Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Automatic and rapid calibration of urban building energy models by learning from energy performance database

Urban building energy modeling (UBEM) is attracting increasing attention in the energy modeling filed. Unlike modeling a single building using detailed building systems information, UBEM generally uses limited high-level building stock data to infer default assumptions about building characteristics and operations. Additionally, this practice inherently brings uncertainty to UBEM. This study introduced a novel method of automatic and rapid calibration of UBEM based on the annual electricity and natural gas energy use data by learning the correlations between crucial model input parameters and the building energy use from the reference building models. A case study was presented to calibrate 72 large office buildings built before 1978 in San Francisco. Seventeen model parameters were selected and Monte Carlo sampling was used to create 1000 samples that reasonably represent the parameter space. Then 1000 simulations were performed for the reference building model to create an energy performance database. The results showed that by learning from the energy performance database, it took less than four simulation runs on average to calibrate a building model. After the calibration, the distributions of each parameter were obtained to replace their single predefined default values. For example, the default lighting power density of 21.39 W/m 2 was calibrated to be 7.50 W/m 2 on average. The case study successfully demonstrated the effectiveness of the novel calibration method for UBEM in the mild climate. The method will be further tested in future for other climate zones and other building types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transition in ICF Capsule Implosions

Longstanding design and reproducibility challenges in inertial confinement fusion (ICF) capsule implosion experiments involve recognizing the need for appropriately characterized and modeled three-dimensional initial conditions and high-fidelity simulation capabilities to predict transitional flow approaching turbulence, material mixing characteristics, and late-time quantities of interest—e.g., fusion yield. We build on previous coarse graining simulations of the indirect-drive national ignition facility (NIF) cryogenic capsule N170601 experiment-a precursor of N221205 which resulted in net energy gain. We apply effectively combined initialization aspects and multiphysics coupling in conjunction with newly available hydrodynamics simulation methods, including directional unsplit algorithms and low Mach-number correction-key advances enabling high fidelity coarse grained simulations of radiation-hydrodynamics driven transition. Our presentation includes discussion of the capsule initialization and implosion dynamics, analysis of the vorticity production budget, transition signatures, quantities of interest—late-time ion temperature and fusion-neutron yield, numerical uncertainty quantification, and comparisons with NIF data.

42 ENGINEERING↗

Avista CEF2 Shared Energy Economy: Modeling and Simulation

This research project supported Avista’s Shared Energy Economy (SEE) Project in Spokane’s University District (UDistrict), as funded by the WA Department of Commerce Clean Energy Fund (CEF) Phase 2. The SEE project comprises a microgrid with two campus buildings, two solar photovoltaic generators, and two batteries. The microgrid can operate grid-connected or off-grid. This research project included modeling the buildings and other microgrid components, simulating a transactive energy system, and supporting Avista’s testing of different use cases for the WA Department of Commerce. The main research finding is that buildings can be modeled successfully in a data-driven approach.

14 SOLAR ENERGY↗

Incorporating two-dimensional conduction modeling techniques into an energy simulation program: The EnergyPlus radiant system example

Due to the inherent complexity of multi-dimensional solutions for transient conduction in a multilayered building element, most heat balance-based algorithms assume that conduction occurs only in one dimension—through the building element between the inside and outside environments. Usually, since the length and width of the elements are much greater than the thickness of the element, this is a valid assumption. However, there are some cases such as hydronic radiant slabs where this assumption may not lead to an accurate estimate of the energy consumption of the system. In a hydronic radiant slab, water tubes are embedded in a slab, and hot or chilled water is circulated to meet any heating or cooling loads. The energy consumption of such a system will depend highly on the temperature of the water being sent to the slab (i.e., produced by the boiler or chiller). The temperature of the water that must be sent to the slab will depend on the spacing of the tubes, the multilayer construction of the building element, and the boundary conditions to which the construction is exposed. Thus, to accurately predict the energy consumption of such a system, a transient two-dimensional heat conduction model must be integrated with a heat balance-based simulation. This paper demonstrates the potential loss of accuracy associated with the one-dimensional radiant system models by providing a comparison of one- and two-dimensional solutions using EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

iMaNGA: mock MaNGA galaxies based on IllustrisTNG and MaStar SSPs – II. The catalogue

ABSTRACT Strengthening the synergy between simulations and observations is essential to test galaxy formation and evolution theories. To achieve this goal, in the first paper of this series, we presented a method to generate mock SDSS-IV/Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) integral-field spectroscopic galaxy observations from cosmological simulations. In this second paper, we build the iMaNGA catalogue consisting of ∼1000 unique galaxies from the TNG50 cosmological simulations, selected to mimic the SDSS-IV/MaNGA-Primary sample selection. Here, we present and discuss the iMaNGA sample and its comparison to the MaNGA Primary catalogue. The iMaNGA sample well recovers the MaNGA-Primary sample in terms of stellar mass versus angular size relation and spatial resolution. The Sérsic index versus angular size relation, instead, is not reproduced well by the simulations, mostly because of a paucity of high-mass elliptical galaxies in TNG50. We also investigate our ability to recover the galaxy kinematics and stellar population properties with full-spectral fitting. We demonstrate that ‘intrinsic’ and ‘recovered’ stellar kinematics, stellar ages, and metallicities are consistent, with residuals compatible with zero within 1σ. Also ‘intrinsic’ and ‘recovered’ star formation histories display a great resemblance. We conclude that our mock generation and spectral fitting processes do not distort the ‘intrinsic’ galaxy properties. Therefore, in the third paper of this series, we can meaningfully test the cosmological simulations, comparing the stellar population properties and kinematics of the iMaNGA mock galaxies and the MaNGA observational results.

79 ASTRONOMY AND ASTROPHYSICS↗

End-Use Load Profiles for the U.S. Building Stock: Methodology and Results of Model Calibration, Validation, and Uncertainty Quantification

The United States is embarking on an ambitious transition to a 100% clean energy economy by 2050, which will require improving the flexibility of electric grids. One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High- quality end-use load profiles (EULPs) provide this information, and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation (Frick, Eckman, and Goldman 2017; Frick 2019). To help fill this gap, the U.S. Department of Energy (DOE) funded a three-year project - End-Use Load Profiles for the U.S. Building Stock - that culminated in the release of a publicly available dataset1 of simulated EULPs representing residential and commercial buildings across the contiguous United States. The motivation for this work is further detailed in a November 2019 report: Market Needs, Use Cases, and Data Gaps (Mims Frick et al. 2019). This Methodology and Results report provides detailed descriptions of how the dataset was developed, intended for an audience of dataset and model users interested in the technical details. These details include descriptions of all of the model improvements made for calibration and the final comparisons to empirical data sources. A companion report, End-Use Load Profiles for the U.S. Building Stock: Applications and Opportunities, will be published subsequently and will describe example applications and considerations for using the dataset, intended for an audience of general dataset users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]↗

Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatiotemporal parallelization of an analytical heat conduction model for additive manufacturing via a hybrid OpenMP + MPI approach

The ability to do thermal simulations for entire additive manufacturing builds is a key computational problem facing the additive manufacturing community; however, complex numerical models considering multiple physical phenomena currently do not have the capacity for simulations at this scale. To this end, conduction only analytic models offer a viable approach due to the massive drop in computational expense. In this work, we extend an existing implementation which uses a governing equation which can be evaluated at any point in space and time. This implementation already utilizes OpenMP with a spatial decompositions scheme stemming from a melt pool tracking algorithm. Furthermore, we then combine this with a parallel in time (PinT) approach to make the problem highly parallelizable. The new scheme, which uses MPI for internode communication and OpenMP for intranode communication, is shown to scale very well across multiple computational nodes. This approach results in the ability to simulate the 3D solidification conditions for entire layers of additively manufactured parts in minutes making part scale thermal simulations more practical.

36 MATERIALS SCIENCE↗

A Scoping Study to Develop a Computational Fluid Dynamics Based Model to Predict Radiological Materials Packaging Temperatures within a Generic Staging Building

The objective of this work is to perform computational fluid dynamics simulations of a ventilated radiological-material-package staging building to determine the effect of including or excluding a variety of physical effects and computational methods on both the predicted package temperatures and required computational resources. The generic building contains 640 drum-packages containing heat-generating, radiological material supported on four racks that are eight levels tall. Additionally, there is a forced ventilation system, lighting, and insulated walls. Computational models were constructed that included or excluded (a) shelving, (b) effects of unsteadiness, and (c) radiation heat transfer. Simulations with each drum modeled separately were compared to simpler simulations with sets of four drums represented by an equivalent box-package. These models employed between 106 to 107 elements. Steady state simulations predicted package temperatures that were within 0.1°C of simulations that included transient effects and required only one-eighth the computational resources. Calculations that excluded shelving predicted temperatures within 0.6°C of simulations that included shelving and required one-fourth the computational resources. Excluding radiation heat transfer systematically increased temperatures by around 1.5°C but reduced computational resources by a factor of four. The box-package model reduced the computational resources by a factor of 3, but systematically predicted higher temperatures by around 1.1°C. These results will be used to develop an efficient computational fluid dynamics model to assess the ability of different staging building designs to prevent the temperature of package components from exceeding specified limits.

42 ENGINEERING↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Influence of building heat distribution temperatures on the energy performance and sizing of 5th generation district heating and cooling networks

This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Urban Representation on Simulation of Hurricane Rainfall

Abstract Taking the examples of Hurricane Florence (2018) over the Carolinas and Hurricane Harvey (2017) over the Texas Gulf Coast, the study attempts to understand the performance of slab, single‐layer Urban Canopy Model (UCM), and Building Environment Parameterization (BEP) in simulating hurricane rainfall using the Weather Research and Forecasting (WRF) model. The WRF model simulations showed that for an intense, large‐scale event such as a hurricane, the model quantitative precipitation forecast over the urban domain was sensitive to the model urban physics. The spatial and temporal verification using the modified Kling‐Gupta efficiency and Method for Object based Diagnostic and Evaluation in Time Domain suggests that UCM performance is superior to the BEP scheme. Additionally, using the BEP urban physics scheme over UCM for landfalling hurricane rainfall simulations has helped simulate heavy rainfall hotspots.

Geology↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e., 53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Yoon, Yeobeom↗

Assessment of peak power demand reduction available via modulation of building ventilation systems.

Peak power demand strains electrical grids and increases cost of electricity generation, transmission and distribution infrastructure. Many studies have examined ways of reducing peak power demand, including modification of room air temperature setpoints or reduction of lighting levels. However, very few or no studies have examined the peak power reduction resource offered by temporary curtailment of building ventilation systems. For this reason, we conducted a simulation campaign in which we examined the resource offered by temporary ventilation curtailment in commercial buildings of different use types across the United States and in residences in the state of California, with the essential constraint that any changes resulted in air quality acceptable to occupants through additional ventilation to compensate for the curtailment. To do this, we employed previously validated building models implemented in the airflow and contaminant transport tool CONTAM and building thermal and systems modeling tool EnergyPlus, in some cases co-simulated. Overall, results show savings are highly dependent on building type and climate but range from 0–2 W/ft 2 and up to 40% of total peak building power demand. Depending on building type, this power shed can be conducted for 1.5–8 h before acute exposure or odor concerns are expected, assuming a safety factor of 2. This reduction is of the same magnitude as that offered by thermal control strategies such as setpoint increase, or from lighting reduction strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the Energy Resilience of Office Buildings: Development and Testing of a Simplified Metric for Real Estate Stakeholders

Increasing concern over higher frequency extreme weather events is driving a push towards a more resilient built environment. In recent years there has been growing interest in understanding how to evaluate, measure, and improve building energy resilience, i.e., the ability of a building to provide energy-related services in the event of a local or regional power outage. In addition to human health and safety, many stakeholders are keenly interested in the ability of a building to allow continuity of operations and minimize business disruption. Office buildings are subject to significant economic losses when building operations are disrupted due to a power outage. We propose “occupant hours lost” (OHL) as a means to measure the business productivity lost as the result of a power outage in office buildings. OHL is determined based on indoor conditions in each space for each hour during a power outage, and then aggregated spatially and temporally to determine the whole building OHL. We used quasi-Monte Carlo parametric energy simulations to demonstrate how the OHL metric varies due to different building characteristics across different climate zones and seasons. The simulation dataset was then used to develop simple regression models for assessing the impact of ten key building characteristics on OHL. The most impactful were window-to-wall ratio and window characteristics. The regression models show promise as a simple means to assess and screen for resilience using basic building characteristics, especially for non-critical facilities where it may not be viable to conduct detailed engineering analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

JHTDB-wind: a web-accessible large-eddy simulation database of a wind farm with virtual sensor querying

This paper introduces JHTDB-wind (https://turbulence.idies.jhu.edu/datasets/windfarms, last access: 11 November 2025), a publicly accessible database containing large-eddy simulation (LES) data from wind farms. Building on the framework of the Johns Hopkins Turbulence Database (JHTDB), which hosts direct numerical simulation (DNS) and some LES datasets of canonical turbulent flows, JHTDB-wind stores the 4D space–time history of the flow and provides users the ability to access and query the data via a web-based virtual sensor interface. The initial dataset comprises LES results from a large wind farm with 10×6 turbines, modeled using a filtered actuator line method, under conventionally neutral atmospheric conditions. These data comprise 1 h (hour) of flow field data (velocity, pressure, potential temperature deviation, subgrid-scale (SGS) eddy viscosity, and turbine forces, approximately 15 TB (terabytes) and wind turbine data – including both turbine-level operational quantities and blade-level aerodynamic quantities (approximately 1.3 TB) – stored in Zarr and Parquet formats, respectively. Data retrieval is facilitated by the giverny Python package, allowing remote users to query the database in Python or MATLAB (C and Fortran support are available for flow field data). This paper details the simulation setup and demonstrates data access through examples that analyze wind farm flow structures and turbine performance. The framework is extensible to future datasets, including the JHTDB-wind diurnal cycle simulation analyzed in Xiao et al. (2025).

17 WIND ENERGY↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗