Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cabin”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Evaluating Sensory Augmentation as A Non-Pharmaceutical Tool to Mitigate Motion Sickness and Enhance Sensorimotor Task Performance: A Pilot Study Using Simulated Capsule Wave Motion

Wave motion during capsule recovery operations can result in motion sickness and performance decrements exacerbating reentry sickness following long duration spaceflight. The purpose of this pilot study was (1) to validate a capsule wave motion simulation as a platform to evaluate motion sickness countermeasures and (2) to evaluate a sensory augmentation belt providing vibrotactile feedback of gravitational upright. Ten healthy subjects ages 38.0 ± 10.1 (6M|4F) were exposed to complex wave motions on a six degree-of-freedom platform that included pitch, roll, and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Subjects reported acute symptoms for up to three consecutive 15 min trials or until they reached a motion sickness endpoint of 8 pts on the Pensacola Diagnostic Index (PDI). Five subjects were randomly assigned to the Sensory Augmentation (SA) group while the other five served as controls (CN group). Based on a Motion Sickness Susceptibility Questionnaire, the two groups had similar motion sickness histories (susceptibility percentile ranking of CN group = 27.5 ± 63.6 in the CN group versus 27.5 ± 37.0 in the SA group, median ± IQR). The vibrotactile feedback consisted of a single array of 8 electromechanical tactors positioned around the torso on an adjustable belt (Engineering Acoustics, Inc) that utilized an integrated inertial measurement unit (IMU) to indicate the direction of upright (e.g., subject’s back tactor on during forward tilt). During each wave motion trial subjects performed a battery of four different tasks: tracking Earth vertical using a joystick with and without a secondary task (Paced Auditory Serial Addition Test), an eye-hand target acquisition task on a cabin-fixed tablet, and the psychomotor vigilance test (PVT). All ten subjects reported varying levels of motion sickness with 6 of 10 reaching a symptom endpoint. Interestingly, subjects anecdotally reported that engagement in the joystick tracking task was less provocative than tasks involving the cabin-fixed tablet or periods of no activity. Sensory augmentation appeared to delay symptom onset, with 2 of 5 subjects reaching an endpoint within the first 15 min trial in the CN group versus none in the SA group (PDI after 15 min = 6.0 ± 2.5 in the CN group versus 3.4 ± 2.5 in the SA group, mean ±std). Sensory augmentation also improved performance on the joystick tracking task at lower stimulus frequencies (0.1 Hz in roll and 0.2 Hz in pitch). Both CN and SA groups maintained a consistent level of performance on the eye-hand target acquisition and PVT throughout the baseline (no motion) and wave motion periods. Our results validated that the simulated capsule wave motion paradigm provides an effective motion sickness stressor. This paradigm is currently being used to investigate the efficacy of intranasal scopolamine to mitigate motion sickness. Sensory augmentation using vibrotactile feedback appears to improve spatial awareness and delay symptom onset during complex passive motion. One advantage of this portable belt design is that it incorporates all tactor drive and IMU circuitry and therefore could continue to be worn by crewmembers and serve as a balance aid during egress and ambulation with recovery operations.

A M Bollinger↗

Simulation and Analysis of NASA Lift Plus Cruise eVTOL Crash Test

The National Aeronautics and Space Administration (NASA) will perform a full-scale crash test of a representative electric vertical take-off and landing (eVTOL) fuselage in November 2022. The test article is a carbon-composite fuselage cabin section of the six-passenger lift plus cruise (LPC) eVTOL design concept which was created by NASA to advance understanding of eVTOL propulsion, noise, and safety. The test will consist of impacting the fuselage cabin section onto a concrete surface with a combined horizontal and vertical velocity approximating a severe but survivable crash landing for this vehicle design. Data generated from this test will be used to inform eVTOL crashworthiness regulation development, evaluate the use of energy absorbing concepts within vehicle design, and validate finite element model (FEM) techniques used in crashworthiness predictions. The cabin section response will be evaluated using structural instrumentation, anthropometric test devices (ATDs), and high-speed photogrammetry. This study will compare pre-test FEM predictions to test results to quantify the capability of these tools to predict crashworthiness of the carbon-composite eVTOL airframe.

Crashworthiness↗

Simulation and Analysis of NASA Lift Plus Cruise eVTOL Crash Test

The National Aeronautics and Space Administration (NASA) will perform a full-scale crash test of a representative electric vertical take-off and landing (eVTOL) fuselage in November 2022. The test article is a carbon-composite fuselage cabin section of the six-passenger lift plus cruise (LPC) eVTOL design concept which was created by NASA to advance understanding of eVTOL propulsion, noise, and safety. The test will consist of impacting the fuselage cabin section onto a concrete surface with a combined horizontal and vertical velocity approximating a severe but survivable crash landing for this vehicle design. Data generated from this test will be used to inform eVTOL crashworthiness regulation development, evaluate the use of energy absorbing concepts within vehicle design, and validate finite element model (FEM) techniques used in crashworthiness predictions. The cabin section response will be evaluated using structural instrumentation, anthropometric test devices (ATDs), and high-speed photogrammetry. This study will compare pre-test FEM predictions to test results to quantify the capability of these tools to predict crashworthiness of the carbon-composite eVTOL airframe.

Crashworthiness↗

Source Contaminant Control System Design, Operation, and Testing for the Trash Compaction and Processing System

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). This process involves heating the trash to high temperatures, which in turn releases gaseous contaminants. Effluent management scenarios involve releasing these gases back to the ISS cabin after processing and/or directly venting these gases out to space via the Vacuum Exhaust System (VES). Concerns for recovering the gases back to cabin are crew health, safety, and spacecraft environmental impact. The Heat Melt Compactor (HMC) at NASA Ames Research Center (ARC) serves as a test system that supports TCPS development by conducting risk reduction activities associated with an ISS flight demonstration. Previous gas effluent studies were conducted on the HMC. The results consisted of contaminants from the trash exhaust to exceed Spacecraft Maximum Allowable Concentrations (SMAC), which are selected airborne contaminants that can elicit toxicity symptoms to crewmembers via exposure. The Source Contaminant Control System (SCCS) aims to reduce that risk by converting the contaminants into carbon dioxide (CO2) and water (H2O) vapor. The SCCS is composed of a carbon adsorbent bed, to avoid catalyst poisoning, and a catalytic oxidizer (CatOx), which promotes oxidation of the contaminants to CO2and H2O. In turn, the gases coming out of the SCCS should be compatible to the ISS cabin and systems such as the Trace Contaminant Control System (TCCS). Preparation for SCCS testing alongside the HMC Gen 3 are currently underway at ARC. The main objectives are to evaluate CatOx efficiency by CO2conversion and characterize effectiveness of removal by comparing contaminant results before and after CatOx. This paper will report on the SCCS design, operation, and testing with results.

TCPS↗

Nasa Exploration Atmosphere Tests 3 & 4: Development and Validation of Planetary Extravehicular Activity Prebreathe Protocols for Alternate Atmospheres and Suit Pressures

INTRODUCTION: Space suits operate at low pressures to optimize astronauts’ performance. The drop in pressure from the habitat environment to the suit carries a risk of decompression sickness (DCS), which is mitigated by a 95% O2 prebreathe protocol. Prebreathe protocols for the lunar surface have a significantly higher risk compared to International Space Station microgravity Extravehicular Activities (EVA). In previous studies, we validated a prebreathe protocol from a 56.5 kPa 34% O2 cabin to a 29.6 kPa EVA pressure; however, the enriched oxygen cabin environment poses a flammability risk that requires significant changes to material design and selections. Here, we report outcomes for prebreathe protocols from a sub-30% O2 cabin and associated changes necessary to control DCS risk critical to upcoming lunar missions. METHODS: Fourteen volunteers completed 11-day hypobaric chamber studies with an “alternate exploration atmosphere” of 66.2kPa, 28.5% O2. Subjects acclimated for 48 hrs and then participated in five 6-hour simulated EVAs at 29.6 or 35.6kPa, 95% O2. Prior to EVA, subjects underwent a 20, 90, or 150-minute prebreathe. The EVA simulation was designed to be representative of future planetary EVAs, proportionate to the subject’s VO2max. Decompression stress was monitored by real-time doppler and echocardiograph alternating every 15 min, as well as clinical monitoring for DCS signs/symptoms. Venous gas emboli (VGE) and DCS outcomes were verified against NASA-STD-3001 acceptance criteria. RESULTS AND DISCUSSION: Venous gas emboli (VGE) were identified during all EVAs. A neurological DCS case was identified in the 90-min/29.6kPa prebreathe, terminating further testing of this protocol. No DCS cases were identified in the 150 min/29.6kPa protocol. The 20 min/36.5kPa protocol was rejected due to a Type II DCS case. All DCS symptoms resolved with treatment, with no sequelae post initial treatment of DCS. These various test points highlighted to the significant benefit of elevated suit pressure to shorten prebreathe protocols, but also the difficulty in assessing and managing DCS during sustained EVA operations in remote planetary surfaces.

decompression sickness↗

Analysis of Off-Board Powered Thermal Preconditioning in Electric Drive Vehicles: Preprint

Following a hot or cold thermal soak, vehicle climate control systems (air conditioning or heat) are required to quickly attain a cabin temperature comfortable to the vehicle occupants. In a plug-in hybrid electric or electric vehicle (PEV) equipped with electric climate control systems, the traction battery is the sole on-board power source. Depleting the battery for immediate climate controlresults in reduced charge-depleting (CD) range and additional battery wear. PEV cabin and battery thermal preconditioning using off-board power supplied by the grid or a building can mitigate the impacts of climate control. This analysis shows that climate control loads can reduce CD range up to 35%. However, cabin thermal preconditioning can increase CD range up to 19% when compared to nothermal preconditioning. In addition, this analysis shows that while battery capacity loss over time is driven by ambient temperature rather than climate control loads, concurrent battery thermal preconditioning can reduce capacity loss up to 7% by reducing pack temperature in a high ambient temperature scenario.

25 ENERGY STORAGE↗

UTEMPRA - Unitary Thermal Energy Management for Propulsion Range Augmentation

Key hurdles to achieving wide consumer acceptance of battery electric vehicles (BEVs) are weather-dependent drive range, higher cost, and limited battery life. These translate into a strong need to reduce a significant energy drain and resulting drive range loss due to auxiliary electrical loads the predominant of which is the cabin thermal management load. Studies have shown that thermal subsystem loads can reduce the drive range by as much as 45% under ambient temperatures below -10 degrees C. Often, cabin heating relies purely on positive temperature coefficient (PTC) resistive heating, contributing to a significant range loss. Reducing this range loss may improve consumer acceptance of BEVs. The authors present a unified thermal management system (UTEMPRA) that satisfies diverse thermal and design needs of the auxiliary loads in BEVs. Demonstrated on a 2015 Fiat 500e BEV, this system integrates a semi-hermetic refrigeration loop with a coolant network and serves three functions: (1) heating and/or cooling vehicle traction components (battery, power electronics, and motor), (2) heating and cooling of the cabin, and (3) waste energy harvesting and re-use. The modes of operation allow a heat pump and air conditioning system to function without reversing the refrigeration cycle to improve thermal efficiency. The refrigeration loop consists of an electric compressor, a thermal expansion valve, a coolant-cooled condenser, and a chiller, the latter two exchanging heat with hot and cold coolant streams that may be directed to various components of the thermal system. The coolant-based heat distribution is adaptable and saves significant amounts of refrigerant per vehicle. Also, a coolant-based system reduces refrigerant emissions by requiring fewer refrigerant pipe joints. The authors present bench-level test data and simulation analysis and describe a preliminary control scheme for this system.

33 ADVANCED PROPULSION SYSTEMS↗

Climate Control Load Reduction Strategies for Electric Drive Vehicles in Warm Weather

Passenger compartment climate control is one of the largest auxiliary loads on a vehicle. Like conventional vehicles, electric vehicles (EVs) require climate control to maintain occupant comfort and safety, but cabin heating and air conditioning have a negative impact on driving range for all electric vehicles. Range reduction caused by climate control and other factors is a barrier to widespread adoption of EVs. Reducing the thermal loads on the climate control system will extend driving range, thereby reducing consumer range anxiety and increasing the market penetration of EVs. Researchers at the National Renewable Energy Laboratory have investigated strategies for vehicle climate control load reduction, with special attention toward EVs. Outdoor vehicle thermal testing was conducted on two 2012 Ford Focus Electric vehicles to evaluate thermal management strategies for warm weather, including solar load reduction and cabin pre-ventilation. An advanced thermal test manikin was used to assess a zonal approach to climate control. In addition, vehicle thermal analysis was used to support testing by exploring thermal load reduction strategies, evaluating occupant thermal comfort, and calculating EV range impacts. Through stationary cooling tests and vehicle simulations, a zonal cooling configuration demonstrated range improvement of 6%-15%, depending on the drive cycle. A combined cooling configuration that incorporated thermal load reduction and zonal cooling strategies showed up to 33% improvement in EV range.

33 ADVANCED PROPULSION SYSTEMS↗

Bench Testing Results for the Electrical PCM-Assisted Thermal Heating System (ePATHS)

Bench testing of the Electrical PCM-Assisted Thermal Heating System (ePATHS) was completed at the Building Technologies Research and Integration Center (BTRIC) at the Oak Ridge National Laboratory (ORNL). The ePATHS is a thermal energy storage device designed to reduce the energy required from the battery for cabin heating of electric vehicles (EVs) and plug-in hybrid electric vehicles (PHEVs). ORNL s testing of the ePATHS assessed three main aspects of operation of the device: 1.ePATHS charging evaluation: measure the time to charge and the energy input needed to fully charge the PCM for a range of different ambient conditions. 2.ePATHS Discharge Evaluations: measure the energy provided by the PCM HX, both during mode 1 and mode 2 operation, and confirm the cabin heating duration that can be provided by the ePATHS. This is the primary evaluation to validate the system performance, and an array of multiple ambient conditions and operating scenarios were tested. 3.Evaluation of Thermal Losses from the ePATHS during Cold Soak: this test will evaluate the performance of the insulation system for the ePATHS. The charged ePATHS undergoes a long-term soak in cold ambient temperature conditions, and the heat losses will be evaluated to validate that the performance meets the maximum energy loss requirement.

33 ADVANCED PROPULSION SYSTEMS↗

Superhydrophobic heat exchangers delay frost formation and enhance efficency of electric vehicle heat pumps

The number of electric vehicles has rapidly expanded as high-performance automotive lithium-ion batteries have become more affordable. However, the range of electric vehicles decreases in cold climates partly because of the additional thermal loads associated with cabin heating. One way to improve the efficiency of cabin heating is to replace resistive heating elements with an air-source heat pump system. However, to gain the full benefit of heat pumping, frost formation on the outdoor heat exchanger must be minimized. In this work, we modified the surface wettability of aluminum louvered-fin automotive heat pump evaporators and tested them under realistic operating conditions in a transcritical carbon dioxide (CO 2 ) heat pump. Each heat exchanger underwent several consecutive frosting and defrosting cycles to understand the cyclic performance of the system. The heat exchanger with a superhydrophobic outer surface was able to delay frost formation and maintain higher heat transfer rates when compared to heat exchangers with higher surface energies (hydrophilic). The delayed frost formation resulted in a system efficiency benefit in the first few frosting cycles but diminished in later cycles due to water retention and incomplete defrosting. However, for most automotive applications the superhydrophobic heat exchanger showed substantial benefits for normal driving trips. We report the scalable and optimized superhydrophobic heat exchangers developed here have the potential to increase the efficiency of automotive heat pumps and consequently increase the range and reduce energy consumption of electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shock compression of additively manufactured high solids loaded polymer composites with aligned porosity

The effects of aligned porosity on the shock-compression response of additively manufactured (AM) composite structures with collinear and log-cabin geometries are investigated. The composites contain two inorganic and two organic particle populations and a UV-curable polymer binder. X-ray phase contrast imaging (X-PCI) is used as an in-material diagnostic in plate-impact experiments performed at the Dynamic Compression Sector of the Advanced Photon Source at the Argonne National Laboratory. Macroscale shock and particle velocities and microscale pore collapse velocities are measured from X-PCI images obtained from samples impacted in various orientations relative to the AM build directions. The linear shock and particle velocity relation for the structures with collinear build geometry shows directional differences, with the build direction exhibiting the highest slope and the filament print direction having the shallowest slope. Composites with log-cabin geometry, due to their slightly lower porosity and smaller sized pores, show higher shock velocities than the collinear structures at the same particle velocity. Microscale directionality effects are also observed, with the pore collapse velocity dependent on the pore configuration. Specifically, the pore collapse velocity is highest for pores elongated along the impact direction which is the case for the colinear structures impacted in the filament print direction, which is consistent with the directionality trend observed in the data for the shock and particle velocity equation of state. The pore collapse velocity approaches ∼80 % of the shock velocity and is several times the average bulk particle velocity, suggesting a highly hydrodynamic mechanism of pore collapse. Overall, both the macroscale response as measured by the shock and particle velocity relationship, and the microscale response as measured by the pore collapse velocity, are found to be anisotropic and dependent on the AM composite structure.

Wagner, K. B. [Georgia Institute of Technology, At↗

Exposure to tri-o-cresyl phosphate detected in jet airplane passengers

The aircraft cabin and flight deck ventilation are supplied from partially compressed unfiltered bleed air directly from the engine. Worn or defective engine seals can result in the release of engine oil into the cabin air supply. Aircrew and passengers have complained of illness following such 'fume events'. Adverse health effects are hypothesized to result from exposure to tricresyl phosphate mixed esters, a chemical added to jet engine oil and hydraulic fluid for its anti-wear properties. Our goal was to develop a laboratory test for exposure to tricresyl phosphate. The assay was based on the fact that the active-site serine of butyrylcholinesterase reacts with the active metabolite of tri-o-cresyl phosphate, cresyl saligenin phosphate, to make a stable phosphorylated adduct with an added mass of 80 Da. No other organophosphorus agent makes this adduct in vivo on butyrylcholinesterase. Blood samples from jet airplane passengers were obtained 24-48 h after completing a flight. Butyrylcholinesterase was partially purified from 25 ml serum or plasma, digested with pepsin, enriched for phosphorylated peptides by binding to titanium oxide, and analyzed by mass spectrometry. Of 12 jet airplane passengers tested, 6 were positive for exposure to tri-o-cresyl phosphate that is, they had detectable amounts of the phosphorylated peptide FGEpSAGAAS. The level of exposure was very low. No more than 0.05 to 3% of plasma butyrylcholinesterase was modified. None of the subjects had toxic symptoms. Four of the positive subjects were retested 3 to 7 months following their last airplane trip and were found to be negative for phosphorylated butyrylcholinesterase. In conclusion, this is the first report of an assay that detects exposure to tri-o-cresyl phosphate in jet airplane travelers. -- Highlights: Black-Right-Pointing-Pointer Travel on jet airplanes is associated with an illness, aerotoxic syndrome. Black-Right-Pointing-Pointer A possible cause is exposure to tricresyl phosphate in engine lubricating oil. Black-Right-Pointing-Pointer A blood test for exposure to tri-o-cresyl phosphate is reported.

60 APPLIED LIFE SCIENCES↗

Reflection modeling in ultraviolet phototherapy

Purpose: Ultraviolet phototherapy is a widely used treatment which has exceptional success with a variety of skin conditions. Over-exposure to ultraviolet radiation (UVR) can however be detrimental and cause side effects such as erythema, photokeratisis, and even skin cancer. Quantifying patient dose is therefore imperative to ensure biologically effective treatment while minimizing negative repercussions. A dose model for treatment would be valuable in achieving these ends. Methods: Prior work by the authors concentrated on modeling the output of the lamps used in treatment and it was found a line source model described the output from the sources to a high degree. In practice, these lamps are surrounded by reflective anodized aluminum in patient treatment cabins and this work extends the model to quantify specular reflections from these planes on patient dose. Results: The extension of the model to allow for reflected images in addition to tube output shows a remarkably good fit to the actual data measured. Conclusions: The reflection model yields impressive accuracy and is a good basis for full UVR cabin modeling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Immersive Particle Advection: Through the Scales of Renewable Energy: Preprint

We describe the benefits of immersive flow analysis for three large-scale computational science studies in the field of renewable energy. The studies encompass a range of scales, spanning from the large atmospheric scale of a wind farm to the human scale of an electric vehicle cabin down to the microscopic scale of battery material science. In these studies, users explored the flow patterns and dynamics through immersive particle advection. The integration of high-performance computing with immersive analysis provided a deeper understanding of these systems, helping develop more effective solutions for a sustainable energy future.

computational fluid dynamics↗

Electric Vehicle Supply Equipment (EVSE) Site Assessment Report for the U.S. Army Corps of Engineers Chena Site Near Fairbanks, Alaska

This report presents an analysis of the requirements for charging station installation and electric vehicle operation at the US Army Corps of Engineers - Chena Site, located in a cold weather climate in the Fairbanks North Star Borough, AK. The report includes findings from a site visit, and a detailed electric vehicle (EV) charging site plan with cost estimates. Cost for three 50-ampere pedestal chargers located on the edge of the existing parking lot is estimated at $\$$53,100, and the cost of three 80-ampere chargers is estimated at $\$$89,400. The authors did not assess the cost of a heated garage. The USACE Chena site reaches extreme cold temperatures of -40 Degrees Celsius (-40 Degrees Fahrenheit) and below in a typical winter, often for days on end. Considerations of operating EVs as well as electrical vehicle supply equipment (EVSE) at this site can be applicable to other cold or extremely cold locations. Interviews with EV users in cold climates and a literature review indicated that EVs operate well but have significantly decreased range compared to 21 Degrees Celsius (70 Degrees Fahrenheit) operations. Some strategies such as prewarming the vehicle while it is plugged in and using heated seats and steering wheel instead of cabin heat, can improve cold weather performance. Storing the EV in a garage would mean the battery and cabin are automatically preheated, the battery would not age as rapidly as when the vehicle is stored outside, and problems with charging the vehicle are less likely. Lowest temperate-rated Electric Vehicle Supply Equipment (EVSE), as electric vehicle chargers are known as, are rated to -40 Degrees Celsius (-40 Degrees Fahrenheit), and sometimes malfunction. No EVSE is rated to the temperatures that USACE Chena site experienced for more than a week in winter 2023-4, of -50 Degrees Celsius (-45 Degrees Fahrenheit) and which are typical for the area. If reliability is a must, entities may want to consider a heated garage to minimize potential problems with charging equipment. There is a companion technical report to this titled "Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska" that examines the data on EV and EVSE cold-weather functionality in more detail. (Esparza, Truffer Moudra, and Hodge 2024).

33 ADVANCED PROPULSION SYSTEMS↗

Pilgrim Hot Springs Building Dimensions and Energy Modeling

This dataset was created to model the anticipated heating load of a geothermal project in development for the historical site of Pilgrim Hot Springs, and adds to the history of geothermal studies at the site. Models include an historical building (Nun's Quarters), existing modern buildings (Caretaker's Cabin, Igloo, Visitor's Cabin, Staff Shower Hut), and planned building projects (Changing Room, Greenhouse). Modeling results were used to determine feasible geothermal system typologies. The previous study linked below ("Village of Solomon Development of Energy Efficiency Building Standards for New Construction") feeds in to this project. The dataset includes DWG drawings and AKwarm energy models (.hm2) of a subset of existing buildings at the site of Pilgrim Hot Springs. All buildings were modeled in their current state, and some were additionally modeled with improvements to the building envelope. Energy modeling results exported from AKwarm include .htm and .png images.

AKwarm↗

In-Cab Air Quality of Trucks Air Conditioned and Kept in Electrified Truck Stop

At night, long-haul truck drivers rest inside the cabins of their vehicles. Therefore, the in-cab air quality while air conditioning (A/C) is being provided can be a great concern to the drivers health. The effect of using different A/C methods [truck's A/C, auxiliary power unit (APU), and truck stop electrification (TSE) unit] on in-cab air quality of a heavy-duty diesel vehicle was investigated at an electrified truck stop in the El Paso, Texas, area. The research team measured the in-cabin and the ambient air quality adjacent to the parked diesel truck as well as emissions from the truck and an APU while it was providing A/C. The measured results were compared and analyzed. On the basis of these results, it was concluded that the TSE unit provided better in-cab air quality while supplying A/C. Furthermore, the truck and APU exhaust emissions were measured, and fuel consumption of the truck (while idling) and the APU (during operation) were compared. The results led to the finding that emissions from the APU were less than those from the truck's engine idling, but the APU consumed more fuel than the engine while providing A/C under given conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Climate Control Load Reduction Strategies for Electric Drive Vehicles in Cold Weather

When operated, the climate control system is the largest auxiliary load on a vehicle. This load has significant impact on fuel economy for conventional and hybrid vehicles, and it drastically reduces the driving range of all electric vehicles (EVs). Heating is even more detrimental to EV range than cooling because no engine waste heat is available. Reducing the thermal loads on the heating, ventilating, and air conditioning system will extend driving range and increase the market penetration of EVs. Researchers at the National Renewable Energy Laboratory have evaluated strategies for vehicle climate control load reduction with special attention toward grid connected electric vehicles. Outdoor vehicle thermal testing and computational modeling were used to assess potential strategies for improved thermal management and to evaluate the effectiveness of thermal load reduction technologies. A human physiology model was also used to evaluate the impact on occupant thermal comfort. Experimental evaluations of zonal heating strategies demonstrated a 5.5% to 28.5% reduction in cabin heating energy over a 20-minute warm-up. Vehicle simulations over various drive cycles show a 6.9% to 18.7% improvement in EV range over baseline heating using the most promising zonal heating strategy investigated. A national-level analysis was conducted to determine the overall national impact. If all vehicles used the best zonal strategy, the range would be improved by 7.1% over the baseline heating range. This is a 33% reduction in the range penalty for heating.

30 DIRECT ENERGY CONVERSION↗