Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

The effects of Doppler broadening and detector resolution on the performance of three-stage Compton cameras

Purpose: The authors investigated how the characteristics of the detectors used in a three-stage Compton camera (CC) affect the CC's ability to accurately measure the emission distribution and energy spectrum of prompt gammas (PG) emitted by nuclear de-excitations during proton therapy. The detector characteristics they studied included the material (high-purity germanium [HPGe] and cadmium zinc telluride [CZT]), Doppler broadening (DB), and resolution (lateral, depth, and energy). Methods: The authors simulated three-stage HPGe and CZT CCs of various configurations, detecting gammas from point sources with energies ranging from 0.511 to 7.12 MeV. They also simulated a proton pencil beam irradiating a tissue target to study how the detector characteristics affect the PG data measured by CCs in a clinical proton therapy setting. They used three figures of merit: the distance of closest approach (DCA) and the point of closest approach (PCA) between the measured and actual position of the PG emission origin, and the calculated energy resolution. Results: For CCs with HPGe detectors, DB caused the DCA to be greater than 3 mm for 14% of the 6.13 MeV gammas and 20% of the 0.511 MeV gammas. For CCs with CZT detectors, DB caused the DCA to be greater than 3 mm for 18% of the 6.13 MeV gammas and 25% of the 0.511 MeV gammas. The full width at half maximum (FWHM) of the PCA in the z-caret direction for HPGe and CZT detectors ranged from 1.3 to 0.4 mm for gammas with incident energy ranging from 0.511 to 7.12 MeV. For CCs composed of HPGe detectors, the resolution of incident gamma energy calculated by the CC ranged from 6% to 1% for gammas with true incident energies from 0.511 to 7.12 MeV. For CCs composed of CZT detectors, the resolution of gamma energy calculated by the CC ranged from 10% to 1% for gammas with true incident energies from 0.511 to 7.12 MeV. For HPGe and CZT CCs in which all detector effect were included, the DCA was less than 3 mm for 75% and 68% of the detected gammas, respectively, and restricting gammas to those having energy greater than 2.0 MeV increased these percentages to 83% and 77% for HPGe and CZT, respectively. Distributions of the true gamma origins and the PCA after detector characteristics had been included showed good agreement on beam range and some loss of resolution for the lateral profile of the PG emission. Characteristic energy lines were evident in the calculated gamma energy spectrum. Conclusions: The authors found the following: (1) DB is the dominant source of spatial and energy resolution loss in the CCs at all energy levels; (2) the largest difference in the spatial resolution of HPGe and CZT CCs is that the spatial resolution distributions of CZT have broader tails. The differences in the FWHM of these distributions are small; (3) the energy resolution of both HPGe and CZT three-stage CCs is adequate for PG spectroscopy; and (4) restricting the gammas to those having energy greater than 2.0 MeV can improve the achievable image resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental confirmation of neoclassical Compton scattering theory

Incoherent X-ray scattering spectra of diamond and silicon crystals recorded on the BESSY-2 electron storage ring have been analyzed. All spectral features are described well in terms of the neoclassical scattering theory without consideration for the hypotheses accepted in quantum electrodynamics. It is noted that the accepted tabular data on the intensity ratio between the Compton and Rayleigh spectral components may significantly differ from the experimental values. It is concluded that the development of the general theory (considering coherent scattering, incoherent scattering, and Bragg diffraction) must be continued.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intershell correlations in nonresonant Compton scattering of an X-ray photon by an atom

The role of intershell correlations in nonresonant Compton scattering of an X-ray photon by a free multielectron atom is studied theoretically for the Ar atom. The results of calculation are of a predictive nature. The developed mathematical formalism is general in nature and can be applied to a wide set of elements from the Periodic Table, for which the description of the wavefunctions of scattering states in the nonrelativistic Hartree-Fock approximation remains correct.

74 ATOMIC AND MOLECULAR PHYSICS↗

Compton scattering of an X-ray photon by an open-shell atom

A nonrelativistic quantum theory for the nonresonant Compton scattering of an X-ray photon by a free many-electron atom with an open shell in the ground state has been constructed in the single-configuration Hartree-Fock approximation outside the impulse approximation widely used in the literature. The transition to an atom with closed shells reproduces the results obtained previously in [6, 7]. The results of a test calculation for atoms with open (Ti, Fe) and closed (Zn) 3d core shells are presented. The effects of the radial relaxation of one-electron states in the field of core vacancies have been taken into account. The results of the calculation agree well with the experimental results [15, 16]. It has been established that the results of the impulse approximation in the investigated X-ray photon energy ranges disagree with those of our theory not only quantitatively but also qualitatively. In particular, the impulse approximation near the elastic (Thomson and Rayleigh) scattering line leads to a gross overestimation of the contributions from the deep atomic shells involved in the inelastic photon scattering only virtually to the scattering probability. The presented theory is general in character and its applicability to a particular element of the Mendeleev table with an open core shell or to a many-electron atomic ion is limited only by the requirement that the nonrelativistic Hartree-Fock approximation be properly used in describing the scattering-state wave functions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantum theory of stimulated Cherenkov emission and stimulated compton scattering of electromagnetic waves by a low-density relativistic electron beam

A quantum theory of instabilities of a relativistic electron beam due to the stimulated Cherenkov effect in a dielectric and the stimulated Compton effect in vacuum is presented. The instability growth rates are found in a linear approximation and are shown to go over to the familiar growth rates in the classical approximation. A nonlinear theory of instabilities in the quantum case is developed. Analytic solutions are obtained that describe the nonlinear saturation of the amplitudes of the electromagnetic waves emitted by the beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using Multichannel Laser Complexes for Incoherent Pumping of X-ray Compton Free-Electron Lasers

It is used that there is great potential in the use of multichannel laser complexes for incoherent pumping of X-ray Compton free-electron lasers based on stimulated wave backscattering on high-current moderately relativistic electron beam. The relative width of the pump spectrum must be comparable with that of the energy spectrum of the electron beam, which ensures involvement of a significant fraction of particles into the scattering process and, hence, high efficiency of their kinetic energy conversion into X-ray radiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Beam charge asymmetries for deeply virtual Compton scattering off the proton

The unpolarized and polarized Beam Char\-ge Asymmetries (BCAs) of the $\overrightarrow{e}^{\pm}p \to e^{\pm}p \gamma$ process off unpolarized hydrogen are discussed. The measurement of BCAs with the CLAS12 spectrometer at the Thomas Jefferson National Accelerator Facility, using polarized positron and electron beams at 10.6 GeV is investigated. This experimental configuration allows to measure azimuthal and $t$-dependences of the unpolarized and polarized BCAs over a large $(x_B,Q^2)$ phase space, providing a direct access to the real part of the Compton Form Factor (CFF) ${\mathcal H}$. Additionally, these measurements confront the Bethe-Heitler dominance hypothesis and eventual effects beyond leading twist. The impact of potential positron beam data on the determination of CFFs is also investigated within a local fitting approach of experimental observables. Finally, positron data are shown to strongly reduce correlations between CFFs and consequently improve significantly the determination of $\Re {\rm e} [\mathcal{H}]$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A laser inverse Compton scattering diagnostic to study runaway electron dynamics during tokamak disruptions

The goal is to design a new diagnostic based on laser inverse Compton scattering (LICS) to study the dynamics of runaway electron formation and their subsequent loss during triggered disruptions in DIII-D. It is known that better measurements of the runaway electron population, throughout the evolution of a disruption, is critical for mitigating the impact of energetic electron beams especially in high plasma current discharges such as those in reactor relevant burning plasmas. The goal of the LICS approach being designed for DIII-D is to measure the timeresolved spatial profile and energy distribution of the runaway electrons while they are in the core of the tokamak plasma. During the last year, a code was developed to simulate the signals from a new laser scattering diagnostic for DIII-D, which will measure the relativistic electron population expected in DIII-D after disruptions triggered by argon pellet injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The equivalence of inverse Compton scattering and the undulator concept

Inverse Compton scattering is a method to produce very high frequency photon beam. However, the production mechanism can also be viewed as a undulator emission. This is because the electron sees electric and magnetic fields of the incident laser beam and is driven into transverse oscillatory motion in exactly the same way when the electron passes through a undulator consisting of alternating magnetic field. This note gives a detailed examination of the similarity about the two views. Equivalent undulator parameters are derived for the incident laser beam, as well as the differential cross section of photon emission.

43 PARTICLE ACCELERATORS↗

Deeply virtual Compton scattering at Jefferson Lab

The Generalized Parton Distribution framework was introduced in the late 90’s and describes the nucleon in a revolutionary way, correlating the information from both momentum and transverse position space into experimentally accessible functions. After a brief introduction, this article reviews the Jefferson Lab 6 GeV measurements of Deeply Virtual Compton Scattering in Halls A and B, which give a unique access to Generalized Parton Distributions (GPD). The second part of this article reviews the Jefferson Lab 12 GeV upgrade in general terms, and then focuses on the GPD program in Halls A and B.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

INVERSE COMPTON X-RAY EMISSION FROM TeV BLAZAR MRK 421 DURING A HISTORICAL LOW-FLUX STATE OBSERVED WITH NuSTAR

We report on the detection of excess hard X-ray emission from the TeV BL Lac object Mrk 421 during the historical low-flux state of the source in 2013 January. Nuclear Spectroscopic Telescope Array observations were conducted four times between MJD 56294 and MJD 56312 with a total exposure of 80.9 ks. The source flux in the 3–40 keV range was nearly constant, except for MJD 56307 when the average flux level increased by a factor of three. Throughout the exposure, the X-ray spectra of Mrk 421 were well represented by a steep power-law model with a photon index of Γ ≃ 3.1, although a significant excess was noted above 20 keV in the MJD 56302 data when the source was in its faintest state. Moreover, Mrk 421 was detected at more than the 4 σ level in the 40–79 keV count maps for both MJD 56307 and MJD 56302 but not during the remaining two observations. The detected excess hard X-ray emission connects smoothly with the extrapolation of the high-energy γ -ray continuum of the blazar constrained by Fermi -LAT during source quiescence. These findings indicate that while the overall X-ray spectrum of Mrk 421 is dominated by the highest-energy tail of the synchrotron continuum, the variable excess hard X-ray emission above 20 keV (on the timescale of a week) is related to the inverse Compton emission component. We discuss the resulting constraints on the variability and spectral properties of the low-energy segment of the electron energy distribution in the source.

79 ASTRONOMY AND ASTROPHYSICS↗

The internal Compton effect

Internal Compton effect, and use of superconducting magnet spectrometer to determine multipolarity assignments

MAGNET↗

Observations of MCG-5-23-16 with Suzaku, XMM-Newton and NuSTAR: Disk Tomography and Compton Hump Reverberation

MCG-5-23-16 is one of the first active galactic nuclei (AGNs) where relativistic reverberation in the iron K line originating in the vicinity of the supermassive black hole was found, based on a short XMM-Newton observation. In this work, we present the results from long X-ray observations using Suzaku, XMM-Newton, and NuSTAR designed to map the emission region using X-ray reverberation. A relativistic iron line is detected in the lag spectra on three different timescales, allowing the emission from different regions around the black hole to be separated. Using NuSTAR coverage of energies above 10 keV reveals a lag between these energies and the primary continuum, which is detected for the first time in an AGN. This lag is a result of the Compton reflection hump responding to changes in the primary source in a manner similar to the response of the relativistic iron K line.

NUSTAR↗