Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Aircraft electric motor with integrated cooling system

Aircraft electric motors include a motor unit having a rotor and a stator. The stator includes a plurality of windings and cooling channels arranged to provide cooling thereto. A drive unit is configured to drive operation of the motor unit. A cooling system includes a working fluid arranged within a cooling fluid flow path, wherein the cooling fluid flow path includes a liquid cooling path configured to direct flow of the working fluid through, at least, the cooling channels of the motor unit and a vapor cooling path configured to direct flow of the working fluid through the drive unit and a separator arranged upstream of each of the liquid cooling path and the vapor cooling path and configured to direct a liquid portion of the working fluid into the liquid cooling path and configured to direct a vapor portion of the working fluid into the vapor cooling path.

Alahyari, Abbas A.↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Roof-integrated radiative air-cooling system to achieve cooler attic for building energy saving

The building attic usually subjects to substantial solar heat gain and has much higher temperature compared to the conditioned living space during the day, especially in summer and in hot areas. Reducing attic temperature can reduce cooling energy consumption in buildings. However, conventional techniques such as cool roof or attic ventilation, suffer from either heating penalty in winter or limited attic temperature reduction. In this work, a new roof-integrated radiative air-cooling system is introduced, which couples radiative sky cooling with attic ventilation to reduce attic temperature. A radiative air cooler with 1.08 m 2 surface area is constructed using a recently developed daytime radiative sky cooling metamaterial [Zhai et al., Science 355, pp. 1062–1066, 2017]. Experimental tests show that sub-ambient air cooling is achieved throughout 24-h day-and-night cycle in a summer day with clear sky conditions. Depending on air flow rates, measured sub-ambient temperature reductions of air are 5–8°C at night and 3–5°C at noon under direct sunlight, respectively. An in-house model is first developed for the radiative air-cooling system, the model is then coupled with EnergyPlus to study annual energy saving of buildings. The performance of the radiative air-cooling system is compared with three reference systems: shingle roof, attic ventilation, and cool roof. Results show that for a single-family house, attic temperature can be substantially reduced by 15.5–21.0°C, varying with attic insulation level, compared to shingle roof on typical summer days. Compared to a shingle roof (solar reflectance 0.25, thermal emittance 0.9) residential building with attic insulations of R-30 (RSI-5.28), R-10 (RSI-1.76), and R-0.8 (RSI-0.14), the roof-integrated radiative air-cooling system can achieve annual cooling energy savings of 0.4–1.5 kWh/m 2 (4.6–18.8%), 1.2–3.6 kWh/m 2 (10.2–41.4%), and 3.7–11.8 kWh/m 2 (26.5–76.1%) respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of cool roof and night ventilation in office buildings: A case study in Xiamen, China

Increasing roof albedo (using a “cool” roof) and night ventilation are passive cooling technologies that can reduce the cooling loads in buildings, but existing studies have not comprehensively explored the potential benefits of integrating these two technologies. This study combines an experiment in the summer and transition seasons with an annual simulation so as to evaluate the thermal performance, energy savings and thermal comfort improvement that could be obtained by coupling a cool roof with night ventilation. A holistic approach integrating sensitivity analysis and multi-objective optimization is developed to explore key design parameters (roof albedo, night ventilation air change rate, roof insulation level and internal thermal mass level) and optimal design options for the combined application of the cool roof and night ventilation. The proposed approach is validated and demonstrated through studies on a six-storey office building in Xiamen, a cooling-dominated city in southeast China. Simulations show that combining a cool roof with night ventilation can significantly decrease the annual cooling energy consumption by 27% compared to using a black roof without night ventilation and by 13% compared to using a cool roof without night ventilation. Roof albedo is the most influential parameter for both building energy performance and indoor thermal comfort. Optimal use of the cool roof and night ventilation can reduce the annual cooling energy use by 28% during occupied hours when air-conditioners are on and reduce the uncomfortable time slightly during occupied hours when air-conditioners are off.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cool core cycles: cold gas and AGN jet feedback in cluster cores

Using high-resolution 3D and 2D (axisymmetric) hydrodynamic simulations in spherical geometry, we study the evolution of cool cluster cores heated by feedback-driven bipolar active galactic nuclei (AGNs) jets. Condensation of cold gas, and the consequent enhanced accretion, is required for AGN feedback to balance radiative cooling with reasonable efficiencies, and to match the observed cool core properties. A feedback efficiency (mechanical luminosity ≈ ϵ M-dot {sub acc}c{sup 2}; where M-dot {sub acc} is the mass accretion rate at 1 kpc) as small as 6 × 10{sup −5} is sufficient to reduce the cooling/accretion rate by ∼10 compared to a pure cooling flow in clusters (with M{sub 200}≲7×10{sup 14} M{sub ⊙}). This value is much smaller compared to the ones considered earlier, and is consistent with the jet efficiency and the fact that only a small fraction of gas at 1 kpc is accreted onto the supermassive black hole (SMBH). The feedback efficiency in earlier works was so high that the cluster core reached equilibrium in a hot state without much precipitation, unlike what is observed in cool-core clusters. We find hysteresis cycles in all our simulations with cold mode feedback: condensation of cold gas when the ratio of the cooling-time to the free-fall time (t{sub cool}/t{sub ff}) is ≲10 leads to a sudden enhancement in the accretion rate; a large accretion rate causes strong jets and overheating of the hot intracluster medium such that t{sub cool}/t{sub ff}>10; further condensation of cold gas is suppressed and the accretion rate falls, leading to slow cooling of the core and condensation of cold gas, restarting the cycle. Therefore, there is a spread in core properties, such as the jet power, accretion rate, for the same value of core entropy or t{sub cool}/t{sub ff}. A smaller number of cycles is observed for higher efficiencies and for lower mass halos because the core is overheated to a longer cooling time. The 3D simulations show the formation of a few-kpc scale, rotationally supported, massive (∼10{sup 11} M{sub ⊙}) cold gas torus. Since the torus gas is not accreted onto the SMBH, it is largely decoupled from the feedback cycle. The radially dominant cold gas (T < 5 × 10{sup 4} K; |v{sub r}|>|v{sub ϕ}|) consists of fast cold gas uplifted by AGN jets and freely infalling cold gas condensing out of the core. The radially dominant cold gas extends out to 25 kpc for the fiducial run (halo mass 7×10{sup 14} M{sub ⊙} and feedback efficiency 6 × 10{sup −5}), with the average mass inflow rate dominating the outflow rate by a factor of ≈2. We compare our simulation results with recent observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Sympathetic cooling of a mass-mismatched two-ion chain in a double-well trap potential

Sympathetic cooling of two-ion system, in which one is laser-cooled and the other is sympathetically cooled and their masses are mismatched, in a linear rf trap with a double-well potential is proposed. The double-well potential consists of two wells, and there is one ion in each well. The axial frequencies of the two wells and the spatial interval between them are experimentally controllable. By theoretical analysis, the normal modes of the small oscillations around the equilibrium are derived, and a measure of the sympathetic cooling rate is obtained. As a result, it is found that the sympathetic cooling rate is fast when the frequency of the axial motion of the sympathetically cooled ion is close to that of the laser-cooled ion. In the double-well potential, the sympathetic cooling rate of the ion species whose mass is much heavier or lighter than that of the laser-cooled ion can be fast. The sympathetic cooling rate of C{sub 60}{sup +} by the laser-cooled Ba{sup +} in the double-well potential is estimated to be about 80 times faster than in the conventional setup. The double-well potential may be made by the microfabricated electrode configuration or by the optical dipole force trap.

74 ATOMIC AND MOLECULAR PHYSICS↗

Geospatial Characterization of Low-Temperature Heating and Cooling Demand in the United States: Preprint

Geothermal resources at temperatures below 150 degrees C have great potential as energy sources for various direct-use applications including heating and cooling in residential and commercial buildings. This study geospatially quantifies U.S. heating and cooling demand in residential, commercial, and manufacturing sectors; heating demand in the agricultural sector; and cooling demand in data centers at the county level through end-use energy consumption, expenditure, and commissioned power analyses. Heating and cooling demand in the residential sector was estimated using energy consumption data obtained from the U.S. Energy Information Administration accounting for different U.S. climate zones. For commercial sector analysis, the end-use major fuel energy intensity at the census division level was disaggregated to the county level with respect to principal building activities. Heating and cooling demand analysis for the manufacturing sector was based on end-use energy consumption for direct-use total process categorized by the North America Industry Classification System. Fuel expenditures in the U.S. Department of Agriculture Farm Production Expenditures were examined for heating demand analysis in the agricultural sector, particularly for the greenhouse, nursery, and floriculture production category. Lastly, commissioned power for data centers in the United States were explored for cooling demand analysis. Results indicated a significant fraction of U.S. primary energy consumption is used for low-temperature heating and cooling applications. Heating and cooling demand in residential and commercial sectors is significantly affected by the number of housing units and climate zone designations, while heating and cooling demand in manufacturing and agricultural sectors and data centers are mainly dependent on the number of facilities and their locations. Maps were generated visualizing where heating and cooling demand is high and, overlain with geothermal resource maps, can indicate locations where geothermal energy can supply this heating and cooling demand.

cooling demand↗

Geospatial Characterization of Low-Temperature Heating and Cooling Demand in the United States

Geothermal resources at temperatures below 150 degrees C have great potential as energy sources for various direct-use applications including heating and cooling in residential and commercial buildings. This study geospatially quantifies U.S. heating and cooling demand in residential, commercial, and manufacturing sectors; heating demand in the agricultural sector; and cooling demand in data centers at the county level through end-use energy consumption, expenditure, and commissioned power analyses. Heating and cooling demand in the residential sector was estimated using energy consumption data obtained from the U.S. Energy Information Administration accounting for different U.S. climate zones. For commercial sector analysis, the end-use major fuel energy intensity at the census division level was disaggregated to the county level with respect to principal building activities. Heating and cooling demand analysis for the manufacturing sector was based on end-use energy consumption for direct-use total process categorized by the North America Industry Classification System. Fuel expenditures in the U.S. Department of Agriculture Farm Production Expenditures were examined for heating demand analysis in the agricultural sector, particularly for the greenhouse, nursery, and floriculture production category. Lastly, commissioned power for data centers in the United States were explored for cooling demand analysis. Results indicated a significant fraction of U.S. primary energy consumption is used for low-temperature heating and cooling applications. Heating and cooling demand in residential and commercial sectors is significantly affected by the number of housing units and climate zone designations, while heating and cooling demand in manufacturing and agricultural sectors and data centers are mainly dependent on the number of facilities and their locations. Maps were generated visualizing where heating and cooling demand is high and, overlain with geothermal resource maps, can indicate locations where geothermal energy can supply this heating and cooling demand.

cooling demand↗

A STUDY ON LEGIONELLA PNEUMOPHILA, WATER CHEMISTRY, AND ATMOSPHERIC CONDITIONS IN COOLING TOWERS AT THE SAVANNAH RIVER SITE

Legionnaires disease is a pneumonia caused by the inhalation of the bacterium Legionella pneumophila. The majority of illnesses have been associated with cooling towers since these devices can harbor and disseminate the bacterium in the aerosolized mist generated by these systems. Historically, Savannah River Site (SRS) cooling towers have had occurrences of elevated levels of Legionella in all seasons of the year and in patterns that are difficult to predict. Since elevated Legionella in cooling tower water are a potential health concern a question has been raised as to the best control methodology. In this work we analyze available chemical, biological, and atmospheric data to determine the best method or key parameter for control. The SRS 4Q Industrial Hygiene Manual, 4Q-1203, 1 - G Cooling Tower Operation and the SRNL Legionella Sampling Program, states that 'Participation in the SRNL Legionella Sampling Program is MANDATORY for all operating cooling towers'. The resulting reports include L. pneumophila concentration information in cells/L. L. pneumophila concentrations >10{sup 7} cells/L are considered elevated and unsafe so action must be taken to reduce these densities. These remedial actions typically include increase biocide addition or 'shocking'. Sometimes additional actions are required if the problem persists including increase tower maintenance (e.g. cleaning). Evaluation of 14 SRS cooling towers, seven water quality parameters, and five Legionella serogroups over a three-plus year time frame demonstrated that cooling tower water Legionella densities varied widely though out this time period. In fact there was no one common consistent significant variable across all towers. The significant factors that did show up most frequently were related to suspended particulates, conductivity, pH, and dissolved oxygen, not chlorine or bromine as might be expected. Analyses of atmospheric data showed that there were more frequent significant elevated Legionella concentrations when the dew point temperature was high--a summertime occurrence. However, analysis of the three years of Legionella monitoring data of the 14 different SRS Cooling Towers demonstrated that elevated concentrations are observed at all temperatures and seasons. The objective of this study is to evaluate the ecology of L. pneumophila including serogroups and population densities, chemical, and atmospheric data, on cooling towers at SRS to determine whether relationships exist among water chemistry, and atmospheric conditions. The goal is to more fully understand the conditions which inhibit or encourage L. pneumophila growth and supply this data and associated recommendations to SRS Cooling Tower personnel for improved management of operation. Hopefully this information could then be used to help control L. pneumophila growth more effectively in SRS cooling tower water.

54 ENVIRONMENTAL SCIENCES↗

Stochastic Cooling

Stochastic Cooling was invented by Simon van der Meer and was demonstrated at the CERN ISR and ICE (Initial Cooling Experiment). Operational systems were developed at Fermilab and CERN. A complete theory of cooling of unbunched beams was developed, and was applied at CERN and Fermilab. Several new and existing rings employ coasting beam cooling. Bunched beam cooling was demonstrated in ICE and has been observed in several rings designed for coasting beam cooling. High energy bunched beams have proven more difficult. Signal suppression was achieved in the Tevatron, though operational cooling was not pursued at Fermilab. Longitudinal cooling was achieved in the RHIC collider. More recently a vertical cooling system in RHIC cooled both transverse dimensions via betatron coupling.

43 PARTICLE ACCELERATORS↗

Cooling Strategies for Vane Leading Edges in a Syngas Environment Including Effects of Deposition and Turbulence

The Department of Energy has goals to move land based gas turbine systems to alternate fuels including coal derived synthetic gas and hydrogen. Coal is the most abundant energy resource in the US and in the world and it is economically advantageous to develop power systems which can use coal. Integrated gasification combined cycles are (IGCC) expected to allow the clean use of coal derived fuels while improving the ability to capture and sequester carbon dioxide. These cycles will need to maintain or increase turbine entry temperatures to develop competitive efficiencies. The use of coal derived syngas introduces a range of potential contaminants into the hot section of the gas turbine including sulfur, iron, calcium, and various alkali metals. Depending on the effectiveness of the gas clean up processes, there exists significant likelihood that the remaining materials will become molten in the combustion process and potentially deposit on downstream turbine surfaces. Past evidence suggests that deposition will be a strong function of increasing temperature. Currently, even with the best gas cleanup processes a small level of particulate matter in the syngas is expected. Consequently, particulate deposition is expected to be an important consideration in the design of turbine components. The leading edge region of first stage vanes most often have higher deposition rates than other areas due to strong fluid acceleration and streamline curvature in the vicinity of the surface. This region remains one of the most difficult areas in a turbine nozzle to cool due to high inlet temperatures and only a small pressure ratio for cooling. The leading edge of a vane often has relatively high heat transfer coefficients and is often cooled using showerhead film cooling arrays. The throat of the first stage nozzle is another area where deposition potentially has a strongly adverse effect on turbine performance as this region meters the turbine inlet flow. Based on roughness levels found on in service vanes (Bons, et al., 2001, up to 300 microns) flow blockage in first stage turbine nozzles can easily reach 1 to 2 percent in conventional turbines. Deposition levels in syngas fueled gas turbines are expected to be even more problematic. The likelihood of significant deposition to the leading edge of vanes in a syngas environment indicates the need to examine this effect on the leading edge cooling problem. It is critical to understand the influence of leading edge geometry and turbulence on deposition rates for both internally and showerhead cooled leading edge regions. The expected level of deposition in a vane stagnation region not only significantly changes the heat transfer problem but also suggests that cooling arrays may clog. Addressing the cooling issue suggests a need to better understand stagnation region heat transfer with realistic roughness as well as the other variables affecting transport near the leading edge. Also, the question of whether leading edge regions can be cooled internally with modern cooling approaches should also be raised, thus avoiding the clogging issue. Addressing deposition in the pressure side throat region of the nozzle is another critical issue for this environment. Issues such as examining the protective effect of slot and full coverage discrete-hole film cooling on limiting deposition as well as the influence of roughness and turbulence on effectiveness should be raised. The objective of this present study is to address these technical challenges to help enable the development of high efficiency syngas tolerant gas turbine engines.

01 COAL, LIGNITE, AND PEAT↗

A Novel Non-Parametric Density Estimation Approach to Measuring Muon Ionization Cooling and Reverse Emittance Exchange in the MICE Experiment

The Muon Ionization Cooling Experiment (MICE) located at Rutherford Ap- pleton Laboratory in the U.K. has demonstrated muon ionization beam cooling for the rst time. A beam of muons in MICE is produced from high-energy proton beam collision with a xed target, generating pions which in turn decay into muons. Pion-decay muons, thus, are tertiary particles and, as a result, occupy a large vol- ume in position{momentum phase space. To t the muon beam into smaller and more cost-eective accelerating devices, muon beam phase{space volume needs to be reduced (beam cooling). Ionization beam cooling, which before MICE has never been demonstrated experimentally for muons, is the only technique fast enough to be used for muons within their short lifetime. Ionization cooling occurs when muons traverse an absorbing material and lose momentum through ionization energy loss. The cooling eect in MICE is measured using two scintillating-ber tracking detec- tors. These trackers, one upstream and one downstream of the absorber, reconstruct and measure the position and momentum coordinates of each muon. Given the pre- cision MICE needed to demonstrate beam cooling, it is necessary to develop analysis tools that can account for any eects that may lead to inaccurate measurement of cooling, such as non{linear eects in beam optics. Non{parametric density estima- tion techniques, such as kernel density estimation (KDE), provide a basis for creating analysis tools that are robust against these eects, directly calculating the muon beam phase-space density and volume for demonstrating beam cooling. This thesis focuses on the application of KDE to the measurement of beam cooling in MICE. The KDE technique is validated using known distributions and is applied to sim- ulated and experimental MICE data corresponding to the various magnet, optics, and absorber congurations. Using the KDE technique, muon beam cooling in the four{dimensional transverse phase space, as well as reverse emittance exchange using MICE data have been demonstrated.

43 PARTICLE ACCELERATORS↗

Biologically Cooling the Planet: A BRISK Approach that Directly Connects the Ground to Deep Space

Climate change is a grave threat to our ability to thrive and prosper on Earth. Accumulation of greenhouse gases in the atmosphere stifle the Earth’s ability to cool itself, which leads to a rise of the average temperature – Global warming. The planetary cooling is exclusively radiative – thermal radiation escapes into cold outer space via a flux of photons at the low-infrared range. The penetration of these photons through Earth’s atmosphere is dictated by atmospheric transparency, which, serendipitously possesses a window centered around the peak of the Plank spectrum for a black body at about room temperature – the average temperature of Earth. This window spanning about 8 --13 μm wavelengths allows most of the photons in this range to escape into the Cosmos carrying our planet’s heat away. The efficiency of this outer heat flux – and thus planet’s cooling ability – can be controlled via emissivity – a function of wavelength which multiplies the fundamental Plank spectrum of a black body at a given temperature. In the presence of non-trivial atmospheric transparency it can be shown that radiative cooling can be enhanced with properly “designed” emissivity function. For the last 100 years, or so, people have been looking into ways to engineer materials to take advantage of such enhancement for various cooling applications, from making ice to cool clothes, and substantial progress has been achieved, including cooling in direct sunlight. The beauty if this approach is that it is entirely passive – no energy input is required. The objective of this project was to investigate whether biological systems possess such advanced cooling capacity, developed via millennia of evolution, to enhance plant’s adaptation to a hot environment, to increase cooling capability, and possibly modulate spectral emissivities on short or long time scales. We wanted to know if BRISK (Biological Radiative Sky Cooling) occurs and to what extent. It is unknown whether biological systems can perform this "spectral redistribution." It is reasonable to expect, however, that they might: in particular, desert plants under high heat stress and arid conditions might evolve this mechanism in order to maintain a tolerable internal temperature. Our intended approach was twofold: extensive literature search and supporting experimental investigations on select plants. We obtained the answers from the former, while the latter proved to be more complicated to perform with required accuracy in the timespan/budget of a small seedling project. After one year of research, we concluded that among the plant species studied there seem to be no evidence of BRISK, but it’s not the end of the story. Our planet’s biosphere is immense, and the evolution is continuing. With our preliminary results and a better understanding of what to look for further discoveries await, considering the accelerated pace of infrared imaging and spectroscopy technology development, from microscopic to satellite-based studies of plants and canopies. In the end, Earth’s energy balance is ultimately tied to radiative cooling so that further investigation into this problem is directly tied to solving the Climate Change challenge.

54 ENVIRONMENTAL SCIENCES↗

Water Recovery From Cooling Tower Plumes

According to studies by the UN and the US State Department, we are on the path to an extreme freshwater shortage by 2030. The US’s largest water withdrawal source is power plants, which account for 39% of total US freshwater withdrawals, mostly for cooling. Cooling towers are the most common cooling system. To solve these problems and enable efficient water- based cooling – Infinite Cooling’s novel technology uses electric fields to ionize the air, charge the escaping water leaving cooling towers and direct the water toward mesh collectors where it collects and gets recycled for use in the cooling system. This technology was developed at MIT and was reduced to practice on a lab-scale prototype, and a prototype at the MIT Cogeneration Power Plant. This DOE award funded taking this technology from a lab-scale prototype to TRL 5 on an operating cooling tower in the field at the MIT Nuclear Research Laboratory. The funding helped to design and optimize an electrostatic plume collection system and test it in high-fidelity lab setting and in actual field conditions on a cooling tower. Throughout the award, Infinite Cooling investigated the formation of plumes on cooling towers, used that information to optimize the design, material and electrical properties of the collection device and quantified the collection yield via flow rate and water quality.

20 FOSSIL-FUELED POWER PLANTS↗

Evidence for AGN-regulated Cooling in Clusters at z ∼ 1.4: A Multiwavelength View of SPT-CL J0607-4448

Abstract We present a multiwavelength analysis of the galaxy cluster SPT-CL J0607-4448 (SPT0607), which is one of the most distant clusters discovered by the South Pole Telescope at z = 1.4010 ± 0.0028. The high-redshift cluster shows clear signs of being relaxed with well-regulated feedback from the active galactic nucleus (AGN) in the brightest cluster galaxy (BCG). Using Chandra X-ray data, we construct thermodynamic profiles and determine the properties of the intracluster medium. The cool-core nature of the cluster is supported by a centrally peaked density profile and low central entropy ( K 0 = 18 − 9 + 11 keV cm 2 ), which we estimate assuming an isothermal temperature profile due to the limited spectral information given the distance to the cluster. Using the density profile and gas cooling time inferred from the X-ray data, we find a mass-cooling rate M ̇ cool = 100 − 60 + 90 M ⊙ yr −1 . From optical spectroscopy and photometry around the [O ii ] emission line, we estimate that the BCG star formation rate is SFR [ O II ] = 1.7 − 0.6 + 1.0 M ⊙ yr −1 , roughly two orders of magnitude lower than the predicted mass-cooling rate. In addition, using ATCA radio data at 2.1 GHz, we measure a radio jet power P cav = 3.2 − 1.3 + 2.1 × 10 44 erg s −1 , which is consistent with the X-ray cooling luminosity ( L cool = 1.9 − 0.5 + 0.2 × 10 44 erg s −1 within r cool = 43 kpc). These findings suggest that SPT0607 is a relaxed, cool-core cluster with AGN-regulated cooling at an epoch shortly after cluster formation, implying that the balance between cooling and feedback can be reached quickly. We discuss the implications for these findings on the evolution of AGN feedback in galaxy clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis and comparison of wall cooling schemes for advanced gas turbine applications

The relative performance of (1) counterflow film cooling, (2) parallel-flow film cooling, (3) convection cooling, (4) adiabatic film cooling, (5) transpiration cooling, and (6) full-coverage film cooling was investigated for heat loading conditions expected in future gas turbine engines. Assumed in the analysis were hot-gas conditions of 2200 K (3500 F) recovery temperature, 5 to 40 atmospheres total pressure, and 0.6 gas Mach number and a cooling air supply temperature of 811 K (1000 F). The first three cooling methods involve film cooling from slots. Counterflow and parallel flow describe the direction of convection cooling air along the inside surface of the wall relative to the main gas flow direction. The importance of utilizing the heat sink available in the coolant for convection cooling prior to film injection is illustrated.

Colladay, R. S.↗

Optical emission from cooling flows in distant x ray clusters of galaxies

Although the Einstein satellite detected cooling flows in the x ray emission from clusters of galaxies 10 years ago, the understanding of these flows remains incomplete. The x ray emitting gas in the centers of these clusters is so dense that its cooling time is shorter than a Hubble time. Thus gas may cool and flow into the center of the cluster. This cooling gas is thermally unstable and should quickly become inhomogeneous. Optical filamentation (1-100 kpc scales) often appears near the centers of nearby clusters containing cooling flows, usually within the central galaxies accreting the gas. Indeed, only clusters with well-developed cooling flows seem to possess highly luminous, emission-line nebulae. Researchers present here some results of preliminary observational and theoretical studies of this class of emission-line objects. Researchers observed a complete, x ray selected sample of 25 distant clusters of galaxies extracted from the Einstein Extended Medium Sensitivity Survey. They discovered luminous extended H alpha emission in 10 of these clusters. Thus at least 40 percent of the clusters in the sample contain cool gas. If we crudely compare the sample to that of Arnaud (1988), in which approx. 40 percent of his 104 x ray clusters have cooling flows, the result implies that cooling flows may actually be a more common phenomenon in the past than in the present. The connection between the cooling flow and the H alpha emission is a mystery. The straightforward calculation of 1 (photoionization) to 3 (shocks) recombinations per H atom in the cooling flow gives mass infall rates 3 to 100 times greater than M derived from x ray observations. Researchers have made some preliminary theoretical calculations in an attempt to resolve this problem.

Donahue, Megan↗

Experimental Study of Vane Heat Transfer and Film Cooling at Elevated Levels of Turbulence

This report documents the results of an experimental study on the influence of high level turbulence on vane film cooling and the influence of film cooling on vane heat transfer. Three different cooling configurations were investigated which included one row of film cooling on both pressure and suction surfaces, two staggered rows of film cooling on both suction and pressure surfaces, and a shower-head cooling array. The turbulence had a strong influence on film cooling effectiveness, particularly on the pressure surface where local turbulence levels were the highest. For the single row of holes, the spanwise mixing quickly reduced centerline effectiveness levels while mixing in the normal direction was more gradual. The film cooling had a strong influence on the heat transfer in the laminar regions of the vane. The effect of film cooling on heat transfer was noticeable in the turbulent regions but augmentation ratios were significantly lower. In addition to heat transfer and film cooling, velocity profiles were taken downstream of the film cooling rows at three spanwise locations. These profile comparisons documented the strong spanwise mixing due to the high turbulence. Total pressure exit measurements were also documented for the three configurations.

Ames, Forrest E.↗