Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Towards a neutron multiplicity measurement with the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26 ton Gadolinium (Gd)-loaded water Cherenkov detector located on the Booster Neutrino Beam line at Fermilab. Its main goals are the measurement of the neutron multiplicity in neutrino-nucleus interactions as well as the cross-section of Charged Current Quasi-Elastic (CCQE) neutrino interactions on water. Besides the physics goals, the experiment also aims to be a testbed for new technologies such as Large Area Picosecond Photodetectors (LAPPDs) and Water-based Liquid Scintillators (WbLS). This thesis presents a preliminary measurement of the neutron multiplicity with {ANNIE}, using an analysis conducted on a fraction of the 2021 beam year. As preparatory measures, the efficiency of ANNIE's Front Muon Veto (FMV) was determined to be {$\bar{\varepsilon}_{\mathrm{FMV}} = (95.6 \pm 1.6)\%$} while the average efficiency for active scintillator paddles in the Muon Range Detector (MRD) was found to be {$\bar{\varepsilon}_ {\mathrm{MRD}} = (92.1 \pm 7.9)\%$}. Furthermore, the simulation framework used for ANNIE was validated and adapted to reproduce the experimental data by comparing the detector response for samples of Michel electrons, Americium Beryllium neutrons, and through-going muons. The analysis finds average neutron yields of {$\bar{n}_{\mathrm{data}} (\mathrm{beam}) = (0.272 \pm 0.010_{\mathrm{stat}})$} for an inclusive set of all identified muon neutrino candidates and {$\bar{n}_{\mathrm{data}} (\mathrm{beam,FV}) = (0.287 \pm 0.044_{\mathrm{stat}})$ for interactions which happened inside of the Fiducial Volume of ANNIE, which was optimized to increase the neutron detection acceptance. The presented neutron multiplicity values represent the number of detected neutrons after all event selection cuts and are not yet corrected for the neutron detection efficiency. An equivalent analysis on a simulated beam sample predicts neutron yields of $\bar{n}_{\mathrm{MC}}(\mathrm{beam}) = (0.515 \pm 0.0 07_{\mathrm{stat}})$ and $\bar{n}_{\mathrm{MC}}(\mathrm{beam,FV}) = (0.627 \pm 0.031_{\mathrm{stat}})$, indicating that the models tend to overpredict the number of neutrons produced in such interactions. Systematic errors have been briefly considered to contribute {$\sigma_{\mathrm{sys,FMV}} \sim 0.01\,$neutrons/$\nu$-interaction} due to the slight FMV inefficiency and {$\sigma_{\mathrm{sys,n}} \sim 0.05\,$neutrons/$\nu$-interaction} due to the neutron detection efficiency. Simulation studies further highlighted the importance of neutron detection in Diffuse Supernova Background (DSNB) searches. A combination of neutron tagging and Convolutional Neural Networks was found to reduce the most relevant Neutral Current Quasi-Elastic (NCQE) interaction background below the signal level, achieving a Signal-to-Background ratio of 4:1. In a further study, we investigated the positive impact of a deployment of a WbLS target on the energy reconstruction in ANNIE. WbLS provides a scintillation signal from hadronic recoils in addition to the charged lepton that can be included in neutrino energy reconstruction. It was found that a deployed WbLS volume in ANNIE improves the neutrino energy reconstruction from 14\% to 12\%, with the potential of going beyond this if more sophisticated reconstruction algorithms are developed in the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Reference Field for GCR Simulation and an LET-Based Implementation at NSRL

Exposure to galactic cosmic rays (GCR) on long duration deep space missions presents a serious health risk to astronauts, with large uncertainties connected to the biological response. In order to reduce the uncertainties and gain understanding about the basic mechanisms through which space radiation initiates cancer and other endpoints, radiobiology experiments are performed. Some of the accelerator facilities supporting such experiments have matured to a point where simulating the broad range of particles and energies characteristic of the GCR environment in a single experiment is feasible from a technology, usage, and cost perspective. In this work, several aspects of simulating the GCR environment in the laboratory are discussed. First, comparisons are made between direct simulation of the external, free space GCR field and simulation of the induced tissue field behind shielding. It is found that upper energy constraints at the NASA Space Radiation Laboratory (NSRL) limit the ability to simulate the external, free space field directly (i.e. shielding placed in the beam line in front of a biological target and exposed to a free space spectrum). Second, variation in the induced tissue field associated with shielding configuration and solar activity is addressed. It is found that the observed variation is within physical uncertainties, allowing a single reference field for deep space missions to be defined. Third, an approach for simulating the reference field at NSRL is presented. The approach allows for the linear energy transfer (LET) spectrum of the reference field to be approximately represented with discrete ion and energy beams and implicitly maintains a reasonably accurate charge spectrum (or, average quality factor). Drawbacks of the proposed methodology are discussed and weighed against alternative simulation strategies. The neutron component and track structure characteristics of the proposed strategy are discussed in this context.

Slaba, Tony C.↗

MicroBooNE Electron Neutrino Cross Sections without Visible Pions

MicroBooNE is an 85-tonne liquid argon time projection chamber (LArTPC) at Fermilab. It collected data from two different beam lines between 2015 and 2020 and has since released a large number of neutrino cross section results on argon. These inform neutrino interaction modelling in view of next generation LArTPCs such as the upcoming DUNE experiment. We present new measurements of the electron neutrino charged current pionless cross section on argon in the MicroBooNE detector. These measurements are essential to DUNE’s oscillation analysis as they impact the predicted interaction rate of the main flavor appearance signal. Two measurements are presented, one that leverages the full on-axis MicroBooNE Booster Neutrino Beam dataset while the other uses about 30% of the 8° off-axis Neutrino at the Main Injector beam dataset. Two channels can be considered: with or without a visible pion in the final state. Both measurements consider events with visible protons and the BNB measurement also measures electron neutrinos across the proton visibility threshold. Differential cross sections are extracted in proton and electron kinematics. The relationship between the hadronic and leptonic systems is explored through the angle between the proton and electron directions. The resulting cross sections are compared to a variety of generator predictions using different models of neutrino interactions. We find overall good agreement with most models, especially in lepton kinematics.

Mellet, Lucile [Michigan State U.]↗

Application of X-ray synchrotron microscopy instrumentation in biology

X-ray micro-fluorescence imaging technique has been used as a significant tool in order to investigate minerals contents in some kinds of materials. The aim of this study was to evaluate the elemental distribution of calcium and zinc in bone substitute materials (nano-hydroxyapatite spheres) and cortical bones through X-Ray Micro-fluorescence analysis with the increment of Synchrotron Radiation in order to evaluate the characteristics of the newly formed bone and its interface, the preexisting bone and biomaterials by the arrangement of collagen fibers and its birefringence. The elemental mapping was carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo, Brazil working at D09-XRF beam line. Based on this study, the results suggest that hydroxyapatite-based biomaterials are biocompatible, promote osteo-conduction and favored bone repair. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ERL with non-scaling fixed field alternating gradient lattice for eRHIC

The proposed eRHIC electron-hadron collider uses a "non-scaling FFAG" (NS-FFAG) lattice to recirculate 16 turns of different energy through just two beam lines located in the RHIC tunnel. This paper presents lattices for these two FFAGs that are optimized for low magnet field and to minimize total synchrotron radiation across the energy range. The higher number of recirculations in the FFAG allows a shorter linac (1.322GeV) to be used, drastically reducing cost, while still achieving a 21.2 GeV maximum energy to collide with one of the existing RHIC hadron rings at up to 250GeV. eRHIC uses many cost-saving measures in addition to the FFAG: the linac operates in energy recovery mode, so the beams also decelerate via the same FFAG loops and energy is recovered from the interacted beam. All magnets will be constructed from NdFeB permanent magnet material, meaning chillers and large magnet power supplies are not needed. This paper also describes a small prototype ERL-FFAG accelerator that will test all of these technologies in combination to reduce technical risk for eRHIC.

43 PARTICLE ACCELERATORS↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energetic particles in spherical tokamak plasmas

Spherical tokamaks (STs) typically have lower magnetic fields than conventional tokamaks, but similar mass densities. Suprathermal ions with relatively modest energies, in particular beam-injected ions, consequently have speeds close to or exceeding the Alfvén velocity, and can therefore excite a range of Alfvénic instabilities which could be driven by (and affect the behaviour of) fusion α-particles in a burning plasma. STs heated with neutral beams, including the small tight aspect ratio tokamak (START), the mega amp spherical tokamak (MAST), the national spherical torus experiment (NSTX) and Globus-M, have thus provided an opportunity to study toroidal Alfvén eigenmodes (TAEs), together with higher frequency global Alfvén eigenmodes (GAEs) and compressional Alfvén eigenmodes (CAEs), which could affect beam current drive and channel fast ion energy into bulk ions in future devices. In NSTX GAEs were correlated with a degradation of core electron energy confinement. In MAST pulses with reduced magnetic field, CAEs were excited across a wide range of frequencies, extending to the ion cyclotron range, but were suppressed when hydrogen was introduced to the deuterium plasma, apparently due to mode conversion at ion–ion hybrid resonances. At lower frequencies fishbone instabilities caused fast particle redistribution in some MAST and NSTX pulses, but this could be avoided by moving the neutral beam line away from the magnetic axis or by operating the plasma at either high density or elevated safety factor. Fast ion redistribution has been observed during GAE avalanches on NSTX, while in both NSTX and MAST fast ions were transported by saturated kink modes, sawtooth crashes, resonant magnetic perturbations and TAEs. The energy dependence of fast ion redistribution due to both sawteeth and TAEs has been studied in Globus-M. High energy charged fusion products are unconfined in present-day STs, but have been shown in MAST to provide a useful diagnostic of beam ion behaviour, supplementing the information provided by neutron detectors. In MAST electrons were accelerated to highly suprathermal energies as a result of edge localised modes, while in both MAST and NSTX ions were accelerated due to internal reconnection events. Lastly, ion acceleration has also been observed during merging-compression start-up in MAST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Transverse Shielding Analysis for the 1010-C RF Building

EIC is planning to construct a new building on the outer ring berm at 10 o’clock which will provide RF power to cryogenically-cooled beam line components in the electron and hadron storage rings. The distance of the building from the RHIC Tunnel and the amount of soil shielding required are the focus of this report. Siting the building closer to the RHIC Tunnel is desirable from an RF operations viewpoint since the waveguide runs and RF power losses will be minimized, but this may require the use of higher density shield materials, e.g., concrete, in addition to soil shielding. The radiological source terms are the prompt radiation hazards from the Hadron Storage Ring (HSR) and Electron Storage Ring (ESR) beam losses in the 10 o’clock sector and the lateral dose rates propagated through the shields. See Figure 1 below.

43 PARTICLE ACCELERATORS↗

Correlations of trace elements in breast human tissues: Evaluation of spatial distribution using {mu}-XRF

The aim of this work is to investigate microscopic correlations between trace elements in breast human tissues. A synchrotron X-ray fluorescence microprobe system ({mu}-XRF) was used to obtain two-dimensional distribution of trace element Ca, Fe, Cu and Zn in normal (6 samples) and malignant (14 samples) breast tissues. The experiment was performed in X-ray Fluorescence beam line at Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, Brazil. The white microbeam was generated with a fine conical capillary with a 20 {mu}m output diameter. The samples were supported on a XYZ table. An optical microscope with motorized zoom was used for sample positioning and choice the area to be scanned. Automatic two-dimensional scans were programmed and performed with steps of 30 {mu}m in each direction (x, y) on the selected area. The fluorescence signals were recorded using a Si(Li) detector, positioned at 90 degrees with respect to the incident beam, with a collection time of 10 s per point. The elemental maps obtained from each sample were overlap to observe correlation between trace elements. Qualitative results showed that the pairs of elements Ca-Zn and Fe-Cu could to be correlated in malignant breast tissues. Quantitative results, achieved by Spearman correlation tests, indicate that there is a spatial correlation between these pairs of elements (p < 0.001) suggesting the importance of these elements in metabolic processes associated with the development of the tumor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On LBNE neutrino flux systematic uncertainties

The systematic uncertainties in the neutrino flux of the Long-Baseline Neutrino Experiment, due to alignment uncertanties and tolerances of the neutrino beamline components, are estimated. In particular residual systematics are evaluated in the determination of the neutrino flux at the far detector, assuming that the experiment will be equipped with a near detector with the same target material of the far detector, thereby canceling most of the uncertainties from hadroproduction and neutrino cross sections. This calculation is based on a detailed Geant4-based model of the neutrino beam line that includes the target, two focusing horns, the decay pipe and ancillary items, such as shielding.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-FG-BRA-04: A Portable Confocal Microscope to Image Live Cell Damage Response Induced by Therapeutic Radiation

Purpose: To construct a custom and portable fluorescence confocal laser-scanning microscope (FCLSM) that can be placed in the path of therapeutic radiation beams to study real-time radiation-induced damage response in live cells. Methods: We designed and constructed a portable FCLSM with three laser diodes for excitation (405, 488, and 635 nm). An objective lens focuses the excitation light and collects fluorescence from the sample. A pair of galvanometer mirrors scans/collects the laser beam/fluorescence along the focal plane (x/y-directions). A stepper motor stage scans in the axial direction and positions the x/y of the image field. Barrier filters and dichroic mirrors are used to route the spectral emission bands to the appropriate photodetector. An avalanche photodiode collects near-infrared fluorescence; a photodiode collects back-reflected 635 nm light; and a photomultiplier tube collects green fluorescence in the range of eGFP/eYFP. A 200-µm diameter pinhole was used to implement the confocal geometry for near-infrared and red channels and a 150-µm diameter pinhole for the green channel. Data acquisition and system control were achieved using a high-throughput data acquisition card. In-house software developed in LabVIEW was used to control the hardware, collect data from the photodetectors and reconstruct the confocal images. Results: 6 frames/s can be acquired for a 25 µm{sup 2} (128×128 pixels) field of view, visualizing the entire volume of the cell nucleus (∼10 µm depth) in <10 s. To demonstrate the usefulness of our FCLSM, we imaged gold nanoshells in live cells, radiation-induced damage in fibrosarcoma cells expressing eGFP tagged to a DNA repair protein, and neurons expressing eGFP. The system can also image particle tracks in fluorescent nuclear track detectors. Conclusion: We developed a versatile and portable FCLSM that allows radiobiology studies in live cells exposed to therapeutic radiation. The FCLSM can be placed in any vertical beam line for top-to-bottom exposures. This research was supported by the Sister Institution Network Fund and the Center for Radiation Oncology Research at The University of Texas MD Anderson Cancer Center and Cancer Prevention and Research Institute of Texas. Gabriel Sawakuchi has research support from Elekta Inc.

60 APPLIED LIFE SCIENCES↗

NuMI Graphite Target Fin Removal Assembly

Materials scientists want to study the irradiated graphite target from the Neutrino at the Main Injector (NuMI) beam line. In order to gather these irradiated graphite fins from the target canister, it will have to be done remotely. Therefore, a removal assembly will need to be created in order to do this efficiently and well. This project aims to make progressive steps towards deploying the final target removal assembly. Furthermore, calculations related to the removal assembly design were done, and tests were planned to discover further information about the feasibility of this design. The main result from this project is the deflection of the cantilever arm, which is 0.354 inches due to the weight of the beam and cutting tool. Additionally, more results of this project are the testing assembly CAD model and the feasibility of design. This project concludes that there is still more work that needs to be done for the removal assembly to be deployed, but there were foundational steps that were made in the implementation of this design. Finally, there should be further steps and tests to determine the feasibility of this removal assembly.

Malovski, Azra [NIU, DeKalb]↗

NuMI Graphite Target Fin Removal Assembly

Materials scientists want to study the irradiated graphite target from the Neutrino at the Main Injector (NuMI) beam line. In order to gather these irradiated graphite fins from the target canister, it will have to be done remotely. Therefore, a removal assembly will need to be created in order to do this efficiently and well. This project aims to make progressive steps towards deploying the final target removal assembly. Furthermore, calculations related to the removal assembly design were done, and tests were planned to discover further information about the feasibility of this design. The main result from this project is the deflection of the cantilever arm, which is 0.354 inches due to the weight of the beam and cutting tool. Additionally, more results of this project are the testing assembly CAD model and the feasibility of design. This project concludes that there is still more work that needs to be done for the removal assembly to be deployed, but there were foundational steps that were made in the implementation of this design. Finally, there should be further steps and tests to determine the feasibility of this removal assembly.

Malovski, Azra [NIU, DeKalb]↗

Plasma immersion ion implantation for sub-22 nm node devices: FD-SOI and Tri-Gate

Here, we present and discuss the electrical characteristics of fully depleted MOSFET transistors of planar and tridimensional architecture, doped by Plasma Immersion Ion Implantation (PIII) or Beam Line Ion Implantation (BLII). Both techniques delivered similar and satisfactory results in considering the planar architecture. For tri-dimensional Tri-Gate transistors, the results obtained with PIII are superior.

36 MATERIALS SCIENCE↗

Emittance and Phase Space Exchange for Advanced Beam Manipulation and Diagnostics

Alternative chicane-type beam lines are proposed for exact emittance exchange between transverse phase space (x,x') and longitudinal phase space (z,{delta}), where x is the transverse position, x' is the transverse divergence, and z and {delta} are relative longitudinal position and energy deviation with respect to the reference particle. Methods to achieve exact phase space exchanges, i.e., mapping x to z, x' to {delta}, z to x, and {delta} to x', are suggested. Schemes to mitigate and completely compensate for the thick-lens effect of the transverse cavity on emittance exchange are studied. Some applications of the phase space exchange for advanced beam manipulation and diagnostics are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical simulation of ion charge breeding in electron beam ion source

The Electron Beam Ion Source particle-in-cell code (EBIS-PIC) tracks ions in an EBIS electron beam while updating electric potential self-consistently and atomic processes by the Monte Carlo method. Recent improvements to the code are reported in this paper. The ionization module has been improved by using experimental ionization energies and shell effects. The acceptance of injected ions and the emittance of extracted ion beam are calculated by extending EBIS-PIC to the beam line transport region. An EBIS-PIC simulation is performed for a Cs charge-breeding experiment at BNL. The charge state distribution agrees well with experiments, and additional simulation results of radial profiles and velocity space distributions of the trapped ions are presented.

43 PARTICLE ACCELERATORS↗

Simulations of Ion Migration in the LCLS RF Gun and Injector

The motivation for this work was the observed surface contamination of the first LCLS RF gun copper cathode. We will present the results of simulations in regards to ion migration in the LCLS gun. Ions of residual gases will be created by interaction of molecular gas species with the UV drive laser beam and by the electron beam itself. The larger part of those ionized molecules remain in the vicinity of creation, are transported towards beam line walls or away from the cathode. However a small fraction gains enough kinetic energy, focused by RF and magnetic fields and propagates to the cathode, producing an undesirable increase of the cathode's surface work function. Although this fraction is small, during long term operation, this effect may become a significant factor limiting the source performance.

43 PARTICLE ACCELERATORS↗

SU-F-T-163: Improve Proton Therapy Efficiency: Report of a Workshop

Purpose: The technology of proton therapy, especially the pencil beam scanning technique, is evolving very quickly. However, the efficiency of proton therapy seems to lag behind conventional photon therapy. The purpose of the abstract is to report on the findings of a workshop on improvement of QA, planning and treatment efficiency in proton therapy. Methods: A panel of physicists, clinicians, and vendor representatives from over 18 institutions in the United States and internationally were convened in Knoxville, Tennessee in November, 2015. The panel discussed several topics on how to improve proton therapy efficiency, including 1) lean principle and failure mode and effects analysis, 2) commissioning and machine QA, 3) treatment planning, optimization and evaluation, 4) patient positioning and IGRT, 5) vendor liaison and machine availability, and 6) staffing, education and training. Results: The relative time needed for machine QA, treatment planning & check in proton therapy was found to range from 1 to 2.5 times of that in photon therapy. Current status in proton QA, planning and treatment was assessed. Key areas for efficiency improvement, such as elimination of unnecessary QA items or steps and development of efficient software or hardware tools, were identified. A white paper to summarize our findings is being written. Conclusion: It is critical to improve efficiency by developing reliable proton beam lines, efficient software tools on treatment planning, optimization and evaluation, and dedicated proton QA device. Conscious efforts and collaborations from both industry leaders and proton therapy centers are needed to achieve this goal and further advance the technology of proton therapy.

60 APPLIED LIFE SCIENCES↗