Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Plasma flows during the ablation stage of an over-massed pulsed-power-driven exploding planar wire array

We characterize the plasma flows generated during the ablation stage of an over-massed exploding planar wire array, fielded on the COBRA pulsed-power facility (1 MA peak current, 250 ns rise time). The planar wire array is designed to provide a driving magnetic field (80–100 T) and current per wire distribution (about 60 kA), similar to that in a 10 MA cylindrical exploding wire array fielded on the Z machine. Over-massing the arrays enables continuous plasma ablation over the duration of the experiment without implosion. The requirement to over-mass on the Z machine necessitates wires with diameters of 75–100μm, which are thicker than wires usually fielded on wire array experiments. To test ablation with thicker wires, we perform a parametric study by varying the initial wire diameter between 33 and 100 μm. The largest wire diameter (100 μm) array exhibits early closure of the cathode-wire gap, while the gap remains open over the duration of the experiment for wire diameters between 33 and 75 μm. Laser plasma interferometry and time-gated extreme-ultraviolet (XUV) imaging are used to probe the plasma flows ablating from the wires. The plasma flows from the wires converge to generate a pinch, which appears as a fast-moving (V≈100kms−1) column of increased plasma density (n¯e≈2×1018cm−3) and strong XUV emission. Finally, we compare the results with three-dimensional resistive-magnetohydrodynamic (MHD) simulations performed using the code GORGON, the results of which reproduce the dynamics of the experiment reasonably well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A SENSITIVITY AND ARRAY-CONFIGURATION STUDY FOR MEASURING THE POWER SPECTRUM OF 21 cm EMISSION FROM REIONIZATION

Telescopes aiming to measure 21 cm emission from the Epoch of Reionization must toe a careful line, balancing the need for raw sensitivity against the stringent calibration requirements for removing bright foregrounds. It is unclear what the optimal design is for achieving both of these goals. Via a pedagogical derivation of an interferometer's response to the power spectrum of 21 cm reionization fluctuations, we show that even under optimistic scenarios first-generation arrays will yield low-signal-to-noise detections, and that different compact array configurations can substantially alter sensitivity. We explore the sensitivity gains of array configurations that yield high redundancy in the uv-plane-configurations that have been largely ignored since the advent of self-calibration for high-dynamic-range imaging. We first introduce a mathematical framework to generate optimal minimum-redundancy configurations for imaging. We contrast the sensitivity of such configurations with high-redundancy configurations, finding that high-redundancy configurations can improve power-spectrum sensitivity by more than an order of magnitude. We explore how high-redundancy array configurations can be tuned to various angular scales, enabling array sensitivity to be directed away from regions of the uv-plane (such as the origin) where foregrounds are brighter and instrumental systematics are more problematic. We demonstrate that a 132 antenna deployment of the Precision Array for Probing the Epoch of Reionization observing for 120 days in a high-redundancy configuration will, under ideal conditions, have the requisite sensitivity to detect the power spectrum of the 21 cm signal from reionization at a 3{sigma} level at k < 0.25 h Mpc{sup -1} in a bin of {Delta}ln k = 1. We discuss the tradeoffs of low- versus high-redundancy configurations.

79 ASTRONOMY AND ASTROPHYSICS↗

Photoelectrochemical Activity of As-Grown, a-Fe2O3 Nanowire Array Electrodes for Water Splitting

Undoped hematite nanowire arrays grown using plasma oxidation of iron foils show significant photoactivity ({approx}0.38 mA cm{sup -2} at 1.5 V versus reversible hydrogen electrode in 1 M KOH). In contrast, thermally oxidized nanowire arrays grown on iron exhibit no photoactivity due to the formation of a thick (>7 {micro}m Fe{sub 1-x}O) interfacial layer. An atmospheric plasma oxidation process required only a few minutes to synthesize hematite nanowire arrays with a 1-5 {micro}m interfacial layer of magnetite between the nanowire arrays and the iron substrate. An amorphous oxide surface layer on hematite nanowires, if present, is shown to decrease the resulting photoactivity of as-synthesized, plasma grown nanowire arrays. The photocurrent onset potential is improved after removing the amorphous surface on the nanowires using an acid etch. A two-step method involving high temperature nucleation followed by growth at low temperature is shown to produce a highly dense and uniform coverage of nanowire arrays.

14 SOLAR ENERGY↗

Efficient Loads Surrogates for Waked Turbines in an Array

Accurately and efficiently predicting wind turbine structural loading is a crucial step in wind farm design. Without considering structural loading, wind farm optimization could negatively impact turbine fatigue and ultimate loads, especially for waked and partially waked turbines, which could result in higher maintenance costs and reduced turbine lifetime. However, predicting turbine loads throughout an array is a costly step, as these quantities require time-accurate results across long time histories, which is often intractable for large array optimization. Therefore, surrogate models that link array spacing to load outputs are often used, but the surrogates are then unique to the inflow conditions and array configurations in the training library. This work develops surrogate models for many wind turbine load outputs based solely on rotor plane velocity measurements, with no required input about array configuration or freestream inflow parameters. Surrogate models were constructed for many turbine quantities of interest (QoI), considering mean, standard deviation, ultimate, and fatigue loads. In general, most QoI statistics were accurately captured, as measured by predicted vs. actual correlation coefficient, confirming the suitability of the approach. Temporal mean values of the QoI required only temporal mean measurements of the rotor plane inflow velocity. However, accurate prediction of temporal standard deviation, ultimate, and fatigue values of QoI also required temporal standard deviations of the rotor plane velocity field. Poor surrogate performance was observed when too many correlated inputs were used, such as multiple velocity components. If the fewest inflow parameters are used to construct the surrogates, the average correlation coefficient value for all output QoI statistics is 0.89. Surrogates for standard deviations and damage equivalent loads (DELs) of turbine QoIs generally had lower accuracy and tower-base and shaft load channels posed the most difficult to capture accurately. The results suggest that these surrogates could be easily paired with analytic wake models, which are frequently used for pre-construction wind farm array optimization, to account for turbine loading in addition to power production. By including the optimal inflow conditions, the surrogate accuracy can improve to an average correlation coefficient value for all output QoI statistics of 0.92. This work has established the ability to build accurate surrogates for mean, standard deviation, ultimate load, and DEL turbine QoI values based on the rotor plane inflow velocity, and identified which inflow conditions lead to greater surrogate accuracy.

17 WIND ENERGY↗

Characteristics of 1D ordered arrays of optical centers in solid-state photonics

Abstract Collective interaction of emitter arrays has lately attracted significant attention due to its role in controlling directionality of radiation, spontaneous emission and coherence. We focus on light interactions with engineered arrays of solid-state emitters in photonic resonators. We theoretically study light interaction with an array of emitters or optical centers embedded inside a microring resonator and discuss its application in the context of solid-state photonic systems. We discuss how such arrays can be experimentally realized and how the inhomogeneous broadening of mesoscopic atomic arrays can be leveraged to study broadband collective excitations in the array.

Kling, Trevor (ORCID:0000000314967717)↗

FIRMA: a method for detection of alternative splicing from exon array data

Motivation: Analyses of EST data show that alternative splicing is much more widespread than once thought. The advent of exon and tiling microarrays means that researchers now have the capacity to experimentally measure alternative splicing on a genome wide level. New methods are needed to analyze the data from these arrays. Results: We present a method, finding isoforms using robust multichip analysis (FIRMA), for detecting differential alternative splicing in exon array data. FIRMA has been developed for Affymetrix exon arrays, but could in principle be extended to other exon arrays, tiling arrays or splice junction arrays. We have evaluated the method using simulated data, and have also applied it to two datasets: a panel of 11 human tissues and a set of 10 pairs of matched normal and tumor colon tissue. FIRMA is able to detect exons in several genes confirmed by reverse transcriptase PCR.

59 BASIC BIOLOGICAL SCIENCES↗

Internal structure of the San Jacinto fault zone at Jackass Flat from data recorded by a dense linear array

The internal structure of the Clark fault in the trifurcation area of the San Jacinto fault zone is imaged using seismograms recorded by a dense linear array (Jackass Flat, JF) crossing the surface trace of the fault and an adjacent array (TR) to the SW. Delay times between phase arrivals associated with ~3500 local earthquakes and nine teleseismic events are used to estimate velocity variations within the arrays. The teleseismic P waves travel faster beneath the TR than the JF array, in contrast to larger scale tomographic results. Statistical analysis of local P-wave delay times indicates that the entire JF array, with an aperture of ~400 m, is inside a low-velocity damage zone. This low-velocity zone is bounded on the NE side by a shallow bimaterial interface generating fault zone head waves, and it contains an inner zone of more intense damage generating fault zone trapped waves. The P-wave velocity contrast across the local bounding bimaterial interface is 10–15 per cent. The trapping structure is associated with a width of ~200 m, S-wave velocity reduction of ~35 per cent with respect to the surrounding rock, Q-value of ~20 and depth of ~3.5 km. The imaging results suggest that the main seismogenic fault is near the SW end of the JF array, in agreement with a prominent geomorphologic feature. The existence of intense local damage on the crustal block with faster larger scale velocity at depth is consistent with common propagation of earthquake ruptures in the area to the NW.

58 GEOSCIENCES↗

Controlling the transport of single photons by tuning the frequency of either one or two cavities in an array of coupled cavities

We theoretically study how to control transport, bound states, and resonant states of a single photon in a one-dimensional coupled-cavity array. We find that the transport of a single photon in the cavity array can be controlled by tuning the frequency of either one or two cavities. If one of the cavities in the array has a tunable frequency, and its frequency is tuned to be larger (or smaller) than those of other cavities, then there is a photon bound state above (or below) the energy band of the coupled-cavity array. However, if two cavities in the array have tunable frequencies, then there exist both bound states and resonant states. If the frequencies of the two cavities are chosen to be much larger than those of other cavities, and the hopping couplings between any two nearest-neighbor cavities are weak, then a single photon with a resonant wave vector can be trapped in the region between the two frequency-tunable cavities. In this case, a quantum supercavity can be formed by these two frequency-tunable cavities. We also study how to apply this photon transport control to an array of coupled superconducting transmission line resonators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy transfer, orbital angular momentum, and discrete current in a double-ring fiber array

We study energy transfer and orbital angular momentum of supermodes in a double-ring array of evanescently coupled monomode optical fibers. The structure of supermodes and the spectra of their propagation constants are obtained. The geometrical parameters of the array, at which the energy is mostly confined within the layers, are determined. The developed method for finding the supermodes of concentric arrays is generalized for the case of multiring arrays. The orbital angular momentum carried by a supermode of a double-ring array is calculated. The discrete lattice current is introduced. It is shown that the sum of discrete currents over the array is a conserved quantity. The connection of the total discrete current with orbital angular momentum of discrete optical vortices is made.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum spin liquids bootstrapped from Ising criticality in Rydberg arrays

Arrays of Rydberg atoms constitute a highly tunable, strongly interacting venue for the pursuit of exotic states of matter. We develop a strategy for accessing a family of fractionalized phases known as quantum spin liquids in two-dimensional Rydberg arrays. We specifically use effective field theory methods to study arrays assembled from Rydberg chains tuned to an Ising phase transition that famously hosts emergent fermions propagating within each chain. This highly entangled starting point allows us to naturally access spin liquids familiar from Kitaev's honeycomb model—albeit from an entirely different framework. In particular, we argue that finite-range repulsive Rydberg interactions, which frustrate nearby symmetry-breaking orders, can enable coherent propagation of emergent fermions between the chains in which they were born. Delocalization of emergent fermions across the full two-dimensional Rydberg array yields a gapless Z 2 spin liquid with a single massless Dirac cone. Here, the Rydberg occupation numbers exhibit universal power-law correlations that provide a straightforward experimental diagnostic of this phase. We further show that explicitly breaking symmetries perturbs the gapless spin liquid into gapped, topologically ordered descendants: Breaking lattice symmetries generates toric-code topological order, whereas introducing Floquet-mediated chirality generates non-Abelian Ising topological order. In the toric-code phase, we analytically construct microscopic incarnations of non-Abelian defects, which can be created and transported by dynamically controlling the atom positions in the array. Our work suggests that appropriately tuned Rydberg arrays provide a cold-atoms counterpart of solid-state “Kitaev materials” and, more generally, it spotlights a different angle for pursuing experimental platforms for Abelian and non-Abelian fractionalization.

36 MATERIALS SCIENCE↗

Staircase resiliency in a fluctuating cellular array

Inhomogeneous mixing by stationary convective cells set in a fixed array is a particularly simple route to layering. Layered profile structures, or staircases, have been observed in many systems, including drift-wave turbulence in magnetic confinement devices. The simplest type of staircase occurs in passive-scalar advection, due to the existence and interplay of two disparate timescales, the cell turn-over (τ H ), and the cell diffusion (τ D ) time. In this simple system, we study the resiliency of the staircase structure in the presence of global transverse shear and weak vortex scattering. The fixed cellular array is then generalized to a fluctuating vortex array in a series of numerical experiments. The focus is on regimes of low-modest effective Reynolds numbers, as found in magnetic fusion devices. By systematically perturbing the elements of the vortex array, we learn that staircases form and are resilient (although steps become less regular, due to cell mergers) over a broad range of Reynolds numbers. The criteria for resiliency are (a) τ D >>τ H and (b) a sufficiently high profile curvature (κ ≥ 1.5). We learn that scalar concentration travels along regions of shear, thus staircase barriers form first, and scalar concentration "homogenizes" in vortices later. The scattering of vortices induces a lower effective speed of scalar concentration front propagation. The paths are those of the least time. We observe that if background diffusion is kept fixed, the cell geometric properties can be used to derive an approximation for the effective diffusivity of the scalar. Furthermore, the effective diffusivity of the fluctuating vortex array does not deviate significantly from that of the fixed cellular array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implosion dynamics and x-ray generation in small-diameter wire-array Z pinches

It is known from experiments that the radiated x-ray energy appears to exceed the calculated implosion kinetic energy and Spitzer resistive heating [C. Deeney et al., Phys. Rev. A 44, 6762 (1991)] but possible mechanisms of the enhanced x-ray production are still being discussed. Enhanced plasma heating in small-diameter wire arrays with decreased calculated kinetic energy was investigated, and a review of experiments with cylindrical arrays of 1-16 mm in diameter on the 1 MA Zebra generator is presented in this paper. The implosion and x-ray generation in cylindrical wire arrays with different diameters were compared to find a transition from a regime where thermalization of the kinetic energy is the prevailing heating mechanism to regimes with other dominant mechanisms of plasma heating. Loads of 3-8 mm in diameter generate the highest x-ray power at the Zebra generator. The x-ray power falls in 1-2 mm loads which can be linked to the lower efficiency of plasma heating with the lack of kinetic energy. The electron temperature and density of the pinches also depend on the array diameter. In small-diameter arrays, 1-3 mm in diameter, ablating plasma accumulates in the inner volume much faster than in loads of 12-16 mm in diameter. Correlated bubblelike implosions were observed with multiframe shadowgraphy. Investigation of energy balance provides evidence for mechanisms of nonkinetic plasma heating in Z pinches. Formation and evolution of bright spots in Z pinches were studied with a time-gated pinhole camera. A comparison of x-ray images with shadowgrams shows that implosion bubbles can initiate bright spots in the pinch. Features of the implosions in small-diameter wire arrays are discussed to identify mechanisms of energy dissipation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ARCHIE: Data Analysis Acceleration with Array Caching in Hierarchical Storage

© 2018 IEEE. Scientific data analysis typically involves reading massive amounts of data that was generated by simulations, experiments, and observations. Performance of reading such large volumes of data from disk-based file systems is often poor because of the slow and mechanical components in the disks. Recent supercomputing systems are adding non-volatile storage layers in a hierarchy to handle the performance gap between fast main memory and slow disk-based storage. Software libraries for managing this hierarchy not only need efficient reading of data but also reduce user-involvement for cross-layer data movement. Furthermore, these libraries need to support array data access patterns into hierarchical storage management as scientific data is often organized in array-based data structures. Existing software typically manage individual storage layers requiring significant manual process in moving data among them. In this paper, we introduce a new array caching in hierarchical storage (ARCHIE) to accelerate array data analysis in a seamless fashion. ARCHIE evaluates array access patterns and prefetches data with array semantics between storage layers. Our evaluation shows that ARCHIE outperforms state-of-the-art file systems, i.e., Lustre and DataWarp, on a production supercomputing system by up to 5.8× in accessing data by scientific analysis applications.

Dong, Bin↗

Mini Compton Camera Based on an Array of Virtual Frisch-Grid CdZnTe Detectors

In this study, we constructed a mini Compton camera based on an array of CdZnTe detectors and assessed its spectral and imaging properties. The entire array consisted of 6×6 Frisch-grid CdZnTe detectors, each with a size of 6×6 ×15 mm 3 . Since it is easier and more practical to grow small CdZnTe crystals rather than large monolithic ones, constructing a mosaic array of parallelepiped crystals can be an effective way to build a more efficient, large-volume detector. With the fully operational CdZnTe array, we measured the energy spectra for 133 Ba -, 137 Cs -, 60 Co-radiation sources; we also located these sources using a Compton imaging approach. Although the Compton camera was small enough to hand-carry, its intrinsic efficiency was several orders higher than those generated in previous researches using spatially separated arrays, because our camera measured the interactions inside the CZT detector array, wherein the detector elements were positioned very close to each other. Lastly, the performance of our camera was compared with that based on a pixelated detector.

36 MATERIALS SCIENCE↗

Development of Pseudorandom Binary Arrays for Calibration of Surface Profile Metrology Tools

Optical metrology tools, especially for short wavelengths (extreme ultraviolet and x-ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown point-spread function (PSF) of the instruments [G. D. Boreman, Modulation Transfer Function in Optical and Electro-Optical Systems (SPIE, Bellingham, WA, 2001)] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account for because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in the spatial frequency domain as a power spectral density (PSD) distribution [J. W. Goodman, Introduction to Fourier Optics, 3rd ed. (Roberts and Company, Englewood, CO, 2005)]. For example, measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [E. L. Church et al., Opt. Eng. (Bellingham) 18, 125 (1979); J. C. Stover, Optical Scattering, 2nd ed. (SPIE Optical Engineering Press, Bellingham, WA, 1995)]. The distortion of the surface PSD distribution due to the PSF can be modeled with the modulation transfer function (MTF), which is defined over the spatial frequency bandwidth of the instrument. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the system under test. Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. The applicability of the MTF concept to phase map measurements with optical interferometric microscopes needs to be experimentally verified as the optical tool and algorithms may introduce nonlinear artifacts into the process. In previous work [V. V. Yashchuk et al., Proc. SPIE 6704, 670408 (2007); Valeriy V. Yashchuk et al., Opt. Eng. (Bellingham) 47, 073602 (2008)] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudorandom (BPR) gratings. Here, the authors present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as global position systems and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the uniformly redundant array (URA) prescription [E. E. Fenimore and T. M. Cannon, Appl. Opt. 17, 337 (1978)] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and induction coupled plasma etching of silicon. The basic size units were 200, 400, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The MicroMap{trademark}-570 interferometric microscope uses incoherent illumination from a tungsten filament source and common path modulated phase shifting interference to produce a set of interferograms detected on a change coupled device. Mathematical algorithms applied to the datasets yield the surface phase map. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples [Samuel K. Barber et al., Abstract to Optics and Photonics 2009: Optical Engineering and Applications Symposium, San Diego, CA, 2-6 August 2009]. Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom

For routine pretreatment verification of innovative treatment techniques such as (intensity modulated) dynamic arc therapy and helical TomoTherapy, an on-line and reliable method would be highly desirable. The present solution proposed by TomoTherapy, Inc. (Madison, WI) relies on film dosimetry in combination with up to two simultaneous ion chamber point dose measurements. A new method is proposed using a 2D ion chamber array (Seven29, PTW, Freiburg, Germany) inserted in a dedicated octagonal phantom, called Octavius. The octagonal shape allows easy positioning for measurements in multiple planes. The directional dependence of the response of the detector was primarily investigated on a dual energy (6 and 18 MV) Clinac 21EX (Varian Medical Systems, Palo Alto, CA) as no fixed angle incidences can be calculated in the Hi-Art TPS of TomoTherapy. The array was irradiated from different gantry angles and with different arc deliveries, and the dose distributions at the level of the detector were calculated with the AAA (Analytical Anisotropic Algorithm) photon dose calculation algorithm implemented in Eclipse (Varian). For validation on the 6 MV TomoTherapy unit, rotational treatments were generated, and dose distributions were calculated with the Hi-Art TPS. Multiple cylindrical ion chamber measurements were used to cross-check the dose calculation and dose delivery in Octavius in the absence of the 2D array. To compensate for the directional dependence of the 2D array, additional prototypes of Octavius were manufactured with built-in cylindrically symmetric compensation cavities. When using the Octavius phantom with a 2 cm compensation cavity, measurements with an accuracy comparable to that of single ion chambers can be achieved. The complete Octavius solution for quality assurance of rotational treatments consists of: The 2D array, two octagonal phantoms (with and without compensation layer), an insert for nine cylindrical ion chambers, and a set of inserts of various tissue equivalent materials of different densities. The combination of the 2D array with the Octavius phantom proved to be a fast and reliable method for pretreatment verification of rotational treatments. Quality control of TomoTherapy patients was reduced to a total of {approx}25 min per patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-BRE-04: Evaluating the Dose Accuracy of a 2D Ion Chamber Array in High Dose Rate Pencil Beam Scanning Proton Beam

Purpose: To evaluate the absolute dose accuracy of the PTW Octavius 729 XDR 2D ion chamber array at a high dose rate pencil beam scanning proton therapy facility. Methods: A set of 18 plans were created in our treatment planning system, each of which comprising a unique combination of field sizes (FS), length of spread out of Bragg peaks (SOBP) and depths. The parameters used were: FS of 5×5cm{sup 2}, 10×10cm{sup 2} and 15×15cm{sup 2}; flat SOBP of 5cm and 10cm; and isocenter depths of 10cm, 15cm and 20cm, which coincides with the center of the SOBP. The 2D array detector was positioned at the machine isocenter and the appropriate amount of solid water was used to match the planned depths of 10, 15 and 20 cm water equivalent depth. Subsequently, we measured the absolute dose at isocenter using a CC04 ion chamber in a 1D water tank. Both 2D array and CC04 were previously cross calibrated. We also collected the MU rates used by our proton machine from the log files. Results: The relative differences between the CC04 and the 2D array can be summarized into two groups, one with 5 cm SOBP and another with 10 cm SOBP. Plotting these datasets against FS shows that the 2D array response for high dose rate fields (FS of 5×5cm{sup 2} and 5cm SOBP) can be up to 2% lower. Similarly, plotting them against isocenter depths reveals the detector's response can be up to 2% lower for higher energy beams (about 200MeV nominal). The MU rate found in the machine log files for 5cm SOBP's were as high as twice the MU rate for the 10cm SOBP. Conclusion: The 2D array dose response showed a dose rate effect in scanning pencil beam delivery, which needs to be corrected to achieve a better dose accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-111: Development of Proton Dosimetry System Using Fiber-Optic Cerenkov Radiation Sensor Array

Purpose: We had developed and evaluated a new dosimetric system for proton therapy using array of fiber-optic Cerenkov radiation sensor (FOCRS) which can measure a percent depth dose (PDD) instantly. In this study, the Bragg peaks and spread out Bragg peak (SOBP) of the proton beams measured by FOCRS array were compared with those measured by an ion chamber. Methods and Method: We fabricated an optical fiber array of FOCRS in a handmade phantom which is composed of poly-methyl methacrylate (PMMA). There are 75 holes of 1mm diameter inside the phantom which is designed to be exposed in direction of beam when it is emerged in water phantom. The proton beam irradiation was carried out using IBA cyclotron PROTEUS 235 at national cancer center in Korea and a commercial data acquisition system was used to digitize the analog signal. Results: The measured Bragg peak and SOBP for the proton ranges of 7∼ 20 cm were well matched with the result from ion chamber. The comparison results show that the depth of proton beam ranges and the width of SOBP measured by array of FOCRS are comparable with the measurement from multi-layer ion chamber (MLIC) although there are some uncertainty in the measurement of FOCRS array for some specific beam ranges. Conclusion: The newly developed FOCRS array based dosimetric system for proton therapy can efficiently reduce the time and effort needed for proton beam range measurement compared to the conventional method and has the potential to be used for the proton pencil beam application.

07 ISOTOPE AND RADIATION SOURCES↗