Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Clean Cities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

The future of waste management and reduction shows promise with technological advances that have sparked newer and more efficient methods

The safe, clean, and efficient reduction and management of both radioactive and nonradioactive wastes are essential processes, however, these processes can be time consuming, complicated, and costly. The goal of this poster is to research possible waste solutions that will encourage the use of more environmentally and monetarily efficient methods of waste disposal, and decrease the amount of hazardous waste bound for energy recovery, treatment, and disposal facilities. Technological advances such as smart trash bins provide a more efficient means of disposing solid wastes and encouraging recycling. Using artificial intelligence, these bins are able to categorize and separate different forms of waste and recyclable material. The smart bins also provide a method for ensuring the most efficient pick up times for waste facilities. This is done with the use of trash bin sensors, thus, overtime saving money and reducing CO2 emissions. Some countries are also finding ways on a larger scale to reduce waste and encourage environmentally friendly practices. Facilities are reducing waste output through waste recycling, and they are using the waste-to-energy techniques to supply cities with the majority of needed energy. The adoption and encouragement of technological advances in waste reduction and energy restoration can lead to a diminished need for hazardous waste treatment plants, and have a significant impact on preserving our resources, protecting the environment, and simultaneously reducing costs over time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Local Impacts of Mercury Emissions from the Three Pennsylvania Coal Fired Power Plants.

The Clean Air Interstate Rule (CAIR) and the Clean Air Mercury Rule (CAMR) as proposed by the U.S. Environmental Protection Agency (EPA) when fully implemented will lead to reduction in mercury emissions from coal-fired power plants by 70 percent to fifteen tons per year by 2018. The EPA estimates that mercury deposition would be reduced 8 percent on average in the Eastern United States. The CAMR permits cap-and-trade approach that requires the nationwide emissions to meet the prescribed level, but do not require controls on each individual power plant. This has led to concerns that there may be hot-spots of mercury contamination near power plants. Partially because of this concern, many states including Pennsylvania have implemented, or are considering, state regulations that are stricter on mercury emissions than those in the CAMR. This study examined the possibility that coal-fired power plants act as local sources leading to mercury 'hot spots'. Soil and oak leaf samples from around three large U.S. coal-fired power plants in Western Pennsylvania were collected and analyzed for evidence of 'hot spots'. These three plants (Conemaugh, Homer City, and Keystone) are separated by a total distance of approximately 30 miles. Each emits over 500 pounds of mercury per year which is well above average for mercury emissions from coal plants in the U.S. Soil and oak leaf sampling programs were performed around each power plant. Sampling rings one-mile apart were used with eight or nine locations on each ring. The prevailing winds in the region are from the west. For this reason, sampling was conducted out to 10 miles from the Conemaugh plant which is southeast of the others. The other plants were sampled to a distance of five miles. The objectives were to determine if local mercury hot spots exist, to determine if they could be attributed to deposition of coal-fired power plant emissions, and to determine if they correlated with wind patterns. The study found the following: (1) There was some correlation between the prevailing wind direction and measured soil and oak leaf concentrations. This correlation was not statistically significant, but higher soil concentrations were generally found in the east and southeast from the plants and lower soil concentrations were found west/southwest from the plants. The prevailing winds are to the east. The Conemaugh plant which was the most southeast of the three plants did have the highest average oak leaf and soil mercury concentrations. Based on emissions, the Keystone plant would be expected to see the highest concentrations as it emitted about 25% more mercury than the other two plants. (2) The results of this study did not turn up strong evidence for large areas (several square miles) of elevated mercury concentrations around the three coal-fired power plants that were tested. This does not mean that there is no effect, there was some evidence of increasing mercury content to the east and south of these plants, however, the trends were not statistically significant suggesting that if the effects exist, they are small.

01 COAL, LIGNITE, AND PEAT↗

Renewable Energy Systems in the Transition of North America to Net Zero Emissions

The North American transition to low-carbon energy sources depends on the technology decisions of its diverse communities and stakeholders. Each region and industry will have its own portfolio of renewable energy technologies to meet the common goal of net zero emissions. Our presentation will share integrated renewable energy solutions being explored at scale by major U.S cities, rural regions dependent on oil and gas, and industries redefining their infrastructure and their missions. Case examples will be presented on: the Los Angeles 100% renewable energy goals; challenges and opportunities of decarbonizing and reducing emissions from the oil and gas industry; repurposing oil and gas infrastructure such as using pipelines for hydrogen blends and renewable natural gas and idle wells for geothermal energy and energy storage; treatment of produced water using renewable energy for agriculture applications; and the preserving water and agricultural resources in the transition to renewable energy. Key challenges will also be discussed, including resilience to increasing disasters, stranded assets, unequal community impact, and meeting the last 5-20% of energy with renewable energy.

challenges↗

National Bio-fuel Energy Laboratory

The National Biofuel Energy Laboratory or NBEL was a consortia consisting of non-profits, universities, industry, and OEM’s. NextEnergy Center (NEC) in Detroit, Michigan was the prime with Wayne State University as the primary subcontractor. Other partners included: Art Van Furniture; Biodiesel Industries Inc. (BDI); Bosch; Clean Emission Fluids (CEF); Delphi; Oakland University; U.S. TARDEC (The Army); and later Cummins Bridgeway. The program was awarded to NextEnergy by U.S. DOE-NREL on July 1, 2005. The period of performance was about five (5) years, ending June 30, 2010. This program was executed in two phases: 1.Phase I focused on bench-scale R&D and performance-property-relationships. 2.Phase II expanded those efforts into further engine testing, emissions testing, and on-road fleet testing of biodiesel using additional types of feedstock (i.e., corn, and choice white grease based). NextEnergy – a non-profit 501(c)(3) organization based in Detroit was originally awarded a $1.9 million grant from the U.S. Dept. of Energy for Phase I of the NBEL program. A few years later, NextEnergy and its partners received an additional $1.9MM in DOE funding to complete Phase II. The NBEL funding was completely exhausted by the program end date of June 30, 2010 and the cost share commitment of 20% minimum has been exceeded nearly two times over. As a result of the work performed by the NBEL consortia, the following successes were realized: 1.Over one hundred publications and presentations have been delivered by the NBEL consortia, including but not limited to: R&D efforts on algae-based biodiesel, novel heterogeneous catalysis, biodiesel properties from a vast array of feedstock blends, cold flow properties, engine testing results (several Society of Automotive Engineers [SAE] papers have been published on this research), emissions testing results, and market quality survey results. 2.One new spinoff company (NextCAT) was formed by two WSU Chemical Engineering professors and another co-founder, based on a novel heterogeneous catalyst that may be retrofitted into idled biodiesel manufacturing facilities to restart production at a greatly reduced cost. 3.Three patents have been filed by WSU and granted based on the NextCAT focus. 4.The next-generation advanced biodiesel dispensing unit (CEF F.A.S.T. unit version 2) was developed by Clean Emission Fluids (CEF). 5.NBEL aided in the preparing a sound technical basis for setting an ASTM B20 standard: ASTM Standard D7467-08 was passed in June of 2008 and officially published on October of 2008. 6.NBEL has helped to understand composition-property-performance relationships, from not only a laboratory and field testing scale, for biodiesel blends from a spectrum of feedstocks. 7.NBEL helped propel the development of biodiesel with improved performance, cetane numbers, cold flow properties, and oxidative stability. 8.Data for over 30,000 miles has been logged for the fleet testing that select members of the consortia participated in. There were five vehicles that participated in the fleet testing. Art Van provided two vehicles, one that remained idle for most of the time and one that was used often for commercial furniture deliveries, Oakland University provided one vehicle, NEC provided one vehicle, and The Night Move provided one vehicle. These vehicles were light to medium duty (2.0 to 6.6 L displacement), used B5 or B20 blends from multiple sources of feedstock (corn-, choice white grease-, and soybean-based blends) and sources (NextDiesel, BDI, or Wacker Oil), experienced a broad range in ambient temperatures (from -9 °F in Michigan winters to 93 °F in the summertime), and both city and highway driving conditions.

09 BIOMASS FUELS↗

Quantification of greenhouse gas emissions from waste management processes for municipalities - A comparative review focusing on Africa

The amount of greenhouse gases (GHG) emitted due to waste management in the cities of developing countries is predicted to rise considerably in the near future; however, these countries have a series of problems in accounting and reporting these gases. Some of these problems are related to the status quo of waste management in the developing world and some to the lack of a coherent framework for accounting and reporting of greenhouse gases from waste at municipal level. This review summarizes and compares GHG emissions from individual waste management processes which make up a municipal waste management system, with an emphasis on developing countries and, in particular, Africa. It should be seen as a first step towards developing a more holistic GHG accounting model for municipalities. The comparison between these emissions from developed and developing countries at process level, reveals that there is agreement on the magnitude of the emissions expected from each process (generation of waste, collection and transport, disposal and recycling). The highest GHG savings are achieved through recycling, and these savings would be even higher in developing countries which rely on coal for energy production (e.g. South Africa, India and China) and where non-motorized collection and transport is used. The highest emissions are due to the methane released by dumpsites and landfills, and these emissions are predicted to increase significantly, unless more of the methane is captured and either flared or used for energy generation. The clean development mechanism (CDM) projects implemented in the developing world have made some progress in this field; however, African countries lag behind.

09 BIOMASS FUELS↗

Advanced Energy Topics for Hill District Community Leaders [Slides]

Through Communities LEAP, a community coalition focused on the Hill District neighborhood of Pittsburgh is working with a technical assistance provider network led by the National Renewable Energy Laboratory (NREL). The coalition includes community organizations, nonprofits, the city government, and the utility. Technical assistance provides analysis and information to support Hill District stakeholders in their goals to create informed residential energy efficiency and renewable energy transition strategies that improve housing conditions and lower energy bills, incorporate energy efficiency and renewable energy strategies into existing, community-driven development efforts, and generate quality local jobs. The Advanced Energy Topics resource is intended to support Hill District community leaders with strategic planning on energy-related topics. The topics included are intended to serve as a technical reference for community leaders to help inform decision-making around energy. The Advanced Energy Topics resource was informed by engagement through the Communities LEAP pilot program with three Hill District Registered Community Organizations: the Hill District Collaborative, the Hill District Consensus Group, and the Hill Community Development Corporation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hi-Q Rotor - Low Wind Speed Technology

The project objective was to optimize the performance of the Hi-Q Rotor. Early research funded by the California Energy Commission indicated the design might be advantageous over state-of-the-art turbines for collecting wind energy in low wind conditions. The Hi-Q Rotor is a new kind of rotor targeted for harvesting wind in Class 2, 3, and 4 sites, and has application in areas that are closer to cities, or 'load centers.' An advantage of the Hi-Q Rotor is that the rotor has non-conventional blade tips, producing less turbulence, and is quieter than standard wind turbine blades which is critical to the low-wind populated urban sites. Unlike state-of-the-art propeller type blades, the Hi-Q Rotor has six blades connected by end caps. In this phase of the research funded by DOE's Inventions and Innovation Program, the goal was to improve the current design by building a series of theoretical and numeric models, and composite prototypes to determine a best of class device. Development of the rotor was performed by aeronautical engineering and design firm, DARcorporation. From this investigation, an optimized design was determined and an 8-foot diameter, full-scale rotor was built and mounted using a Bergey LX-1 generator and furling system which were adapted to support the rotor. The Hi-Q Rotor was then tested side-by-side against the state-of-the-art Bergey XL-1 at the Alternative Energy Institute's Wind Test Center at West Texas State University for six weeks, and real time measurements of power generated were collected and compared. Early wind tunnel testing showed that the cut-in-speed of the Hi-Q rotor is much lower than a conventional tested HAWT enabling the Hi-Q Wind Turbine to begin collecting energy before a conventional HAWT has started spinning. Also, torque at low wind speeds for the Hi-Q Wind Turbine is higher than the tested conventional HAWT and enabled the wind turbine to generate power at lower wind speeds. Based on the data collected, the results of our first full-scale prototype wind turbine proved that higher energy can be captured at lower wind speeds with the new Hi-Q Rotor. The Hi-Q Rotor is almost 15% more productive than the Bergey from 6 m/s to 8 m/s, making it ideal in Class 3, 4, and 5 wind sites and has application in the critical and heretofore untapped areas that are closer to cities, 'load centers,' and may even be used directly in urban areas. The additional advantage of the Hi-Q Rotor's non-conventional blade tips, which eliminates most air turbulence, is noise reduction which makes it doubly ideal for populated urban areas. Hi-Q Products recommends one final stage of development to take the Hi-Q Rotor through Technology Readiness Levels 8-9. During this stage of development, the rotor will be redesigned to further increase efficiency, match the rotor to a more suitable generator, and lower the cost of manufacturing by redesigning the structure to allow for production in larger quantities at lower cost. Before taking the rotor to market and commercialization, it is necessary to further optimize the performance by finding a better generator and autofurling system, ones more suitable for lower wind speeds and rpms should be used in all future testing. The potential impact of this fully developed technology will be the expansion and proliferation of energy renewal into the heretofore untapped Class 2, 3, 4, and 5 Wind Sites, or the large underutilized sites where the wind speed is broken by physical features such as mountains, buildings, and trees. Market estimates by 2011, if low wind speed technology can be developed are well above: 13 million homes, 675,000 commercial buildings, 250,000 public facilities. Estimated commercial exploitation of the Hi-Q Rotor show potential increase in U.S. energy gained through the clean, renewable wind energy found in low and very low wind speed sites. This new energy source would greatly impact greenhouse emissions as well as the public sector's growing energy demands.

17 WIND ENERGY↗

Colorado Better Buildings Project. Final Report

The Colorado Better Buildings project intended to bring new and existing energy efficiency model programs to market with regional collaboration and funding partnerships. The goals for Boulder County and its program partners were to advance energy efficiency investments, stimulate economic growth in Colorado and advance the state’s energy independence. Collectively, three counties set out to complete 9,025 energy efficiency upgrades in 2.5 years and they succeeded in doing so. Energy efficiency upgrades have been completed in more than 11,000 homes and businesses in these communities. Boulder County and its partners received a $25 million BetterBuildings grant from the U.S. Department of Energy under the American Recovery and Reinvestment Act in the summer of 2010. This was also known as the Energy Efficiency and Conservation Block Grants program. With this funding, Boulder County, the City and County of Denver, and Garfield County set out to design programs for the residential and commercial sectors to overcome key barriers in the energy upgrade process. Since January 2011, these communities have paired homeowners and business owners with an Energy Advisor – an expert to help move from assessment to upgrade with minimal hassle. Pairing this step-by-step assistance with financing incentives has effectively addressed many key barriers, resulting in energy efficiency improvements and happy customers. An expert energy advisor guides the building owner through every step of the process, coordinating the energy assessment, interpreting results for a customized action plan, providing a list of contractors, and finding and applying for all available rebates and low-interest loans. In addition to the expert advising and financial incentives, the programs also included elements of social marketing, technical assistance, workforce development and contractor trainings, project monitoring and verification, and a cloud-based customer data system to coordinate among field advisors and across local governments and local service vendors. A portion of the BetterBuildings grant went to the Metro Mayors Caucus (MMC) who worked in partnership with the Denver Regional Council of Governments (DRCOG) to conduct a series of 10 energy efficiency workshops for local government officials and other interested parties. The workshops helped showcase lessons learned on energy efficiency and helped guide other local governments in the establishment of similar programs. The workshops covered a wide range of energy efficiency and renewable energy topics such as clean energy finance, social mobilization and communications, specific case studies of Colorado towns, energy efficiency codes, net zero buildings and solar power. Since the programs launched in January 2011, these communities have collectively spurred economic investments in energy efficiency, achieved greater than 5:1 leveraging of grant funds, saved energy and reduced greenhouse gas emissions, provided trainings for a robust local energy contractor network, and proved out viable and replicable program models that local utilities and other communities are adopting, with long lasting market transformation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

W-SMART Phase-I Pathway Analysis: Case Study - City of Boston, MA

The purpose of this study is to synthesize stakeholder and research learnings to date by exercising PNNL’s Waste - Sustainability Monitoring of Alternative Reuse Options over Time (W-SMART) sustainability protocol for the Greater Boston region. This report serves as a foundation for future discussion and project work to characterize the costs, risks, impacts, tradeoffs, and highest uses for major waste streams. This analysis differs from previous work by 1) incorporating results of a newly completed detailed resource assessment for the Greater Boston area; (2) providing a head-to-head pathway comparison without any policy supports (e.g., carbon or energy credits); and (3) focusing on locally relevant critical waste streams and reuse strategies, by assessing the cost-effectiveness of two complimentary pathways, including (a) expanded incineration of municipal solid waste (MSW) at existing treatment sites to produce baseload electricity, and (b) the conversion of blended municipal wastewater solids (i.e., sludge) and non-residential food waste to produce liquid transportation biofuels at a proposed hydrothermal liquefaction facility in Quincy, MA. The performance of each pathway is also compared to assumed business-as-usual waste management practices as a baseline.

09 BIOMASS FUELS↗

Current Status of Decommissioning Plans and Chemical Decontamination of Metal Scraps in Chinshan NPP - 19304

The decommissioning of nuclear facilities has become a significantly attractive and worldwide topic due to the end of lifetime of many nuclear power plants within next coming years. In Taiwan, Chinshan nuclear power plant owned by the Taiwan Power Company will be the first candidate to be decommissioned according to the Nuclear Reactor Facilities Regulation Act. The Chinshan nuclear power plant located in New Taipei City has two units of 636 MWe boiling water reactors (BWRs) for the generation of 9 billion kWh of electricity per year. The date of cessation of operation of Unit No. 1 and Unit No. 2 will be December in 2018 and July in 2019, respectively. Based on the Regulations for the Review and Approval of Applications for a Decommissioning Permit of Nuclear Reactor Facilities, Taiwan Power Company have submitted a decommissioning plan of Chinshan nuclear power plant to the authority, Atomic Energy Council (AEC). After the review process, the decommissioning plan of Chinshan nuclear power plant has been permitted by AEC in 2017. Decontamination is generally utilized during the period of decommissioning of nuclear facility in order to minimize the radiation exposure of personnel and the cost of management of radioactive wastes. The successful decontamination also probably provides the benefits of lowering the level of radioactive wastes, facilitating potential releases, permitting the reuse of metals and facilitating the radiation principle of As Low As Reasonably Achievable (ALARA) management. Decontamination aims at the removal of radioactive materials from the contaminated surfaces by several technologies such as washing, heating, chemical reaction and mechanical process. The selection of proper decontamination technologies are depended on the requirement of the target materials and the purpose of the decontamination. Chemical decontamination has been proven to be an effective in reducing the radioactivity for metallic materials by using chemical reagents in contact with the contaminated surfaces. During the operation of Chinshan nuclear power plant, chemical decontamination was performed for Unit No.1 and No.2 in 2000 to decontaminate the Reactor Recirculation System (RRS) and Reactor Water Clean-up Systems (RWCU) by using LOMI-NP-LOMI process. Based on the previous experience of chemical decontamination, the dismantled metallic piping is provided as sample by Chinshan nuclear power plant for the evaluation of the feasibility of chemical decontamination. The provided metallic sample is composed of carbon steel with dose rate around 0.2 mSv/hr. In this report, a multistep decontamination process using strongly oxidizing solution and organic acid solution is performed to remove the contaminated oxide layer from the metal surface, and the resulting contact dose rate and decontamination factor (DF) are also shown to discuss the performance in relation to the process control factors. In this paper, the recent progress in decommissioning programs and preliminary results of the decontamination experiment are described to provide usable information regarding the future decommissioning for Chinshan nuclear power plant. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Photovoltaics on Landfills in Puerto Rico

The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Commonwealth of Puerto Rico for a feasibility study of m0treAlables on several brownfield sites. The EPA defines a brownfield as 'a property, the expansion, redevelopment, or reuse of which may be complicated by the presence or potential presence of a hazardous substance, pollutant, or contaminant.' All of the brownfields in this study are landfill sites. Citizens of Puerto Rico, city planners, and site managers are interested in redevelopment uses for landfills in Puerto Rico, which are particularly well suited for solar photovoltaic (PV) installation. The purpose of this report is to assess the landfills with the highest potential for possible solar PV installation and estimate cost, performance, and site impacts of three different PV options: crystalline silicon (fixed-tilt), crystalline silicon (single-axis tracking), and thin film (fixed-tilt). Each option represents a standalone system that can be sized to use an entire available site area. In addition, the report outlines financing options that could assist in the implementation of a system. The feasibility of PV systems installed on landfills is highly impacted by the available area for an array, solar resource, operating status, landfill cap status, distance to transmission lines, and distance to major roads. All of the landfills in Puerto Rico were screened according to these criteria in order to determine the sites with the greatest potential. Eight landfills were chosen for site visits based on the screening criteria and location. Because of time constraints and the fact that Puerto Rico is a relatively large island, the eight landfills for this visit were all located in the eastern half of the island. The findings from this report can be applied to landfills in the western half of the island. The economics of a potential PV system on landfills in Puerto Rico depend greatly on the cost of electricity. Currently, PREPA has an average electric rate of $0.119/kWh. Based on past electric rate increases in Puerto Rico and other islands in the Caribbean, this rate could increase to $0.15/kWh or higher in a relatively short amount of time. In the coming years, increasing electrical rates and increased necessity for clean power will continue to improve the feasibility of implementing solar PV systems at these sites.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling Amorphization and Compositional Optimization of Ternary Metal Phosphides toward High-Performance Electrocatalytic Hydrogen Production

Amorphous materials, with abundant active sites and unique electronic configurations, have the potential to outperform their crystalline counterparts in high-performance catalysis for clean energy. However, their synthesis and compositional optimization remain underexplored due to the strict conditions required for their formation. Here, in this study, we report the synthesis of ternary platinum-nickel-phosphorus (PtNiP) amorphous nanoparticles (ANPs) within milliseconds by flash Joule heating, which features ultrafast cooling that enables the vitrification of metal precursors. Through compositional optimization, the Gibbs free energy of hydrogen adsorption for Pt 4 Ni 4 P 1 ANPs is optimized at 0.02 eV, an almost ideal value, even surpassing that of the benchmark metallic platinum catalyst. As a result, the PtNiP ANPs exhibited superior activity in electrocatalytic hydrogen evolution in acid electrolyte (η 10 ∼ 14 mV, Tafel slope ∼ 18 mV dec –1 , and mass activity 5× higher than state-of-the-art Pt/C). Life-cycle assessment and technoeconomic analysis suggest that, compared to existing processes, our approach enables notable reductions in greenhouse gas emission, energy consumption, and production cost for practical electrolyzer catalyst manufacturing.

36 MATERIALS SCIENCE↗

SAFSTOR and License Renewal: Making Them Coexist

The Indian Point Energy Center is located on the eastern shore of the Hudson River in the town of Buchanan, New York. It lies approximately thirty miles north of New York City, and thus, holds the distinction of being the closest nuclear facility to a major metropolitan area. Units 1 and 2 were constructed and operated by Consolidated Edison and Unit 3 was owned and operated by the New York State Power Authority. All three units are now owned and operated by Entergy Nuclear- Northeast. Indian Point Unit 1 was powered by a pressurized water reactor which operated with an authorized maximum steady state power level of 615 thermal megawatts until October 31, 1974. On June 19, 1980, the Commission issued an order revoking authority to operate the facility. Although 244 spent fuel assemblies were successfully shipped offsite to a spent fuel reprocessing facility, 160 assemblies remain in the Unit 1 spent fuel pool awaiting relocation to dry cask storage. Units 2 and 3 are also pressurized water reactors which each produce slightly in excess of 1,000 MWe. Since 1974, Unit 1 has been maintained in a Safe Store Mode (SAFSTOR). For the purposes of this document, the term 'SAFSTOR' is intended to mean 'Custodial SAFSTOR' as described in section 2.4.3 of NUREG 0586 (Final Generic Environmental Impact Statement on Decommissioning of Nuclear Facilities (GEIS) as follows: 'Custodial SAFSTOR requires a minimum cleanup and decontamination effort initially, followed by a period of continuing care with the active protection systems (principally the ventilation system) kept in service throughout the storage period. Full-time onsite surveillance by operating and security forces is required to carry out radiation monitoring, to maintain the equipment, and to prevent accidental or deliberate intrusion into the facility and the subsequent exposure to radiation or the disposal of radioactivity beyond the confines of the facility'. The decision to enter SAFSTOR was based upon the immediate proximity of Unit 1 to the operating units and the fact that a number of Unit 1 systems are shared with Unit 2. Over the past few decades, additional Unit 1 space (primarily within the turbine building) has been cleaned out and is being used to support the operating Units. The original plan to maintain Unit 1 in a SAFSTOR condition until it could be safely dismantled along with Unit 2 at the end of the Unit 2 operating license in 2012, requires some level of re-thinking now that Units 2 and 3 are applying for renewal of their licenses with the desire to continue operation until the 2033 time frame. The remainder of this paper summarizes the inspections and assessments undertaken by Entergy to investigate and document the condition of Indian Point Unit 1 and the resulting steps taken to assure that it would not pose a threat to the license extension efforts being under taken by Units 2 and 3. In conclusion: the Entergy Indian Point management team has systematically undertaken an effort to ensure the Unit 1 SAFSTOR condition and has implemented programs and procedural controls which will assure that it will continue to be safely maintained and will not impact the continued safe operation of Units 2 and 3 during their license renewal period.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ductless Heat Pump Energy Monitoring in a Cold Climate

In 2018, the City and Borough of Juneau, Alaska set the goal of reaching 80% renewable energy for heating and transportation by 2045. An important factor to help reach this goal is finding energy efficiency home heating technologies such as ductless air source heat pumps (DHPs), which rely on the local hydropower electric grid to provide space heating for an entire home or a main living area. To help residents reduce energy costs and move toward the community renewable energy goal, a team of local, state, and national partners joined to run Thermalize Juneau 2021, an energy campaign that provided education, a simplified installation process, and a bulk purchase discount. Overall, the campaign enrolled 165 participants, resulting in 75 DHP installations and over 30 energy efficiency improvements. To evaluate the reliability and energy use of the DHPs installed during the Thermalize Juneau campaign, researchers installed energy monitors on heat pumps of 14 participants and conducted interviews with homeowners. Data from two heating seasons (2021-2022 and 2022-2023) has allowed researchers to examine the accuracy of pre-campaign energy savings predictions, establish energy savings for a small group of households, and provide insights on the energy use and occupant satisfaction of DHPs which will help to inform future heat pump deployment efforts in the area.

air source heat pump↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Ductless Heat Pump Energy Monitoring in a Cold Climate

In 2018, the City and Borough of Juneau, Alaska, set the goal of reaching 80% renewable energy for heating and transportation by 2045. An important factor to help reach this goal is energy-efficient home heating technologies such as ductless air- source heat pumps (DHPs), which rely on the local hydropower electric grid to provide space heating for an entire home or a main living area. To help residents reduce energy costs and move toward the community renewable energy goal, a team of local, state, and national partners joined together to run Thermalize Juneau 2021, an energy campaign that provided education, a simplified installation process, and a bulk purchase discount. Overall, the campaign enrolled 165 participants, resulting in 75 DHP installations and over 30 other energy efficiency improvements. To evaluate the reliability and energy use of the DHPs installed during the Thermalize Juneau campaign, researchers installed energy monitors on heat pumps of 14 participants and conducted interviews with homeowners. Data from two heating seasons (2021-2022 and 2022-2023) allowed researchers to examine the accuracy of pre-campaign energy savings predictions, establish energy savings for a small group of households, and provide insights on the energy use and occupant satisfaction of DHPs, which will help inform future heat pump deployment efforts in the area.

air source heat pump↗

Energy Impact of Radiative Cooling Paints in Warehouses Under Various United States Climates

Although radiative cooling research is widely found in the literature, no comprehensive study has yet been conducted on the impact of novel radiant cooling (>0.91 reflectance) on the energy efficiency of warehouses. Here, in this work, we develop three building models based on a Department of Energy prototype warehouse model using trnsys, representing a typical warehouse with a black roof, a typical warehouse with a white roof, and a warehouse with novel radiative cooling (RC) paint on its roof. These models are run for 15 different cities, each representative of a different ASHRAE climate zone, to better understand the impact of RC in many different climates. It was found that an RC-coated roof in a warehouse could reduce the building's annual heating, ventilation, and air conditioning (HVAC) loads by up to 14.11 kWh/m 2 of the roof area compared to a black roof, resulting in a maximum reduction in energy costs of 0.55 $\$$/m 2 or $\$$2646/year for a large 4835 m 2 warehouse. Similarly, replacing the typical white roof coating with an RC coating could reduce the warehouse's energy consumption by up to 8.17 kWh/ m 2 of roof area, thus reducing energy costs by as much as 0.29 $\$$/m 2 or $\$$1386/year for a 4835 m 2 warehouse. In addition, applying RC paint to an unconditioned warehouse could reduce the building's ASHRAE Standard 55 indoor temperature exceedance by up to 1330 h/year compared to a black roof and up to 532 h/year compared to a white roof.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemical Cycling of Liquid Organic Hydrogen Carriers as a Sustainable Approach for Hydrogen Storage and Transportation

Hydrogen (H 2 ), as a high-energy-density molecule, offers a clean solution to carry energy. However, the high diffusivity and low volumetric density of H 2 pose a challenge for long-term storage and transportation. Liquid organic hydrogen carriers (LOHCs) have been suggested as a strategic way to store and transport hydrogen in stable molecules. More so, electrochemical LOHC cycling renders an opportunity to utilize renewable energy for hydrogen storage and transportation toward the goal of eliminating carbon emissions. In this Perspective, examples of electrochemical reactions of organic molecules and their suitability for LOHC couples are examined. A comparative carbon footprint assessment of electrochemical LOHC cycling processes against thermochemical and hybrid LOHC cycling processes was performed. The electrochemical LOHC cycling process had the lowest relative carbon footprint only when highly concentrated LOHCs were used as the feed or when purification of the LOHC product was not required. The carbon footprint in electrochemical cycling of diluted LOHC was primarily contributed to by the LOHC distillation separation process. A sensitivity analysis showed the carbon footprint LOHC concentration dependence during the electrochemical cycling process. Moreover, the electrolyte composition significantly affects the carbon footprint during electrochemical LOHC cycling. Energy utilization, water usage, and toxicity for electrochemical LOHC cycling are discussed to provide an overview for better economic and environmental practices. There are significant opportunities in the electrochemical cycling of LOHCs if appropriate conditions such as high concentrations of reactant, reversible redox cycling ability, high Faradaic efficiencies, and catalyst stabilities are achieved.

25 ENERGY STORAGE↗