Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Color”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Uncertainties in the Geostationary Ocean Color Imager (GOCI) Remote Sensing Reflectance for Assessing Diurnal Variability of Biogeochemical Processes

Short-term (sub-diurnal) biological and biogeochemical processes cannot be fully captured by the current suite of polar-orbiting satellite ocean color sensors, as their temporal resolution is limited to potentially one clear image per day. Geostationary sensors, such as the Geostationary Ocean Color Imager (GOCI) from the Republic of Korea, allow the study of these short-term processes because their orbit permit the collection of multiple images throughout each day for any area within the sensor’s field of regard. Assessing the capability to detect sub-diurnal changes in in-water properties caused by physical and biogeochemical processes characteristic of open ocean and coastal ocean ecosystems, however, requires an understanding of the uncertainties introduced by the instrument and/or geophysical retrieval algorithms. This work presents a study of the uncertainties during the daytime period for an ocean region with characteristically low-productivity with the assumption that only small and undetectable changes occur in the in-water properties due to biogeochemical processes during the daytime period. The complete GOCI mission data were processed using NASA’s SeaDAS/l2gen package. The assumption of homogeneity of the study region was tested using three-day sequences and diurnal statistics. This assumption was found to hold based on the minimal diurnal and day-to-day variability in GOCI data products. Relative differences with respect to the midday value were calculated for each hourly observation of the day in order to investigate what time of the day the variability is greater. Also, the influence of the solar zenith angle in the retrieval of remote sensing reflectances and derived products was examined. Finally, we determined that the uncertainties in water-leaving “remote-sensing” reflectance (Rrs) for the 412, 443, 490, 555, 660 and 680 nm bands on GOCI are 8.05 × 10−4, 5.49 × 10−4, 4.48 × 10−4, 2.51 × 10−4, 8.83 × 10−5, and 1.36 × 10−4 sr−1, respectively, and 1.09 × 10−2 mg m−3 for the chlorophyll-a concentration (Chl-a), 2.09 × 10−3 m−1 for the absorption coefficient of chromophoric dissolved organic matter at 412 nm (ag (412)), and 3.7 mg m−3 for particulate organic carbon (POC). These Rrs values can be considered the threshold values for detectable changes of the in-water properties due to biological, physical or biogeochemical processes from GOCI.

Geostationary Ocean Color Imager (GOCI)↗

Efficient, Color-Stable, and Long-Lived White Organic Light-Emitting Diodes Utilizing Phosphorescent Molecular Aggregates

Highly efficient and stable single-stack hybrid white organic light-emitting diode (WOLED) devices are developed using two emissive layers: one with amber-colored phosphorescent molecular-aggregate emission from the Pd(II) complex, Pd(II) 7-(3-(pyridine-2-yl-κN)phenoxy-κC)(benzo-κC)([c]benzo[4,5]imidazo-κN)[1,2-a][1,5]naphthyridine, Pd3O8-Py5, and the other with blue fluorescence emission. Here, an optimized device structure achieves high color stability under various current densities, an external quantum efficiency (EQE) of 45.5%, a power efficiency of 97.4 Lm W -1 , and an estimated LT 95 (operational time to 95% of the initial luminance) of 50 744 h at an initial luminance of 1000 cd m -2 .

36 MATERIALS SCIENCE↗

Color as a tool for quantitative analysis of heterogeneous polymer degradation

Polymers are widely used industry, but degrade due to environmental conditions, such as elevated temperature or radiation. The degradation of polymers is dominated oxidation in oxygenated environments. Such oxidation is commonly referred to as thermal-oxidation or photo-oxidation and in many situations is heterogeneous through thickness of the polymer. While heterogeneous oxidation of polymers is a common phenomenon, the effect on the lifetime of polymers is not well understood as methods to evaluate such oxidation are time consuming and challenging to implement. Here we show a novel method for quantitative evaluation of heterogeneous oxidation in polymers using a fast and accurate color approach. The proposed color approach was observed to improve the efficiency of obtaining heterogenous oxidation profiles in half the time of common approaches, such as indention or Fourier transform infrared spectroscopy. Furthermore, the method was found to produce trends similar to that observed using common approaches and the applicability of the method was verified by mapping oxygen concentration through thickness using energy dispersive X-ray spectroscopy. Lastly, the utility of the proposed method was demonstrated through the generation of an oxidation design space, which is envisioned to assist with designing experiments towards estimation of polymer lifetime. Finally, we anticipate this work to be a starting point for further evaluation of heterogeneous oxidation in polymers using optical properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combining femtosecond laser annealing and shallow ion implantation for local color center creation in diamond

A common technique for color center creation in wideband gap semiconductors employs ion implantation and a subsequent thermal annealing. In general, this annealing process is conducted in a vacuum oven. Here, we exploit the annealing based on femtosecond laser pulses. For that purpose, we implant fluorine ions at 54 keV and chlorine ions at 74 keV in diamond and perform micrometer precise annealing using focused femtosecond laser pulses at 800 ± (30) nm with different pulse numbers and repetition rates. In this way, we were able to create shallow spots with color centers of varying brightness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Passive Low-Energy Nuclear-Recoil Detection with Color Centers

Crystal-damage events such as tracks and point defects have been used to record and detect radiation for a long time and recently they have been proposed as a means for dark-matter detection. Color centers can be read out optically and we propose a scheme based on selective plane illumination microscopy for micrometer-scale imaging of large volumes corresponding to kilogram mass detectors. This class of detectors would be passive and would operate at room temperature and we call this the passive low-energy optical color-center nuclear-recoil (PALEOCCENE) detection method. We apply these concepts to the detection of reactor neutrinos using coherent elastic neutrino nucleus scattering (CE ν NS). Crystal-damage formation energies are intrinsically on the order of 25 eV, resulting in similarly low nuclear-recoil thresholds. Furthermore, this would enable the observation of reactor-neutrino CE ν NS with detectors as small as 10 g. Additionally, a competitive search for spin-dependent dark-matter scattering down to a dark-matter mass of 0.3 GeV could be possible. Passive crystal detectors might also be attractive for nuclear-nonproliferation safeguards if used to monitor reactor power and to put limits on plutonium production. The passive nature and small footprint of the proposed detectors implies that these might fit well within accepted reactor-safeguards operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ruling out Color Transparency in Quasielastic 12 C(e,e'p) up to Q 2 of 14.2 (GeV/c) 2

Quasielastic $^{12}$C$(e,e'p)$ scattering was measured at space-like 4-momentum transfer squared $Q^2$ = 8, 9.4, 11.4, and 14.2 (GeV/c)$^2$, the highest ever achieved to date. Nuclear transparency for this reaction was extracted by comparing the measured yield to that expected from a plane-wave impulse approximation calculation without any final state interactions. Additionally, the measured transparency was consistent with no $Q^2$ dependence, up to proton momenta of 8.5 GeV/c, ruling out the quantum chromodynamics effect of color transparency at the measured $Q^2$ scales in exclusive $(e,e'p)$ reactions. Furthermore, these results impose strict constraints on models of color transparency for protons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Many-Electron System on Helium and Color Center Spectroscopy

Electrons on the helium surface display sharp resonant absorption lines related to the transitions between the subbands of quantized motion transverse to the surface. A magnetic field parallel to the surface strongly affects the absorption spectrum.We show that the effect results from admixing the intersubband transitions to the in-plane quantum dynamics of the strongly correlated electron liquid or a Wigner crystal. This is similar to the admixing of electron transitions in color centers to phonons. Furthermore, the spectrum permits a direct characterization of the many-electron dynamics and also enables testing the theory of color centers in a system with controllable coupling.

36 MATERIALS SCIENCE↗

Exploration of Defect Dynamics and Color Center Qubit Synthesis with Pulsed Ion Beams

Short-pulse ion beams have been developed in recent years and now enable applications in materials science. A tunable flux of selected ions delivered in pulses of a few nanoseconds can affect the balance of defect formation and dynamic annealing in materials. We report results from color center formation in silicon with pulses of 900 keV protons. G-centers in silicon are near-infrared photon emitters with emerging applications as single-photon sources and for spin-photon qubit integration. G-centers consist of a pair of substitutional carbon atoms and one silicon interstitial atom and are often formed by carbon ion implantation and thermal annealing. Here, we report on G-center formation with proton pulses in silicon samples that already contained carbon, without carbon ion implantation or thermal annealing. The number of G-centers formed per proton increased when we increased the pulse intensity from 6.9 × 10 9 to 7.9 × 10 10 protons/cm 2 /pulse, demonstrating a flux effect on G-center formation efficiency. We observe a G-center ensemble linewidth of 0.1 nm (full width half maximum), narrower than previously reported. Pulsed ion beams can extend the parameter range available for fundamental studies of radiation-induced defects and the formation of color centers for spin-photon qubit applications.

43 PARTICLE ACCELERATORS↗

Optical Classification of Lower Amazon Waters Based on In Situ Data and Sentinel-3 Ocean and Land Color Instrument Imagery

Optical water types (OWTs) were identified from an in situ dataset of concomitant biogeochemical and optical parameters acquired in the Amazon River and its tributaries, in the Lower Amazon region, at different hydrological conditions from 2014 to 2017. A seasonal bio-optical characterization was performed. The k-means classification was applied to the in situ normalized reflectance spectra (rn(λ)), allowing the identification of four OWTs. An optical index method was also applied to the rn(λ) defining the thresholds of the OWTs. Next, level-3 Sentinel-3 Ocean and Land Color Instrument images representative of the seasonal discharge conditions were classified using the identified in situ OWTs as reference. The differences between Amazon River and clearwater tributary OWTs were dependent on the hydrological dynamics of the Amazon River, also showing a strong seasonal variability. Each OWT was associated with a specific bio-optical and biogeochemical environment assessed from the corresponding absorption coefficient values of colored dissolved organic matter (aCDOM) and particulate matter (ap), chlorophyll-a and suspended particulate matter (SPM) concentrations, and aCDOM/ap ratio. The rising water season presented a unique OWT with high SPM concentration and high relative contribution of ap to total absorption compared to the other OWTs. This bio-optical characterization of Lower Amazon River waters represents a first step for developing remote sensing inversion models adjusted to the optical complexity of this region.

54 ENVIRONMENTAL SCIENCES↗

Colors of Irregular Satellites of Saturn with the Dark Energy Camera

We report g – r and r – i new colors for 21 Saturn Irregular Satellites; among them, four previously unreported. This is the highest number of Saturn Irregular satellites reported in a single survey. These satellites were measured by "stacking" their observations to increase their signal without trailing. This work describes a novel processing algorithm that enables the detection of faint sources under significant background noise and in front of a severely crowded field. Our survey shows these new color measurements of Saturn Irregular Satellites are consistent with other Irregular Satellites populations as found in previous works and reinforcing the observation that the lack of ultrared objects among the irregular satellites is a real feature that separates them from the trans-Neptunian objects (their posited source population).

79 ASTRONOMY AND ASTROPHYSICS↗

Digital storage and analysis of color Doppler echocardiograms

Color Doppler flow mapping has played an important role in clinical echocardiography. Most of the clinical work, however, has been primarily qualitative. Although qualitative information is very valuable, there is considerable quantitative information stored within the velocity map that has not been extensively exploited so far. Recently, many researchers have shown interest in using the encoded velocities to address the clinical problems such as quantification of valvular regurgitation, calculation of cardiac output, and characterization of ventricular filling. In this article, we review some basic physics and engineering aspects of color Doppler echocardiography, as well as drawbacks of trying to retrieve velocities from video tape data. Digital storage, which plays a critical role in performing quantitative analysis, is discussed in some detail with special attention to velocity encoding in DICOM 3.0 (medical image storage standard) and the use of digital compression. Lossy compression can considerably reduce file size with minimal loss of information (mostly redundant); this is critical for digital storage because of the enormous amount of data generated (a 10 minute study could require 18 Gigabytes of storage capacity). Lossy JPEG compression and its impact on quantitative analysis has been studied, showing that images compressed at 27:1 using the JPEG algorithm compares favorably with directly digitized video images, the current goldstandard. Some potential applications of these velocities in analyzing the proximal convergence zones, mitral inflow, and some areas of future development are also discussed in the article.

NASA Discipline Cardiopulmonary↗

Ocean Color Measurements with the Operational Land Imager on Landsat-8: Implementation and Evaluation in SeaDAS

The Operational Land Imager (OLI) is a multispectral radiometer hosted on the recently launched Landsat8 satellite. OLI includes a suite of relatively narrow spectral bands at 30 m spatial resolution in the visible to shortwave infrared, which makes it a potential tool for ocean color radiometry: measurement of the reflected spectral radiance upwelling from beneath the ocean surface that carries information on the biogeochemical constituents of the upper ocean euphotic zone. To evaluate the potential of OLI to measure ocean color, processing support was implemented in Sea-viewing Wide Field-of-View Sensor (SeaWiFS) Data Analysis System (SeaDAS), which is an open-source software package distributed by NASA for processing, analysis, and display of ocean remote sensing measurements from a variety of spaceborne multispectral radiometers. Here we describe the implementation of OLI processing capabilities within SeaDAS, including support for various methods of atmospheric correction to remove the effects of atmospheric scattering and absorption and retrieve the spectral remote sensing reflectance (Rrs; sr−1). The quality of the retrieved Rrs imagery will be assessed, as will the derived water column constituents, such as the concentration of the phytoplankton pigment chlorophyll a.

Measurements↗

A Semianalytical Ocean Color Inversion Algorithm with Explicit Water Column Depth and Substrate Reflectance Parameterization

A semianalytical ocean color inversion algorithm was developed for improving retrievals of inherent optical properties (IOPs) in optically shallow waters. In clear, geometrically shallow waters, light reflected off the seafloor can contribute to the water-leaving radiance signal. This can have a confounding effect on ocean color algorithms developed for optically deep waters, leading to an overestimation of IOPs. The algorithm described here, the Shallow Water Inversion Model (SWIM), uses pre-existing knowledge of bathymetry and benthic substrate brightness to account for optically shallow effects. SWIM was incorporated into the NASA Ocean Biology Processing Group's L2GEN code and tested in waters of the Great Barrier Reef, Australia, using the Moderate Resolution Imaging Spectroradiometer (MODIS) Aqua time series (2002-2013). SWIM-derived values of the total non-water absorption coefficient at 443 nm, at(443), the particulate backscattering coefficient at 443 nm, bbp(443), and the diffuse attenuation coefficient at 488 nm, Kd(488), were compared with values derived using the Generalized Inherent Optical Properties algorithm (GIOP) and the Quasi-Analytical Algorithm (QAA). The results indicated that in clear, optically shallow waters SWIM-derived values of at(443), bbp(443), and Kd(443) were realistically lower than values derived using GIOP and QAA, in agreement with radiative transfer modeling. This signified that the benthic reflectance correction was performing as expected. However, in more optically complex waters, SWIM had difficulty converging to a solution, a likely consequence of internal IOP parameterizations. Whilst a comprehensive study of the SWIM algorithm's behavior was conducted, further work is needed to validate the algorithm using in situ data.

Great Barrier Reef↗

Ocean Color Measurements from Landsat-8 OLI using SeaDAS

The Operational Land Imager (OLI) is a multi-spectral radiometer hosted on the recently launched Landsat-8 satellite. OLI includes a suite of relatively narrow spectral bands at 30-meter spatial resolution in the visible to shortwave infrared that make it a potential tool for ocean color radiometry: measurement of the reflected spectral radiance upwelling from beneath the ocean surface that carries information on the biogeochemical constituents of the upper ocean euphotic zone. To evaluate the potential of OLI to measure ocean color, processing support was implemented in SeaDAS, which is an open-source software package distributed by NASA for processing, analysis, and display of ocean remote sensing measurements from a variety of satellite-based multi-spectral radiometers. Here we describe the implementation of OLI processing capabilities within SeaDAS, including support for various methods of atmospheric correction to remove the effects of atmospheric scattering and absorption and retrieve the spectral remote-sensing reflectance (Rrs; sr exp 1). The quality of the retrieved Rrs imagery will be assessed, as will the derived water column constituents such as the concentration of the phytoplankton pigment chlorophyll a.

ocean color↗

Atmospheric Correction for Satellite Ocean Color Radiometry

This tutorial is an introduction to atmospheric correction in general and also documentation of the atmospheric correction algorithms currently implemented by the NASA Ocean Biology Processing Group (OBPG) for processing ocean color data from satellite-borne sensors such as MODIS and VIIRS. The intended audience is graduate students or others who are encountering this topic for the first time. The tutorial is in two parts. Part I discusses the generic atmospheric correction problem. The magnitude and nature of the problem are first illustrated with numerical results generated by a coupled ocean-atmosphere radiative transfer model. That code allow the various contributions (Rayleigh and aerosol path radiance, surface reflectance, water-leaving radiance, etc.) to the topof- the-atmosphere (TOA) radiance to be separated out. Particular attention is then paid to the definition, calculation, and interpretation of the so-called "exact normalized water-leaving radiance" and its equivalent reflectance. Part I ends with chapters on the calculation of direct and diffuse atmospheric transmittances, and on how vicarious calibration is performed. Part II then describes one by one the particular algorithms currently used by the OBPG to effect the various steps of the atmospheric correction process, viz. the corrections for absorption and scattering by gases and aerosols, Sun and sky reflectance by the sea surface and whitecaps, and finally corrections for sensor out-of-band response and polarization effects. One goal of the tutorial-guided by teaching needs- is to distill the results of dozens of papers published over several decades of research in atmospheric correction for ocean color remote sensing.

MODIS↗

Chlorophyll Algorithms for Ocean Color Sensors - OC4, OC5 and OC6

A high degree of consistency and comparability among chlorophyll algorithms is necessary to meet the goals of merging data from concurrent overlapping ocean color missions for increased coverage of the global ocean and to extend existing time series to encompass data from recently launched missions and those planned for the near future, such as PACE, OLCI, HawkEye, EnMAP and SABIA-MAR. To accomplish these goals, we developed 65 empirical ocean color (OC) chlorophyll algorithms for 25 satellite instruments using the largest available and most globally representative database of coincident in situ chlorophyll a and remote sensing reflectances. Excellent internal consistency was achieved across these OC ‘Version -7’ algorithms, as demonstrated by a median regression slope and coefficient of determination (R (sup 2)) of 0.985 and 0.859, respectively, among 903 pairwise comparisons of OC-modeled chlorophyll. SeaWiFS and MODIS-Aqua satellite-to-in situ match-up results indicated equivalent, and sometimes superior, performance to current heritage chlorophyll algorithms.

ocean color↗

Comparing Level-2 and Level-3 Satellite Ocean Color Retrieval Validation Methodologies

Many ocean color data applications leverage global spatially composited Level-3(L3) satellite data, because of their regular Earth-grid frame of reference. However, ocean color satellite retrieval performance is routinely evaluated on Level-2 (L2) data at the native satellite swath resolution and geometries. This study assesses how accurately binned and gridded L3 data represent L2 satellite data products via satellite-to-in situ match-up activities.L2 and L3 satellite data retrievals of the photosynthetic pigment chlorophyll-a are compared with a common in situ data set, revealing similar L2 and L3 satellite-to-in situ performance for both MODIS-Aqua and VIIRS-SNPP. This agreement implies that L2 validation results are generally applicable to L3 data. However, uncertainties are introduced during the generation of L3 data from L2 data. L3 data comparisons introduce a wider temporal window between the time of in situ measurement and the time of the satellite observation, which can unintentionally reflect on the quality of the satellite retrieval or algorithm performance. The choice of L3 map projection may introduce additional uncertainty by spatially distorting the true location of the satellite retrievals. Each manipulation of satellite data beyond theinstrument's native spatio temporal reference (L2) reduces the applicability of L2 validation results to higher data processing levels.

Ocean Color↗