Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Formation of a spatial laser-beam profile in a channel of high-power neodymium facilities

A system for one-dimensional spatial profiling of a laser beam is suggested, capable of compensating for the spatial laserbeam distortions that arise due to a nonuniform gain distribution over the aperture in the amplifying channel of high-power Nd:glass lasers with wide-aperture stages on disk active elements. The principle of operation, the approach to calculation of the key element parameters, and calculation and experimental results of studying the formation of spatial profiles of the laser beam intensity at the output from the system in question are described. Possible applications of the system both in single-beam and multi-beam optical schemes are considered. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-shot electron bunch length measurements using a spatial electro-optical autocorrelation interferometer

A spatial, electro-optical autocorrelation (EOA) interferometer using the vertically polarized lobes of coherent transition radiation (CTR) has been developed as a single-shot electron bunch length monitor at an optical beam port downstream the 100 MeV preinjector LINAC of the Swiss Light Source. This EOA monitor combines the advantages of step-scan interferometers (high temporal resolution) [D. Mihalcea et al., Phys. Rev. ST Accel. Beams 9, 082801 (2006) and T. Takahashi and K. Takami, Infrared Phys. Technol. 51, 363 (2008)] and terahertz-gating technologies [U. Schmidhammer et al., Appl. Phys. B: Lasers Opt. 94, 95 (2009) and B. Steffen et al., Phys. Rev. ST Accel. Beams 12, 032802 (2009)] (fast response), providing the possibility to tune the accelerator with an online bunch length diagnostics. While a proof of principle of the spatial interferometer was achieved by step-scan measurements with far-infrared detectors, the single-shot capability of the monitor has been demonstrated by electro-optical correlation of the spatial CTR interference pattern with fairly long (500 ps) neodymium-doped yttrium aluminum garnet (Nd:YAG) laser pulses in a ZnTe crystal. In single-shot operation, variations of the bunch length between 1.5 and 4 ps due to different phase settings of the LINAC bunching cavities have been measured with subpicosecond time resolution.

36 MATERIALS SCIENCE↗

In-situ piezoresponse force microscopy cantilever mode shape profiling

The frequency-dependent amplitude and phase in piezoresponse force microscopy (PFM) measurements are shown to be a consequence of the Euler-Bernoulli (EB) dynamics of atomic force microscope (AFM) cantilever beams used to make the measurements. Changes in the cantilever mode shape as a function of changes in the boundary conditions determine the sensitivity of cantilevers to forces between the tip and the sample. Conventional PFM and AFM measurements are made with the motion of the cantilever measured at one optical beam detector (OBD) spot location. A single OBD spot location provides a limited picture of the total cantilever motion, and in fact, experimentally observed cantilever amplitude and phase are shown to be strongly dependent on the OBD spot position for many measurements. In this work, the commonly observed frequency dependence of PFM response is explained through experimental measurements and analytic theoretical EB modeling of the PFM response as a function of both frequency and OBD spot location on a periodically poled lithium niobate sample. One notable conclusion is that a common choice of OBD spot location—at or near the tip of the cantilever—is particularly vulnerable to frequency dependent amplitude and phase variations stemming from dynamics of the cantilever sensor rather than from the piezoresponse of the sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design considerations and validation of the MSTAR absolute metrology system

Absolute metrology measures the actual distance between two optical fiducials. A number of methods have been employed, including pulsed time-of-flight, intensity-modulated optical beam, and two-color interferometry. The rms accuracy is currently limited to -5 microns. Resolving the integer number of wavelengths requires a 1-sigma range accuracy of -0.1 microns. Closing this gap has a large pay-off the range (length measurement) accuracy can be increased substantially using the unambiguous optical phase. The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. In this paper, we present recent experiments that use dispersed white light interferometry to independently validate the zero-point of the system. We also describe progress towards reducing the size of optics, and stabilizing the laser wavelength for operation over larger target ranges. MSTAR is a general-purpose tool for conveniently measuring length with much greater accuracy than was previously possible, and has a wide range of possible applications.

Jeganathan, Muthu↗

Laser Damage Precursors in Fused Silica

There is a longstanding, and largely unexplained, correlation between the laser damage susceptibility of optical components and both the surface quality of the optics, and the presence of near surface fractures in an optic. In the present work, a combination of acid leaching, acid etching, and confocal time resolved photoluminescence (CTP) microscopy has been used to study laser damage initiation at indentation sites. The combination of localized polishing and variations in indentation loads allows one to isolate and characterize the laser damage susceptibility of densified, plastically flowed and fractured fused silica. The present results suggest that: (1) laser damage initiation and growth are strongly correlated with fracture surfaces, while densified and plastically flowed material is relatively benign, and (2) fracture events result in the formation of an electronically defective rich surface layer which promotes energy transfer from the optical beam to the glass matrix.

42 ENGINEERING↗

A soft X-ray beam-splitting multilayer optic for the NASA GEMS Bragg Reflection Polarimeter

A soft X-ray, beam-splitting, multilayer optic has been developed for the Bragg Reflection Polarimeter (BRP) on the NASA Gravity and Extreme Magnetism Small Explorer Mission (GEMS). The optic is designed to reflect 0.5 keV X-rays through a 90° angle to the BRP detector, and transmit 2–10 keV X-rays to the primary polarimeter. The transmission requirement prevents the use of a thick substrate, so a 2 μm thick polyimide membrane was used. Atomic force microscopy has shown the membrane to possess high spatial frequency roughness less than 0.2 nm rms, permitting adequate X-ray reflectance. A multilayer thin film was especially developed and deposited via magnetron sputtering with reflectance and transmission properties that satisfy the BRP requirements and with near-zero stress. Furthermore, reflectance and transmission measurements of BRP prototype elements closely match theoretical predictions, both before and after rigorous environmental testing.

36 MATERIALS SCIENCE↗

Cryogenic Scan Mechanism for Fourier Transform Spectrometer

A compact and lightweight mechanism has been developed to accurately move a Fourier transform spectrometer (FTS) scan mirror (a cube corner) in a near-linear fashion with near constant speed at cryogenic temperatures. This innovation includes a slide mechanism to restrict motion to one dimension, an actuator to drive the motion, and a linear velocity transducer (LVT) to measure the speed. The cube corner mirror is double-passed in one arm of the FTS; double-passing is required to compensate for optical beam shear resulting from tilting of the moving cube corner. The slide, actuator, and LVT are off-the-shelf components that are capable of cryogenic vacuum operation. The actuator drives the slide for the required travel of 2.5 cm. The LVT measures translation speed. A proportional feedback loop compares the LVT voltage with the set voltage (speed) to derive an error signal to drive the actuator and achieve near constant speed. When the end of the scan is reached, a personal computer reverses the set voltage. The actuator and LVT have no moving parts in contact, and have magnetic properties consistent with cryogenic operation. The unlubricated slide restricts motion to linear travel, using crossed roller bearings consistent with 100-million- stroke operation. The mechanism tilts several arc seconds during transport of the FTS mirror, which would compromise optical fringe efficiency when using a flat mirror. Consequently, a cube corner mirror is used, which converts a tilt into a shear. The sheared beam strikes (at normal incidence) a flat mirror at the end of the FTS arm with the moving mechanism, thereby returning upon itself and compensating for the shear

Brasunas, John C.↗

SU-C-201-02: Dosimetric Verification of SBRT with FFF-VMAT Using a 3-D Radiochromic/Optical-CT Dosimetry System

Purpose: With an increasing use of small field size and high dose rate irradiation in the advances of radiotherapy techniques, such as stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS), an in-depth quality assurance (QA) system is required. The purpose of this study is to investigate a high resolution optical CT-based 3D radiochromic dosimetry system for SBRT with intensity modulated radiotherapy (IMRT) and flattening filter free (FFF) volumetric modulated arc therapy (VMAT). Methods: Cylindrical PRESAGE radiochromic dosimeters of 10cm height and 11cm diameter were used to validate SBRT. Four external landmarks were placed on the surface of each dosimeter to define the isocenter of target. SBRT plans were delivered using a Varian TrueBeam™ linear accelerator (LINAC). Three validation plans, SBRT with IMRT (6MV 600MU/min), FFF-VMAT (10MV 2400MU/min), and mixed FFF-VMAT (6MV 1400MU/min, 10MV 2400MU/min), were delivered to the PRESAGE dosimeters. Each irradiated PRESAGE dosimeter was scanned using a single laser beam optical CT scanner and reconstructed with a 1mm × 1mm high spatial resolution. The comparison of measured dose distributions of irradiated PRESAGE dosimeters to those calculated by Pinnacle{sup 3} treatment planning system (TPS) were performed with a 10% dose threshold, 3% dose difference (DD), and 3mm distance-to-agreement (DTA) Gamma criteria. Results: The average pass rates for the gamma comparisons between PRESAGE and Pinnacle{sup 3} in the transverse, sagittal, coronal planes were 94.6%, 95.9%, and 96.4% for SBRT with IMRT, FFF-VMAT, and mixed FFF-VMAT plans, respectively. A good agreement of the isodose distributions of those comparisons were shown at the isodose lines 50%, 70%, 80%, 90% and 98%. Conclusion: This study demonstrates the feasibility of the high resolution optical CT-based 3D radiochromic dosimetry system for validation of SBRT with IMRT and FFF-VMAT. This dosimetry system offers higher precision QA with 3D dose information for small beams compared to what is currently available.

60 APPLIED LIFE SCIENCES↗

EBIC and LBIC studies of the properties of extended defects in plastically deformed silicon

The results of comparative experimental studies of one- and two-dimensional defects in plastically deformed silicon by the electron-beam-induced current (EBIC) and light-beam-induced current (LBIC) techniques are reported. It is shown that the contrast of two-dimensional defects (dislocation trails) in the LBIC method can by much more pronounced than that in the EBIC technique, which is in good agreement with the results of calculations. The higher sensitivity of the LBIC technique is mainly due to deeper penetration of the optical beam into the material in comparison to the penetration of the electron beam of a scanning electron microscope.

36 MATERIALS SCIENCE↗

Thick beryllium coatings by magnetron sputtering

Thick (>150 {micro}m) beryllium coatings are studied as an ablator material of interest for fusion fuel capsules for the National Ignition Facility (NIF). As an added complication, the coatings are deposited on mm-scale spherical substrates, as opposed to flats. DC magnetron sputtering is used because of the relative controllability of the processing temperature and energy of the deposits. We used ultra small angle x-ray spectroscopy (USAXS) to characterize the void fraction and distribution along the spherical surface. We investigated the void structure using a combination focused ion beam (FIB) and scanning electron microscope (SEM), along with transmission electron microscopy (TEM). Our results show a few volume percent of voids and a typical void diameter of less than two hundred nanometers. Understanding how the stresses in the deposited material develop with thickness is important so that we can minimize film cracking and delamination. To that end, an in-situ multiple optical beam stress sensor (MOSS) was used to measure the stress behavior of thick Beryllium coatings on flat substrates as the material was being deposited. We will show how the film stress saturates with thickness and changes with pressure.

42 ENGINEERING↗

System and method for parallel two-photon lithography using a metalens array

A metalens array is disclosed for controllably modifying a phase of a wavefront of an optical beam. The metalens array may have a substrate having at least first and second metalens unit cells, and forming a single integrated structure with no stitching being required of the first and second metalens unit cells. The first metalens unit cell has a first plurality of nanoscale features and is configured to modify a phase of a first portion of a wavefront of an optical signal incident thereon in accordance with a first predetermined phase pattern to create at least one first focal voxel within an image plane. The second metalens unit cell has a second plurality of nanoscale features configured to modify the phase of a second portion of the wavefront of the optical signal incident thereon, in accordance with a second predetermined phase pattern, to simultaneously create at least one second focal voxel within the image plane. Each metalens unit cell also has an overall diameter of no more than about 200 microns.

Xia, Xiaoxing↗

Development of combined microstructure and structure characterization facility for in situ and operando studies at the Advanced Photon Source

Following many years of evolutionary development, first at the National Synchrotron Light Source, Brookhaven National Laboratory, and then at the Advanced Photon Source (APS), Argonne National Laboratory, the APS ultra-small-angle X-ray scattering (USAXS) facility has been transformed by several new developments. These comprise a conversion to higher-order crystal optics and higher X-ray energies as the standard operating mode, rapid fly scan measurements also as a standard operational mode, automated contiguous pinhole small-angle X-ray scattering (SAXS) measurements at intermediate scattering vectors, and associated rapid wide-angle X-ray scattering (WAXS) measurements for X-ray diffraction without disturbing the sample geometry. With each mode using the USAXS incident beam optics upstream of the sample, USAXS/SAXS/WAXS measurements can now be made within 5 min, allowing in situ and operando measurement capabilities with great flexibility under a wide range of sample conditions. Furthermore, these developments are described, together with examples of their application to investigate materials phenomena of technological importance. Developments of two novel USAXS applications, USAXS-based X-ray photon correlation spectroscopy and USAXS imaging, are also briefly reviewed.

47 OTHER INSTRUMENTATION↗

All-Optical Micro Motors Based on Moving Gratings in Photosensitive Media

This research effort was a feasibility study of the concept of an all-optical micro motor with a rotor driven by a traveling wave. The wave was a result of a photo induced surface deformation of a photosensitive material produced by a traveling holographic grating. Two phases modulated coherent optical beams were used to generate the grating in two types of photosensitive materials. The materials that were studied were photorefractive crystals and thin polymer films. Theoretical studies were performed on lithium niobate giving predictions of deformations of the order of nanometers. The experimental deformation size was also on the order of nanometers. The deformations were deep enough to provide conditions for the implementation of the all-optical motor using lithium niobate. We also were able to align micron-size dielectric particles along the holographic gratings by means of the periodic electric forces generated by the grating. These forces can also move the particles along the surface if the grating is moving. We then turned our attention on thin films and obtained a deformation visible on the order of 100 microns. An experimental breadboard demonstration of a prototype was done in the summer of 2001 at Glenn Research Center (GRC). The demonstration included the movement of clocks mechanical workings by an optically driven motor based on a polymer film. The application of this technology can be adapted to government as well as industrial uses. One such project is to make a chemical sensor for the detection of hazardous chemicals. The thin polymer film is highly suited for this purpose since a marker dye could be easily placed on the film in order to detect chemical compounds. This system could be a self-regulating chemical monitoring system used on launches of the space shuttle or locations where hazardous chemicals are present. The project provided support for two black minority graduate students targeting MS and PhD degrees in Applied Optics.

Adamovsky, Gregory↗

Characteristics of optically stimulated luminescence dosimeters in the spread-out Bragg peak region of clinical proton beams

Purpose: Optically stimulated luminescent detectors (OSLDs) have a number of advantages in radiation dosimetry making them excellent dosimeters for quality assurance and patient dose verification. Although the dosimeters have been investigated in several modalities, relatively little work has been done in examining the dosimeters for use in clinical proton beams. This study examined a number of characteristics of the response of the dosimeters in the spread-out Bragg peak (SOBP) region of clinical proton beams. Methods: Optically stimulated luminescence (OSL) dosimeters from Landauer, Inc., specifically the nanoDot dosimeter, were investigated. These dosimeters were placed in a special phantom with a recess to fit the dosimeters without an air gap. Beams with nominal energies of 160, 200, and 250 MeV were used in the passively-scattered proton beam at the MD Anderson Cancer Center Proton Therapy Center. Dosimetric properties including linearity, field size dependence, energy dependence, residual signal as a function of cumulative dose, and postirradiation fading were investigated by taking measurements at the center of SOBPs. Results: The dosimeters showed 1% supralinearity at 200 cGy and 5% supralinearity at 1000 cGy. No noticeable field size dependence of the detector was found for field sizes from 2 x 2 cm{sup 2} to 18 x 18 cm{sup 2}. Residual signal as a function of cumulative dose showed a small increase for measurements up to 1000 cGy. Readout signal depletion of the dosimeters after consecutive readings showed a slightly larger depletion in protons for doses up to 500 cGy but not by a clinically significant amount. Within the center of various SOBP widths and proton energies the variation in response was less than 2%. An average beam quality factor of 1.089 with experimental standard deviation of 0.007 was determined and applied to the data such that the results were within 1.2% of ion chamber data. Conclusions: The nanoDot OSL dosimeter characteristics were studied in the SOBP region of clinical proton beams. To achieve accurate dosimetric readings, corrections to the dosimeter response were applied. Corrections tended to be minimal or broadly consistent. The nanoDot OSLD was found to be an acceptable dosimeter for measurement in the SOBP region for a range of clinical proton beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effects of pointing errors on the performance of optical communications systems

Optical communications systems operating over interplanetary distances require the use of extremely narrow optical beams for maximum power concentration near the receiver. Consequently, pointing errors must be kept to a small fraction of a beamwidth to avoid severe deterioration in receiver performance, due to the decrease in received power associated with pointing errors. Mathematical moels required for studying the effects of random pointing errors were developed and applied to the problem of quantifying the effects of pointing errors on the performance of coherent and incoherent optical receivers.

Vilnrotter, V. A.↗

McMillan Lens in a System with Space Charge

Space charge (SC) in a circulating beam in a ring produces both betatron tune shift and betatron tune spread. These effects make some particles move on to a machine resonance and become unstable. Linear elements of beam optics cannot reduce the tune spread induced by SC because of its intrinsic nonlinear nature. We investigate the possibility to mitigate it by a thin McMillan lens providing a nonlinear axially symmetric kick, which is qualitatively opposite to the accumulated kick by SC. Experimentally, the proposed concept can be tested in Fermilab's IOTA ring. A thin McMillan lens can be implemented by a short (70 cm) insertion of an electron beam with specifically chosen density distribution in transverse directions. In this article, to see if McMillan lenses reduce the tune spread induced by SC, we make several simulations with particle tracking code Synergia. We choose such beam and lattice parameters that tune spread is roughly 0.5 and a beam instability due to the half-integer resonance 0.5 is observed. Then, we try to reduce emittance growth by shifting betatron tunes by adjusting quadrupoles and reducing the tune spread by McMillan lenses.

43 PARTICLE ACCELERATORS↗

Evanescent waves propagation along a periodically corrugated surface and their amplification by relativistic electron beam (quasi-optical theory)

By using a quasi-optical approach, we study propagation of evanescent waves along a periodically corrugated surface and their excitation by relativistic electron beams. Under assumption of a shallow (in the scale of period) corrugation, the dispersion equation for normal waves is derived and two particular cases are studied. In the first case, the wave frequency is far from the Bragg resonance; therefore, the evanescent wave propagation can be described by using the impedance approximation with deceleration of the zeroth spatial harmonic. The second case takes place at the frequencies close to the Bragg resonance. There, the field can be represented as two counter-propagating quasi-optical wave beams, which are coupled on the corrugated surface and form an evanescent normal wave. With regard to the interaction with an electron beam, the first case corresponds to the convective instability that can be used for amplification of radiation, while the second case corresponds to the absolute instability used in surface-wave oscillators. This paper is focused on studying main features of amplifier schemes, such as the increments, electron efficiency, and formation of a self-consistent spatial structure of the radiated field. For practical applications, the feasibility of realization of relativistic surface-wave amplifiers in the submillimeter wavelength range is estimated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coherent diffractive imaging with twisted X-rays: Principles, applications, and outlook

Recent technological breakthroughs in synchrotron and x-ray free electron laser facilities have revolutionized nanoscale structural and dynamic analyses in condensed matter systems. This review provides a comprehensive overview of the advancements in coherent scattering and diffractive imaging techniques, which are now at the forefront of exploring materials science complexities. These techniques, notably Bragg coherent diffractive imaging and x-ray photon correlation spectroscopy, x-ray magnetic dichroism, and x-ray correlation analysis leverage beam coherence to achieve volumetric three-dimensional imaging at unprecedented sub-nanometer resolutions and explore dynamic phenomena within sub-millisecond timeframes. Such capabilities are critical in understanding and developing advanced materials and technologies. Simultaneously, the emergence of chiral crystals—characterized by their unique absence of standard inversion, mirror, or other roto-inversion symmetries—presents both challenges and opportunities. These materials exhibit distinctive interactions with light, leading to phenomena such as molecular optical activity, chiral photonic waveguides, and valley-specific light emissions, which are pivotal in the burgeoning fields of photonic and spintronic devices. This review elucidates how novel x-ray probes can be leveraged to unravel these properties and their implications for future technological applications. A significant focus of this review is the exploration of new avenues in research, particularly the shift from conventional methods to more innovative approaches in studying these chiral materials. Inspired by structured optical beams, the potential of coherent scattering techniques utilizing twisted x-ray beams is examined. This promising direction not only offers higher spatial resolution but also opens the door to previously unattainable insights in materials science. By contextualizing these advancements within the broader scientific landscape and highlighting their practical applications, this review aims to chart a course for future research in this rapidly evolving field.

Physics↗