Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Charge coupled devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Chemical abundance of comets

Observations of NH2, (OI) and molecular ion spectra in comets represent virtually all of the volatile fraction of a comet nucleus. Their study leads to the N2, NH3, H2O, CO2, CO content of the nucleus, and thus to important constraints on models of comet formation and chemical processing in the primitive solar nebula. The observations of Comet Halley provide the opportunity for the first comprehensive determination of the abundances in a comet nucleus. The carbon isotope abundance ratio 12 C/13 C = 65 plus or minus 8 has been determined for Comet Halley from resolved rotational line structure in the CN B-X (0,0) band. The ratio is approximately 30 pct lower than the solar system value, 89, indicating either an enhancement of 13CN or a depletion of 12CN in the comet. Scenarios consistent with the observed carbon isotope ratio are: (1) formation of the comet at the periphery of the solar nebula in a fractionation-enriched 13CN region, or hidden from 12CN enrichment sources, and (2) capture of an interestellar comet. Long-slit charge coupled device (CCD) spectra obtained at the time of the spacecraft encounter of Comet Halley have also been analyzed. Scale lengths, production rates and column densities of CH, CN, C2 and NH2 were determined.

Wyckoff, Susan↗

A Normal Incidence X-ray Telescope (NIXT) sounding rocket payload

Work on the High Resolution X-ray (HRX) Detector Program is described. In the laboratory and flight programs, multiple copies of a general purpose set of electronics which control the camera, signal processing and data acquisition, were constructed. A typical system consists of a phosphor convertor, image intensifier, a fiber optics coupler, a charge coupled device (CCD) readout, and a set of camera, signal processing and memory electronics. An initial rocket detector prototype camera was tested in flight and performed perfectly. An advanced prototype detector system was incorporated on another rocket flight, in which a high resolution heterojunction vidicon tube was used as the readout device for the H(alpha) telescope. The camera electronics for this tube were built in-house and included in the flight electronics. Performance of this detector system was 100 percent satisfactory. The laboratory X-ray system for operation on the ground is also described.

Golub, Leon↗

A programmable CCD driver circuit for multiphase CCD operation

A programmable CCD (charge-coupled device) driver circuit was designed to drive CCDs in multiphased modes. The purpose of the drive electronics is to operate developmental CCD imaging arrays for NASA's tiltable moderate resolution imaging spectrometer (MODIS-T). Five objectives for the driver were considered during its design: (1) the circuit drives CCD electrode voltages between 0 V and +30 V to produce reasonable potential wells, (2) the driving sequence is started with one input signal, (3) the driving sequence is started with one input signal, (4) the circuit allows programming of frame sequences required by arrays of any size, (5) it produces interfacing signals for the CCD and the DTF (detector test facility). Simulation of the driver verified its function with the master clock running up to 10 MHz. This suggests a maximum rate of 400,000 pixels/s. Timing and packaging parameters were verified. The design uses 54 TTL (transistor-transistor logic) chips. Two versions of hardware were fabricated: wirewrap and printed circuit board. Both were verified functionally with a logic analyzer.

Ewin, Audrey J.↗

Digital optical spark chambers

The authors constructed and tested a prototype digital readout system for optical spark chambers using a linear, solid-state charge-coupled-device detector array. Position resolution of 0.013 mm (sigma) over a 25-cm field of view has been demonstrated. It is concluded that this technique should permit the construction of economical, lightweight and low-power trajectory hodoscopes for use in cosmic-ray instrumentation on balloons and in spacecraft.

Evenson, Paul↗

Monitoring Both Sides Of A Weld In Progress

Proposed remote vision system provides simultaneous viewing of front and back of workpiece while being welded. Enables human or automatic controller to monitor both weld pool on front and weld penetration on back. Nitrogen laser generates ultraviolet light, distributed to both sides of workpiece through two optical fiber cables. Image-intensifier tubes convert reflected ultraviolet light to visible light. Video cameras equipped with high-resolution charge-coupled devices convert visible outputs of image intensifiers into images for viewing on video monitors.

Dickinson, C. B.↗

Processing Laser-Velocimetric Data By Vector Scanning

Velocity plots obtained in minutes instead of hours. Velocity scanning technique for processing flow-field data from pulsed-laser-velocimetry images into two-dimensional velocity-vector maps. Requires no special equipment other than charge-coupled-device (CCD) camera, circuitry to digitize output of camera, and computer. Once image data digitized, all processing done in computer.

Wernet, Mark P.↗

Multi-Quantum-Well Spatial Light Modulators On Si Substrates

Proposed new class of two-dimensional spatial light modulators (SLM's) based on fabrication of multi-quantum-well (MQW) structures (e.g. of AlGaAs and InGaAs) on silicon substrates. Concept makes two-dimensional SLM arrays by taking advantage of mature technology of silicon charge-coupled devices (CCD's). Features include short response times, high resolution, and low switching energies.

Cutts, James A.↗

The detection of soft X-rays with charged coupled detectors

The characteristics of an ideal soft X-ray imaging detector are enumerated. Of recent technical developments the CCD or charge coupled device goes furthest to meeting these requirements. Several properties of CCDs are described with reference to experimental work and their application to practical instruments is reviewed.

Burstein, P.↗

Spectrophotometric observations of comet P/Giacobini-Zinner

Spectroscopic observations of the Giacobini-Zinner comet were performed on March 20, June 20 and 21, September 11, and October 19, 1985. The September observations were performed at perihelion, exactly at the time of the International Cometary Explorer (ICE) encounter with the comet. The March and June observations were obtained with an intensified image dissector scanner (IIDS) on the 2.1-meter Kitt Peak telescope and the September and the October observations were obtained with a charge-coupled device (CCD) on the 4-meter Kitt Peak telescope. The nucleus spectra from these observations are presented.

Konno, I.↗

Space environment robot vision system

A prototype twin-camera stereo vision system for autonomous robots has been developed at Goddard Space Flight Center. Standard charge coupled device (CCD) imagers are interfaced with commercial frame buffers and direct memory access to a computer. The overlapping portions of the images are analyzed using photogrammetric techniques to obtain information about the position and orientation of objects in the scene. The camera head consists of two 510 x 492 x 8-bit CCD cameras mounted on individually adjustable mounts. The 16 mm efl lenses are designed for minimum geometric distortion. The cameras can be rotated in the pitch, roll, and yaw (pan angle) directions with respect to their optical axes. Calibration routines have been developed which automatically determine the lens focal lengths and pan angle between the two cameras. The calibration utilizes observations of a calibration structure with known geometry. Test results show the precision attainable is plus or minus 0.8 mm in range at 2 m distance using a camera separation of 171 mm. To demonstrate a task needed on Space Station Freedom, a target structure with a movable I beam was built. The camera head can autonomously direct actuators to dock the I-beam to another one so that they could be bolted together.

Wood, H. John↗

Optical rate sensor algorithms

Optical sensors, in particular Charge Coupled Device (CCD) arrays, will be used on Space Station to track stars in order to provide inertial attitude reference. Algorithms are presented to derive attitude rate from the optical sensors. The first algorithm is a recursive differentiator. A variance reduction factor (VRF) of 0.0228 was achieved with a rise time of 10 samples. A VRF of 0.2522 gives a rise time of 4 samples. The second algorithm is based on the direct manipulation of the pixel intensity outputs of the sensor. In 1-dimensional simulations, the derived rate was with 0.07 percent of the actual rate in the presence of additive Gaussian noise with a signal to noise ratio of 60 dB.

Uhde-Lacovara, Jo A.↗

Video camera system for locating bullet holes in targets at a ballistics tunnel

A system consisting of a single charge coupled device (CCD) video camera, computer controlled video digitizer, and software to automate the measurement was developed to measure the location of bullet holes in targets at the International Shooters Development Fund (ISDF)/NASA Ballistics Tunnel. The camera/digitizer system is a crucial component of a highly instrumented indoor 50 meter rifle range which is being constructed to support development of wind resistant, ultra match ammunition. The system was designed to take data rapidly (10 sec between shoots) and automatically with little operator intervention. The system description, measurement concept, and procedure are presented along with laboratory tests of repeatability and bias error. The long term (1 hour) repeatability of the system was found to be 4 microns (one standard deviation) at the target and the bias error was found to be less than 50 microns. An analysis of potential errors and a technique for calibration of the system are presented.

Burner, A. W.↗

Three-Dimensional Acousto-Optical Spectrum Analyzer

Experimental acousto-optical Bragg-cell spectrum analyzer achieves subhertz frequency resolution. System represents extension to three dimensions of two-dimensional spectrum-analyzer concept described in, "Two-Dimensional Acousto-Optical Spectrum Analyzer" (NPO-18092). First and second dimensions two spatial dimensions of charge-coupled-device (CCD) imaging array. Third dimension time, as sampled at frame rate of CCD array.

Ansari, Homayoon↗

Ir/IrSi3/Si Schottky-Barrier Infrared Detector

Quantum efficiency increased. Proposed Schottky-barrier infrared detector has double metallic layer of Ir and IrSi3 instead of single metallic layer of Ir, IrSi, or IrSi3. Offers advantages of both relatively high infrared absorption in thin film of Ir and stability and reproducibility of layer of IrSi3 in contact with Si. Also serves as barrier to chemical reactions between Ir overlayer and Si substrate. Detectors used to form focal-plane array integrated with charge-coupled-device-addressing and image-processing circuitry.

Lin, True-Lon↗

Imaging spectrophotometry of the nuclear outflow of NGC 1068

This observational program (in conjunction with R. B. Tully (IfA, Honolulu), and J. Bland (Rice U., Houston)) aims to constrain the kinematic organization and dominant excitation mechanisms of ionized gas in active galaxies. More generally, researchers are interested in the dynamics of radiative, supersonic flows in the Interstellar Medium (ISM). Imaging Fabry-Perot interferometers and low-noise Charge Coupled Devices (CCDs) are used for complete spatial coverage of the complex gas distribution in circumnuclear narrow-line regions (NLRs). Extranuclear emission line widths in NLRs can exceed 3000 km s(-1), so to avoid inter-order confusion researchers use an etalon of 4000 km s(-1) free spectral range to map (N II) lambda lambda 6548, 6583 and H alpha. To maximize spatial resolution, researchers select nearby active systems independent of luminosity but known to possess interesting morphologies and/or high-velocity extranuclear ionized gas. Monochromatic images Full Width Half Maximum (FWHM) approx. 65 km s(-1) have thus far been obtained in 1 second or better seeing at the U. Hawaii 2.2m, CFH 3.6m, and CTIO 4.0m telescopes. These are stacked into grids of line profiles, of spectrophotometric quality, at sub-arcsecond increments across a 3 second field. To handle the approx. 20,000 to 300,000 useful spectra that arise from a typical night's work, researchers have developed a complete analysis and reduction package for VAX and Sun image workstations. Reduction involves parametrization of approx. 10 to the 8th raw data points to a few maps (e.g., velocities of each kinematic subsystem, continuum-free line fluxes) containing approx. 10 to the 5th pixels. Researchers identify kinematic and structural symmetries by examining these maps and the point to point variations of the synthesized line profiles. The combination of monochromatic images and full spatial sampling of line profiles has allowed them to isolate such symmetries and has led to reliable kinematic deprojections.

Cecil, Gerald↗

HII regions in dwarf irregular galaxies of the local group

Deep, narrowband H alpha Charge Coupled Device (CCD) surveys of HII regions were carried out in several dwarf irregular galaxies in and near the local group. Data are now complete for these galaxies: NGC 6822, GR 8, IC 10, IC 1613, Sextans A, Sextans B, and Sag Irr. Observations are complete for DDO 47, 53, 167, 168 and 187. Details of some of the results for the surveys completed so far are discussed. For NGC 6822, CCD survey at H alpha resulted in the detection of 145 HII regions in the local group irregular galaxy NGC 6822. Most of them are newly detected, faint surface-brightness objects. Positions, maps and dimensions are being published elsewhere. For GR 8, a deep narrowband H alpha imaging of the nearby dwarf irregular galaxy GR 8 revealed a total of 32 HII regions. Positions, H alpha luminosities, and sizes of these objects were determined. The H alpha luminosity function has the same shape as that for more luminous galaxies, except for size of sample effects. Most HII regions detected are at the very low luminosity end of the general luminosity function. For IC 10, a deep CCD narrowband H alpha imaging of the local group dwarf irregular galaxy IC 10 revealed a total of 144 HII regions. Positions, H alpha luminosities, and sizes of these objects were determined. The H alpha luminosity function has the same shape as that for more luminous galaxies.

Hodge, Paul↗

HII regions in IC 1613: The ISM in a nearby dwarf irregular galaxy

IC 1613, a nearby (725 kpc distant) dwarf irregular galaxy, has always been known to contain large, ring-shaped HII regions in its northeast corner. A new H alpha image has been obtained using the Bell Labs Charge Coupled Device (CCD) camera, an RCA 320 X 512 pixel-thinned, back-illuminated CCD, an H alpha filter of central wavelength 6562 A and width (full width half maximum) of 30 A, and the 42 inch telescope at Lowell Observatory. The low resolution images exhibit many new, faint features.

Price, Jill S.↗