Washington River Protection Solutions is working on a Tank-Side Cesium Removal (TSCR) system to remove Cs from Hanford tank waste supernate. Removal of 137 Cs from tank waste supernate by TSCR results in a low-activity waste (LAW) form that can be fed directly to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW vitrification facility, where the supernate can be vitrified into a glass form. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV TM R9140-B), was selected for use as the ion exchange media to remove Cs at TSCR. The particle size used in testing is expected to impact the kinetic performance of the ion exchange media. Therefore, two single-column systems were tested with CST Lot 2002009604. One column contained <25 mesh sieve cut fraction and the other column contained <35 mesh sieve cut fraction. Flowrate through both test systems was adjusted to match the CST contact time expected for the full-scale operation, i.e., matched bed volumes per hour (BV/h) at 1.83 BV/h. The feed was processed downflow through the columns until ~1000 BVs of feed were processed. The waste acceptance criteria (WAC) limit for the WTP LAW vitrification facility is <3.18E-5 Ci 137 Cs per mole Na. For a tank waste containing 156 µCi/mL 137 Cs and 5.6 M Na, up to 0.114% of the influent 137 Cs concentration may be delivered to the WTP (based on 137 Cs content in AP-107 tank waste); this required a Cs decontamination factor of 876. The WAC limit was used as one of the relevant process parameters, along with the 50% breakthrough point, Cs loading per gram of CST, and the mass transfer zone.