions) both at Los Alamos National Laboratory (LANL) and Savannah River Site (SRS). A total of 40 application models were obtained. Given this, it was useful to down-select the number of needed application models. This work documents the down-selection based on several nuclear data sensitivity/uncertainty metrics. In addition to showing the result of the specific down-selection used for the Thales project, this work discusses potential ways to represent a large number of application models with a smaller number of proposed experiment designs.

42 ENGINEERING↗

CERBERUS: CEDT Phase-1 Preliminary Design for Cu Critical Experiment

The goal of the Critical Experiment Reflected By copper to bEtteR Understand Scattering [CERBERUS] is to design a critical experiment that maximizes sensitivities to Cu reactions, particularly in the intermediate energy region (0.625 eV – 100 keV). Despite the number of experiments evaluated in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook1, there is still a gap of benchmarks sensitive to neutrons in the intermediate energy region. Of the ICSBEP benchmarks sensitive to neutrons in the intermediate energy region, very few are also sensitive to Cu in that region. One of the primary intermediate energy benchmark evaluations is the ZEUS series, which uses a Cu reflector. However, concerns have been brought up about the nuclear data associated with Cu scattering in the reflector. Improving Cu nuclear data is important outside of the ZEUS series, because it is present in many bronze and aluminum alloys, which are used in various nuclear operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER-501 CED-3b: Experiment Execution Summary for the Pulsed-Neutron Die-Away Experimental Testbed for Thermal Scattering Law Benchmarks (PNDA)

This report summarizes the experiments done for IER-501, a testbed for pulsed-neutron die-away (PNDA) experiments at Lawrence Livermore National Laboratory (LLNL). The PNDA experiments were conducted in two separate two-day campaigns: one campaign for high-density polyethylene and another for Lucite. All experiments were performed at Lawrence Livermore Laboratory. They will become high-quality benchmarks that serve to optimize and validate thermal neutron scattering laws (TSLs), which are high priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). The report presents the PNDA design and its equipment, and it documents the experimental die-away curves. It presents the characterization measurements that have been performed to-date. Importantly, mass spectrometry measurements to determine sample impurities were not yet completed. These will be included in the final benchmark. The report gives the fitted decay constants for the die-away curves of each target sample. It also provides the data for the die-away curves in the appendices. The HDPE experiments examined twelve targets of varying size. The Lucite measurements included ten targets of varying size. Experimenters in the campaign were Daniel Siefman, William Zywiec, and Ruby Araj.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R -Matrix Analysis and Statistical Properties of Dysprosium Isotopes in the Neutron Energy Ranges Up To A Few Kev

In support of the Nuclear Criticality Safety Program, a set of evaluated resonance parameters was generated for seven dysprosium isotopes in the neutron energy range from thermal up to a few keV. The evaluation methodology used the Reich-Moore approximation to fit, with the R-matrix code SAMMY, the high-resolution capture and transmission measurements on natural and enriched samples recently performed at the Rensselaer Polytechnic Institute Gaerttner LINear ACcelerator facility. Additional transmission data measured on enriched samples by Liou at the Columbia University Nevis synchrocyclotron in the mid-seventies were used to gauge the neutron widths above 15 eV. Thermal constants such as absorption and (in)coherent scattering cross sections and corresponding scattering lengths were calibrated to the National Institute of Standards and Technology’s compilation except for 161,164 Dy isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluating 240 Pu Prompt Fission Neutron Spectra Including Chi-Nu Experimental Data

This report documents an evaluation of 240 Pu prompt fission neutron spectra (PFNS) including Chi-Nu experimental data. This work is a FY2025 Q4 NCSP (Nuclear Criticality Safety Program) milestone and named a “strategic priority”. This evaluation is new; it differs substantially from the most recent evaluation included in the ENDF/B library, which was for ENDF/B-VII.1 and then carried over unchanged to ENDF/B-VIII.1. The key difference between ENDF/B-VIII.1 and the new evaluation is that we have, for the first time, realistic experimental 240 Pu PFNS covering a broad incident and outgoing neutron energy range.

240Pu↗

Measurement uncertainty of rossi-alpha neutron experiments

Rossi-alpha neutron experiments are used to estimate the prompt neutron decay constant of a fissile assembly, a quantity of widespread interest in applications including in nuclear nonproliferation and criticality safety. This work develops a mathematical model to efficiently estimate measurement uncertainty of Rossi-alpha neutron experiments inferred from a two-exponential fit model with histogram binning. The derived uncertainty estimates were validated using repeated Rossi-alpha measurements of a subcritical, 4.5-kg sphere of weapons-grade, alpha-phase plutonium with nickel, copper, tungsten, and polyethylene reflectors. The estimates of uncertainty for the histogram data produced by the model were conservative and agree with the reference uncertainties within noise. The estimates of the prompt neutron decay constant uncertainty agreed with the reference uncertainties within one standard deviation. In conclusion, the proposed model will reduce total measurement times, ultimately reducing operational and procedural costs in application.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using the Criticality Accident Alarm System modeling capabilities in SCALE [Slides]

The following is a summary of advice for CAAS modeling in SCALE. Refer to the SCALE Criticality Safety and Radiation Shielding training slides or to the SCALE manual for exact syntax. Use a mesh for the fission source that is the most adequate for the problem to solve (coarse/fine). Don’t spend unnecessary resources; simplify the model if it does not impact the final results of interest. Be careful to deactivate secondary fissions in MAVRIC or the calculation may never end. Check that k eff and $\overline{\upsilon}$ calculated results are logical. Between KENO and MAVRIC, cross section libraries, materials, geometry, and mesh grid can be the same or different. Iterative calculations are usually complex problems that need variance reduction. It will be hard to find the best solving parameters in the first attempt; expert judgement is needed. Check each step separately. Use Fulcrum to visualize fission source, mesh source, and spatial/energy distributions to find potential errors or impactful imprecisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of the MUSIC 3 He Multiplicity Data

A measurement campaign called the Measurement of Uranium Subcritical and Critical (MUSiC) was performed on a range of configurations of highly-enriched uranium (HEU) from December 2020 through April of 2021. While part of the focus was to measure reactor kinetics parameters on delayed supercritical systems, an additional focus was performing neutron noise measurements on subcritical configurations from deeply subcritical to nearly delayed critical. Multiple detector systems were used to perform these measurements, such as a 3 He multiplicity detector called the Neutron Multiplicity Array Detector (NoMAD) and a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD). Also included were a scintillator system from the University of Michigan and a set of small 3He tubes that have previously been used to measure Rossi-α values on near-critical systems. The focus of this paper will be a comparison of prospective analysis methods for the NoMAD measurements. Previous subcritical measurements at the National Criticality Experiments Research Center (NCERC) submitted to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) used the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. This relies on the time correlations of neutron detections to infer the spontaneous fission rate and neutron multiplication of a system through binning the time tagged detections and analyzing resulting histograms of the numbers of counts. However, there are other neutron noise methods that rely on similar processes, such as the Hansen-Dowdy formalism which uses a slightly different methodology to extract multiplication from the neutron multiplicity counting moments. Comparisons can be made between these experimental results and those obtained through simulations to validate or identify deficiencies in analysis, detection methods, or the underlying nuclear data. Different time gating strategies and their effects on count rate uncertainties are also investigated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Procedure for Creating, Reviewing, and Submitting Input Files into the Benchmark Library

Los Alamos National Laboratory (LANL) has a number of criticality benchmark input files, modeled for use with MCNP, developed and maintained by various organizations including the Nuclear Criticality Safety (NCS) Division, XCP-3, and XCP-5. The purpose of this procedure is to standardize input file creation, review, and maintenance. This procedure incorporates existing practices used by IRSN as documented in the original report and the translation from French in addition to practices used by the LANL NCS Division as documented in. The report relates to input files used for the validation of the continuous energy Monte Carlo code MCNP6 but is general enough to be extended to other codes. This report describes the procedure on how to prepare and use benchmarks (taken mainly from the ICSBEP Handbook) for the validation of calculation routes. In particular, this report describes the procedure to follow in the creation of the input files and their integration in the experimental validation databases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AFRRI TRIGA Reactor Neutron and Gamma Dose Characterization Preliminary Results

Integral Experiment Request (IER) 484 is part of a series of dose characterization and nuclear accident dosimeter (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The Armed Forces Radiobilogy Research Institute (AFRRI) 1.1 MW Training, Research, Isotopes, General Atomics (TRIGA) Mark-F reactor is the third facility to undergo a dose study to establish reference dose values. A preliminary measurement was performed earlier this year, where a variety of foils were irradiated and activation gamma rays were measured using a high-purity germanium (HPGe) detector. The data was taken and analyzed to calculate the neutron spectrum in the irradiation facility. This paper will present preliminary results of the neutron dose measured. The characterization of the AFRRI dose field is planned in August.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗