Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capillary Pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Solute rejection by porous glass membranes. I - Hyperfiltration of sodium chloride and urea feed solutions.

Hyperfiltration of sodium chloride and urea was studied with porous glass membranes in closed-end capillary form, to determine the effect of pressure, temperature, and concentration variations, and lifetime rejection and flux characteristics. Rejection data for sodium chloride were consistent with the functioning of the porous glass as a low-capacity ion-exchange membrane.

Ballou, E. V.↗

Centaur propellant thermal conditioning system

An upgraded Centaur capability was studied by investigating three main areas: (1) Analytical and experimental investigation of promising capillary pumping concepts for passive cooling of cryogenic capillary acquisition devices resulted in selection, test, and empirical correlation of four wicking configurations. Only plate/screen-screen/plate and plate/screen-plate/screen configurations would function successfully under worst-case Centaur D-1S conditions. Weight estimates were developed for the passively cooled configurations and comparisons were made of passive and actively cooled capillary devices. (2) Thermal subcoolers for replacing pressurization and boost pump systems for three engine candidates and three Centaur D-1S missions were evaluated for several feed system configurations. Analysis included both transient and steady-state operation. Weight comparisons were made among feed system alternatives. (3) Existing experimental mixing studies to destroy thermal stratification were evaluated to determine the best mixing correlation to fit all available data. The correlation was then used to modify a computer program to size thermodynamic vent systems for Shuttle-based Centaur derivatives.

Blatt, M. H.↗

Incorporating high-pressure electroosmotic pump and a nano-flow gradient generator into a miniaturized liquid chromatographic system for peptide analysis

Here we integrate a high-pressure electroosmotic pump (EOP), a nanoflow gradient generator, and a capillary column into a miniaturized liquid chromatographic system that can be directly coupled with a mass spectrometer for proteomic analysis. We have recently developed a low-cost high-pressure EOP capable of generating pressure of tens of thousands psi, ideal for uses in miniaturized HPLC. The pump worked smoothly when it was used for isocratic elutions. When it was used for gradient elutions, generating reproducible gradient profiles was challenging; because the pump rate fluctuated when the pump was used to pump high-content organic solvents. This presents an issue for separating proteins/peptides since high-content organic solvents are often utilized. In this work, we solve this problem by incorporating our high-pressure EOP with a nano-flow gradient generator so that the EOP needs only to pump an aqueous solution. With this combination, we develop a capillary-based nano-HPLC system capable of performing nano-flow gradient elution; the pump rate is stable, and the gradient profiles are reproducible and can be conveniently tuned. Finally, to demonstrate its utility, we couple it with either a UV absorbance detector or a mass spectrometer for peptide separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quasi non-intrusive sampling and analysis of gases associated with the boundary layer on the tethered satellite and similar supersonic and hypersonic research vehicles

The effect that one candidate inlet, an assembly of capillary openings in a thin glass plate (a multichannel plate), might have on the overall sampling process is considered. The flow characteristics of the plate, under a variety of conditions of external pressure and mass flow, is evaluated. A review of capillary flow theory is presented with some development of the pertinent equations. The predicted mass flow will be compared to that determined perimentally to assess the effect that mass flow through one capillary might have upon a neighboring capillary. Mass spectrometric measurements of mixtures flowing through the multichannel plate (MCP) is also considered. In the first part of the experiments, the flow was in a direction normal to the surface of the plate. The experimental gases were Argon and mixtures of carbon dioxide in air. Ongoing experiments are discussed which are conducted with the flow parallel to the surface of the plate, a simulation of the kind of flow that a flight vehicle would experience.

Fishel, C.↗

Xenon excimer emission from multicapillary discharges in direct current mode

Microdischarges in xenon have been generated in a pressure range of 400-1013 mbar with a fixed flow rate of 100 sccm. These microdischarges are obtained from three metallic capillary tubes in series for excimer emission. Total discharge voltage is thrice as large as that of a single capillary discharge tube at current levels of up to 12 mA. Total spectral irradiance of vacuum ultraviolet (VUV) emission also increases significantly compared to that of the single capillary discharge. Further, the irradiance of the VUV emission is strongly dependent on pressure as well as the discharge current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploding Wire in Water as a Potential Source of Amplified EUV-radiation

Proximity wall stabilized, fast (>4x10{sup 11} A/s), high current (>40 kA) discharges are capable to create long, dense, hot, 'stable,' non-equilibrium plasma column suitable e.g. for amplification of EUV and soft X-ray radiation. Exploding wire in water resembles a metal-vapor-filled capillary with liquid, ever fresh wall (without any metallic deposit). Modeling of wire explosion (inclusive melting and boiling phase transitions, thermal diffusion, and non-constant conductivity) by the originally skinned driving current is described. Modeling results are compared with measurement of the discharge current and with side-on monitoring of H-alpha line emission. The differences are attributed to the fact that for calculation the material constants measured at atmospheric pressure were available only.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compartment syndromes

The compartment syndrome is defined as a condition in which high pressure within a closed fascial space (muscle compartment) reduces capillary blood perfusion below the level necessary for tissue viability'. This condition occurs in acute and chronic (exertional) forms, and may be secondary to a variety of causes. The end-result of an extended period of elevated intramuscular pressure may be the development of irreversible tissue injury and Volkmann's contracture. The goal of treatment of the compartment syndrome is the reduction of intracompartmental pressure thus facilitating reperfusion of ischaemic tissue and this goal may be achieved by decompressive fasciotomy. Controversy exists regarding the critical pressure-time thresholds for surgical decompression and the optimal diagnostic methods of measuring intracompartmental pressures. This paper will update and review some current knowledge regarding the pathophysiology, aetiology, diagnosis, and treatment of the acute compartment syndrome.

NASA Discipline Cardiopulmonary↗

Study of liquid and vapor flow into a Centaur capillary device

The following areas of liquid and vapor flow were analyzed and experimentally evaluated; 1) the refilling of capillary devices with settled liquid, and 2) vapor flow across wetted screens. These investigations resulted in: 1) the development of a versatile computer program that was successfully correlated with test data and used to predict Centaur D-1S LO2 and LH2 start basket refilling; 2) the development of a semi-empirical model that was only partially correlated with data due to difficulties in obtaining repeatable test results. Also, a comparison was made to determine the best propellant management system for the Centaur D-1S vehicle. The comparison identified the basline Centaur D-1S system (using pressurization, boost pumps and propellant settling) as the best candidate based on payload weight penalty. However, other comparison criteria and advanced mission condition were identified where pressure fed systems, thermally subcooled boost pumps and capillary devices would be selected as attractive alternatives.

Blatt, M. H.↗

Laser schlieren deflectometry for temperature analysis of filamentary non-thermal atmospheric pressure plasma

The heat convection generated by micro filaments of a self-organized non-thermal atmospheric pressure plasma jet in Ar is characterized by employing laser schlieren deflectometry (LSD). It is demonstrated as a proof of principle, that the spatial and temporal changes of the refractive index n in the optical beam path related to the neutral gas temperature of the plasma jet can be monitored and evaluated simultaneously. The refraction of a laser beam in a high gradient field of n(r) with cylindrical symmetry is given for a general real refraction index profile. However, the usually applied Abel approach represents an ill-posed problem and in particular for this plasma configuration. A simple analytical model is proposed in order to minimize the statistical error. Based on that, the temperature profile, specifically the absolute temperature in the filament core, the FWHM, and the frequencies of the collective filament dynamics are obtained for non-stationary conditions. For a gas temperature of 700 K inside the filament, the presented model predicts maximum deflection angles of the laser beam of 0.3 mrad which is in accordance to the experimental results obtained with LSD. Furthermore, the experimentally obtained FWHM of the temperature profile produced by the filament at the end of capillary is (1.5 {+-} 0.2) mm, which is about 10 times wider than the visual radius of the filament. The obtained maximum temperature in the effluent is (450 {+-} 30) K and is in consistence with results of other techniques. The study demonstrates that LSD represents a useful low-cost method for monitoring the spatiotemporal behaviour of microdischarges and allows to uncover their dynamic characteristics, e.g., the temperature profile even for challenging diagnostic conditions such as moving thin discharge filaments. The method is not restricted to the miniaturized and self-organized plasma studied here. Instead, it can be readily applied to other configurations that produce measurable gradients of refractive index by local gas heating and opens new diagnostics prospects particularly for microplasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design optimization of gap distance for the capillary limitation of a heat pipe with annular-type wick structure

In this study, an experimental investigation was conducted on the rising height and contact angle of fluid in an annular wick-type heat pipe. The annular wick-type heat pipe was characterized by a small gap between the wick structure and tube wall, which compensated for the pressure drop along the porous media and created additional capillary force. To describe and model the advantage of this gap, the rising of a wetting liquid in the gap between a vertical solid plate and a mesh (with a small angle between them) was experimentally measured and analyzed. An additional experiment was performed to investigate the effect of curvature on the capillary rise using tubes and meshes of varying radii. Resultantly, we confirmed that the linear combination of the contact angles of the solid plate and mesh could be applied to calculate the rising height from the Laplace–Young equation. Furthermore, the effect of curvature on the rising height of the liquid was negligible. These results were extended to the investigation of finding the optimal gap distance for the annular wick-type heat pipe by referring to previous studies. We observed that a gap distance of 1.27 mm provided the largest permeability (K) over the effective pore radius (r eff ) value for a heat pipe with ethanol, which in turn resulted in the highest capillary limitation. For a sodium heat pipe, a gap distance of 0.84 mm resulted in the highest capillary limitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal Integration of a Liquid Acquisition Device into a Cryogenic Feed System

Primary objectives of this effort were to define the following: (1) Approaches for quantification of the accumulation of thermal energy within a capillary screen liquid acquisition device (LAD) for a lunar lander upper stage during periods of up to 210 days on the lunar surface, (2) techniques for mitigating heat entrapment, and (3) perform initial testing, data evaluation. The technical effort was divided into the following categories: (1) Detailed thermal modeling of the LAD/feed system interactions using both COMSOL computational fluid device and standard codes, (2) FLOW-3D modeling of bulk liquid to provide interfacing conditions for the LAD thermal modeling, (3) condensation conditioning of capillary screens to stabilize surface tension retention capability, and (4) subscale testing of an integrated LAD/feed system. Substantial progress was achieved in the following technical areas: (1) Thermal modeling and experimental approaches for evaluating integrated cryogen LAD/feed systems, at both the system and component levels, (2) reduced gravity pressure control analyses, (3) analytical modeling and testing for capillary screen conditioning using condensation and wicking, and (4) development of rapid turnaround testing techniques for evaluating LAD/feed system thermal and fluid integration. A comprehensive effort, participants included a diverse cross section of representatives from academia, contractors, and multiple Marshall Space Flight Center organizations.

Hastings, L. J.↗

Transient behavior of a supersonic three-dimensional micronozzle with an intersecting capillary

An analysis of the interaction between a pulsed, supersonic microjet and an intersecting gas-filled capillary is presented, which enables a direct measurement of the pressure evolution inside the nozzle of the microjet. Plasma-emission spectroscopy was used to resolve, on a sub-microsecond timescale, the build-up and decay of pressure in the nozzle, which are shown to be correlated to the volume of the plenum supplying the nozzle and to the nozzle-throat size, respectively. The microjet, which was integrated with a capillary-discharge waveguide in a sapphire structure, was used to create a small, tunable region of high density gas within a centimeter-scale plateau of lower-density for use in a laser-plasma accelerator. The resultant longitudinally structured gas-density profile has been used to provide control of electron trapping and acceleration, but its evolution has not previously been directly quantified. Overall, the results presented here pave the way for improved control of laser-plasma accelerators and are also relevant to applications such as miniature satellites and lab-on-a-chip where precise knowledge of microjet pressure evolution is critical.

47 OTHER INSTRUMENTATION↗

Effect of Stepwise Pressure Change on Porosity Evolution during Directional Solidification in Small Cylindrical Channels

Controlled directional solidification experiments were performed in capillary channels, using nitrogen-saturated succinonitrile, to examine the effect of an in-situ stepwise processing pressure increase on an isolated pore evolution. Two experiments were performed using different processing pressure input profiles. The results indicate that a processing pressure increase has a transient effect on pore growth geometry characterized by an initial phase of decreasing pore diameter, followed by a recovery phase of increasing pore diameter. The experimental results also show that processing pressure can be used as a control parameter to either increase or terminate porosity formation. A theoretical model is introduced which indicates that the pore formation process is limited by the diffusion of solute-gas through the melt, and that the observed response toa pressure increase is attributed to the re-equilibration of solute concentration in the melt associated with the increased melt pressure.

Grugel, R.N.↗

A high voltage pulsed power supply for capillary discharge waveguide applications

We present an all solid-state, high voltage pulsed power supply for inducing stable plasma formation (density {approx}10{sup 18} cm{sup -3}) in gas-filled capillary discharge waveguides. The pulser (pulse duration of 1 {mu}s) is based on transistor switching and wound transmission line transformer technology. For a capillary of length 40 mm and diameter 265 {mu}m and gas backing pressure of 100 mbar, a fast voltage pulse risetime of 95 ns initiates breakdown at 13 kV along the capillary. A peak current of {approx}280 A indicates near complete ionization, and the r.m.s. temporal jitter in the current pulse is only 4 ns. Temporally stable plasma formation is crucial for deploying capillary waveguides as plasma channels in laser-plasma interaction experiments, such as the laser wakefield accelerator.

43 PARTICLE ACCELERATORS↗

Micro-PIV measurements of multiphase flow of water and liquid CO 2 in 2-D heterogeneous porous micromodels

We present an experimental study of pore-scale flow dynamics of liquid CO 2 and water in a two-dimensional heterogeneous porous micromodel, inspired by the structure of a reservoir rock, at reservoir-relevant conditions (80 bar, 21°C). The entire process of CO 2 infiltration into a water-saturated micromodel was captured using fluorescence microscopy and the micro-PIV method, which together reveal complex fluid displacement patterns and abrupt changes in velocity. The CO 2 front migrated through the resident water in an intermittent manner, forming dendritic structures, termed fingers, in directions along, normal to, and even opposing the bulk pressure gradient. Such characteristics indicate the dominance of capillary fingering through the micromodel. Velocity burst events, termed Haines jumps, were also captured in the heterogeneous micromodel, during which the local Reynolds number was estimated to be ~21 in the CO 2 phase, exceeding the range of validity of Darcy's law. Furthermore, these drainage events were observed to be cooperative (i.e., across multiple pores simultaneously), with the zone of influence of such events extending beyond tens of pores, confirming, in a quantitative manner, that Haines jumps are nonlocal phenomena. After CO 2 completely breaks through the porous section, shear-induced circulations caused by flowing CO 2 were also observed, in agreement with previous studies using a homogeneous porous micromodel. To our knowledge, this study is the first quantitative measurement that incorporates both reservoir-relevant conditions and rock-inspired heterogeneity, and thus will be useful for pore-scale model development and validation.

42 ENGINEERING↗

Oxygen distribution in tumors: A qualitative analysis and modeling study providing a novel Monte Carlo approach

Purpose: To construct a Monte Carlo (MC)-based simulation model for analyzing the dependence of tumor oxygen distribution on different variables related to tumor vasculature [blood velocity, vessel-to-vessel proximity (vessel proximity), and inflowing oxygen partial pressure (pO{sub 2})]. Methods: A voxel-based tissue model containing parallel capillaries with square cross-sections (sides of 10 μm) was constructed. Green's function was used for diffusion calculations and Michaelis-Menten's kinetics to manage oxygen consumption. The model was tuned to approximately reproduce the oxygenational status of a renal carcinoma; the depth oxygenation curves (DOC) were fitted with an analytical expression to facilitate rapid MC simulations of tumor oxygen distribution. DOCs were simulated with three variables at three settings each (blood velocity, vessel proximity, and inflowing pO{sub 2}), which resulted in 27 combinations of conditions. To create a model that simulated variable oxygen distributions, the oxygen tension at a specific point was randomly sampled with trilinear interpolation in the dataset from the first simulation. Six correlations between blood velocity, vessel proximity, and inflowing pO{sub 2} were hypothesized. Variable models with correlated parameters were compared to each other and to a nonvariable, DOC-based model to evaluate the differences in simulated oxygen distributions and tumor radiosensitivities for different tumor sizes. Results: For tumors with radii ranging from 5 to 30 mm, the nonvariable DOC model tended to generate normal or log-normal oxygen distributions, with a cut-off at zero. The pO{sub 2} distributions simulated with the six-variable DOC models were quite different from the distributions generated with the nonvariable DOC model; in the former case the variable models simulated oxygen distributions that were more similar to in vivo results found in the literature. For larger tumors, the oxygen distributions became truncated in the lower end, due to anoxia, but smaller tumors showed undisturbed oxygen distributions. The six different models with correlated parameters generated three classes of oxygen distributions. The first was a hypothetical, negative covariance between vessel proximity and pO{sub 2} (VPO-C scenario); the second was a hypothetical positive covariance between vessel proximity and pO{sub 2} (VPO+C scenario); and the third was the hypothesis of no correlation between vessel proximity and pO{sub 2} (UP scenario). The VPO-C scenario produced a distinctly different oxygen distribution than the two other scenarios. The shape of the VPO-C scenario was similar to that of the nonvariable DOC model, and the larger the tumor, the greater the similarity between the two models. For all simulations, the mean oxygen tension decreased and the hypoxic fraction increased with tumor size. The absorbed dose required for definitive tumor control was highest for the VPO+C scenario, followed by the UP and VPO-C scenarios. Conclusions: A novel MC algorithm was presented which simulated oxygen distributions and radiation response for various biological parameter values. The analysis showed that the VPO-C scenario generated a clearly different oxygen distribution from the VPO+C scenario; the former exhibited a lower hypoxic fraction and higher radiosensitivity. In future studies, this modeling approach might be valuable for qualitative analyses of factors that affect oxygen distribution as well as analyses of specific experimental and clinical situations.

60 APPLIED LIFE SCIENCES↗

Increased technetium uptake is not equivalent to muscle necrosis: scintigraphic, morphological and intramuscular pressure analyses of sore muscles after exercise

A scintigraphic technique employing technetium pyrophosphate uptake was used to identify the area of skeletal muscle damage in the lower leg of four runners 24 h after an ultramarathon footrace (160 km). Most of the race had been run downhill which incorporated an extensive amount of eccentric work. Soreness was diffuse throughout the posterior region of the lower leg. In order to interpret what increased technetium uptake reflects and to express extreme endurance related damages, a biopsy was taken from the 3-D position of abnormal uptake. In addition, intramuscular pressures were determined in the deep posterior compartment. Scintigraphs revealed increased technetium pyrophosphate uptake in the medial portion of the gastrocnemius muscle. For 3698 fibres analysed, 33 fibres (1%) were necrotic, while a few other fibres were either atrophic or irregular shaped. A cluster of necrotic fibres occurred at the fascicular periphery for one subject and fibre type grouping occurred for another. Ultrastructural analysis revealed Z-line streaming near many capillaries and variously altered subsarcolemmal mitochondria including some with paracrystalline inclusions. The majority of the capillaries included thickened and irregular shaped endothelial cells. Intramuscular pressures of the deep posterior compartment were slightly elevated (12-15 mmHg) for three of the four subjects. Increased technetium uptake following extreme endurance running does not just reflect muscle necrosis but also subtle fibre abnormalities. Collectively, these pathological findings are attributed to relative ischaemia occurring during the race and during pre-race training, whereas, intramuscular pressure elevations associated with muscle soreness are attributed to mechanical stress caused by extensive eccentric work during the race.

NASA Program Space Physiology and Countermeasures↗

Combining selection valve and mixing chamber for nanoflow gradient generation: Toward developing a liquid chromatography cartridge coupled with mass spectrometer for protein and peptide analysis

In relation to developing a micro HPLC cartridge, we have recently built a high-pressure electroosmotic pump (EOP). However, we do not recommend people to use this pump to deliver an organic solvent directly, because it often makes the pump rate unstable. We have experimented several approaches to address this issue, but none of them are satisfactory. Here, we develop an innovative approach to address this issue. We first create an abruption (a dead-volume) within a fluid conduit. We then utilize an EOP to withdraw, via a selection valve, a train of eluent solutions having decreasing eluting power into the fluid conduit. When these solutions are further aspirated through the dead-volume, these solutions are partially mixed, smoothening concentration transitions between two adjacent eluent solutions. As these solutions are pushed back, through the dead-volume again, a smooth gradient profile is formed. In this work, we characterize this scheme for gradient formation, and we incorporate this approach with a high-pressure EOP, a nanoliter injection valve, and a capillary column, yielding a micro HPLC system. Lastly, we then couple this micro HPLC with an electrospray ionization – mass spectrometer for peptide and protein separations and identifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗