Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTAINER SAMPLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

SDSS-IV MaNGA: How Galaxy Interactions Influence Active Galactic Nuclei

We present a comparative study of active galactic nuclei (AGN) between galaxy pairs and isolated galaxies with the final data release of the MaNGA integral field spectroscopic survey. We build a sample of 391 kinematic galaxy pairs within the footprint of the survey and select AGN using the survey's spectra. We use the comoving volume densities of the AGN samples to quantify the effects that tidal interactions have on the triggering of nuclear accretion. Our hypothesis is that the pair sample contains AGN that are triggered by not only stochastic accretion but also tidally induced accretion and correlated accretion. With the level of stochastically triggered AGN fixed by the control sample, we model the strength of tidally induced accretion and correlated accretion as a function of projected separation (r p ) and compare the model expectations with the observed volume densities of dual AGN and offset AGN (single AGN in a pair). At r p ~ 10 kpc, we find that tidal interactions induce ~30% more AGN than stochastic fueling and cause ~12% of the offset AGN to become dual AGN because of correlations. The strength of both these effects decreases with increasing r p . We also find that the [O III ] luminosities of the AGN in galaxy pairs are consistent with those found in isolated galaxies, likely because stochastically fed AGN dominate even among close pairs. Our results illustrate that while we can detect tidally induced effects statistically, it is challenging to separate tidally induced AGN and stochastically triggered AGN in interacting galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Einstein X-ray observations of QSO's with absorption-line systems

The detection of X-ray emission from eight QSO's is reported, plus an upper limit to the X-ray flux from one QSO, using the Einstein X-ray Observatory (HEAO-2). Each object in the sample contains at least one absorption-line system that has been identified in its optical spectrum. The present results are combined with those of other investigators to form a sample of 44 absorption-line QSO's (with 2 sub e greater than 1.2) which have been observed in the X-ray. This sample cannot be distinguished, in terms of X-ray properties, from one which consists of QSO's in which no absorption systems have been identified. These results are consistent with extrinsic models for absorption-line clouds, as well as with current versions of intrinsic models.

Junkkarinen, V. T.↗

X-ray attenuation properties of stainless steel (u)

Stainless steel vessels are used to enclose solid materials for studying x-ray radiolysis that involves gas release from the materials. Commercially available stainless steel components are easily adapted to form a static or a dynamic condition to monitor the gas evolved from the solid materials during and after the x-ray irradiation. Experimental data published on the x-ray attenuation properties of stainless steel, however, are very scarce, especially over a wide range of x-ray energies. The objective of this work was to obtain experimental data that will be used to determine how a poly-energetic x-ray beam is attenuated by the stainless steel container wall. The data will also be used in conjunction with MCNP (Monte Carlos Nuclear Particle) modeling to develop an accurate method for determining energy absorbed in known solid samples contained in stainless steel vessels. In this study, experiments to measure the attenuation properties of stainless steel were performed for a range of bremsstrahlung x-ray beams with a maximum energy ranging from 150 keV to 10 MeV. Bremsstrahlung x-ray beams of these energies are commonly used in radiography of engineering and weapon components. The weapon surveillance community has a great interest in understanding how the x-rays in radiography affect short-term and long-term properties of weapon materials.

36 MATERIALS SCIENCE↗

Practical Guide to Chemometric Analysis of Optical Spectroscopic Data

The methodology and mathematical treatment of several classic multivariate methods for the analysis of spectroscopic data is demonstrated in a straightforward way that can be used as a basis for teaching an undergraduate introductory course on chemometric analysis. The multivariate techniques of classical least squares (CLS), principal component regression (PCR), and partial least squares (PLS), as well as the univariate Beer’s law method have been described and compared, building students’ understanding by starting with the univariate method and progressing step by step into the multivariate methods. Equations for the production of regression vectors from training set spectral data is described and their use demonstrated for the prediction of constituent concentrations on a separate validation set of spectra. Extreme care is taken to ensure consistency in variable formatting of data matrices. This provides a key foundation to understanding how spectral data are manipulated using these different mathematical approaches for building quantitative regression models. Each method is applied to a real-world data set, and the results are discussed to show students the types of information that can be gleaned from each method. A training set comprised of 20 infrared absorbance spectra containing 3 constituents (benzene, polystyrene, and gasoline) of known composition are used to demonstrate the matrix operations for each regression method. A separate set of 12 real-world napalm samples (containing benzene, polystyrene and gasoline) are used as a validation set to demonstrate the ability to utilize the regression models on an unknown dataset. A toolbox (PNNL Chemometric Toolbox) written in MATLAB language is supplied in the Supplemental Information file and can be used as a companion for understanding the development and deployment of the chemometric algorithms described in this paper. The datasets of the infrared spectra are also supplied, allowing users to build and inspect the chemometric models on their own. Finally, the Toolbox includes scripts to assist users in loading their own datasets into MATLAB and performing CLS, PCR, and PLS on their data.

Upper-Division Undergraduate, Analytical Chemistry↗

TRACING THE MAGNETIC FIELD MORPHOLOGY OF THE LUPUS I MOLECULAR CLOUD

Deep R-band CCD linear polarimetry collected for fields with lines of sight toward the Lupus I molecular cloud is used to investigate the properties of the magnetic field within this molecular cloud. The observed sample contains about 7000 stars, almost 2000 of them with a polarization signal-to-noise ratio larger than 5. These data cover almost the entire main molecular cloud and also sample two diffuse infrared patches in the neighborhood of Lupus I. The large-scale pattern of the plane-of-sky projection of the magnetic field is perpendicular to the main axis of Lupus I, but parallel to the two diffuse infrared patches. A detailed analysis of our polarization data combined with the Herschel/SPIRE 350 μm dust emission map shows that the principal filament of Lupus I is constituted by three main clumps that are acted on by magnetic fields that have different large-scale structural properties. These differences may be the reason for the observed distribution of pre- and protostellar objects along the molecular cloud and the cloud’s apparent evolutionary stage. On the other hand, assuming that the magnetic field is composed of large-scale and turbulent components, we find that the latter is rather similar in all three clumps. The estimated plane-of-sky component of the large-scale magnetic field ranges from about 70 to 200 μG in these clumps. The intensity increases toward the Galactic plane. The mass-to-magnetic flux ratio is much smaller than unity, implying that Lupus I is magnetically supported on large scales.

79 ASTRONOMY AND ASTROPHYSICS↗

A novel analysis method for paired-sample microbial ecology experiments

Many microbial ecology experiments use sequencing data to measure a community s response to an experimental treatment. In a common experimental design, two units, one control and one experimental, are sampled before and after the treatment is applied to the experimental unit. The four resulting samples contain information about the dynamics of organisms that respond to the treatment, but there are no analytical methods designed to extract exactly this type of information from this configuration of samples. Here we present an analytical method specifically designed to visualize and generate hypotheses about microbial community dynamics in experiments that have paired samples and few or no replicates. The method is based on the Poisson lognormal distribution, long studied in macroecology, which we found accurately models the abundance distribution of taxa counts from 16S rRNA surveys. To demonstrate the method s validity and potential, we analyzed an experiment that measured the effect of crude oil on ocean microbial communities in microcosm. Our method identified known oil degraders as well as two clades, Maricurvus and Rhodobacteraceae, that responded to amendment with oil but do not include known oil degraders. Furthermore, our approach is sensitive to organisms that increased in abundance only in the experimental unit but less sensitive to organisms that increased in both control and experimental units, thus mitigating the role of bottle effects .

59 BASIC BIOLOGICAL SCIENCES↗

Oak ridge national laboratory automated clean chemistry for bulk analysis of environmental swipe samples

To shorten the lengthy and costly manual chemical purification procedures, sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment. This addresses a serious need in the nuclear safeguards community to debottleneck the separation of U and Pu in environmental samples—currently performed by overburdened chemists—with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc., the prepFAST-MC2 was designed based on current COTS equipment that was modified for U/Pu separations utilizing Eichrom™ TEVA and UTEVA resins. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined column calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. The reproducibility of the automated system was tested with samples containing 30 ng U and 15 pg Pu, which were separated in a series with alternating reagent blanks. These experiments showed very good washout of both the resin and the sample from the columns as evidenced by low blank values. Analysis of the major and minor isotope ratios for U and Pu provided values well within data quality limits for the International Atomic Energy Agency. Additionally, system process blanks spiked with 233U and 244Pu tracers were separated using the automated system after it was moved outside of a clean room and yielded levels equivalent to clean room blanks, confirming that the system can produce high quality results without the need for expensive clean room infrastructure. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced costs by limiting personnel hours dedicated to the chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigations into the Ternary NaF-KF-UF4 Salt System – Phase A

A knowledge gap exists in the data and understanding of fresh fuel salt and irradiated multicomponent fuel salt systems thermophysical properties. Quantifying these properties is necessary for the design and construction of test reactors, as well as the licensing of future commercial molten-salt reactors. To facilitate thermal property determination on a proposed fuel salt composition for Seaborg Technologies, several samples containing depleted uranium tetrafluoride (UF4), sodium fluoride (NaF), and potassium fluoride (KF) were blended, and a melt temperature analysis was performed. From the melting temperature analysis, it was determined that sample Seaborg-7, a ternary salt composition of 26.4UF4-24.7KF-48.9NaF (mol%), was very near a ternary eutectic point. Therefore, thermal properties such as melting temperature, salt stability, density, heat capacity, thermal diffusivity, and viscosity were experimentally determined on the Seaborg-7 salt. These measurements document the baseline properties of fresh fuel salt as a function of temperature, where future experiments on irradiated fuel salt will provide a holistic perspective on the change of thermophysical properties during reactor operations. Several precision instruments were used to collect property data, and instrument calibrations and data collection were performed and documented in a standardized and reproducible manner with meticulous detail. This process ensured that the measurement procedures and resulting data can readily be duplicated elsewhere. The Seaborg-7 salt was shown to be stable at temperatures up to 900°C, as no mass change was observed upon repeated heating and cooling. The peak melting temperature was determined to be 547°C (557°C endset). The enthalpy of fusion (??H?_fus^o) was determined to be 167.5 ± 2.7 J/g while the enthalpy of crystallization (??H?_c^o) was determined to be -147.8 ± 13.3 J/g. In addition to the eutectic melting peak, upon heating, several pre eutectic peaks were observed, occurring at 470°C (onset) and 499°C (peak). Specific heat capacity measurements showed a slightly increasing trend with respect to temperature in the solid phase, while the liquid-specific heat capacity showed a somewhat flat trend with an average value of 106.1 ± 1.24 J/mol·K between 600 to 800°C. Three independent trials using the Seaborg-7 salt determined the density to be ?(T) = 4.908 – 0.000363·T(°C), validated between 32 to 200°C, and ?(T) = 4.808 – 0.00113·T(°C), validated between ~575 to 850°C. Thermal diffusivity was determined for the liquid state and is represented by the linear equation y = 0.1581 + 0.000207·T(°C) between 550 to 850°C. The viscosity was determined from 600 to 800°C and is represented by the exponential fit equation, ? (mPa·s) = 736.58e^(-0.006·T(°C)). This report documents the conclusion of fuel salt thermophysical property measurements for the Seaborg SPP, Phase A project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LOW-MASS ACTIVE GALACTIC NUCLEI WITH RAPID X-RAY VARIABILITY

We present a detailed study of the optical spectroscopic properties of 12 active galactic nuclei (AGNs) with candidate low-mass black holes (BHs) selected by Kamizasa et al. through rapid X-ray variability. The high-quality, echellette Magellan spectra reveal broad Hα emission in all the sources, allowing us to estimate robust virial BH masses and Eddington ratios for this unique sample. We confirm that the sample contains low-mass BHs accreting at high rates: the median M{sub BH} = 1.2 × 10{sup 6} M{sub ⊙} and median L{sub bol}/L{sub Edd} = 0.44. The sample follows the M{sub BH}–σ{sub *} relation, within the considerable scatter typical of pseudobulges, the probable hosts of these low-mass AGNs. Various lines of evidence suggest that ongoing star formation is prevalent in these systems. We propose a new strategy to estimate star formation rates in AGNs hosted by low-mass, low-metallicity galaxies, based on modification of an existing method using the strength of [O ii] λ3727, [O iii] λ5007, and X-rays.

79 ASTRONOMY AND ASTROPHYSICS↗

SDSS-IV MaNGA: Unveiling Galaxy Interaction by Merger Stages with Machine Learning

We use machine-learning techniques to classify galaxy merger stages, which can unveil physical processes that drive the star formation and active galactic nucleus (AGN) activities during galaxy interaction. The sample contains 4690 galaxies from the integral field spectroscopy survey SDSS-IV MaNGA and can be separated into 1060 merging galaxies and 3630 nonmerging or unclassified galaxies. For the merger sample, there are 468, 125, 293, and 174 galaxies (1) in the incoming pair phase, (2) in the first pericentric passage phase, (3) approaching or just passing the apocenter, and (4) in the final coalescence phase or post-mergers. With the information of projected separation, line-of-sight velocity difference, Sloan Digital Sky Survey (SDSS) gri images, and MaNGA Hα velocity map, we are able to classify the mergers and their stages with good precision, which is the most important score to identify interacting galaxies. For the two-phase classification (binary; nonmerger and merger), the performance can be high (precision > 0.90) with LGBMClassifier . We find that sample size can be increased by rotation, so the five-phase classification (nonmerger, and merger stages 1, 2, 3, and 4) can also be good (precision > 0.85). The most important features come from SDSS gri images. The contribution from the MaNGA Hα velocity map, projected separation, and line-of-sight velocity difference can further improve the performance by 0%–20%. In other words, the image and the velocity information are sufficient to capture important features of galaxy interactions, and our results can apply to all the MaNGA data, as well as future all-sky surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid, specific determination of iodine and iodide by combined solid-phase extraction/diffuse reflectance spectroscopy

A new, rapid methodology for trace analysis using solid-phase extraction is described. The two-step methodology is based on the concentration of an analyte onto a membrane disk and on the determination by diffuse reflectance spectroscopy of the amount of analyte extracted on the disk surface. This method, which is adaptable to a wide range of analytes, has been used for monitoring ppm levels of iodine and iodide in spacecraft water. Iodine is used as a biocide in spacecraft water. For these determinations, a water sample is passed through a membrane disk by means of a 10-mL syringe that is attached to a disk holder assembly. The disk, which is a polystyrene-divinylbenzene composite, is impregnated with poly(vinylpyrrolidone) (PVP), which exhaustively concentrates iodine as a yellow iodine-PVP complex. The amount of concentrated iodine is then determined in only 2 s by using a hand-held diffuse reflectance spectrometer by comparing the result with a calibration curve based on the Kubelka-Munk function. The same general procedure can be used to determine iodide levels after its facile and exhaustive oxidation to iodine by peroxymonosulfate (i.e., Oxone reagent). For samples containing both analytes, a two-step procedure can be used in which the iodide concentration is calculated from the difference in iodine levels before and after treatment of the sample with peroxymonosulfate. With this methodology, iodine and iodide levels in the 0.1-5.0 ppm range can be determined with a total workup time of approximately 60 s with a RSD of approximately 6%.

Non-NASA Center↗

Deep-Sea Hydrothermal-Vent Sampler

An apparatus is being developed for sampling water for signs of microbial life in an ocean hydrothermal vent at a depth of as much as 6.5 km. Heretofore, evidence of microbial life in deep-sea hydrothermal vents has been elusive and difficult to validate. Because of the extreme conditions in these environments (high pressures and temperatures often in excess of 300 C), deep-sea hydrothermal- vent samplers must be robust. Because of the presumed low density of biomass of these environments, samplers must be capable of collecting water samples of significant volume. It is also essential to prevent contamination of samples by microbes entrained from surrounding waters. Prior to the development of the present apparatus, no sampling device was capable of satisfying these requirements. The apparatus (see figure) includes an intake equipped with a temperature probe, plus several other temperature probes located away from the intake. The readings from the temperature probes are utilized in conjunction with readings from flowmeters to determine the position of the intake relative to the hydrothermal plume and, thereby, to position the intake to sample directly from the plume. Because it is necessary to collect large samples of water in order to obtain sufficient microbial biomass but it is not practical to retain all the water from the samples, four filter arrays are used to concentrate the microbial biomass (which is assumed to consist of particles larger than 0.2 m) into smaller volumes. The apparatus can collect multiple samples per dive and is designed to process a total volume of 10 L of vent fluid, of which most passes through the filters, leaving a total possibly-microbe-containing sample volume of 200 mL remaining in filters. A rigid titanium nose at the intake is used for cooling the sample water before it enters a flexible inlet hose connected to a pump. As the water passes through the titanium nose, it must be cooled to a temperature that is above a mineral-precipitation temperature of 100 C but below the upper working temperature (230 C) of switching valves and tubes in the apparatus. The sample water then passes into a manifold tube, from whence the switching valves can direct the water through either a bypass tube or any one of the filter arrays, without contamination from a previous sample. Each filter array consists of series of filters having pore sizes decreasing in the direction of flow: 90-, 60-, 15-, and 7-micron prefilters and a large-surface-area 0.2-micron collection filter. All the filter taps are located between the intake and the bypass tube so that each time the bypass tube is used, the entire manifold tube is flushed as well.

Behar, Alberto E.↗

A Study of the Curation Protocol by Sample Analysis Working Team (SAWT) in Martian Moons eXploration (MMX) Project

Japan Aerospace Exploration Agency (JAXA) will launch a spacecraft in 2024 for a sample return mission from Phobos (Martian Moons eXploration: MMX). The major scientific goals of MMX are to constrain (1) the origin of Phobos and Deimos and (2) the evolution of the Mars-moon system [1]. The touchdown operations are planned to be performed twice at different landing sites on the Phobos surface to collect > 10 g of the surface materials [2]. After the return to the Earth, the Phobos samples will be collected from the individual sample canisters and introduced to the clean chamber installed at ISAS (Institute of Space and Astronautical Science). The Sample Analysis Working Team (SAWT) of MMX designed the procedure of Phobos sample analysis mainly conducted by the initial analysis teams [3]. For the next step, the SAWT will define the procedure of the curation process (mostly non-destructive analysis) of the Phobos samples, which will be presented here. The protocols of the Phobos sample curation is illustrated in figure 1. First, the headspace gas from the sample container will be collected during the Quick Analysis phase. The Quick Analysis will be operated by the sampler and curation teams in ISAS/JAXA. The terrestrial leak and contamination from the sampling systems will be tested using a quadrupole mass spectrometer equipped with a gas sampling system. Second, the bulk Phobos sample will be observed in the clean chamber under purified-N2 gas with an ambient condition (Pre-basic Characterization). This phase will be operated by the curation team in ISAS/JAXA and the instrument team of the MMX mission. The consistency between the data from the instruments in the clean chamber and the spacecraft will then be evaluated. Subsequently, the curation will distribute the small amount of Phobos samples to the Initial analysis team of MMX to conduct the "Preliminary Examination". The objectives of the preliminary examination are to provide (1) feedback on the subsequent sample allocation process, (2) preliminary scientific results that will address parts of MMX mission goals, and (3) evaluation of the sampling system and terrestrial alteration on Phobos samples. Because multiple models are proposed for the origin of Phobos [1] (e.g., giant impact, the capture of asteroids), the chemical and mineralogical characteristics of Phobos must be assessed before the allocation of the samples to the individual initial analysis teams. Simultaneously, the curation team in JAXA will observe the individual grains and aliquots of the samples in the clean chamber (Basic Characterization).

R Fukai↗

Formulation, Casting, and Evaluation of Paraffin-Based Solid Fuels Containing Energetic and Novel Additives for Hybrid Rockets

This investigation studied the inclusion of various additives to paraffin wax for use in a hybrid rocket motor. Some of the paraffin-based fuels were doped with various percentages of LiAlH4 (up to 10%). Addition of LiAlH4 at 10% was found to increase regression rates between 7 - 10% over baseline paraffin through tests in a gaseous oxygen hybrid rocket motor. Mass burn rates for paraffin grains with 10% LiAlH4 were also higher than those of the baseline paraffin. RDX was also cast into a paraffin sample via a novel casting process which involved dissolving RDX into dimethylformamide (DMF) solvent and then drawing a vacuum on the mixture of paraffin and RDX/DMF in order to evaporate out the DMF. It was found that although all DMF was removed, the process was not conducive to generating small RDX particles. The slow boiling generated an inhomogeneous mixture of paraffin and RDX. It is likely that superheating the DMF to cause rapid boiling would likely reduce RDX particle sizes. In addition to paraffin/LiAlH4 grains, multi-walled carbon nanotubes (MWNT) were cast in paraffin for testing in a hybrid rocket motor, and assorted samples containing a range of MWNT percentages in paraffin were imaged using SEM. The fuel samples showed good distribution of MWNT in the paraffin matrix, but the MWNT were often agglomerated, indicating that a change to the sonication and mixing processes were required to achieve better uniformity and debundled MWNT. Fuel grains with MWNT fuel grains had slightly lower regression rate, likely due to the increased thermal conductivity to the fuel subsurface, reducing the burning surface temperature.

Larson, Daniel B.↗

Arcing in space structures in low Earth orbit

This report describes results of an experimental and theoretical program to investigate arcing of structures containing dielectric and conducting materials when they are biased negatively with respect to a plasma. An argon ion source generated Ar(+) ions of directed energy 20 to 40 eV and density approximately 10(exp 7) cm(exp -3) that impinged upon samples containing a dielectric material on top of a negatively biased Kovar plate. Arcing events were studied for bias voltages between -300 and -1000V with respect to the ion beam. The samples were Dow Corning 93-500 adhesive on Kovar, fused silica cover slips bonded on Kovar, and silicon solar cells mounted on Kovar. Measurements of discharge current, Kovar plate voltage, and radiation from the arc versus time were carried out. Microsecond duration exposure images and optical spectra in the 0.24 to 0.40 micron band were also acquired during arcing events. Arcing events were found to be associated with exposed adhesive and means were found to eliminate arcing altogether. The charging of a silica cover plate and the fields around the plate were calculated using a particle-in-cell code. Models were developed to explain the ignition of the arc and the physical processes occurring during the discharge.

Upschulte, B. L.↗

An organogel library for solution NMR analysis of nanoparticle suspensions in non-aqueous samples

Surface contrast solution NMR methods (scNMR) are emerging as powerful tools to investigate the adsorption of small molecule ligands to the surface of nanoparticles (NP), returning fundamental insight into the kinetics and thermodynamics of sorption, as well as structural information on the adsorbed species. A prerequisite for the acquisition of high quality solution NMR data is the preparation of homogeneous and stable samples that return consistent NMR spectra and allow extensive signal averaging. Unfortunately, this condition does not apply to NMR samples containing NPs that often show a tendency to sediment and accumulate at the bottom of the NMR tube over the course of the experiment. We have recently shown that preparing NMR samples in an agarose gel matrix inhibits sedimentation and allows the characterization of small molecule-NP interactions by scNMR. Unfortunately, as the agarose gel only forms in aqueous solution, this sample preparation method cannot be used to stabilize NP suspensions in a non-aqueous environment. In this work, we introduce a library of 48 organogels, based on low molecular-mass organic gelators (LMOGs), to prepare NMR samples of small molecule/NP systems in a wide range of organic solvents. In addition, we present a simple method that takes advantage of 1H transverse relaxation (1H-R2) measurements to screen the library and identify the best gelator to characterize the small molecule-NP interaction of interest in the solvent of choice. We expect the results of this study will enable the preparation of homogeneous and stable samples of NPs in non-aqueous environments, therefore dramatically increasing the applicability of scNMR to the characterization of heterogeneous interactions and to the investigation of the role played by solvent molecules in regulating the kinetics and thermodynamics of sorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Potential candidate genomic biomarkers of drug induced vascular injury in the rat

Drug-induced vascular injury is frequently observed in rats but the relevance and translation to humans present a hurdle for drug development. Numerous structurally diverse pharmacologic agents have been shown to induce mesenteric arterial medial necrosis in rats, but no consistent biomarkers have been identified. To address this need, a novel strategy was developed in rats to identify genes associated with the development of drug-induced mesenteric arterial medial necrosis. Separate groups (n = 6/group) of male rats were given 28 different toxicants (30 different treatments) for 1 or 4 days with each toxicant given at 3 different doses (low, mid and high) plus corresponding vehicle (912 total rats). Mesentery was collected, frozen and endothelial and vascular smooth muscle cells were microdissected from each artery. RNA was isolated, amplified and Affymetrix GeneChip Registered-Sign analysis was performed on selectively enriched samples and a novel panel of genes representing those which showed a dose responsive pattern for all treatments in which mesenteric arterial medial necrosis was histologically observed, was developed and verified in individual endothelial cell- and vascular smooth muscle cell-enriched samples. Data were confirmed in samples containing mesentery using quantitative real-time RT-PCR (TaqMan Trade-Mark-Sign ) gene expression profiling. In addition, the performance of the panel was also confirmed using similarly collected samples obtained from a timecourse study in rats given a well established vascular toxicant (Fenoldopam). Although further validation is still required, a novel gene panel has been developed that represents a strategic opportunity that can potentially be used to help predict the occurrence of drug-induced mesenteric arterial medial necrosis in rats at an early stage in drug development. -- Highlights: Black-Right-Pointing-Pointer A gene panel was developed to help predict rat drug-induced mesenteric MAN. Black-Right-Pointing-Pointer A gene panel was identified following treatment of rats with 28 different toxicants. Black-Right-Pointing-Pointer There was a strong correlation of genes and histologic evidence of mesenteric MAN. Black-Right-Pointing-Pointer Many genes were also regulated prior to histologic evidence of arterial effects.

60 APPLIED LIFE SCIENCES↗

THE FAINT END OF THE LUMINOSITY FUNCTION AND LOW SURFACE BRIGHTNESS GALAXIES

Smithsonian Hectospec Lensing Survey (SHELS) is a dense redshift survey covering a 4 deg{sup 2} region to a limiting R = 20.6. In the construction of the galaxy catalog and in the acquisition of spectroscopic targets, we paid careful attention to the survey completeness for lower surface brightness dwarf galaxies. Thus, although the survey covers a small area, it is a robust basis for computation of the slope of the faint end of the galaxy luminosity function to a limiting M{sub R} = -13.3 + 5log h. We calculate the faint-end slope in the R band for the subset of SHELS galaxies with redshifts in the range 0.02 {<=}z < 0.1, SHELS{sub 0.1}. This sample contains 532 galaxies with R < 20.6 and with a median surface brightness within the half-light radius of SB{sub 50,R} = 21.82 mag arcsec{sup -2}. We used this sample to make one of the few direct measurements of the dependence of the faint end of the galaxy luminosity function on surface brightness. For the sample as a whole the faint-end slope, {alpha} = -1.31 {+-} 0.04, is consistent with both the Blanton et al. analysis of the Sloan Digital Sky Survey and the Liu et al. analysis of the COSMOS field. This consistency is impressive given the very different approaches of these three surveys. A magnitude-limited sample of 135 galaxies with optical spectroscopic redshifts with mean half-light surface brightness, SB{sub 50,R} {>=} 22.5 mag arcsec{sup -2} is unique to SHELS{sub 0.1}. The faint-end slope is {alpha}{sub 22.5} = -1.52 {+-} 0.16. SHELS{sub 0.1} shows that lower surface brightness objects dominate the faint-end slope of the luminosity function in the field, underscoring the importance of surface brightness limits in evaluating measurements of the faint-end slope and its evolution.

79 ASTRONOMY AND ASTROPHYSICS↗