SU-E-T-116: Analysis of Patient Specific VMAT QA Passing Rates with Delta4 for Matched Machines

Purpose: To test whether unified vendor specified beam conformance for matched machines implies volumetric modulated arc radiotherapy(VMAT) delivery consistency. Methods: Twenty-two identical patient QA plans, eleven 6MV and eleven 15MV, were delivered to the Delta{sup 4}(Scandidos, Uppsala, Sweden) on two Varian TrueBEAM matched machines. Sixteen patient QA plans, nine 6 MV and seven 10 MV, were delivered to Delta{sup 4} on two Elekta Agility matched machines. The percent dose deviation(%DDev), distance-to-agreement(DTA), and the gamma analysis(γ) were collected for all plans and the differences in measurements were tabulated between matched machines. A paired t-test analysis of the data with an alpha of 0.05 determines statistical significance. Power(P) was calculated to detect a difference of 5%; all data except Elekta %DDev sets were strong with above a 0.85 power. Results: The average differences for Varian machines (%DDev, DTA, and γ) are 6.4%, 1.6% and 2.7% for 6MV, respectively, and 8.0%, 0.6%, and 2.5% for 15MV. The average differences for matched Elekta machines (%DDev, DTA, and γ) are 10.2%, 0.6% and 0.9% for 6 MV, respectively, and 7.0%, 1.9%, and 2.8% for 10MV.A paired t-test shows for Varian the %DDev difference is significant for 6MV and 15MV(p-value6MV=0.019, P6MV=0.96; p-value15MV=0.0003, P15MV=0.86). Differences in DTA are insignificant for both 6MV and 15MV(p-value6MV=0.063, P6MV=1; p-value15MV=0.907, P15MV=1). Varian differences in gamma are significant for both energies(p-value6MV=0.025, P6MV=0.99; p-value15MV=0.013, P15MV=1). A paired t-test shows for Elekta the difference in %DDev is significant for 6MV but not 10MV(p-value6MV=0.00065, P6MV=0.68; p-value10MV=0.262, P10MV=0.39). Differences in DTA are statistically insignificant(p-value6MV=0.803, P6MV = 1; p-value10MV=0.269, P10MV=1). Elekta differences in gamma are significant for 10MV only(p-value6MV=0.094, P6MV=1; p-value10MV=0.011, P10MV=1). Conclusion: These results show vendor specified beam conformance across machines does not ensure equivalent patient specific QA pass rates. Gamma differences are statistically significant in three of the four comparisons for two pairs of vendor matched machines.

60 APPLIED LIFE SCIENCES↗

SU-E-T-269: Differential Hazard Analysis For Conventional And New Linac Acceptance Testing Procedures

Purpose: New techniques and materials have recently been developed to expedite the conventional Linac Acceptance Testing Procedure (ATP). The new ATP method uses the Electronic Portal Imaging Device (EPID) for data collection and is presented separately. This new procedure is meant to be more efficient then conventional methods. While not clinically implemented yet, a prospective risk assessment is warranted for any new techniques. The purpose of this work is to investigate the risks and establish the pros and cons between the conventional approach and the new ATP method. Methods: ATP tests that were modified and performed with the EPID were analyzed. Five domain experts (Medical Physicists) comprised the core analysis team. Ranking scales were adopted from previous publications related to TG 100. The number of failure pathways for each ATP test procedure were compared as well as the number of risk priority numbers (RPN’s) greater than 100 were compared. Results: There were fewer failure pathways with the new ATP compared to the conventional, 262 and 556, respectively. There were fewer RPN’s > 100 in the new ATP compared to the conventional, 41 and 115. Failure pathways and RPN’s > 100 for individual ATP tests on average were 2 and 3.5 times higher in the conventional ATP compared to the new, respectively. The pixel sensitivity map of the EPID was identified as a key hazard to the new ATP procedure with an RPN of 288 for verifying beam parameters. Conclusion: The significant decrease in failure pathways and RPN’s >100 for the new ATP mitigates the possibilities of a catastrophic error occurring. The Pixel Sensitivity Map determining the response and inherent characteristics of the EPID is crucial as all data and hence results are dependent on that process. Grant from Varian Medical Systems Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-T-273: Do Task Group External Beam QA Recommendations Guarantee Accurate Treatment Plan Dose Delivery?

Purpose: AAPM task groups 40/142 have provided an invaluable set of goals for physicists designing QA programs, attempting to standardize what would otherwise likely be a highly variable phenomenon across institutions. However, with the complexity of modalities such as VMAT, we hypothesize that following these guidelines to the letter might still allow unacceptable dose discrepancies. To explore this hypothesis we simulated machines bordering on QA acceptability, and calculated the effect on patient plans. Methods: Two errant machines were simulated in Aria/Eclipse, each just within task group criteria for output, percent depth dose, beam profile, gantry and collimator rotations, and jaw and MLC positions. One machine minimized dose to the PTV (machine A) and the other maximized dose to the OARs (machine B). Clinical treatment plans (3-phase prostate, n=3; hypofractionated lung, n=1) were calculated on these machines and the dose distributions compared. A prostate case was examined for contribution of error sources and evaluated using delivery QA data. Results: The prostate plans showed mean decreases in target D95 of 9.9% of prescription dose on machine A. On machine B, The rectal and bladder V70Gy each increased by 7.1 percentage points, while their V45Gy increased by 16.2% and 15.0% respectively. In the lung plan, the target D95 decreased by 12.8% and the bronchial tree Dmax increased by 21% of prescription dose, on machines A and B. One prostate plan showed target dose errors of 3.8% from MLC changes, 2% from output, ∼3% from energy and ∼0.5% from other factors. This plan achieved an 88.4% gamma passing rate using 3%/3mm using ArcCHECK. Conclusion: In the unlikely event that a machine exhibits all maximum errors allowed by TG 40/142, unacceptably large changes in dose delivered are possible especially in highly modulated VMAT plans, despite the machine passing routine QA.

60 APPLIED LIFE SCIENCES↗

Synchrotron Radiation Beam Diagnostics for the Integrable Optics Test Accelerator

The Integrable Optics Test Accelerator (IOTA) is a research electron and proton storage ring currently being commissioned at Fermilab's Accelerator Science and Technology (FAST) facility. An extensive beam physics research program is planned, including tests of novel techniques for improving beam intensity, stability, and emittance. A key part of IOTA beam diagnostics suite are synchrotron light beam monitors, mounted onto each dipole. In this paper, we present the hardware and software design of this system. Mechanical layout and actuator control electronics are described. High throughput image acquisition and analysis architecture is outlined, and its preliminary performance is explored. Integration of the system within accelerator control network and possible user applications, such as camera auto-focusing, are discussed.

43 PARTICLE ACCELERATORS↗

Run 16, eIPM Summary

Three problems with the eIPMs were corrected during the 2015 summer shutdown. These involved ac coupling and 'negative profiles', detector 'dead zone' created by biasing, and gain control on ramp. With respect to Run 16, problems dealt with included gain depletion on horizontal MCP and rf pickup on profile signals; it was found that the MCP was severely damaged over part of the aperture. Various corrective measures were applied. Some results of these measured obtained during Run 16 are shown. At the end of Run 16 there was a three-­day beam run to study polarized proton beams in the AGS. Attempts to minimize beam injection errors which increase emittance by using the eIPMs to measure the contribution of injection mismatch to the AGS output beam emittance are recounted. .

43 PARTICLE ACCELERATORS↗

Collider Physics Instrumentation

We are developing new technologies for particle tracking. These include 3D silicon sensors and devices for calibration and dosimetry in the HL-LHC fluence regime. We collaborate in the development of a new model for radiation damage in silicon - this is immediately relevant to extrapolations about the future of LHC tracker hardware. We lead radiation damage campaigns on behalf of many collaborating LHC institutes as well as ourselves, and we apply the results of these to development of new techniques for particle beam monitoring and operation of silicon detectors in variable environmental conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultimate Precision on Sin^2 Theta_23 With the Numi Experiments

There were two major goals to this proposal: the study of the discrepancy between data and MC in the NuMI Medium Energy neutrino beam and the incorporation of the MINOS and NOVA neutrino oscillation datasets. The first topic was approached via development of a simulation of the NuMI beam monitoring instrumentation suite. Initially, the Horn-Off current data sets were used to measure a set of hadron production parameters which improved the data/MC agreement in a way which was independent of the focusing parameters. The peak position discrepancy was only explained by a large (10kA) reduction in the horn current. A full simulation of the muon monitors was developed to attempt to make an independent measurement of the horn current by means of differential data taken by those monitors. While only at the 5kA level, the result corroborated the former findings. The second goal has not yet been completed but progress has focused on understanding how to modify the MINOS MC to take into account the MEC contribution which is missing from the underlying NEUGEN MC. A number of improvements to the MINOS reconstruction have been necessary. The framework to run the fits on the combined data has been completed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detector needs for STS instruments

This white paper contains an analysis of the requirements for the detectors for the initial suite of neutron scattering instruments at the Second Target Station, STS. The detector technologies proposed are compared with the instrument requirements, in-house proficiencies and strengths, and where appropriate, expertise at other facilities. Where relevant, alternative detector options are proposed. The performance gaps between the current state-of-the-art and the required characteristics are identified and projects within the R&D program are proposed in order to close these gaps. Further, neutron beam monitor needs are considered in a similar light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel Simulation of Beam Dynamics in Particle Accelerators [Slides]

Particle accelerators are among the most versatile and important tools of scientific discovery. The Nation's accelerators are responsible for a wealth of advances in materials science, chemistry, the biosciences, particle physics, and nuclear physics. They also have important applications to national security, the environment, energy, medicine, and on the quality of people's lives. LANL has a long history of making pioneering contributions to Accelerator Science including key contributions to the field of Computational Accelerator Physics. These include the development of early beam dynamics codes with space charge (such as PARMILA and PARMELA), the development of rf cavity codes and magnet codes (including Poisson and Superfish), and the development and distribution of codes to the accelerator community through the Los Alamos Accelerator Code Group. LANL researchers also helped pioneer the development of massively parallel space-charge codes. In project t22_accelsim we have moved beyond electrostatic models of collective effects (i.e., solving the Poisson equation in the bunch frame) to fully electromagnetic models based on the Lienard-Wiechert formalism. This approach enables the large-scale simulation of radiation production and collective effects in high brightness electron beams. This is highly relevant to LANL given its future goal of developing an X-ray Free Electron Laser (XFEL). It also directly impacts a LANL LDRD project to develop an undulator-based non-invasive beam profile monitor for beams created in laser-plasma accelerator systems.

43 PARTICLE ACCELERATORS↗

The SAND detector for the DUNE experiment

The Deep Underground Neutrino Experiment (DUNE) is a next-generation project aiming to study several neutrino properties. It will feature two experimental setups: a near detector that will be installed at Fermilab, in proximity of the neutrino-production point, and a far detector at a distance of 1300 km and 1500 m underground, at the SURF laboratory. The DUNE design and configuration will allow the study of neutrino oscillation, astrophysical neutrinos, and beyond standard model physics. The near detector complex foresees three detectors to be installed. Among these, the System for on-Axis Neutrino Detection (SAND) will serve as on-axis beam monitor, reduce the systematic uncertainties for the oscillation analysis, and search for physics beyond the standard model. SAND will be composed of three sub-detectors, surrounded by a 0.6 T superconducting magnet. The outermost detector will be a lead/scintillating-fiber electromagnetic calorimeter while the inner volume will include a 1-ton liquid argon active target placed upstream followed by a target tracker system. The SAND detector and its goals will be shown in this poster.

Alemanno, Francesca [Salento U.; INFN, Lecce]↗

R_transport_matrices of the Fast Extraction Beam (FEB) of the AGS, and Beam Parameters at the Starting point of the AtR Line

As part of the task to improve and further automate the 'AtR BPM Application' we provide the theoretically calculated R-transport-matrices for the following beam line sections, which are shown schematically in Figure 1: (a) the Fast Extraction Beam section (FEB) of the AGS synchrotron. The FEB section starts at the middle of the GlO-kicker and ends at the middle of the H1 0{_}septum. (b) the Drift Extraction Channel (DEC) section of the AGS synchrotron. The DEC section starts at the middle of the H10{_}septum, continues along the fringe field region of the H11,H12, and H13 AGS main magnets, and ends at the starting point of the AtR line. The knowledge of these R-transport-matrices are needed in order to calculate the beam parameters at the beginning of the AtR line, which in turn, are required to calculate the magnet settings of the U{_}line, that match the U{_}line into the W{_}line. Also by incorporating these R{_}matrices into the model of the AtR line, the G10 kicker and the H10 septum are included in the AtR model therefore one can investigate any 'jitter' of either the GlO{_}kicker or HlO{_}septum by looking at the trajectory of the beam in the AtR line.

43 PARTICLE ACCELERATORS↗

Estimate of Undulator Magnet Damage Due to Beam Finder Wire Measurements

Beam Finder Wire (BFW) devices will be installed at each break in the Undulator magnet line. These devices will scan small wires across the beam causing some electrons to lose energy through bremsstrahlung. The degraded electrons are subsequently detected downstream of a set of vertical dipole magnets after they pass through the vacuum chamber. This signal can then be used to accurately determine the beam position with respect to the BFW wire. The choice of the wire diameter, scan speed, and operating parameters, depends on the trade-off between the signal size and the radiation damage to the undulator magnets. In this note I estimate the rate of undulator magnet damage that results from scanning as a function of, wire size, scan speed, and average beam current. A separate analysis of the signal size was carried out by Wu. The damage estimate is primarily based on two sources: the first, Fasso, is used to estimate the amount of radiation generated and then absorbed by the magnets; the second, Alderman et. al., is used to estimate the amount of damage the magnet undergoes as a result of the absorbed radiation. Fasso performed a detailed calculation of the radiation, including neutron fluence, that results from a the electron beam passing through a 100 micron diamond foil inserted just in front of the undulator line. Fasso discussed the signficance of various types of radiation and stated that photoneutrons probably play a major role. The estimate in this paper assumes the neutron fluence is the only significant cause of radiation-induced demagnetization. The specific results I use from Fasso's paper are reproduced here in Figure 1, which shows the radial distribution of the integrated neutron fluence per day in the undulator magnets, and Figure 2, which shows the absorbed radiation dose all along the undulator line. In the longitudinal dimension, Fasso's calculation, (see Figure 2), shows that the radiation dose is widely distributed all along the undulator line, but is highest around 70 m from the front of the undulator line where the foil is. At the 70 m point, for the purpose of calculating the demagnetization, I chose a conservative estimate for the effective neutron flux of 1.0 x 10{sup 13} n/cm{sup 2}/day. As can be seen in Figure 1, this choice is representative of the flux nearest the beam where it is the highest. A less conservative estimate, but perhaps more accurate, estimate of the effective flux, would be the average flux in the magnet block, which is roughly one half as much.

43 PARTICLE ACCELERATORS↗

Commissioning a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of the quadrupoles. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing such a system. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). A previous study investigated the error associated with each step by using a permanent quadrupole magnet on an optical mover system. The study reported an error of 11{micro}m for step 1 and a repeatability of 4{micro}m for step 2. However, the set up used a FARO arm to measure tooling balls and didn't allow to accurately check step 2 for errors; an uncertainty of 100{micro}m was reported. Therefore, even though the repeatability was good, there was no way to check that the error in step 2 was small. Following the recommendations of that study, we used a CMM (Coordinate Measuring Machine) instead of the FARO arm for measuring the tooling balls. In addition, a roller cam positioner system replaced the optical movers for moving the quadrupole. With the exception of the quadrupole itself, the system was identical to what will be used in fiducializing the undulator quadrupoles. In this study, we investigate the new vibrating wire set up, including the error associated with each step of fiducialization. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note is a continuation of previous work to study the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Summary of QM02 Measurements

This note summarizes both the beam-based and various laboratory measurements of quadrupole magnets, units 387 and 428, used for QM02 in the LCLS Injector. These were undertaken because of a consistent discrepancy between accelerator model predictions and beam observations which seemed to indicate a weak QM02. A report 'QM02 Strength Measurement', by Welch and Wu, describes the discrepancy and beam-based measurements on unit 387. Subsequently, unit 387 was replaced by unit 428, refinements were made to analysis of the beam-based measurements were made, and additional magnetic measurements were made on unit 387 in the lab. These new results are summarized in this note. The principle results are: (1) Laboratory measurements of integrated gradient for the same magnet, or for different magnets of the same type, are all within 1% of each other at gradients of interest. These cases cover three independent types of measurements, disassembly/reassembly of the units, and extended periods of time between measurements. (2) Standardization, or lack thereof, can cause integrated gradient errors of approximately 0.2 kG, which can amount to a few percent of the strength of the magnet depending on the setting. (3) Model-independent beam-based measurements indicate the magnets are actually weaker than expected by about 2 percent, but these measurements are subject to the uncertainty of the BPMS1 location. (4) The standardization cycle is effective. (5) The stainless steel BPM vacuum chamber inside the magnets has no significant effect on the beam. The discrepancy between the accelerator model predictions and the actual orbit response is not resolved, but the evidence points away from magnetic strength errors as the source. Differences between the model locations and effective locations of BPM's is a possible culprit. This idea is explored in Section 2. Table 1 summarizes the measurement activities that were performed on the units. The dates listed correspond to the date when the relevent series of runs was completed.

43 PARTICLE ACCELERATORS↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

The System for on-Axis Neutrino Detection at the DUNE Near Detector complex

The Deep Underground Neutrino Experiment Near Detector complex aims at constraining the systematic uncertainties and deconvolving the neutrino beam flux and cross-section models. The System for on-Axis Neutrino Detection (SAND) is the Near Detector component permanently on-axis. SAND is based on the 0.6 T superconducting magnet and electromagnetic calorimeter previously used in the KLOE experiment. The 40 m3 magnetic volume will be filled with an active target/tracker system. One considered option foresees an upstream liquid Argon active target (about 1.5 t) and a Straw Tube Tracker (about 5 t). In this talk the design of SAND will be described and its performances discussed in view of the SAND primary goals, namely the beam monitoring and neutrino flux measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗