Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COLD WORKING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Preconceptual Designs of Coupled Power Delivery between a 4-Loop PWR and 100-500 MWe HTSE Plants

This study develops a preconceptual design for the integration between a large-scale high-temperature electrolysis facility and a NPP. Two hydrogen facility sizes are considered: 100 MWnom and 500 MWnom. Both steam supply designs use cold reheat steam extraction as a heat source. A reboiler inside the protected area of the power plant transfers steam heat to the demineralized water supply for the hydrogen plant. After the heat transfer, the extracted steam condenses and returns to the condenser while the process steam routes out of the protected area to the electrolyzers. Electrical power is tapped off from the high voltage side of the GSU transformer, where it is then transported via a 345-kV transmission line to the hydrogen facility. Circuit breakers and disconnects are located at both ends of the transmission line. Step down transformers and miscellaneous switchgear/buses are located at the end of the transmission line inside the HTEF boundary. Control capabilities for the steam interfacing equipment and electrical dispatch are accessible from the Main Control Room, and protective relays for the transmission line are located inside the Relay Room. Computer modeling was performed for the thermal and electrical designs. PEPSE analysis provided the steady-state parameters for thermal extraction from the turbine cycle. These parameters were used to inform transients and size equipment in combination with Applied Flow Technology (AFT) Arrow and AFT Fathom modeling for steam and water piping, respectively. Electrical transients were analyzed using PSCAD. An ETAP model was used to evaluate power flow and short circuit, which enabled the sizing of transformers and protective equipment. A cost estimate was developed for both integration designs when considering plant separation distances of 250 m and 500 m. From these estimates, the modifications for thermal and electrical interfacing of a first-of-a-kind nuclear-integrated hydrogen facility are anticipated to cost between $60–250/kWnom., where the subscript “nom” refers to the nominal size of the hydrogen plant. On a thermal power basis, the thermal power has a cost of approximately $8/MWth for a 500 MWnom high temperature electrolysis plant located 500 m distant from the NPP. That value decreases to approximately $7.5/MWth for a 250 m separation distance between the hydrogen plant and the NPP. This value is lower than previous estimates of the cost of heat extracted from NPPs primarily because in this work the steam is extracted from cold reheat instead of the main steam line, which reduces the cost of the dispatched steam by approximately $3.5/MWth. Nuclear steam extraction can provide a profit avenue for many plants and is not restricted to hydrogen production. Ammonia production, oil refining, and paper production, among other industrial processes all require thermal energy, which can be provided by NPPs. Future work should look further at the details of thermal extraction for a variety of use cases. This can include increased levels of extraction and multiple simultaneous users. Additionally, site-specific studies should be performed to develop industry experience and improve cost accuracy.

08 HYDROGEN↗

Accelerated corrosion testing of cold spray coatings on 304L in chloride environments

Cold spray is an advanced metal manufacturing technique applied across many fields for a wide range of functions. Low heat input and compressive stresses induced into the substrate by the cold spray process makes it a promising choice for protective corrosion resistant coatings. One potential application for cold spray is as a protective coating against corrosion for spent nuclear fuel (SNF) interim dry storage canisters. As these canisters are currently stored at interim storage locations longer than originally intended, chloride induced stress corrosion cracking has been identified as a high priority knowledge gap, specifically with respect to prolonging or extending canister lifetimes ( Teague et al., 2019 ). The high deployability of cold spray, for which nozzles have been developed for application in constrained spaces, in conjunction with beneficial properties inherent to cold spray makes this a good candidate for a corrosion protection coating on SNF canisters. This work explores a pathway to rapidly down-select cold spray coatings for canisters by focusing on the corrosion properties. Specifically, this study examines the corrosion protection abilities of nickel and nickel-based alloy cold spray coatings on 304 L stainless steel in chloride rich environments through electrochemical scans and ferric chloride pitting tests (ASTM G48 Method A). It was shown that the porosity of the coating, the processing gas, material selection, and deformation in the substrate all impact the corrosion behavior of cold spray coatings and are areas where optimization could reduce potential materials degradation, enabling enhanced coatings development.

Karasz, Erin K.↗

Investigation of Cold Spray as a Dry Storage Canister Repair and Mitigation Tool

The lack of a permanent spent nuclear fuel repository means utilities are faced with extending licenses for dry cask storage systems (DCSS) canisters far beyond their original 20-year license period. DCSS canisters are made from austenitic stainless steels (SSs) and fabricated using fusion welds. High heat input and melting associated with fabrication welds causes material around the weld to be susceptible to chloride-induced stress corrosion cracking (CISCC). The purpose of the work reported here is to investigate the use of cold spray for repair and mitigation of CISCC in DCSS canisters to ensure integrity far beyond their original license period. This report presents an analysis of cold spray for canister life extension, a summary of related efforts, relevant technology down selections, work accomplished, and future efforts relative to use of cold spray for repair and mitigation of CISCC in DCSS canisters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Decommissioning of the 247-F Fuel Manufacturing Facility at the Savannah River Site (SRS)

Building 247-F at SRS was a roughly 110,000 ft{sup 2} two-story facility designed and constructed during the height of the cold war naval buildup to provide additional naval nuclear fuel manufacturing capacity in early 1980's. The manufacturing process employed a wide variety of acids, bases, and other hazardous materials. As the need for naval fuel declined, the facility was shut down and underwent initial deactivation, which was completed in 1990. All process systems were flushed with water and drained using the existing process drain valves. However, since these drains were not always installed at the lowest point in piping and equipment systems, a significant volume of liquid remained after initial deactivation. After initial deactivation, a non-destructive assay of the process area identified approximately 17 ({+-}100%) kg of uranium held up in equipment and piping. The facility was placed in Surveillance and Maintenance mode until 2003, when the decision was made to perform final deactivation, and then decommission the facility. The following lessons were learned as a result of the D and D of building 247-F. Successful D and D of a major radiochemical process building requires significant up-front planning by a team of knowledgeable personnel led by a strong project manager. The level of uncertainty and resultant risk to timely, cost effective project execution was found to be high. Examples of the types of problems encountered which had high potential to adversely impact cost and schedule performance are described below. Low level and sanitary waste acceptance criteria do not allow free liquids in waste containers. These liquids, which are often corrosive, must be safely removed from the equipment before it is loaded to waste containers. Drained liquids must be properly managed, often as hazardous or mixed waste. Tapping and draining of process lines is a dangerous operation, which must be performed carefully. The temptation to become complacent when breaking into lines is great. Incidents of personnel exposure to liquids during draining are likely. Records from the initial 1990 deactivation led early work planners to assume the facility was cold, dark and dry. This turned out to be a poor assumption. Work instructions had to be modified to require that engineers evaluate each of several hundred process lines to identify the low point, where a tap and drain system could be installed to allow positive verification that the line was empty before the line was cut for removal. During the period between facility shut down in 1990 and the start of final deactivation in 2003, roof leaks had developed, allowing rain water to enter building 247-F, which provided an environment for mold growth. Sampling confirmed the presence of Stachybotrys chartarum, a toxic indoor mold that grows on wet cellulosic material, such as drywall paper. D and D workers in areas where this hazard was identified were required to where proper personal protective equipment, which complicated work execution. Discovery of the potential presence of uniquely hazardous chemicals such as shock sensitive compounds and toxic uranium hexafluoride became issues which required investigation and special handling strategies. Team access to subject matter experts, who could quickly provide the required guidance for safe material handling, was critical to keeping the project on schedule. In old legacy facilities, it is possible that the D and D workers will be exposed to undocumented energy sources such as energized electrical conductors and pipes containing hazardous materials that originate outside the boundaries of the facility. Significant effort must be expended on adequate mechanical and electrical isolation. Subdividing the facility into well defined zones for which detailed zone-specific end points could be developed proved to be a highly effective project management strategy. Waste management must be carefully planned. The rate of waste generation as the facility is converted from a structure to waste can frequently exceed the D and D team's resources to characterize, package, store and transport the waste to a disposal facility in a timely manner. This can lead to schedule delays and/or increased project cost.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dispersion relations of nonlinearly coupled electromagnetic and electrostatic waves in relativistic plasmas

In the present work large amplitude electromagnetic waves in cold plasmas at relativistic intensities are studied analytically in a plane wave geometry. Special attention is drawn to the nonlinear coupling of electromagnetic and electrostatic modes. In the framework of the Akhiezer-Polovin model, periodic and more general quasiperiodic waves are taken into account. For small densities a two-time-scale method is used to calculate an analytical solution up to the fourth order in the plasma density. Nonlinear dispersion relations are calculated for coupled waves, taking into account the full plasma response for linear as well as for circular polarization. In the presence of a large amplitude electrostatic wave, the results show a major difference from the commonly considered dispersion relation for electromagnetic waves. Finally, the solutions of the Akhiezer-Polovin model are compared with particle-in-cell simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Argonaut - A Robotic System for Cryogenic Environments

Fermilab and the HEP community invest significant resources into liquid argon detectors. The largest and most expensive of these detectors will be located in the Deep Underground Neutrino Experiment (DUNE). However, recent experiences have shown that there are limited avenues of monitoring, intervention, and interaction in the internal liquid environment. This proposal shows a technological path that could provide a valuable tool to ensure or at least improve the management of these HEP detectors. The development of a robotic system named Argonaut will demonstrate several technologies including 1) demonstration of suitable mobility of a small robotic device at liquid argon temperatures, 2) demonstration of wireless communication, 3) demonstration of improved diagnostics capabilities - such as tunable optics with motion control, 4) demonstration of interconnectivity of a robotic system with hardware residing within the detector. This initial research will be a seed for extended development in cold robotics and associated technologies. This work will allow FNAL to contribute a significant technology capability to recent efforts to cryogenic detector operations.

43 PARTICLE ACCELERATORS↗

Socially Driven HVAC Optimization Federal Building and US Courthouse Phoenix, Arizona

Under many circumstances in facilities management, keeping occupants comfortable and saving energy are diametrically opposed. To stay cool in summer and warm in winter requires energy to maintain indoor temperatures. If energy is saved by allowing indoor temperatures to get warmer in the summer or colder in winter, occupants’ comfort levels decrease. There is great potential to reduce costs and maintain occupant comfort if a system existed that could break this diametric opposition. The comfort of building occupants in today’s facilities is controlled by maintaining a given space temperature through the use of a thermostat. These devices operate in a very simple manner in which they are set to maintain a certain constant space temperature range. If the occupant is too hot or cold, he or she writes a work order for facility maintenance staff to adjust the thermostat to a new constant temperature range. This feedback cycle is repeated as needed to avoid generating complaints of too hot/cold from the occupants. This system has two areas in which it can be improved. First, there is the labor cost associated with a facilities maintenance person having to respond to each request when an occupant is uncomfortable. Person-hours are spent receiving the work order and adjusting space thermostats to a level that, hopefully, will allow the occupant to be comfortable. Second, the space temperature is maintained within a constant range, with no effort being made to finetune the space temperature to a setting that conserves energy while maintaining occupant comfort. Occupant comfort is based upon many more factors than just the space temperature. When other factors are taken into account, there is potential to save energy while maintaining that comfort level.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving efficiency of existing air-conditioning

Inexpensive duct work changes improves hot-and-cold deck air conditioning units. Energy cost of reheating cooled air can be eliminated by tying all cold air decks to one air-conditioning unit and all hot decks to another. Resultant energy savings are easily possible with two or more units.

Obler, H. D.↗

Systems special investigation group overview

The Systems Special Investigation Group (SIG) has undertaken investigations in the four major engineering disciplines represented in the Long Duration Exposure Facility (LDEF) hardware: electrical, mechanical, thermal, and optical systems. Testing was planned for the highest possible level of assembly, and top level system tests for nearly all systems were performed at this time. To date, testing was performed on a mix of LDEF and individual experimenter systems. No electrical or mechanical system level failures attributed to the spaceflight environment have yet been detected. Some low cost electrical components were used successfully, although relays were a continuing problem. Mechanical galling was observed unexpectedly, but no evidence of cold welding was identified yet. A working index of observed systems anomalies was created and will be used to support the tracking and resolution of these effects. The LDEF hardware currently available to the Systems SIG includes most of the LDEF systems hardware, and some significant experimenter hardware as well. A series of work packages was developed for each of several subsystem types where further testing is of critical interest. The System SIG is distributing a regular newsletter to the greater LDEF community in order to maintain coherence in an investigation which is widely scattered both in subject matter and in geography. Circulation of this informal document has quadrupled in its first year.

Mason, James B.↗

Evaluation of dual flow thrust vector nozzles with exhaust stream impingement

To supplement previous work performed by NASA, a cold-jet facility was established at the California Polytechnic State University, San Luis Obispo campus. The purpose of this facility is to continue the studies of cold flow multiaxis thrust vectoring conducted at the NASA Langley Research Center. A single nozzle test apparatus was completed and is presently operational. Included are the results of the single flow test envelope that was requested by NASA personnel. Details about the test apparatus are included in the Cal Poly Semi-Annual Progress report.

Carpenter, Thomas W.↗

Cold Start of a Radiator Equipped with Titanium-Water Heat Pipes

Radiator panels utilizing titanium-water heat pipes are being considered for lunar applications. A traditional sandwich structure is envisioned where heat pipes are embedded between two high thermal conductivity face sheets. The heat pipe evaporators are to be thermally connected to the heat source through one or more manifolds containing coolant. Initial radiator operation on the lunar surface would likely follow a cold soak where the water in the heat pipes is purposely frozen. To achieve heat pipe operation, it will be necessary to thaw the heat pipes. One option is to allow the sunlight impinging on the surface at sunrise to achieve this goal. Testing was conducted in a thermal vacuum chamber to simulate the lunar sunrise and additional modeling was conducted to identify steady-state and transient response. It was found that sunlight impinging on the radiator surface at sunrise was insufficient to solely achieve the goal of thawing the water in the heat pipes. However, starting from a frozen condition was accomplished successfully by applying power to the evaporators. Start up in this fashion was demonstrated without evaporator dryout. Concern is raised over thawing thermosyphons, vertical heat pipes operating in a gravity field, with no wick in the condenser section. This paper presents the results of the simulated cold start study and identifies future work to support radiator panels equipped with titanium-water heat pipes.

Jaworske, Donald A.↗

Outreach to Scientists and Engineers at the Hanford Technical Library

Staff at the Hanford Technical Library has developed a suite of programs designed to help busy researchers at the Pacific Northwest National Laboratory (PNNL) make better use of library products and services. Programs include formal training classes, one-on-one consultations, and targeted email messages announcing new materials to researchers in specific fields. A staple of outreach has been to teach classes to library clients covering research tools in their fields. These classes started out in the library classroom and then expanded to other venues around PNNL. Class surveys indicated that many researchers desired a practical approach to learning rather than the traditional lecture format. The library instituted “Library Learning Day” and hosted classes in the PNNL computer training room to provide lab employees with a hands-on learning experience. Classes are generally offered at noon and lab staff attends classes on their lunch hour. Many just do not have time to spend a full hour in training. Library staff added some experimental half-hour mini classes in campus buildings geared to the projects and interests of researchers there to see if this format was more appealing. As other programs have developed librarians are teaching fewer classes but average attendance figures has remained fairly stable from 2005-2007. In summer of 2004 the library began the Traveling Librarian program. Librarians call-on groups and individuals in 24 buildings on the Richland Washington campus. Five full-time and two part-time librarians are involved in the program. Librarians usually send out email announcements prior to visits and encourage scientists and engineers to make appointments for a brief 15 minute consultation in the researcher’s own office. During the meeting lab staff learn about products or product features that can help them work more productively. Librarians also make cold calls to staff that do not request a consultation and may not be making full use of the library. Scientists and engineers who require longer sessions can arrange half-hour training appointments in the researcher’s own office or at the library. Since the program was implemented staff made 165 visits to 1249 laboratory staff including some repeat consultation requests. New acquisitions lists are sent to individuals and groups that would be interested in recent journal, database, and books purchases. These lists are topic specific and targeted to groups and individuals with an interest in the field. For example newly acquired engineering resources are targeted at engineering groups. The new acquisitions list for engineering began mid year in 2005. An analysis of circulation statistics for engineering books in fiscal year 2005, 2006, and 2007 show that circulation increased each year with 2007 circulation nearly double that of 2005. This took place when overall circulation rose in FY06 but fell slightly in FY07. Outreach strategies tailored and individualized can be effective. Offering multiple outreach options offers researchers different ways to interact with library staff and services.

99 GENERAL AND MISCELLANEOUS↗

Research Toward Zero Energy Homes: Budget Periods One, Two and Three (January 1, 2008 ‐ December 31, 2010)

This final report was compiled from the detailed annual reports that were submitted for efforts in 2008 and 2009, and from individual task reports from 2010. Reports, case studies, and presentations derived from this work are available through the Building America website. The BIRA team is led by ConSol, a leading provider of energy solutions for builders since 1983. In partnership with over fifty builders, developers, architects, manufactures, researchers, utilities, and agencies, research work was performed in California, Colorado, Utah, New Mexico, Washington, Oregon, and Hawaii and five (5) climate regions (Hot-Dry, Marine, Hot-Humid, Cold, and Hot/Mixed Dry). In addition to research work, the team provided technical assistance to our partners whose interests span the entire building process. During the three year budget period, the BIRA team performed analyses of several emerging technologies, prototype homes, and high performance communities through detailed computer simulations and extensive field monitoring to meet the required climate joule milestone targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cloud Morphology Evolution in Arctic Cold‐Air Outbreak: Two Cases During COMBLE Period

Abstract Cloud feedbacks play an important role in Arctic warming. Cloud morphology, for example, cloud size and spatial distributions, is among key factors that directly impact their radiative effects. In this work, we use two cases observed during the Cold‐air Outbreak (CAO) in the Marine Boundary Layer Experiment (COMBLE) to study the evolution of cloud size distributions as an air mass is advected from the Arctic over a comparatively warm ocean and cloud mesoscale organization changes from rolls to cells. Cloud objects are identified from Moderate Resolution Imaging Spectroradiometer (MODIS) reflectance images through an object segmentation procedure and roll breakup is identified by homogeneities in cloud water path (CWP). Roll breakup is found to be accompanied by a local minimum in wind shear and local maxima in cloud size and marine cold air outbreak index. The mean cloud horizontal aspect ratio has weak fetch dependency and is around 2 in roll, transition, and cell regimes. Regardless of distance from the ice edge, smaller clouds (<10 km 2 ) dominate the population number but not cloud cover. Cloud size distributions show bimodality in transition and cell regimes. For clouds with comparable sizes, mean nearest neighbor distances normalized by equivalent cloud radius converge to a single value for all regimes and for all but the smallest clouds, suggesting that clouds of comparable sizes in CAOs are separated by distance proportional to their sizes. The presented statistical results pave the way to evaluating model simulated cloud organizations during CAO events.

54 ENVIRONMENTAL SCIENCES↗

Probing the transition from shallow to deep convection using ASR data and large-eddy simulations

Over the duration of this project, we have made the following advances. 1) We have developed a novel approach to obtain a Lagrangian view of convection from high-resolution numerical model through Lagrangian tracking. This approach nicely complements the more traditionally used Eulerian statistics. We have applied this approach to a range of problem. 2) We have looked into improving and extending our parameterizations based on stochastically entraining parcels, developed previously for shallow convection. 3) This grant also supported our effort on a paper where we compared cumulus parameterizations and cloud resolving models in terms of their linear response functions. This work will help the community to better evaluate and develop cumulus parameterization. 4) We have applied Lagrangian tracking to shallow convection, deep convection with and without convective organization to better characterize their dynamics and the transition between them. 5) We have devised a novel way of using Lagrangian to identify cold pools, an area identified as of great interest by the ASR community. Our algorithm has a number of advantages and in particular can handle merging cold pools more gracefully than existing techniques. 6) We demonstrated that we can, for the first time, correctly reproduce both the diurnal and seasonal cycle of the hydrologic cycle in the Amazon using a strategy that explicitly represents convection but parameterizes large-scale circulation. In addition we showed that the main cause of the wet season is the presence of an early morning fog, which insulate the surface from top of the atmosphere shortwave radiation. In essence this fog makes the day shorter because radiation cannot penetrate to the surface in the early morning. This is why all fluxes are reduced in the wet season compared to the dry season. 7) We have investigated the life cycle of cold pools and the role of surface diabatic heating. We show that surface heating can kill cold pols and reduce the number of large cold pools and the organization of convection. The effect is quite dramatic over land where the entire distribution of cold pools is modified, and the cold pools are much warmer and more humid with surface diabatic heating below the cold pools. The PI and the co-PI continue to work together on parameterization of cold pools.

54 ENVIRONMENTAL SCIENCES↗

Cold Nuclear Matter Effects at PHENIX

While the study of the quark-gluon plasma has been the primary focus of the RHIC experiments, much work has also been done to understand so-called cold nuclear matter (CNM) eects through d+Au collisions where no hot plasma is produced. Eects such as nuclear shadowing, Cronin enhancement, and initial-state parton energy loss, among others, are not only interesting in their own right, but have direct implications on QGP-related measurements in A+A collisions. Recently PHENIX has measured CNM eects at midrapidity in s_NN = 200 GeV d+Au collisions. Measurements of reconstructed jets reveal the centrality dependence of both jet suppression and broadening of the away-side jet. Meanwhile, single electrons from heavy flavor decays exhibit enhancement, increasing with centrality, over a broad p_T range. J/psi and psi' modification have also been measured and are quite dierent in magnitude, in contrast with our expectations. The above results are presented here and compared to our present understanding of CNM effects.

PHENIX↗

A Preliminary Investigation into the Mitigation of Plug-in Hybrid Electric Vehicle Tailpipe Emissions Through Supervisory Control Methods Part 2: Experimental Evaluation of Emissions Reduction Methodologies

Plug-in hybrid electric vehicle (PHEV) technologies have the potential for considerable petroleum consumption reductions, possibly at the expense of increased tailpipe emissions due to multiple 'cold' start events and improper use of the engine for PHEV specific operation. PHEVs operate predominantly as electric vehicles (EVs) with intermittent assist from the engine during high power demands. As a consequence, the engine can be subjected to multiple cold start events. These cold start events may have a significant impact on the tailpipe emissions due to degraded catalyst performance and starting the engine under less than ideal conditions. On current hybrid electric vehicles (HEVs), the first cold start of the engine dictates whether or not the vehicle will pass federal emissions tests. PHEV operation compounds this problem due to infrequent, multiple engine cold starts. A continuation of previous analytical work, this research, experimentally verifies a vehicle supervisory control system for a pre-transmission parallel PHEV powertrain architecture. Energy management strategies are evaluated and implemented in a virtual environment for preliminary assessment of petroleum displacement benefits and rudimentary drivability issues. This baseline vehicle supervisory control strategy, developed as a result of this assessment, is implemented and tested on actual hardware in a controlled laboratory environment over a baseline test cycle. Engine cold start events are aggressively addressed in the development of this control system, which leads to enhanced pre-warming and energy-based engine warming algorithms that provide substantial reductions in tailpipe emissions over the baseline supervisory control strategy. The flexibility of the PHEV powertrain allows for decreased emissions during any engine starting event through powertrain 'torque shaping' algorithms. The results of the research show that PHEVs do have the potential for substantial reductions in fuel consumption. Tailpipe emissions from a PHEV test platform have been reduced to acceptable levels through the development and refinement of vehicle supervisory control methods only. Impacts on fuel consumption were minimal for the emissions reduction techniques implemented.

02 PETROLEUM↗

Cold air investigation of 4 1/2-stage turbine with stage loading factor of 4.66 and high specific work output. 1: Overall performance

The turbine developed design specific work output at design speed at a total pressure ratio of 6.745 with a corresponding efficiency of 0.855. The efficiency (0.855)was 3.1 points lower than the estimated efficiency quoted by the contractor in the design report and 0.7 of a point lower than that determined by a reference prediction method. The performance of the turbine, which was a forced vortex design, agreed with the performance determined by the prediction method to about the same extent as did the performance of three reference high stage loading factor turbines, which were free vortex designs.

Whitney, W. J.↗