At least 469 records · Page 26

Flux Expulsion Testing for LCLS-II-HE Cavity Production

Nitrogen-doped niobium SRF cavities are sensitive to trapped magnetic flux, which decreases the cavity intrinsic Q₀. Prior experimental results have shown that heat treatments to 900°C and higher can result in stronger flux expulsion during cooldown; the precise temperature required tends to vary by vendor lot/ingot of the niobium material used in the cavity cells. For LCLS-II-HE, to ensure sufficient flux expulsion in all cavities, we built and tested single-cell cavities to determine this required temperature for each vendor lot of niobium material to be used in cavity cells. In this report, we present the results of the single-cell flux expulsion testing and the Q₀ of the nine-cell cavities built using the characterized vendor lots. We discuss mixing material from different vendor lots, examine the lessons learned, and finally present an outlook on possible refinements to the single-cell technique.

43 PARTICLE ACCELERATORS↗

Radionuclide Partitioning in an Underground Nuclear Test Cavity

In 2004, a borehole was drilled into the 1983 Chancellor underground nuclear test cavity to investigate the distribution of radionuclides within the cavity. Sidewall core samples were collected from a range of depths within the re-entry hole and two sidetrack holes. Upon completion of drilling, casing was installed and a submersible pump was used to collect groundwater samples. Test debris and groundwater samples were analyzed for a variety of radionuclides including the fission products {sup 99}Tc, {sup 125}Sb, {sup 129}I, {sup 137}Cs, and {sup 155}Eu, the activation products {sup 60}Co, {sup 152}Eu, and {sup 154}Eu, and the actinides U, Pu, and Am. In addition, the physical and bulk chemical properties of the test debris were characterized using Scanning Electron Microscopy (SEM) and Electron Microprobe measurements. Analytical results were used to evaluate the partitioning of radionuclides between the melt glass, rubble, and groundwater phases in the Chancellor test cavity. Three comparative approaches were used to calculate partitioning values, though each method could not be applied to every nuclide. These approaches are based on: (1) the average Area 19 inventory from Bowen et al. (2001); (2) melt glass, rubble, and groundwater mass estimates from Zhao et al. (2008); and (3) fission product mass yield data from England and Rider (1994). The U and Pu analyses of the test debris are classified and partitioning estimates for these elements were calculated directly from the classified Miller et al. (2002) inventory for the Chancellor test. The partitioning results from this study were compared to partitioning data that were previously published by the IAEA (1998). Predictions of radionuclide distributions from the two studies are in agreement for a majority of the nuclides under consideration. Substantial differences were noted in the partitioning values for {sup 99}Tc, {sup 125}Sb, {sup 129}I, and uranium. These differences are attributable to two factors: chemical volatility effects that occur during the initial plasma condensation, and groundwater remobilization that occurs over a much longer time frame. Fission product partitioning is very sensitive to the early cooling history of the test cavity because the decay of short-lived (t{sub 1/2} < 1 hour) fission-chain precursors occurs on the same time scale as melt glass condensation. Fission product chains that include both volatile and refractory elements, like the mass 99, 125, and 129 chains, can show large variations in partitioning behavior depending on the cooling history of the cavity. Uranium exhibits similar behavior, though the chemical processes are poorly understood. The water temperature within the Chancellor cavity remains elevated (75 C) more than two decades after the test. Under hydrothermal conditions, high solubility chemical species such as {sup 125}Sb and {sup 129}I are readily dissolved and transported in solution. SEM analyses of melt glass samples show clear evidence of glass dissolution and secondary hydrothermal mineral deposition. Remobilization of {sup 99}Tc is also expected during hydrothermal activity, but moderately reducing conditions within the Chancellor cavity appear to limit the transport of {sup 99}Tc. It is recommended that the results from this study should be used together with the IAEA data to update the range in partitioning values for contaminant transport models at the Nevada National Security Site (formerly known as the Nevada Test Site).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel Crab Cavity RF Design – Phase 1

The design and construction of electron-ion colliders, EIC, will be facilitated by the development of an SRF “crab crossing” cavity with 0.5 to 1.5 GHz frequency and 20 to 50 MV of total integrated voltage. The development of RF cavities that provide a transverse kick to the particle beam will include RF design, computer modeling, and hardware development. Current state of the art crab cavities provide 2- 5 MV of integrated voltage, and most of the existing designs require complex schemes to damp unwanted RF modes. We propose a novel design for TEM-like, room-temperature, two-bar structures, or hybrid structures with one resonant bar and one input coax per module, which can also be implemented for SRF conditions. Unwanted modes are coupled out of the cavity by the coax input line, and this provides a uniquely simple method to reduce the strength of higher-order modes. Critical phase stability for the crabbing voltage is provided by the low-level RF system, which controls the RF to the input ports of the novel crab cavity design. Designs for a series of cavities, or for multiple-module cavities, will provide the 20-50 MV of integrated voltage in an electron-ion collider, while meeting the critical thermal and mechanical requirements for heat loads, alignment, and phase stability. RF designs for various module alternatives were evaluated in Phase I. A single module of a hybrid design with one resonant bar and one coax input was built for room-temperature, low-power testing with a bead-pull measurement. Several additional designs were explored that made use of a high RT/Q, voltage-efficient, S-mode structure.

Neubauer, Michael↗

Thin Film Approaches to the SRF Cavity Problem Fabrication and Characterization of Superconducting Thin Films

Superconducting Radio Frequency (SRF) cavities are responsible for the acceleration of charged particles to relativistic velocities in most modern linear accelerators, such as those employed at high-energy research facilities like Thomas Jefferson National Laboratory’s CEBAF and the LHC at CERN. Recognizing SRF as primarily a surface phenomenon enables the possibility of applying thin films to the interior surface of SRF cavities, opening a formidable tool chest of opportunities by combining and designing materials that offer greater performance benefit. Thus, while improvements in radio frequency cavity design and refinements in cavity processing techniques have improved accelerator performance and efficiency – 1.5 GHz bulk niobium SRF cavities have achieved accelerating gradients in excess of 35 MV/m – there exist fundamental material bounds in bulk superconductors limiting the maximally sustained accelerating field gradient (≈ 45 MV/m for Nb) where inevitable thermodynamic breakdown occurs. With state of the art Nb based cavity design fast approaching these theoretical limits, novel material innovations must be sought in order to realize next generation SRF cavities. One proposed method to improve SRF performance is to utilize thin film superconducting-insulating-superconducting (SIS) multilayer structures to effectively magnetically screen a bulk superconducting layer such that it can operate at higher field gradients before suffering critically detrimental SRF losses. This dissertation focuses on the production and characterization of thin film superconductors for such SIS layers for radio frequency applications. Correlated studies on structure, surface morphology and superconducting properties of epitaxial Nb and MgB2 thin films are presented.

Beringer, Douglas↗

Nb-on-Cu Cavities for 700-1500 MHZ SRF Accelerators

Single crystal films of Nb were grown on MGO; RRR≈570 was measured in ≈4 µm films of Nb; cross-section SEM images showed that macro-particles embedded in the film had the same (100) crystal structure as the bulk film and were well adhered, hence did not pose a problem for vortex penetration. We coated 1.3 GHz cavities inside our vacuum chamber. We showed that we could grow uniform films on such cavities, but the best Qo measured was ~2E8, not acceptable. Next we coated 1.3 GHz cavities when pumping directly on the cavity. Arguing that heaters inside the vacuum chamber might be contaminating the coating, we pumped directly on the cavity so that it could be heated from outside (in air). The best Qo measured was ≈1E9, a record for all our cavity deposition. However, this encouraging result was tempered by Q-slope, which we attributed to impurities in the film due to the dirty (non-clean room) environment at AASC. It was decided to install the CED apparatus at JLab, to assemble, clean and coat under cleaner conditions. We next coated 1.3 GHz cavity at JLab. After shipping and installing the CED apparatus at JLab, two coating runs were completed before the project ended. Due to arcs inside the vacuum (faulty current leads) the runs ended prematurely, with ≈0.7 µm films. Since we had learned from coupon work that film thickness >2 µm (preferably 4 µm) were essential for good RF performance, the negative results were understandable. Indeed, the quadrupole resonator coatings for Sarah Aull at CERN had also indicated that a 2 µm coating would show adequate RF quality for LHC upgrades and for the ILC. JLab now has acquired the apparatus and knowledge of its operation. It is hoped that JLab will continue this potentially rewarding development and soon show the results that have eluded us.

43 PARTICLE ACCELERATORS↗

Final Geometry and Dimensions of UCG Field Test Cavities

This report documents parameters of underground coal gasification (UCG) field tests, coal seam geometries, and final documented dimensions of gasified coal cavities. Most of the analysis focused on Hanna, Hoe Creek, and Rocky Mountain. Other field tests are included, although thorough documentation was not done. Data and images are taken from multiple sources including field test reports, conference proceedings, presentations, and discussions. Time was restricted so not all data was included or researched. With time restricting, the main parameters of focus include maximum cavity length, maximum cavity width, coal zone height, maximum coal cavity height, oxidant at the end of the test, and shoebox dimensions (box width, length, and height dimensions such that the volume is approximately equal to that of the gasified cavity estimated from field test diagrams). The next important set of parameters include module type, well spacing, volume of consumed coal, volume of collapsed overburden, maximum cavity height, and duration of the test. The information of this report is meant to reflect on the final coal cavity geometries after days of forward gasification. In some cases, intermediate phases were not analyzed, especially if they consumed the same coal seam as later test phases.

01 COAL, LIGNITE, AND PEAT↗

Muon Capture, Phase Rotation, and Cooling in Pressurized RF Cavities

Gas-filled rf cavities can provide high-gradient accelerating fields for muons and can be used for simultaneous acceleration and cooling of muons. In this paper we explore using these cavities in the front-end of the capture and cooling systems for neutrino factories and muon colliders. We consider using gas-filled rf cavities for the initial front-end cooling systems. We also consider using them for simultaneous phase-energy rotation and cooling in a front-end system. We also consider using lower-density rf cavities, where the gas density is primarily for rf breakdown suppression, with less cooling effect. Pressurized rf cavities enable higher gradient rf within magnetic fields than is possible with evacuated cavities, enabling more options in the front-end. The status of designs of the capture, phase rotation, and precooling systems of muon beams in pressurized cavities is described

43 PARTICLE ACCELERATORS↗

Machine Learning Based Cavity Fault Classification and Prediction

We report on the development of machine learning models for classifying C100 superconducting radio frequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. CEBAF is a continuous-wave recirculating linac utilizing 418 SRF cavities to accelerate electrons up to 12 GeV through 5-passes. Of these, 96 cavities (12 cryomodules) are designed with a digital low-level RF system configured such that a cavity fault triggers waveform recordings of 17 RF signals for each of the eight cavities in the cryomodule. Subject matter experts (SME) can analyze the collected time-series data, identify which of the eight cavities faulted first, and classify the type of fault. This information is used to find trends and strategically deploy mitigations to problematic cryomodules. However, manually labeling the data is laborious and time-consuming. By leveraging machine learning, near real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type has been implemented. We discuss the performance of the ML models during a recent physics run.

43 PARTICLE ACCELERATORS↗

Cavity Production and Testing of the First C75 Cryomodule for CEBAF

The CEBAF cryomodule rework program was updated over the last few years to increase the energy gain of refurbished cryomodules to 75 MeV. The concept recycles the waveguide end-groups from original CEBAF cavities fabricated in the 1990s and replaces the five elliptical cells in each with a new optimized cell shape fabricated from large-grain, ingot Nb material. Eight cavities were fabricated at Research Instruments, Germany, and two cavities were built at Jefferson Lab. Each cavity was processed by electropolishing and tested at 2.07 K. The best eight cavities were assembled into ’cavity pairs’ and re-tested at 2.07 K, before assembly into the cryomodule. All but one cavity in the cryomodule were within 10% of the target accelerating gradient of 19 MV/m with a quality factor of 8·10⁹. The performance limitations were field emission and multipacting.

Ciovati, G.↗

SRF Cavity Fault Classification Using Machine Learning At CEBAF

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is the first large high power CW recirculating electron accelerator to make use of SRF accelerating structures. The structures are configured in two anti-parallel linacs connected by arcs. Each linac consists of twenty C20/C50 cryomodules each containing eight 5-cell cavities and five C100 upgrade cryomodules each containing eight 7-cell cavities. Accurately classifying the source of cavity faults is critical for improving accelerator performance. A cavity fault triggers a waveform acquisition process where 17 waveform records sampled at 5 kHz are recorded for each of the 8 cavities in the affected cryomodule. The waveform record length is sufficiently long for transient microphonic effects to be observable. This data combined with archived signals sampled at 10 Hz are used to classify faults. Significant time is required for a subject matter expert to analyze and identify the intra-cavity signatures of imminent faults. This paper describes a path forward that utilizes machine learning for automatic fault classification. Post-training identification of the physical origins of faults are discussed, as are potential machine-trained model-free implementations of trip avoidance procedures. These methods should provide new insights into cavity fault mechanisms and facilitate intelligent optimization of cryomodule performance

Solopova, A.↗

Laboratory measurements of shock propagation through spherical cavities in an optically accessible polymer

Surrogate laboratory experiments were conducted to understand how cavities surrounding an explosive event in a bounded material influence the transfer of energy to the surface of the material. Exploding bridgewires were detonated in a cavity that had been created in an optically accessible polymer material. The shock propagation was investigated through five paths, three through spherical cavities of varying size filled with air, one without a cavity and one in air. Shock propagation was imaged using the schlieren technique. The path effects were determined by measuring energy at the polymer surface using a pressure sensor. All cavities were successful at reducing the peak pressure nearly 100% from the case without a cavity, a reduction close to air. The degree of reduction was not uniform over all frequencies. Overall, our findings suggest that cavities influence both the amount and frequency content of the energy transfer from source to surface.

36 MATERIALS SCIENCE↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105. This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of Cathode and Cavity Geometries in Electropolishing (EP): Electric Field Simulation

Niobium (Nb) superconducting radio frequency (SRF) cavities require electropolishing surface treatment to reach high acceleration gradient. EP performed in the plateau region of an I-V curve [1] leads to a smooth finish of the cavity surface including the equator surface. The equator surface is vital because a rough equator surface leads to premature quench and limit the cavity performance. Previous experimental work was performed to optimize EP parameters for low-beta (LB) 650 MHz Nb cavity [1]. It was found that different cathode surface areas vary the plateau onset voltage. A lower onset voltage was achieved for HB650 cavity with an enlarged cathode surface area. The aim of the study is to perform electrostatic and electrochemical simulation to understand the impact of both cavity geometry and cathodes. This report covers an initial result on electric field simulation performed with HB and LB 650 MHz cavities.

Loer, Bereket↗

Nb SRF cavities applied to searches for beyond the standard model physics

The SRF technology developed for accelerators can be successfully applied to new applications, including quantum computing, dark matter searches and beyond the standard model physics. The ultra-high quality factor of SRF cavities can al-low to achieve unprecedented sensitivity in fields outside of the usual accelerator applications, for examples fundamental and beyond the standard model physics. Applications of SRF cavities for gravitational waves searches are also being investigated. The SQMS Physics and Sensing thrust is working on this effort as it strives to combine SRF cavities with QIS, with a focus on BSM and fundamental physics. Using Nb SRF cavities, we run a proof of principle search for the dark photon dark matter candidate at fixed frequency demonstrating the deepest sensitivity to wavelike dark mater [1]. The Dark SRF experiment uses two 1.3GHz SRF cavities to conduct a light shining through wall (LSW) experiment to attempt producing and detecting dark photons in the laboratory. The results of this first superconducting LSW search were recently published [2] and we are now working on the second phase of the experiment, which will be run in a dilution refrigerator using 2.6GHz SRF cavities. In addition to the limits we have achieved, we will also present the experiments we are currently developing, such as the heterodyne axion DM search [3, 4], the SERAPH series of experiments, and gravitational waves searches based on SRF cavities as proposed in [5-8].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a Prototype Superconducting Radio-Frequency Cavity for Conduction-Cooled Accelerators

Recent progress in the development of high-quality Nb?Sn film coatings along with the availability of cryocoolers with high cooling capacity at 4 K makes it feasible to operate SRF cavities cooled by thermal conduction at relevant accelerating gradients for use in accelerators. We have developed a prototype single-cell cavity to prove the feasibility of operation up to the accelerating gradient required for 1 MeV energy gain, cooled by conduction with cryocoolers. The cavity has a ~3 ¿m thick Nb?Sn film on the inner surface, deposited on a ~4 mm thick bulk Nb substrate and a bulk ~7 mm thick Cu outer shell with three Cu attachment tabs. The cavity was tested up to a peak surface magnetic field of 53 mT in liquid He at 4.3 K. A horizontal test cryostat was designed and built to test the cavity cooled with three cryocoolers. The rf tests of the conduction-cooled cavity achieved a peak surface magnetic field of 50 mT and stable operation was possible with up to 18.5 W of rf heat load. The peak frequency shift due to microphonics was 23 Hz. These results represent the highest peak surface magnetic field achieved in a conduction-cooled SRF cavity to date

Ciovati, Gianluigi↗

SRF Cavity Instability Detection with Machine Learning at CEBAF

During the operation of CEBAF, one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. Identifying an unstable cavity out of the hundreds of cavities installed at CEBAF is difficult and time-consuming. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detect fast transient instabilities. A fast data acquisition system for the legacy SRF cavities is being developed which samples and reports at 5 kHz to allow for detection of transients. A prototype chassis has been installed and tested in CEBAF. An autoencoder based machine learning model is being developed to identify anomalous SRF cavity behavior. The model is presently being trained on the slow (1 Hz) data that is currently available, and a separate model will be developed and trained using the fast (5 kHz) DAQ data once it becomes available. This paper will discuss the present status of the new fast data acquisition system and results of testing the prototype chassis. This paper will also detail the initial performance metrics of the autoencoder model.

Carpenter, A.↗

MAGNETIC FLUX EXPULSION IN SUPERCONDUCTING RADIO-FREQUENCY NIOBIUM CAVITIES MADE FROM COLD WORKED NIOBIUM

Trapped residual magnetic field during the cool down of superconducting radio frequency (SRF) cavities is one of the primary sources of RF residual losses leading to lower quality factor. Historically, SRF cavities have been fabricated from high purity fine grain niobium with grain size ~50 to 100 µm as well as large grain with grain size of the order of few centimeters. Non-uniform recrystallization of fine-grain Nb cavities after the post fabrication heat treatment leads to higher flux trapping during the cool down, and hence the lower quality factor. We fabricated two 1.3 GHz single cell cavities from cold-worked niobium from different vendors and processed along with cavities made from SRF grade Nb. The flux expulsion and flux trapping sensitivity were measured after successive heat treatments in the range 800 to 1000°C. The flux expulsion from cold-worked fine-grain Nb cavities improves after 800°C/3h heat treatments and it becomes similar to that of standard fine-grain Nb cavities when the heat treatment temperature is higher than 900°C.

Khanal, B. D.↗

SRF Cavity Instability Detection with Machine Learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detect fast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. A Principal Component Analysis (PCA) approach is being developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and PCA model, along with initial performance metrics. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Carpenter, A.↗