Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Blind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Dark Matter searches with photons at the LHC

We unveil blind spot regions in dark matter (DM) direct detection (DMDD), for weakly interacting massive particles with a mass around a few hundred GeV that may reveal interesting photon signals at the LHC. We explore a scenario where the DM primarily originates from the singlet sector within the Z 3 -symmetric Next-to-Minimal Supersymmetric Standard Model (NMSSM). A novel DMDD spin-independent blind spot condition is revealed for singlino-dominated DM, in cases where the mass parameters of the higgsino and the singlino-dominated lightest supersymmetric particle (LSP) exhibit opposite relative signs (i.e., κ < 0), emphasizing the role of nearby bino and higgsino-like states in tempering the singlino-dominated LSP. Additionally, proximate bino and/or higgsino states can act as co-annihilation partner(s) for singlino-dominated DM, ensuring agreement with the observed relic abundance of DM. Remarkably, in scenarios involving singlino-higgsino co-annihilation, higgsino-like neutralinos can distinctly favor radiative decay modes into the singlino-dominated LSP and a photon, as opposed to decays into leptons/hadrons. In exploring this region of parameter space within the singlino-higgsino compressed scenario, we study the signal associated with at least one relatively soft photon alongside a lepton, accompanied by substantial missing transverse energy (E T ) and a hard initial state radiation jet at the LHC. In the context of singlino-bino co-annihilation, the bino state, as the next-to-LSP, exhibits significant radiative decay into a soft photon and the LSP, enabling the possible exploration at the LHC through the triggering of this soft photon alongside large E T and relatively hard leptons/jets resulting from the decay of heavier higgsino-like states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of navigator-gated and breath-held image acquisition techniques for multi-echo quantitative dixon imaging of the liver in children and young adults

Purpose: Acquired over a breath hold, multi-echo Dixon (mDixon) magnetic resonance imaging (MRI) of the liver can be used to quantify proton density fat fraction (PDFF) and iron-related signal decay. However, young, obese, and co-morbid patients may have limited breath holding capacity and could benefit from a motion-robust mDixon acquisition. The purpose of this study was to compare hepatic PDFF and R2* values between navigator-gated and breath-held mDixon MRI acquisition techniques in children and young adults with suspected liver disease. Materials and methods: This retrospective study was institutional review board-approved with a waiver of informed consent. Patients who underwent liver MRI with breath-held and navigator-gated mDixon sequences between January 2017 and July 2018 were included. One reviewer, blinded to sequence, measured PDFF and R2* on four images from each sequence. Another blinded reviewer graded respiratory motion (5-point Likert scale). Pearson correlation (r), Lin’s concordance coefficients (r{sub c}), and Bland–Altman analyses were used to assess agreement between techniques. Frequency of clinically limiting motion (score ≥ 3) was compared with Fisher’s exact test. Results: Forty-two patients were included (15 female, 27 male; mean age: 15.7 ± 4.6 years). Mean PDFF and R2* were 16.6 ± 13.1% and 29.3 ± 4.7 s{sup −1} (breath-held) versus 17.0 ± 13.2% and 29.6 ± 5.2 s{sup −1} (navigator-gated). PDFF agreed almost perfectly between sequences (r{sub c} = 0.997, 95% CI 0.994–0.998; mean bias: 0.3%; 95% limits of agreement: − 2.4 to +1.7%), while R2* values correlated very strongly but with poor agreement (r = 0.837, r{sub c} = 0.832, 95% CI 0.716–0.910). Navigator-gated images exhibited significantly higher frequency of clinically limiting respiratory motion (88% vs. 48%, p = 0.0001). Conclusion: Despite greater respiratory motion artifact, a free-breathing navigator-gated mDixon sequence produces PDFF values with almost perfect agreement to a breath-held sequence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Can MRI be used to diagnose histologic grade in T1a (< 4 cm) clear cell renal cell carcinomas?

Objective: To assess whether MRI can differentiate low-grade from high-grade T1a cc-RCC. Materials and methods: With IRB approval, 49 consecutive solid < 4 cm cc-RCC (low grade [Grade 1 or 2] N = 38, high grade [Grade 3] N = 11) with pre-operative MRI before nephrectomy were identified between 2013 and 2018. Tumor size, apparent diffusion coefficient (ADC) histogram analysis, enhancement wash-in and wash-out rates, and chemical shift signal intensity index (SI index) were assessed by a blinded radiologist. Subjectively, two blinded Radiologists also assessed for (1) microscopic fat, (2) homogeneity (5-point Likert scale), and (3) ADC signal (relative to renal cortex); discrepancies were resolved by consensus. Outcomes were studied using Chi square, multivariate analysis, logistic regression modeling, and ROC. Inter-observer agreement was assessed using Cohen’s kappa. Results: Tumor size was 24 ± 7 (13–39) mm with no association to grade (p = 0.45). Among quantitative features studied, corticomedullary phase wash-in index (p = 0.015), SI index (p = 0.137), and tenth-centile ADC (p = 0.049) were higher in low-grade tumors. 36.8% (14/38) low-grade tumors versus zero high-grade tumors demonstrated microscopic fat (p = 0.015; Kappa = 0.67). Microscopic fat was specific for low-grade disease (100.0% [71.5–100.0]) with low sensitivity (36.8% [21.8–54.6]). Other subjective features did not differ between groups (p > 0.05). A logistic regression model combining microscopic fat + wash-in index + tenth-centile-ADC yielded area under ROC curve 0.98 (Confidence Intervals 0.94–1.0) with sensitivity/specificity 87.5%/100%. Conclusion: The combination of microscopic fat, higher corticomedullary phase wash-in and higher tenth-centile ADC is highly accurate for diagnosis of low-grade disease among T1a clear cell RCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of the Efficacy of the Embolic Agents Acrylamido Polyvinyl Alcohol Microspheres and Tris-Acryl Gelatin Microspheres for Uterine Artery Embolization for Leiomyomas: A Prospective Randomized Controlled Trial

Objective: To evaluate the efficacy of acrylamido polyvinyl alcohol microspheres (a-PVAM) as an embolic agent for uterine artery embolization (UAE) compared with Tris-acryl gelatin microspheres (TAGM).Design, Setting, ParticipantsProspective randomized double-blind noninferiority trial. Conducted at two sites both with regional UAE practices. Forty-six women with symptomatic leiomyomas.InterventionUAE procedure was performed with either of the two embolic agents. Either 700-900-{mu}m a-PVAM or 500-700-{mu}m TAGM was used.Main Outcome MeasuresChanges in leiomyoma perfusion, overall uterine volume, and dominant leiomyomas volume measured by contrast-enhanced magnetic resonance imaging at 1 week, 3 months, and 6 months after UAE by a reader blinded to the embolic agent used. Changes in Uterine Fibroid Symptoms and Quality of Life questionnaire scores were measured at 3, 6, and 12 months after UAE. Results: Forty-six patients were randomized and treated under the study protocol (a-PVAM n = 22, TAGM n = 24). There were no procedure-related complications. Two patients were excluded from analysis (one technical failure of the procedure, one withdrawal from study). Successful (>90%) leiomyoma devascularization was observed in 81% of subjects at 1 week after UAE, 97% at 3 months after UAE, and 95% at 6 months after UAE. No significant differences were observed in 14 of 15 outcome measurements, consistent with noninferiority. TAGM was slightly superior to a-PVAM on one comparison (overall quality of life at 3 months after UAE).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interlaboratory Reproducibility of Contour Method Data in a High Strength Aluminum Alloy

The contour method for residual stress measurement has seen significant development, but an experimental reproducibility study utilizing physical samples has not been published. A double-blind reproducibly study is reported, having scope beginning with EDM cutting and ending with residual stress calculation. A reinforced I-beam sample geometry is identified for its unique residual stress profile when extracted from residual stress bearing quenched aluminum bar (7050-T74). Contour measurements are prescribed on a midplane of symmetry with dimensions 24.0 mm by 50.0 mm. Fourteen identically prepared samples are fabricated from a single long bar with well characterized and uniform residual stress. Five samples throughout the bar are identified for planning measurements to validate sample uniformity and overall suitability of the residual stress field. The planning measurements employ a range of techniques: contour method, neutron diffraction, and hole-drilling. Eight samples are distributed to an international group of participants to execute their standard measurement practice. A double-blind process is followed to provide anonymity. Results are provided by eight participants: six being self-similar and two being quite different, the latter set aside as outliers. An average residual stress field is established from non-outlying results and the spatial distribution of reproducibility standard deviation is determined. The average stress field ranges from -60 to 70 MPa and the reproducibility standard deviation averages 8.1 MPa on the measurement plane. The average reproducibility standard deviation is about 3 × larger for points within 1.0 mm of plane boundaries (17.6 MPa) than for the remaining points (6.1 MPa). Reproducibility standard deviation (among different labs) for contour method residual stress measurement is found to be very similar to repeatability standard deviation (in a single lab) reported in prior work. The reproducibility observed here, for the entire measurement process, is also similar to that found in a prior reproducibility study limited to contour method data analysis.

36 MATERIALS SCIENCE↗

Experimental data for damage mechanics simulation challenge

While there are many computational approaches for simulating damage in rock and other materials, few have been ground truth tested with either known experimental data or with blind data sets. Here, in this work, we present a bench-mark laboratory data set for a damage mechanics challenge to compare computational approaches on damage evolution in brittle-ductile materials. The samples were fabricated through additive manufacturing to produce repeatable specimens designed to fail in controlled ways. The failure was induced in the samples using a 3-point bending test to produce different Modes such as Mode I and mixed Modes including I-II, I-III and I-II-III Modes to generate a calibration data set and a blind challenge data set. Data collected included spatial and temporal measurements from traditional digital load–displacement sensors, 2D digital image correlation measurement to map surface deformations, 3D X-ray microscopy to ground-truth the crack-failure geometry, and laser profilometry to capture surface roughness. The data sets are available, on a data repository, to the community to advance computational models to improve our ability to predict damage in brittle-ductile materials.

3-point bending↗

Exploratory analysis of machine learning techniques in the Nevada geothermal play fairway analysis

Play fairway analysis (PFA) is commonly used to generate geothermal potential maps and guide exploration studies, with a particular focus on locating and characterizing blind geothermal systems. This study evaluates the application of machine learning techniques to PFA in the Great Basin region of Nevada. Following the evaluation of various techniques, we identified two approaches to PFA that produced promising results, 1) supervised Bayesian probabilistic neural networks to generate geothermal potential maps with confidence intervals, and 2) unsupervised principal component analysis paired with k-means clustering to generate both cluster maps to help identify spatial patterns, as well as new combined feature inputs. We applied these techniques to perform a comparative analysis between two principal sets of geological and geophysical features related to permeability and heat and a set of positive (known geothermal resources) and negative training sites (known drill sites with unsuitable geothermal conditions). We found that these methods constrain previously unrecognized feature controls on geothermal favorability, many of which are spatially organized within the extent of cluster groups and the major structural-hydrologic domains of the study area. Furthermore, we utilized exploratory unsupervised modeling to highlight spatial relationships between input data and predictive output results of our supervised modeling. As a result, we demonstrate how our models compare to the previous Nevada PFA and how the rapid insights these machine learning techniques offer may support future assessments of both known and undiscovered blind geothermal systems in the Great Basin region of Nevada and beyond.

15 GEOTHERMAL ENERGY↗

Intensity-Modulated Radiotherapy for Sinonasal Tumors: Ghent University Hospital Update

Purpose: To report the long-term outcome of intensity-modulated radiotherapy (IMRT) for sinonasal tumors. Methods and Materials: Between July 1998 and November 2006, 84 patients with sinonasal tumors were treated with IMRT to a median dose of 70 Gy in 35 fractions. Of the 84 patients, 73 had a primary tumor and 11 had local recurrence. The tumor histologic type was adenocarcinoma in 54, squamous cell carcinoma in 17, esthesioneuroblastoma in 9, and adenoid cystic carcinoma in 4. The tumors were located in the ethmoid sinus in 47, maxillary sinus in 19, nasal cavity in 16, and multiple sites in 2. Postoperative IMRT was performed in 75 patients and 9 patients received primary IMRT. Results: The median follow-up of living patients was 40 months (range, 8-106). The 5-year local control, overall survival, disease-specific survival, disease-free survival, and freedom from distant metastasis rate was 70.7%, 58.5%, 67%, 59.3%, and 82.2%, respectively. No difference was found in local control and survival between patients with primary or recurrent tumors. On multivariate analysis, invasion of the cribriform plate was significantly associated with lower local control (p = 0.0001) and overall survival (p = 0.0001). Local and distant recurrence was detected in 19 and 10 patients, respectively. Radiation-induced blindness was not observed. One patient developed Grade 3 radiation-induced retinopathy and neovascular glaucoma. Nonocular late radiation-induced toxicity comprised complete lacrimal duct stenosis in 1 patient and brain necrosis in 3 patients. Osteoradionecrosis of the maxilla and brain necrosis were detected in 1 of the 5 reirradiated patients. Conclusion: IMRT for sinonasal tumors provides low rates of radiation-induced toxicity without blindness with high local control and survival. IMRT could be considered as the treatment of choi0008.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Changes Do Not Interfere With Postchemoradiation Restaging of Patients With Rectal Cancer by FDG PET/CT Before Curative Surgical Therapy

Purpose: Changes in F-18 fluorodeoxyglucose (FDG) uptake in normal tissues after chemoradiation therapy (CRT) potentially limit the ability of positron emission tomography (PET) to provide early assessment of therapeutic response. This study evaluated whether such changes negatively impact interpretation of posttherapy PET performed within 6 weeks of CRT completion and before definitive surgery in patients with locally advanced rectal cancer. The positive predictive value (PPV) and specificity of post-CRT PET, read clinically, was determined in 63 consecutive rectal cancer patients who had undergone preoperative CRT. Methods and Materials: A schema for identifying and scoring postradiation effects on PET was prospectively defined and applied in a blinded manner. This was compared with initial clinical reporting of response. Histologic assessment of the operative specimens was used as the reference standard. Correlation between clinical proctitis during CRT and radiation changes on subsequent PET was also assessed. Results: Clinical reporting of post-CRT PET yielded a high PPV (94%; 95% confidence interval, 89--100%) but may have been exaggerated by the low prevalence of complete tumor clearance (16%). The specificity was 80% with only two false-positive results. On blinded reading, significant post-CRT effects on PET were recorded in 4 of 63 patients (6% 95% confidence interval, 0-13%), but pattern recognition converted both false-positive PET results to a complete metabolic response. Clinical CRT proctitis was not correlated with PET findings. Conclusion: Postradiation effects do not appear to significantly compromise the interpretation of PET for therapeutic response assessment. The proposed PET pattern of response may further improve the specificity of PET.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visual Outcome and Tumor Control After Conformal Radiotherapy for Patients With Optic Nerve Sheath Meningioma

Purpose: Optic nerve sheath meningioma (ONSM) is a rare tumor that almost uniformly leads to visual dysfunction and even blindness without intervention. Because surgical extirpation carries a high risk of postoperative blindness, vision-sparing treatment strategies are desirable. Methods and Materials: We retrospectively reviewed the outcomes of 25 patients (25 optic nerves) with ONSM, treated at a single institution with conformal fractionated radiotherapy by either stereotactic photon or proton radiation. Primary endpoints were local control and visual acuity. Results: The patients presented with symptoms of visual loss (21) or orbital pain (3) or were incidentally diagnosed by imaging (3). The mean age was 44 years, and 64% were female patients. The indication for treatment was the development or progression of symptoms. Of the patients, 13 were treated with photons, 9 were treated with protons, and 3 received a combination of photons and protons. The median dose delivered was 50.4 gray equivalents (range, 45-59.4 gray equivalents). Median follow-up after radiotherapy was 30 months (range, 3-168 months), with 3 patients lost to follow-up. At most recent follow-up, 21 of 22 patients (95%) had improved (14) or stable (7) visual acuity. One patient had worsened visual acuity after initial postirradiation improvement. Of the 22 patients, 20 (95%) had no radiographic progression. Three patients had evidence of asymptomatic, limited retinopathy on ophthalmologic examination, and one had recurrent ONSM 11 years after treatment. Conclusions: Highly conformal, fractionated radiation therapy for symptomatic primary ONSM provides tumor control and improvement in visual function in most cases, with minimal treatment-induced morbidity. Longer follow-up is needed to assess the durability of tumor control and treatment-related late effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fractionated Conformal Radiotherapy for Management of Optic Nerve Sheath Meningiomas: Long-Term Outcomes of Tumor Control and Visual Function at a Single Institution

Purpose: To provide the long-term outcomes of patients treated with fractionated conformal radiotherapy (FCRT) for presumed optic nerve sheath meningiomas (ONSMs). Patients and Methods: Between 1995 and 2002, 9 patients with a presumed ONSM were treated with FCRT at our institution. The indications for FCRT were significant visual dysfunction at presentation, progression of visual dysfunction during a period of observation, tumor growth documented by sequential imaging, or a combination of these findings. In 2 patients, FCRT was performed as adjuvant therapy, and in 7, it was the initial and primary treatment. Results: Of the 9 patients, 6 were women and 3 were men, with a mean age of 47 years. All 9 patients had evidence of optic nerve dysfunction in the affected eye, characterized by reduced visual acuity, a visual field defect, and a relative afferent pupillary defect. In addition, 2 patients had proptosis and 1 had diplopia. The mean follow-up period was 98 {+-} 31.7 months (median, 90; range, 61-151). After FCRT, the visual function improved in the 7 patients who had undergone FCRT as the primary treatment. However, 2 patients who were blind in their affected eye at FCRT remained blind. In 4 of the 7 patients with improvement, the improvement was documented within 1-3 months after FCRT. The tumor control rate was 100%. Proptosis and diplopia also regressed in 100% of patients. At 2 years after FCRT, 1 patient had developed radiation retinopathy. Conclusion: The results of our study have shown that FCRT is a safe and effective treatment of ONSMs, affording satisfactory long-term tumor control, good functional outcome, and low treatment morbidity. FCRT should be considered the treatment of choice for patients with presumed ONSMs for whom the treatment has been deemed appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association Between Pulmonary Uptake of Fluorodeoxyglucose Detected by Positron Emission Tomography Scanning After Radiation Therapy for Non-Small-Cell Lung Cancer and Radiation Pneumonitis

Purpose: To study the relationship between fluorodeoxyglucose (FDG) uptake in pulmonary tissue after radical radiation therapy (RT) and the presence and severity of radiation pneumonitis. Methods and Materials: In 88 consecutive patients, {sup 18}F-FDG-positron emission tomography was performed at a median of 70 days after completion of RT. Patients received 60 Gy in 30 fractions, and all but 15 had concurrent platinum-based chemotherapy. RT-induced pulmonary inflammatory changes occurring within the radiation treatment volume were scored, using a visual (0 to 3) radiotoxicity grading scale, by an observer blinded to the presence or absence of clinical radiation pneumonitis. Radiation pneumonitis was retrospectively graded using the Radiation Therapy Oncology Group (RTOG) scale by an observer blinded to the PET radiotoxicity score. Results: There was a significant association between the worst RTOG pneumonitis grade occurring at any time after RT and the positron emission tomograph (PET) radiotoxicity grade (one-sided p = 0.033). The worst RTOG pneumonitis grade occurring after the PET scan was also associated with the PET radiotoxicity grade (one-sided p = 0.035). For every one-level increase in the PET toxicity scale, the risk of a higher RTOG radiation pneumonitis score increased by approximately 40%. The PET radiotoxicity score showed no significant correlation with the duration of radiation pneumonitis. Conclusions: The intensity of FDG uptake in pulmonary tissue after RT determined using a simple visual scoring system showed significant correlation with the presence and severity of radiation pneumonitis. {sup 18}F-FDG-PET may be useful in the prediction, diagnosis and therapeutic monitoring of radiation pneumonitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Planning Time and Plan Quality Through Multicriteria Optimization for Intensity-Modulated Radiotherapy

Purpose: To test whether multicriteria optimization (MCO) can reduce treatment planning time and improve plan quality in intensity-modulated radiotherapy (IMRT). Methods and Materials: Ten IMRT patients (5 with glioblastoma and 5 with locally advanced pancreatic cancers) were logged during the standard treatment planning procedure currently in use at Massachusetts General Hospital (MGH). Planning durations and other relevant planning information were recorded. In parallel, the patients were planned using an MCO planning system, and similar planning time data were collected. The patients were treated with the standard plan, but each MCO plan was also approved by the physicians. Plans were then blindly reviewed 3 weeks after planning by the treating physician. Results: In all cases, the treatment planning time was vastly shorter for the MCO planning (average MCO treatment planning time was 12 min; average standard planning time was 135 min). The physician involvement time in the planning process increased from an average of 4.8 min for the standard process to 8.6 min for the MCO process. In all cases, the MCO plan was blindly identified as the superior plan. Conclusions: This provides the first concrete evidence that MCO-based planning is superior in terms of both planning efficiency and dose distribution quality compared with the current trial and error-based IMRT planning approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IMRT for Sinonasal Tumors Minimizes Severe Late Ocular Toxicity and Preserves Disease Control and Survival

Purpose: To report late ocular (primary endpoint) and other toxicity, disease control, and survival (secondary endpoints) after intensity-modulated radiotherapy (IMRT) for sinonasal tumors. Methods and Materials: Between 1998 and 2009, 130 patients with nonmetastatic sinonasal tumors were treated with IMRT at Ghent University Hospital. Prescription doses were 70 Gy (n = 117) and 60-66 Gy (n = 13) at 2 Gy per fraction over 6-7 weeks. Most patients had adenocarcinoma (n = 82) and squamous cell carcinoma (n = 23). One hundred and one (101) patients were treated postoperatively. Of 17 patients with recurrent tumors, 9 were reirradiated. T-stages were T1-2 (n = 39), T3 (n = 21), T4a (n = 38), and T4b (n = 22). Esthesioneuroblastoma was staged as Kadish A, B, and C in 1, 3, and 6 cases, respectively. Results: Median follow-up was 52, range 15-121 months. There was no radiation-induced blindness in 86 patients available for late toxicity assessment ({>=}6 month follow-up). We observed late Grade 3 tearing in 10 patients, which reduced to Grade 1-2 in 5 patients and Grade 3 visual impairment because of radiation-induced ipsilateral retinopathy and neovascular glaucoma in 1 patient. There was no severe dry eye syndrome. The worst grade of late ocular toxicity was Grade 3 (n = 11), Grade 2 (n = 31), Grade 1 (n = 33), and Grade 0 (n = 11). Brain necrosis and osteoradionecrosis occurred in 6 and 1 patients, respectively. Actuarial 5-year local control and overall survival were 59% and 52%, respectively. On multivariate analysis local control was negatively affected by cribriform plate and brain invasion (p = 0.044 and 0.029, respectively) and absence of surgery (p = 0.009); overall survival was negatively affected by cribriform plate and orbit invasion (p = 0.04 and <0.001, respectively) and absence of surgery (p = 0.001). Conclusions: IMRT for sinonasal tumors allowed delivering high doses to targets at minimized ocular toxicity, while maintaining disease control and survival. Avoidance of severe dry eye syndrome and radiation-induced blindness suggests IMRT as a standard treatment for sinonasal tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Volumetric Modulated Arc Therapy Treatment Planning for Stage III Lung Cancer: How Does It Compare With Intensity-Modulated Radio Therapy?

Purpose: To compare the quality of volumetric modulated arc therapy (VMAT) or intensity-modulated radiation therapy (IMRT) plans generated by an automated inverse planning system with that of dosimetrist-generated IMRT treatment plans for patients with stage III lung cancer. Methods and Materials: Two groups of 8 patients with stage III lung cancer were randomly selected. For group 1, the dosimetrists spent their best effort in designing IMRT plans to compete with the automated inverse planning system (mdaccAutoPlan); for group 2, the dosimetrists were not in competition and spent their regular effort. Five experienced radiation oncologists independently blind-reviewed and ranked the three plans for each patient: a rank of 1 was the best and 3 was the worst. Dosimetric measures were also performed to quantitatively evaluate the three types of plans. Results: Blind rankings from different oncologists were generally consistent. For group 1, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.6, 2.13, and 2.18, respectively. The auto-VMAT plans in group 1 had 10% higher planning tumor volume (PTV) conformality and 24% lower esophagus V70 (the volume receiving 70 Gy or more) than the manual IMRT plans; they also resulted in more than 20% higher complication-free tumor control probability (P+) than either type of IMRT plans. The auto- and manual IMRT plans in this group yielded generally comparable dosimetric measures. For group 2, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.55, 1.75, and 2.75, respectively. Compared to the manual IMRT plans in this group, the auto-VMAT plans and auto-IMRT plans showed, respectively, 17% and 14% higher PTV dose conformality, 8% and 17% lower mean lung dose, 17% and 26% lower mean heart dose, and 36% and 23% higher P+. Conclusions: mdaccAutoPlan is capable of generating high-quality VMAT and IMRT treatment plans for stage III lung cancer. Manual IMRT plans could achieve quality similar to auto-IMRT plans if best effort was spent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of stress history in type 304L stainless steel using positron annihilation spectroscopy

Five Type 304L stainless steel specimens were subjected to incrementally increasing values of plastic strain. At each value of strain, the associated static stress was recorded and the specimen was subjected to positron annihilation spectroscopy (PAS) using the Doppler Broadening method. A calibration curve for the 'S' parameter as a function of stress was developed based on the five specimens. Seven different specimens (blind specimens labeled B1-B7) of 304L stainless steel were subjected to values of stress inducing plastic deformation. The values of stress ranged from 310 to 517 MPa. The seven specimens were subjected to PAS post-loading using the Doppler Broadening method, and the results were compared against the developed curve from the previous five specimens. It was found that a strong correlation exists between the 'S' parameter, stress, and strain up to a strain value of 15%, corresponding to a stress value of 500 MPa, beyond which saturation of the 'S' parameter occurs. Research Highlights: {yields} Specimens were initially in an annealed/recrystallized condition. {yields} Calibration results indicate positron annihilation measurements yield correlation. {yields} Deformation produced by cold work was likely larger than the maximum strain.

36 MATERIALS SCIENCE↗

A treatment planning comparison between modulated tri-cobalt-60 teletherapy and linear accelerator–based stereotactic body radiotherapy for central early-stage non−small cell lung cancer

We evaluated the feasibility of planning stereotactic body radiotherapy (SBRT) for large central early-stage non−small cell lung cancer with a tri-cobalt-60 (tri-{sup 60}Co) system equipped with real-time magnetic resonance imaging (MRI) guidance, as compared to linear accelerator (LINAC)–based SBRT. In all, 20 patients with large central early-stage non−small cell lung cancer who were treated between 2010 and 2015 with LINAC-based SBRT were replanned using a tri-{sup 60}Co system for a prescription dose of 50 Gy in 4 fractions. Doses to organs at risk were evaluated based on established MD Anderson constraints for central lung SBRT. R{sub 100} values were calculated as the total tissue volume receiving 100% of the dose (V{sub 100}) divided by the planning target volume and compared to assess dose conformity. Dosimetric comparisons between LINAC-based and tri-{sup 60}Co SBRT plans were performed using Student's t-test and Wilcoxon Ranks test. Blinded reviews by radiation oncologists were performed to assess the suitability of both plans for clinical delivery. The mean planning target volume was 48.3 cc (range: 12.1 to 139.4 cc). Of the tri-{sup 60}Co SBRT plans, a mean 97.4% of dosimetric parameters per patient met MD Anderson dose constraints, whereas a mean 98.8% of dosimetric parameters per patient were met with LINAC-based SBRT planning (p = 0.056). R{sub 100} values were similar between both plans (1.20 vs 1.21, p = 0.79). Upon blinded review by 4 radiation oncologists, an average of 90% of the tri-{sup 60}Co SBRT plans were considered acceptable for clinical delivery compared with 100% of the corresponding LINAC-based SBRT plans (p = 0.17). SBRT planning using the tri-{sup 60}Co system with built-in MRI is feasible and achieves clinically acceptable plans for most central lung patients, with similar target dose conformity and organ at risk dosimetry. The added benefit of real-time MRI-guided therapy may further optimize tumor targeting while improving normal tissue sparing, which warrants further investigation in a prospective feasibility clinical trial.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accurate structure prediction of peptide–MHC complexes for identifying highly immunogenic antigens

Designing an optimal HIV-1 vaccine faces the challenge of identifying antigens that induce a broad immune capacity. One factor to control the breadth of T cell responses is the surface morphology of a peptide–MHC complex. Here, we present an in silico protocol for predicting peptide–MHC structure. A robust signature of a conformational transition was identified during all-atom molecular dynamics, which results in a model with high accuracy. A large test set was used in constructing our protocol and we went another step further using a blind test with a wild-type peptide and two highly immunogenic mutants, which predicted substantial conformational changes in both mutants. The center residues at position five of the analogs were configured to be accessible to solvent, forming a prominent surface, while the residue of the wild-type peptide was to point laterally toward the side of the binding cleft. We then experimentally determined the structures of the blind test set, using high resolution of X-ray crystallography, which verified predicted conformational changes. Our observation strongly supports a positive association of the surface morphology of a peptide–MHC complex to its immunogenicity. Our study offers the prospect of enhancing immunogenicity of vaccines by identifying MHC binding immunogens.

Park, Min-Sun↗