Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bolometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Comparison of photoexcited p-InAs THz radiation source with conventional thermal radiation sources

P-type InAs excited by ultrashort optical pulses has been shown to be a strong emitter of terahertz radiation. In a direct comparison between a p-InAs emitter and conventional thermal radiation sources, we demonstrate that under typical excitation conditions p-InAs produces more radiation below 1.2 THz than a globar. By treating the globar as a blackbody emitter we calibrate a silicon bolometer which is used to determine the power of the p-InAs emitter. The emitted terahertz power was found to be 98{+-}10 nW in this experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wide-field Imaging Survey of Dust Continuum Emissions at lambda = 1.1 mm toward the Chamaeleon and Lupus Regions with AzTEC on ASTE

We carried out an imaging survey of dust continuum emissions toward the Chamaeleon and Lupus regions. Observations were made with the 144-element bolometer array camera AzTEC mounted on the 10-meter sub-millimeter telescope ASTE during 2007-2008. The preliminary results of disk search and the cloud structure of Lupus III are presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Analyzing the Radiation Properties of High-Z Impurities in High-Temperature Plasmas

Most tokamak-based reactor concepts require the use of noble gases to form either a radiative mantle or divertor to reduce conductive heat exhaust to tolerable levels for plasma facing components. Predicting the power loss necessary from impurity radiation is done using electron temperature-dependent 'cooling-curves' derived from ab initio atomic physics models. We present here a technique to verify such modeling using highly radiative, argon infused discharges on Alcator C-Mod. A novel x-ray crystal imaging spectrometer is used to measure spatially resolved profiles of line-emissivity, constraining impurity transport simulations. Experimental data from soft x-ray diodes, bare AXUV diodes and foil bolometers are used to determine the local emissivity in three overlapping spectral bands, which are quantitatively compared to models. Comparison of broadband measurements show agreement between experiment and modeling in the core, but not over the entire profile, with the differences likely due to errors in the assumed radial impurity transport outside of the core. Comparison of Ar{sup 16+} x-ray line emission modeling to measurements suggests an additional problem with the collisional-radiative modeling of that charge state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing and Modeling the Noise and Complex Impedance of Feedhorn-Coupled TES Polarimeters

We present results from modeling the electrothermal performance of feedhorn-coupled transition edge sensor (TES) polarimeters under development for use in cosmic microwave background (CMB) polarization experiments. Each polarimeter couples radiation from a corrugated feedhorn through a planar orthomode transducer, which transmits power from orthogonal polarization modes to two TES bolometers. We model our TES with two- and three-block thermal architectures. We fit the complex impedance data at multiple points in the TES transition. From the fits, we predict the noise spectra. We present comparisons of these predictions to the data for two TESes on a prototype polarimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Neutrinoless Double Beta Decay with the CUORE experiment

CUORE is a next generation experiment aimed at the detection of neutrinoless Double Beta Decay of the nuclide {sup 130}Te. The experiment, which will take place in the Gran Sasso National Laboratory (Italy), will look for this rare decay using the macrobolometric technique with a prospected array of 988 detectors. Each bolometer will be constituted by a 5x5x5 cm{sup 3} TeO{sub 2} crystal, for a total mass of about 200 kg of {sup 130}Te, and will be maintained at a temperature of 10 mK. CUORE will probe the effective mass of the neutrino with a sensitivity of a few tens of meV. If an excess of counts are observed above background at the 2.5 MeV corresponding to the Q-value of the decay, CUORE will answer several questions that are still open in the field of neutrino physics, such as the determination of the particle's Majorana nature and of the absolute mass scale. A prototype for CUORE in Gran Sasso, named CUORICINO, has just closed after five years proving its importance as a stand-alone experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diagnostics for first plasma and development plan on KSTAR

The first plasma with target values of the plasma current and the pulse duration was finally achieved on June 13, 2008 in the Korea Superconducting Tokamak Advanced Research (KSTAR). The diagnostic systems played an important role in achieving successful first plasma operation for the KSTAR tokamak. The employed plasma diagnostic systems for the KSTAR first plasma including the magnetic diagnostics, millimeter-wave interferometer, inspection illuminator, H{sub {alpha}}, visible spectrometer, filterscope, and electron cyclotron emission (ECE) radiometer have provided the main plasma parameters, which are essential for the plasma generation, control, and physics understanding. Improvements to the first diagnostic systems and additional diagnostics including an x-ray imaging crystal spectrometer, reflectometer, ECE radiometer, resistive bolometer, and soft x-ray array are scheduled to be added for the next KSTAR experimental campaign in 2009.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Edelweiss-II Dark Matter Search : Status and first results

EDELWEISS is a direct dark matter search experiment operating in the low radioactivity environment of the Modane Underground Laboratory. The experiment runs at very low temperature massive Ge detectors in order to identify nuclear recoils induced by elastic scattering of WIMPs from the galactic halo. The commissioning of the second phase of the experiment, involving more than 7 kg of Ge detector, has been completed in 2007. These ionization/heat detectors allow an event by event electronic/nuclear recoil discrimination. Preliminary results of a new type of bolometer with interdigitized electrodes for the charge collection with active rejection are presented.

79 ASTRONOMY AND ASTROPHYSICS↗

A new absolute extreme ultraviolet image system designed for studying the radiated power of the Joint Texas Experimental Tokamak discharges

A bolometer imaging system mounted on different toroidal and poloidal locations used for radiation observation has been developed in the Joint Texas Experimental Tokamak (J-TEXT tokamak). Three miniature pinhole AXUV16ELG (16 elements absolute extreme ultraviolet silicon photodiodes) array cameras, which are settled down in the same toroidal position but in three different poloidal places, can provide a broad viewing angle that covers the whole plasma cross-section, and hence can measure the total radiated power and provide the radiated emissive profile, while nine AXUV10EL (10 elements absolute extreme ultraviolet silicon photodiodes) array cameras are divided into three groups and will be mounted on different toroidal locations to observe the toroidal radiated power distribution. Among these detectors, one element of the AXUV16ELG array is absolutely calibrated by the synchrotron radiation source to verify the system reliability. Although there are some discrepancies between the typical responsivity given by IRD Co. and the calibrated results, it is confirmed that the discrepancies have no major effect on the final result after the simulation. The details of the system as well as observations are presented in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of dynamic Hohlraum opacity samples to increase measured sample density on Z

We are attempting to measure the transmission of iron on Z at plasma temperatures and densities relevant to the solar radiation and convection zone boundary. The opacity data published by us to date has been taken at an electron density about a factor of 10 below the 9x10{sup 22}/cm{sup 3} electron density of this boundary. We present results of two-dimensional (2D) simulations of the heating and expansion of an opacity sample driven by the dynamic Hohlraum radiation source on Z. The aim of the simulations is to design foil samples that provide opacity data at increased density. The inputs or source terms for the simulations are spatially and temporally varying radiation temperatures with a Lambertian angular distribution. These temperature profiles were inferred on Z with on-axis time-resolved pinhole cameras, x-ray diodes, and bolometers. A typical sample is 0.3 {mu}m of magnesium and 0.078 {mu}m of iron sandwiched between 10 {mu}m layers of plastic. The 2D LASNEX simulations indicate that to increase the density of the sample one should increase the thickness of the plastic backing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An analytical model for pulse shape and electrothermal stability in two-body transition-edge sensor microcalorimeters

High-resolution superconducting gamma-ray sensors show potential for the more accurate analysis of nuclear material. These devices are part of a larger class of microcalorimeters and bolometers based on transition edge sensors (TESs) that have two distinct thermal bodies. We derive the time domain behavior of the current and temperature for compound TES devices in the small signal limit and demonstrate the utility of these equations for device design and characterization. In particular, we use the model to fit pulses from our gamma-ray microcalorimeters and demonstrate how critical damping and electrothermal stability can be predicted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heteroepitaxy of Nd{sub 0.67}Sr{sub 0.33}MnO{sub 3} on silicon for bolometric x-ray detector application

We have recently reported the design concept and sensor fabrication for a novel bolometric x-ray detector based on a rare earth manganite material for application as a total energy monitor for the Linac Coherent Light Source (LCLS) free electron laser at the Stanford Linear Accelerator Center (SLAC). The detector employs epitaxial thin films of Nd{sub 0.67}Sr{sub 0.33}MnO{sub 3} grown on Si by pulsed laser deposition. In this paper we report details of the fabrication of the actual detector, its response characteristics under photon illumination from LCLS, and improvements in the growth scheme of the sensor material on Si using a buffer/template layer scheme that employs yttria-stabilized zirconia, cerium oxide (CeO{sub 2}), and bismuth titanate (Bi{sub 4}Ti{sub 3}O{sub 12}). The thermal sensor response changes linearly with the energy of an optical calibration laser as expected, and the signals from optical and x-ray pulses at LCLS are very similar, thereby validating the design concept. To the best of our knowledge, the LCLS detector application reported here is the first practical use of colossal magnetoresistive manganite bolometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carbon-doped single-crystalline SiGe/Si thermistor with high temperature coefficient of resistance and low noise level

SiGe (C)/Si(C) multiquantum wells have been studied as a thermistor material for future bolometers. A thermistor material for uncooled Si-based thermal detectors with thermal coefficient of resistance of 4.5%/K for 100x100 {mu}m{sup 2} pixel sizes and low noise constant (K{sub 1/f}) value of 4.4x10{sup -15} is presented. The outstanding performance of the devices is due to Ni-silicide contacts, smooth interfaces, and high quality multiquantum wells containing high Ge content.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multimode terahertz-wave generation using coherent Cherenkov radiation

Multimode terahertz(THz)-wave generation using coherent Cherenkov radiation (CCR) was investigated. The frequency spectra of CCR, which utilized a metal-wrapped hollow dielectric tube of 7 mm outer radius and a picosecond electron bunch of 27 MeV beam energy, were measured by a Michelson interferometer with a 4.2 K silicon bolometer. In this study, discrete spectral components at frequencies of 0.09, 0.14, and 0.36 THz were observed experimentally and explained as transverse magnetic (TM) modes of TM{sub 03}, TM{sub 04}, and TM{sub 09}, respectively, according to a theoretical calculation for the tube.

43 PARTICLE ACCELERATORS↗

New generation of double beta decay experiments: are there any limitations?

New generation of experiments to search for neutrinoless double beta decay with sensitivity to effective Majorana neutrino mass on the level of {approx}3-5 meV is discussed. Possible restrictions in achievement of this sensitivity such as: possibility to produce large amount of enriched isotopes, possibility to reach of a very low level of background, energy resolution and possible cost of experiments are considered. It is shown that for realization of so ambitious project 10 tons (or more) of enriched isotope is required. Background index should be on the level {<=}10{sup -5}-10{sup -6} c/kg{center_dot}keV{center_dot}y. In addition, the energy resolution of the detector should be no worse than 1-2%. It is shown that {sup 130}TeO{sub 2} low temperature bolometer could be the most realistic candidate for such an experiment. Under certain conditions experiments with {sup 76}Ge, {sup 100}Mo and {sup 136}Xe can be realized too.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and fabrication of a multi-purpose soft x-ray array diagnostic system for KSTAR

A multi-purpose soft x-ray array diagnostic system was developed for measuring two-dimensional x-ray emissivity profile, electron temperature, Ar impurity transport, and total radiation power. A remotely controlled filter wheel was designed with three different choices of filters. The electron temperature profile can be determined from the ratio of two channels having different thickness of Be layer, and the Ar impurity concentration transport can be determined from a pair of Ar Ross filters (CaF{sub 2} and NaCl thin films). Without any filters, this diagnostic system can also be used as a bolometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and modeling of muon-induced neutrons in LSM in application for direct dark matter searches

Due to a very low event rate expected in direct dark matter search experiments, a good understanding of every background component is crucial. Muon-induced neutrons constitute a prominent background, since neutrons lead to nuclear recoils and thus can mimic a potential dark matter signal. EDELWEISS is a Ge-bolometer experiment searching for WIMP dark matter. It is located in the Laboratoire Souterrain de Modane (LSM, France). We have measured muon-induced neutrons by means of a neutron counter based on Gd-loaded liquid scintillator. Studies of muon-induced neutrons are presented and include development of the appropriate MC model based on Geant4 and analysis of a 1000-days measurement campaign in LSM. We find a good agreement between measured rates of muon-induced neutrons and those predicted by the developed model with full event topology. The impact of the neutron background on current EDELWEISS data-taking as well as for next generation experiments such as EURECA is briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband sample holder for microwave spectroscopy of superconducting qubits

We present a practical design and implementation of a broadband sample holder suitable for microwave experiments with superconducting integrated circuits at millikelvin temperatures. Proposed design can be easily integrated in standard dilution cryostats, has flat pass band response in a frequency range from 0 to 32 GHz, allowing the RF testing of the samples with substrate size up to 4 × 4 mm{sup 2}. The parasitic higher modes interference in the holder structure is analyzed and prevented via design considerations. The developed setup can be used for characterization of superconducting parametric amplifiers, bolometers, and qubits. We tested the designed sample holder by characterizing of a superconducting flux qubit at 20 mK temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-color detector: Mercury-cadmium-telluride as a terahertz and infrared detector

In this paper, issues associated with the development of infrared (IR) and terahertz (THz) radiation detectors based on HgCdTe are discussed. Two-color un-cooled and cooled to 78 K narrow-gap mercury-cadmium-telluride semiconductor thin layers with antennas were considered both as sub-THz (sub-THz) direct detection bolometers and 3–10 μm IR photoconductors. The noise equivalent power (NEP) for one of the detectors studied at ν ≈ 140 GHz reaches NEP{sub 300 K} ≈ 4.5 × 10{sup −10} W/Hz{sup 1/2} and NEP{sub 78 K} ≈ 5 × 10{sup −9} W/Hz{sup 1/2}. The same detector used as an IR photoconductor showed the responsivity at temperatures T = 78 K and 300 K with signal-to-noise ratio S/N ≈ 750 and 50, respectively, under illumination by using IR monochromator and globar as a thermal source.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗