Search for C P Violation in Neutrino and Antineutrino Oscillations by the T2K Experiment with 2.2 × 10 21 Protons on Target
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Airframe noise is a significant component of environmental noise in the vicinity of airports. The noise associated with the leading-edge slat of typical transport aircraft is a prominent source of airframe noise. Previous work suggests that a slat-cove filler (SCF) may be an effective noise treatment. Hence, development and optimization of a practical slat-cove-filler structure is a priority. The objectives of this work are to optimize the design of a functioning SCF which incorporates superelastic shape memory alloy (SMA) materials as flexures that permit the deformations involved in the configuration change. The goal of the optimization is to minimize the actuation force needed to retract the slat-SCF assembly while satisfying constraints on the maximum SMA stress and on the SCF deflection under static aerodynamic pressure loads, while also satisfying the condition that the SCF self-deploy during slat extension. A finite element analysis model based on a physical bench-top model is created in Abaqus such that automated iterative analysis of the design could be performed. In order to achieve an optimized design, several design variables associated with the current SCF configuration are considered, such as the thicknesses of SMA flexures and the dimensions of various components, SMA and conventional. Designs of experiment (DOE) are performed to investigate structural response to an aerodynamic pressure load and to slat retraction and deployment. DOE results are then used to inform the optimization process, which determines a design minimizing actuator forces while satisfying the required constraints.
A much more efficient Ring Imaging Cherenkov sub-detector system will be rebuilt in the second long shutdown of Large Hadron Collider for the LHCb experiment. Radiation-hard electronic components together with Commercial Off-The-Shelf ones will be used in the new Cherenkov photon detection system architecture. An irradiation program was foreseen to determine the radiation tolerance for the new electronic devices, including a Field Programmable Gate Array from KINTEX-7 family of XILINX. An automated test bench for online monitoring of the XC7K70T KINTEX-7 device operation in radiation conditions was designed and implemented by the LHCb Romanian group.
Reproducing, exchanging, comparing, and building on each other’s work is foundational to technology advances. Advancing biotechnology calls for reliable reuse of engineered organisms. Reliable reuse of engineered organisms requires reproducible growth and productivity. Here, we identify the experimental factors that have the greatest effect on the growth and productivity of our engineered organisms in order to demonstrate reproducibility for biotechnology. Here, we present a draft of a Minimum Information Standard for Engineered Organism Experiments based on this method. We evaluate the effect of 22 factors on Escherichia coli engineered to produce the small molecule lycopene, and 18 factors on E. coli engineered to produce red fluorescent protein. Container geometry and shaking have the greatest effect on product titer and yield. We reproduce our results under two different conditions of reproducibility: conditions of use (different fractional factorial experiments), and time (48 biological replicates performed on 12 different days over four months).
Gas absorption towers with structured packing and solvent have been used for Carbon Dioxide (CO 2 ) Capture for about many decades. To overcome process limitations and practical disadvantages for CO 2 capture from the stationary emitter (e.g. NG and coal power plant), many new designs have been proposed and explored at the various scales in the last decade with aim of either low energy penalty or low capital cost. To reduce the size of the absorption tower and hence the total cost of CO 2 capture, the University of Kentucky Center for Applied Energy Research Center (UK CAER) has designed and built a novel CO 2 capture absorption tower or Compact Absorber, integrated into an existing large-bench scale CO 2 capture unit. The Compact Absorber has three sections. The top of the column is a fogging section where the solvent is sprayed through a nozzle producing droplets flowing downward in a co-current fashion with the flue gas. The center of the column is a frothing section where the solvent and flue gas flow through regenerative frothing screens designed by Industrial Climate Solutions, Inc. The bottom of the column is a typical structured packing section were the flue gas and solvent flow in a counter-current fashion. The parametric campaign will be conducted in order to optimize the operating parameters for CO 2 capture including liquid/gas ratio, lean loading, and temperature, liquid residence time. A simulated flue gas with 14% CO 2 will be used along with a UK CAER developed proprietary solvent. The 100-hour parametric campaign is designed using a statistical approach of the Sequential Design of Experiments (sDOE). sDOE is one of the CCSI tools that provides an adaptive statistical approach for designing future experiments based on the results of previous experiments. Application of a typical DOE provides the user with the minimum number of experiments required to get the same data, but sDOE allows the user to make an informed choice of experiments based on the results of previous experiments. The complete absorption column has been constructed and has been partially commissioned. Initial data has been collected by operating using the fogging section and the frothing section. The fogging section produces solvent droplets of about 100 μm sauter mean diameter and as small as 25 μm using a hydraulic nozzle by BETE. The frothing section produces bubbles of about 5mm with high mixing of solvent promoting the higher mass transfer from gas to liquid. The absorber reaches the capture efficiency of about 50% with only two sections in operation. Based on the current results, it can be deduced that increasing the solvent feed temperature and including the packed section for absorption the capture efficiency will increase further. Initial data will be collected using all three sections of the absorber and will be used for sDOE. Non-Uniform Space Filling model of sDOE will be used to prioritize the input conditions resulting into maximum capture efficiency. sDOE is performed using the platform called Framework Optimization, Quantification of Uncertainty, and Surrogates (FOQUS). The method and results demonstrating the progress of the parametric campaign from the initial set of experiments to the final stage of obtaining optimized parameters using sDOE tool will be presented in detail.
This SPP project with Novus was to investigate tribological properties of candidate ceramic composites. Systematic tribological bench tests and surface characterization were performed to determine composition-property relationships of several Zr-Ti-B based ceramic composites of different compositions. The lowest friction coefficient was measured with Ti0.6Zr0.4B2 composition tested in the hydraulic oil. Surface characterization suggests a formation of ZDDP tribofilm in the worn region when tested with a hydraulic oil. In all experiments, the ceramic composites did not have measurable wear, but caused material loss of the steel countersurface.
In situ and ex situ catalytic pyrolysis were compared in a system with two 2-in. bubbling fluidized bed reactors. Pine was pyrolyzed in the system with a catalyst, HZSM-5 with a silica-to-alumina ratio of 30, placed either in the first (pyrolysis) reactor or the second (upgrading) reactor. Both the pyrolysis and upgrading temperatures were 500 degrees C, and the weight hourly space velocity was 1.1 h -1 . Five catalytic cycles were completed in each experiment. The catalytic cycles were continued until oxygenates in the vapors became dominant. The catalyst was then oxidized, after which a new catalytic cycle was begun. The in situ configuration gave slightly higher oil yield but also higher oxygen content than the ex situ configuration, which indicates that the catalyst deactivated faster in the in situ configuration than the ex situ configuration. Analysis of the spent catalysts confirmed higher accumulation of metals in the in situ experiment. In all experiments, the organic oil mass yields varied between 14 and 17% and the carbon efficiencies between 20 and 25%. The organic oxygen concentrations in the oils were 16-18%, which represented a 45% reduction compared to corresponding noncatalytic pyrolysis oils prepared in the same fluidized bed reactor system. GC/MS analysis showed the oils to contain one- to four-ring aromatic hydrocarbons and a variety of oxygenates (phenols, furans, benzofurans, methoxyphenols, naphthalenols, indenols). Lastly, high fractions of oxygen were rejected as water, CO, and CO 2 , which indicates the importance of dehydration, decarbonylation, and decarboxylation reactions. Light gases were the major sources of carbon losses, followed by char and coke.
Not Available
This document will detail a test procedure, involving bench and emulation testing, for the Module OT device developed for the joint NREL-SNL DOE CEDS project titled "Modular Security Apparatus for Managing Distributed Cryptography for Command & Control Messages on Operational Technology (OT) Networks." The aim of this document is to create the testing and evaluation protocol for the module for lab-level testing; this includes checklists and experiments for information gathering, functional testing, cryptographic implementation, public key infrastructure, key exchange/authentication, encryption, and implementation testing in the emulation environment.
LASE now has the advantage of being economically upgraded and customized with COTS hardware and software while using "C" software language. These changes are made so as not to destroy the form, fit and functional characteristics required for flights aboard the ER-2 aircraft. The LASE Instrument can now be quickly adapted to fly onboard ER-2, P-3, C-130 and DC-8 aircraft. The adaptability of the CDS upgraded electronics compliments other modular subsystems like the laser optical bench in that it was designed to be a test bed for new technology lasers.
This work presents first experiments toward the development of continuously renewable (extrudable) pebble-based carbon rods for use as plasma-facing components in extreme steady-state plasma flux environments. The primary envisioned application of this work is a first wall that can survive long-term in future magnetic fusion power reactors while also improving recovery of the reactor fuel (tritium and deuterium atoms). Bench tests applying extreme steady-state front-surface heat loads of up to 50 MW/m 2 are presented. Continuous pebble rod front-surface recession and intact pebble recovery are successfully demonstrated, at a rate of order 0.2 cm/s. Numerical simulations of the pebble rod front-surface recession are able to match observations reasonably well, indicating that the recession mechanism can be understood as occurring due to pebble thermal expansion and resulting shock and cracking of the inter-pebble binder. Tests of the pebble rod extrusion demonstrate that friction between the rods and the stainless-steel extrusion channel is tolerably low (<50 N for the expected channel length) over a wide range of temperatures. Front-surface outgassing rates below 1000 Torr L/s/m 2 are achieved, believed to be sufficiently low for use in magnetic fusion reactors. In conclusion, initial parametric scans over pebble rod size and binder fraction to vary front-surface recession rates are presented.
A test stand is under construction at CERN to study high perveance electron guns, electron beam dynamics, and electron beam diagnostics for electron lenses. It will be used to test electron guns for the Hollow Electron Lenses under consideration for beam halo control for High Luminosity LHC (CERN), and for the Space Charge Compensation at SIS18 (GSI) in the frame of the EU funded ARIES project. In order to prepare for this test stand, simulations will be presented and compared with experiments undertaken at the Fermilab (FNAL) electron lens test stand. These were conducted using a hollow electron gun, with the magnetic field configuration and beam current varied to study their effect. The impact of imperfections on the beam dynamics and overall quality of the electron beam will be discussed. A method for comparing experimental data with simulation is also presented to allow bench-marking of the computer models and simulation tools that will later be applied to the analysis of measurements performed at CERN.
A document discusses a solution-assisted contacting technique for optical contacting. An optic of surface flatness Lambda/20 was successfully contacted with one of moderate surface quality, or Lambda/4. Optics used were both ultra-low expansion (ULE) glass (Lambda/4 and Lambda/20) and fused silica (Lambda/20). A stainless steel template of the intended interferometer layout was designed and constructed with three contact points per optic. The contact points were all on a common side of the template. The entire contacting jig was tilted at about 30 . Thus, when the isopropanol was applied, each optic slid due to gravity, resting on the contact points. All of the contacting was performed in a relatively dusty laboratory. A number of successful contacts were achieved where up to two or three visible pieces of dust could be seen. These were clearly visible due to refraction patterns between the optic and bench. On a number of optics, the final step of dropping isopropyl between the surfaces was repeated until a successful contact was achieved. The new procedures realized in this work represent a simplification for optical contacting in the laboratory. They will both save time and money spent during the contacting process, and research and development phases. The techniques outlined are suitable for laboratory experiments, research, and initial development stages.
Thermal aging and sulfur poisoning are major problems influencing the efficiency and lifetime of natural gas three-way catalysts (TWCs) during real-world operation. In the present study, thermal aging and sulfur-induced deactivations on CH 4 combustion were investigated over commercial monolithic honeycombs, i.e., Pd/CexZr 1-x O 2 (CZ)-based TWCs that are thermally aged in the bench (HTA), followed by being operated behind the stoichiometric natural gas engine in high sulfur fuel (HTA + S). In this work, both HTA and HTA + S samples show degraded performance in CH 4 combustion relative to the fresh one, which are caused by the reconstruction of Pd species induced by thermal aging and the decreased reducibility of the support. The 18 O 2 labelling experiments show that in all cases CH 4 combustion proceeds via a MvK mechanism in which lattice O (OL) plays a key role. The sulfation aging (HTA + S sample) promotes the activation of CH 4 and O 2 by forming Pd δ+ -(SO$_4^{2-}$) δ- and Ce 3+ -VO couples at the interface as compared to HTA sample. However, such a promotion effect could be compromised by the blocking effect of sulfate on the exchange of O L from the bulk to the surface and across the surface. The fundamental understanding of thermal and S deactivation mechanisms from this study could help to predict a real-world lifetime use curve of natural gas TWCs.
Releases from the F and H Area Seepage Basins on the Savannah River Site (SRS) have caused groundwater plumes that contain a variety of contaminants. These plumes are releasing contaminants into Fourmile Branch, which is a small tributary of the Savannah River. The metallic contaminant releases to the branch are being controlled by base injection. The base injection targets cationic contaminants and was not intended to reduce the concentration of I-129 in groundwater. SRS and the regulatory agencies believe it is appropriate to investigate remedial alternatives that could reduce the I-129. The Savannah River Site Area Closures Projects (ACP) and the Savannah River National Laboratory (SRNL) are developing an innovative in situ treatment for I-129 using silver chloride (AgCl). The proposed AgCl amendment has a very small particle size and is designed to be injected into the contaminated aquifer to capture I-129. The solubility of AgI is several orders of magnitude lower than the solubility of AgCl. Thus, when I-129 comes in contact with AgCl it forms silver iodide (AgI), which is very stable and essentially insoluble in water. SRNL has been performing bench-scale column tests on the effectiveness of silver chloride to capture iodine in an aqueous solution. These initial tests evaluate silver chloride in four different particle sizes; 4-5 millimeters (standard reagent silver chloride), approximately 1 millimeters (sieved reagent silver chloride), approximately 2 micrometers (ultra fine grind without a grinding agent), and <1 micrometer (ultra fine grind with a grinding agent). The first two experiments with macro-sized particles were proof of principle tests. In these the AgCl was mechanically mixed into a portion of the soil filling the columns. The last two were to test the effectiveness of injecting particles suspended in an aqueous solution--the ability to inject the particles, their retention in the column and their effectiveness at removing dissolved iodide from solution. The amendments for these two columns were obtained from a private company specializing in ultra-fine grinding of materials. They were ground in propylene glycol because when ground in water silver metal electroplated onto the steel grinding equipment. Table 1 shows the list of columns and the amendment characteristics. The results of these column experiments demonstrate that solid silver chloride is highly effective at removing dissolved iodine from water and should be an effective amendment for removing I-129 from groundwater. Based on known groundwater chemistry and the reaction of AgCl with I- to produce AgI, the only interference will be natural dissolved stable iodine (I-127). Millings et al. (2002) reported a maximum I-127 concentration of 2.2 ug/L in groundwater from well P-27D, a background water table well near F-Area. The concentration of dissolved iodide used in these experiments is approximately 4500 times this natural concentration. Therefore, a AgCl amendment in the subsurface at the same concentration used in these experiments, might effectively remove I-129 for up to 4500 times the number of pore volumes of groundwater as observed here. This assumes homogeneous distribution of the amendment and no occlusion by other minerals in the subsurface. The only reliable way to evaluate these effects is by trial in the field. The column studies also suggest that the amendment is readily injectable into sediments, but will not be highly mobile. The fact that the effluent from Column 4 shows no iodide breakthrough after nearly 11 pore volumes indicates that some of the injected AgCl was trapped in the column. A mass balance on iodide reacted so far suggests that a minimum of 0.056 grams of silver chloride was trapped in the column to react with the iodide. This is 5.6% of the mass injected. Assume the 1-foot column represents the first foot of sediment in the subsurface into which the amendment is injected. If 5.6% of the AgCl particles are trapped in each subsequent foot of sediment through which the injectate moves, at 100 feet the concentration of particles will be 3% of the injection concentration. This is the maximum possible concentration indicated by these column studies, because far more AgCl may have been trapped in the column. Continued data collection will tell how much more. Dissolved silver concentrations from the silver chloride amendment will be low. Effluent from Column 1 was analyzed for dissolved silver and the concentrations were below the detection limit of 0.2 mg/L.
The silicon vertex tracker (VTX) will be installed in the summer of 2010 to enhance the physics capabilities of the Pioneering High Energy Nuclear Interaction eXperiment (PHENIX) experiment at Brookhaven National Laboratory. The VTX consists of two types of silicon detectors: a pixel detector and a strip detector. The pixel detector consists of 30 pixel ladders placed on the two inner cylindrical layers of the VTX. The ladders are required to be assembled with high precision, however, they should be assembled in both cost and time efficient manner. We have developed an assembly bench for the ladder with several assembly fixtures and a quality assurance (Q/A) system using a 3D measurement machine. We have also developed an assembly procedure for the ladder, including a method for dispensing adhesive uniformly and encapsulation of bonding wires. The developed procedures were adopted in the assembly of the first pixel ladder and satisfy the requirements.
The suitport concept has been recently implemented as part of the small pressurized lunar rover (Currently the Space Exploration vehicle, or SEV) and the Multi-Mission Space Exploration Vehicle (MMSEV) concept demonstrator vehicle. Suitport replaces or augments the traditional airlock function of a spacecraft by providing a bulkhead opening, capture mechanism, and sealing system to allow ingress and egress of a spacesuit while the spacesuit remains outside of the pressurized volume of the spacecraft. This presents significant new opportunities to EVA exploration in both microgravity and surface environments. The suitport concept will enable three main improvements in EVA by providing reductions in: pre-EVA time from hours to less than thirty minutes; airlock consumables; contamination returned to the cabin with the EVA crewmember. To date, the first generation suitport has been tested with mockup suits on the rover cabins and pressurized on a bench top engineering unit. The work on the rover cabin has helped define the operational concepts and timelines, and has demonstrated the potential of suitport to save significant amounts of crew time before and after EVAs. The work with the engineering unit has successfully demonstrated the pressurizable seal concept including the ability to seal after the introduction and removal of contamination to the sealing surfaces. Using this experience, a second generation suitport was designed. This second generation suitport has been tested with a spacesuit prototype using the pressure differentials of the spacecraft. This test will be performed using the JSC B32 Chamber B, a human rated vacuum chamber. This test will include human rated suitports, the suitport compatible prototype suit, and chamber modifications. This test will bring these three elements together in the first ever pressurized donning of a rear entry suit through a suitport. This paper presents design of a human rated second generation suitport, modifications to the JSC human rated chamber B to accept a suitport, and a compatible space suit to support pressurized human donning of the pressurized suit through a suitport. Design challenges and solutions and compromises required to develop the system are presented. Initial human testing results are presented.
The suitport concept has been recently implemented as part of the small pressurized lunar rover (Currently the Space Exploration vehicle, or SEV) and the Multi-Mission Space Exploration Vehicle (MMSEV) concept demonstrator vehicle. Suitport replaces or augments the traditional airlock function of a spacecraft by providing a bulkhead opening, capture mechanism, and sealing system to allow ingress and egress of a space suit while the space suit remains outside of the pressurized volume of the spacecraft. This presents significant new opportunities to EVA exploration in both microgravity and surface environments. The suitport concept will enable three main improvements in EVA by providing reductions in: pre-EVA time from hours to less than thirty minutes; airlock consumables; contamination returned to the cabin with the EVA crewmember. To date, the first generation suitport has been tested with mockup suits on the rover cabins and pressurized on a bench top engineering unit. The work on the rover cabin has helped define the operational concepts and timelines, and has demonstrated the potential of suitport to save significant amounts of crew time before and after EVAs. The work with the engineering unit has successfully demonstrated the pressurizable seal concept including the ability to seal after the introduction and removal of contamination to the sealing surfaces. Using this experience, a second generation suitport was designed. This second generation suitport has been tested with a space suit prototype on the second generation MMSEV cabin, and testing is planned using the pressure differentials of the spacecraft. Pressurized testing will be performed using the JSC B32 Chamber B, a human rated vacuum chamber. This test will include human rated suitports, a suitport compatible prototype suit, and chamber modifications. This test will bring these three elements together in the first ever pressurized donning of a rear entry suit through a suitport. This paper presents the design of a human rated second generation suitport, the design of a suit capable of supporting pressurized human donning through a suitport, ambient pressure testing of the suit with the suitport, and modifications to the JSC human rated chamber B to accept a suitport. Design challenges and solutions, as well as compromises required to develop the system, are presented. Initial human testing results are presented.