Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ASSISTED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Surfactant-assisted stabilization of Au colloids on solids for heterogeneous catalysis

Here, the stabilization of surfactant-assisted synthesized colloidal noble metal nanoparticles (NPs, e.g., Au NPs) on solids is a promising strategy for preparing supported nanocatalysts for heterogeneous catalysis because of their uniform particle sizes, controllable shapes, and tunable compositions. However, the removal of surfactants to obtain clean surfaces for catalysis through traditional approaches (e.g., solvent extraction and thermal decomposition) can easily induce the sintering of NPs, greatly hampering their use in synthesis of novel catalysts. Herein, we demonstrate that such unwanted surfactants can be utilized to stabilize NPs on solids via a simple yet efficient thermal annealing strategy. After being annealed in N 2 flow, the surface-bound surfactants are in situ carbonized as sacrificial architectures that form a conformal coating on NPs and assist in creating an enhanced metal-support interaction between NPs and substrate, thus slowing down the Ostwald ripening process during post-oxidative calcination to remove surface covers.

36 MATERIALS SCIENCE↗

Mechanically Assisted Self‐Healing of Ultrathin Gold Nanowires

Abstract As the critical feature sizes of integrated circuits approaching sub‐10 nm, ultrathin gold nanowires (diameter <10 nm) have emerged as one of the most promising candidates for next‐generation interconnects in nanoelectronics. Also due to their ultrasmall dimensions, however, the structures and morphologies of ultrathin gold nanowires are more prone to be damaged during practical services, for example, Rayleigh instability can significantly alter their morphologies upon Joule heating, hindering their applications as interconnects. Here, it is shown that upon mechanical perturbations, predamaged, nonuniform ultrathin gold nanowires can quickly recover into uniform diameters and restore their smooth surfaces, via a simple mechanically assisted self‐healing process. By examining the local self‐healing process through in situ high‐resolution transmission electron microscopy, the underlying mechanism is believed to be associated with surface atomic diffusion as evidenced by molecular dynamics simulations. In addition, mechanical manipulation can assist the atoms to overcome the diffusion barriers, as suggested by ab initio calculations, to activate more surface adatoms to diffuse and consequently speed up the self‐healing process. This result can provide a facile method to repair ultrathin metallic nanowires directly in functional devices, and quickly restore their microstructures and morphologies by simple global mechanical perturbations.

Wang, Binjun↗

Microwave‐Assisted Synthesis of SrTiO 3 Nanocuboids without TiCl 4

Strontium titanate (STO) nanocuboids are a novel support for Pt nanoparticle catalysts (Pt/STO). The first of many steps in commercializing Pt/STO will be developing a scalable, environmentally sustainable, and cost‐effective STO nanocuboid synthesis. Herein, Sr–Ti–OH mixtures are synthesized from various Sr 2+ and Ti 4+ reagents and treated by convection‐ and microwave‐assisted heating to obtain STO nanoparticles. These experiments clarify how phase composition of the prehydrothermal Sr–Ti–OH mixture and choice of heating method affect final nanoparticle morphology. In Sr–Ti–OH mixtures synthesized with TiCl 4 , STO is the most stable phase and precipitates prior to heating, while titania sol–gels are the most stable phase when other Ti 4+ sources are used. STO nanocrystals always form when Sr–Ti–OH mixtures are treated by convection heating, though nanocuboids are only observed if STO precipitates from the Sr–Ti–OH mixture. Microwave‐assisted hydrothermal treatment more rapidly heats the precursor solution, and thus, STO nanocuboids can form from a variety of Sr–Ti–OH mixtures regardless of mixture composition. Two microwave syntheses of STO nanocuboids are reported: one which uses TiCl 4 as a Ti 4+ source, and another that uses titanium(IV) bis(ammonium lactato) dihydroxide ([NH 4 CH 3 CH(O)CO 2 ] 2 Ti(OH) 2 ), a water‐stable Ti 4+ complex.

Peczak, Ian L.↗

Tungsten Diselenide Patterning and Nanoribbon Formation by Gas‐Assisted Focused‐Helium‐Ion‐Beam‐Induced Etching

A gas‐assisted focused‐helium‐ion beam‐induced etching (FIBIE) process is introduced, which accelerates direct‐write patterning of WSe 2 relative to standard ion milling. The etching process utilizes the XeF 2 precursor molecule to provide a chemical assist for enhanced material removal relative to ion sputtering. The FIBIE process enables high‐fidelity patterning of WSe 2 with doses 5× lower than standard He + milling. This enables the formation of high‐resolution WSe 2 nanoribbons with dimensions less than 10 nm. The WSe 2 nanoribbons demonstrate high Raman anisotropy and nanoribbon electrical measurements are reported for the first time. The normalized on‐currents of field‐effect transistors reveal that the electron and hole currents are both suppressed and scale with the nanoribbon width, with the electron transport experiencing more degradation. However, on‐currents of nanoribbons created by the FIBIE process remain orders of magnitude greater than nanoribbons formed by standard He + milling. Scanning transmission electron microscopy and complementary Monte Carlo ion–solid simulations reveal that the reduced currents are partially due to ion‐induced damage in the WSe 2 .

Stanford, Michael G.↗

Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting

To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergent Embolization of Arterial Bleeding after Vacuum-Assisted Breast Biopsy

Vacuum-assisted core breast biopsy has become important in evaluating patients with suspicious breast lesions. It has proven to be a relatively safe procedure that in rare cases can result in vascular complications. These are the first reported cases of transcatheter embolization of uncontrolled breast hemorrhage after vacuum-assisted breast biopsy. With increased use of biopsy and larger-gauge devices, breast imaging groups may consider embolotherapy as a safe alternative for treatment of hemorrhage in a select group of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Path Planning Software-Assisted Transjugular Intrahepatic Portosystemic Shunt: A Technical Modification

PurposeThis study was designed to report our results with a modified technique of three-dimensional (3D) path planning software assisted transjugular intrahepatic portosystemic shunt (TIPS).Methods3D path planning software was recently developed to facilitate TIPS creation by using two carbon dioxide portograms acquired at least 20° apart to generate a 3D path for overlay needle guidance. However, one shortcoming is that puncturing along the overlay would be technically impossible if the angle of the liver access set and the angle of the 3D path are not the same. To solve this problem, a prototype 3D path planning software was fitted with a utility to calculate the angle of the 3D path. Using this, we modified the angle of the liver access set accordingly during the procedure in ten patients.ResultsFailure for technical reasons occurred in three patients (unsuccessful wedged hepatic venography in two cases, software technical failure in one case). The procedure was successful in the remaining seven patients, and only one needle pass was required to obtain portal vein access in each case. The course of puncture was comparable to the 3D path in all patients. No procedure-related complication occurred following the procedures.ConclusionsAdjusting the angle of the liver access set to match the angle of the 3D path determined by the software appears to be a favorable modification to the technique of 3D path planning software assisted TIPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact and Effectiveness of Dual Aspiration Technique in Stent-Assisted Mechanical Thrombectomy: Recent Improvements in Acute Stroke Management

Background and PurposeTo evaluate feasibility and impact of dual aspiration technique (DAT) within stent-assisted mechanical thrombectomy on procedural parameters and clinical outcome.Materials and MethodsWithin 16 months, 76 consecutive patients (mean age 70.7 year; range 33–89) underwent stent-assisted mechanical thrombectomy. Of 52 enrolled patients (68.4 %) with occlusion of the anterior circulation, 22 patients (42.3 %) underwent DAT; 30 patients (57.7 %) were treated in conventional monoaspiration technique (MAT). Epidemiological data, clinical and imaging characteristics (mRS, NIHSS, ASPECTS) as well as procedural details were analyzed (TICI, number of retrieval, procedure time). Clinical outcome was determined with mRS at discharge and after 90 days.ResultsIn the context of DAT additional carotid artery stenting was required in 45.5 % (10/22) in underlying tandem lesion (vs. 0/30 MAT). No differences were found in NIHSS at admission (MAT: 20.5, range 15–29; DAT: 18.6; range 11–25), mRS at admission (MAT: 4.6 vs. DAT: 4.57) or ASPECT score (MAT: 8.3, ±1.5; DAT: 8.4, ±1.5; P > 0.05). TICI ≥ 2b/3 was conducted in 90 % (MAT) and 100 % (DAT), respectively. The procedure time was longer in the MAT group (65 min, ±25.9, range 18–126) compared to the DAT group (49.7 min, ±15, range 32–101; P = 0.016). The clinical outcome increased from admission to discharge and in follow-up after 90 days (mRS ≥ 2: MAT: 53.3 %, DAT: 54.5 %; P > 0.05).ConclusionsThe dual aspiration technique with an additional intermediate guide catheter placed closed to the stent retriever leads to decreased procedure time in the anterior circulation. Even in cases with higher thrombus load and treated in DAT, clinical outcome improved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Microwave-Assisted Annealing on the Structure and Magnetic Properties of (Nd{sub 0.75}Pr{sub 0.25}){sub 9}Fe{sub 72}Ti{sub 1}Zr{sub 3}Mn{sub x} Mo{sub 4−x}B{sub 10.5}C{sub 0.5} Amorphous Ribbons

The amorphous as-spun ribbons with nominal composition (Nd{sub 0.75}Pr{sub 0.25}){sub 9}Fe{sub 72}Ti{sub 1}Zr{sub 3}Mn{sub x}Mo{sub 4−x}B{sub 10.5}C{sub 0.5}(x = 1, 2, 3) were annealed by microwave-assisted annealing. The effects of the Mn-doped alloys on glass-forming ability (GFA), crystallization, and magnetic properties of the Nd{sub 2}Fe{sub 14}B/α-Fe nanocomposite magnets were examined by thermal differential scanning calorimetry (DSC), X-ray diffraction (XRD), and vibrating sample magnetometry (VSM). An appropriate amount of Mn was beneficial to the optimization of the structure and magnetic properties. Compared with conventional annealing, the microwave-assisted annealing has contributed to the precipitation of hard magnetic phases and adjusted the proportion of hard and soft magnetic phases. The optimum magnetic properties with coercivity up to 805 kA/m were found for ribbons (with composition x = 1) annealed under the microwave power of 2000 W for 10 min.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assisted assignment of ligands corresponding to unknown electron density.

A semi-automated computational procedure to assist in the identification of bound ligands from unknown electron density has been developed. The atomic surface surrounding the density blob is compared to a library of three-dimensional ligand binding surfaces extracted from the Protein Data Bank (PDB). Ligands corresponding to surfaces which share physicochemical texture and geometric shape similarities are considered for assignment. The method is benchmarked against a set of well represented ligands from the PDB, in which we show that we can identify the correct ligand based on the corresponding binding surface. Finally, we apply the method during model building and refinement stages from structural genomics targets in which unknown density blobs were discovered. A semi-automated computational method is described which aims to assist crystallographers with assigning the identity of a ligand corresponding to unknown electron density. Using shape and physicochemical similarity assessments between the protein surface surrounding the density and a database of known ligand binding surfaces, a plausible list of candidate ligands are identified for consideration. The method is validated against highly observed ligands from the Protein Data Bank and results are shown from its use in a high-throughput structural genomics pipeline.

59 BASIC BIOLOGICAL SCIENCES↗

Hybrid CdS nanowires/Si heterostructure photodetector fabricated by intense pulsed light assisted - laser ablation in liquid

Synthesis of CdS nanowires NWs by combined intense pulsed light (IPL) and pulsed laser ablation in liquid is demonstrated for the first time. An IPL source providing 3 ms duration pulses was used to assist the synthesis of CdS nanowires by 7 ns pulsed laser ablation of cadmium target in thiourea and CTAB solution. The results showed a small increase in optical energy band gap of CdS NWs and a decrease of the nanowires diameter from 50 to 40 nm after combining the IPL. The intensity of the photoluminescence emission peak located at 458 nm was doubled when the IPL combined laser ablation process. In addition the synthesized CdS nanowires showed single crystalline pure hexagonal wurtzite phase with decreased particles agglomeration and smaller particle size. Raman spectra were improved too by revealing sharp and shifted peaks at 293 and 585 cm{sup −1}. The figures of merit of hybrid n-CdSNWs/p-Si heterojunction photodetector namely responsivity and minority carrier lifetime were found to be improved remarkably after using IPL assisted laser ablation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Current-Assisted Diffusion Bonding of Extruded Ti-22Al-25Nb Alloy by Spark Plasma Sintering: Interfacial Microstructure and Mechanical Properties

Spark plasma sintering (SPS) technology was used to current-assisted bond extruded Ti-22Al-25Nb alloy. The effects of bonding temperature (920-980 °C) and bonding time (10-30 min) on the microstructure evolution and shear strength of this alloy were investigated systematically. The temperature distribution in the specimen during the current-assisted bonding process was also analyzed by numerical simulation. It is noted that the highest temperature was obtained at the bonding interface. As the bonding temperature and bonding time increased, the voids in the interface shrank increasingly until they vanished. A complete metallurgical bonding interface could be produced at 960 °C/20 min/10 MPa, exhibiting the highest shear strength of 269.3 MPa. In addition, the shear strength of the bonded specimen depended on its interfacial microstructure. With increased bonding temperature, the fracture mode transformed from the intergranular fracture at the bonding interface to the cleavage fracture in the substrate.

36 MATERIALS SCIENCE↗

Effect of a Zinc Interlayer on a Cu/Al Lap Joint in Ultrasound-Assisted Friction Stir Welding

This study proposes a welding process, ultrasound-assisted friction stir welding of dissimilar Al/Cu metals. Zinc foil is melted using the heat generated by a pinless stirring tool, and the molten intermediate layer is stirred by ultrasonic cavitation to achieve an effective connection. The metallurgical reaction behavior of the joint under the action of the sound field was studied, and the effects of different microstructures on the joint performance were analyzed. Specifically, the following observations were reported in this study: (1) When ultrasound assistance was used, the cavitation effect changed the brittle intermetallic compounds of Al{sub 2}Cu from a continuous distribution to a block distribution, and the mechanical properties of the joint were greatly improved; (2) the effects of the thickness of the zinc were also determined. The results showed that the highest shear tensile force was obtained when the thickness of the zinc foil was 0.2 mm. When the thickness was 0.3 mm, the ultrasound effect was weakened. The copper-side interface generated a zigzag-shaped Al{sub 4.2}Cu{sub 3.2}Zn{sub 0.7} layer with a thickness of 3.4 μm and had a continuous distribution. Increasing the thickness of the zinc to 0.5 mm, however, drastically decreased the mechanical properties of the joint due to incomplete melting of the zinc layer.

36 MATERIALS SCIENCE↗

Infections in patients using ventricular-assist devices: Comparison of the diagnostic performance of {sup 18}F-FDG PET/CT scan and leucocyte-labeled scintigraphy

Background: The usage of left-ventricular-assist device (LVAD) is increasing in patients presenting with advanced heart failure. However, device-related infections are a challenge to recognize and to treat, with an important morbidity and mortality rate. The role of nuclear medicine imaging remains not well established for LVAD infections. The present study compared the accuracy of positron emission tomography/computed tomography with {sup 18}F-fludeoxyglucose ({sup 18}F-FDG PET/CT) and radiolabeled leucocyte scintigraphy for the diagnosis of infections in patients supported with a continuous-flow LVAD. Methods: From a prospectively maintained database, we retrospectively analyzed the diagnostic performance of radiolabeled leucocyte scintigraphy and {sup 18}F-FDG PET/CT in 24 patients who had a LVAD with a suspected device-related infection. Both examinations were routinely performed in all patients. Infection was assessed by the International Society for Heart and Lung Transplantation criteria. Results: Twenty-four patients were included: 15 had a specific VAD infection (5 cardiac-LVAD and 10 driveline), 6 had a VAD-related infection, while 3 patients had a non-VAD-related infection. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 95.2%, 66.7%, 95.2%, 66.7%, and 91.6%, respectively, for {sup 18}F-FDG-PET; and 71.4%, 100%, 100%, 33.3%, and 75%, respectively, for leucocyte scintigraphy. {sup 18}F-FDG PET/CT showed significantly higher sensitivity (P = 0.01) than leucocyte scintigraphy. Conclusion: {sup 18}F-FDG PET/CT and radiolabeled leucocyte scintigraphy single-photon emission computed tomography carry high performance in the diagnostic of LVAD infections. {sup 18}F-FDG PET/CT shows significantly higher sensitivity and could be proposed as first-line nuclear medicine procedure. [French] French Abstract: Contexte: L’utilisation du dispositif d’assistance ventriculaire gauche (DAVG) est en utilisation croissante chez les patients avec insuffisance cardiaque avancée. Cependant, les infections liées au dispositif sont un défi à reconnaître et à traiter en raison d’ un taux de morbidité et de mortalité important. Le rôle de l’imagerie de médecine nucléaire n’est pas encore bien établi pour les infections secondaires au DAVG. La présente étude compare la précision de la tomographie par émission de positrons / tomodensitométrie au 18F-fluorodéoxyglucose (18F-FDG TEP/TDM) et la scintigraphie leucocytaire radio-marquée pour le diagnostic d’infections chez des patients porteurs par un DAVG à flux continu. Méthodes: A partir d’une base de données complétée de manière prospective nous avons analysé rétrospectivement les performances diagnostiques de la scintigraphie leucocytaire radio-marquée et de la TEP / TDM au 18F-FDG chez 24 patients ayant un DAVG avec une infection suspectée liée à l’appareillage. Les deux types d’examens scintigraphiques ont été systématiquement réalisé chez tous les patients. Le diagnostic d’infection fut établi selon les critères ISHLT. Résultats: Parmi les 24 patients inclus, 15 avaient une infection spécifique de l’appareillage AVG (5 au niveau de la pompe et/ou canule d’insertion myocardique) et 10 au niveau du driveline, 6 avaient une infection indirectement liée à l’appareillage AVG, tandis que 3 patients avaient une infection non liée au DAVG. La sensibilité, la spécificité, la valeur prédictive positive, la valeur prédictive négative et la précision étaient de 95,2%, 66,7%, 95,2%, 66,7% et 91,6%, respectivement, pour le 18F-FDG-PET et 71,4%, 100%, 100%, 33,3 %, et 75%, respectivement, pour la scintigraphie leucocytaire. La TEP / TDM au 18F-FDG a montré une sensitivité significativement plus élevée (p = 0,01) que la scintigraphie leucocytaire. Conclusion: 18F-FDG TEP/TDM et scintigraphie leucocytaire radio-marquée SPECT s’avèrent très efficaces pour le diagnostic des infections à DVAG. La TEP/TDM au 18F-FDG montre une sensibilité significativement plus élevée et pourrait être proposée en tant que la procédure de médecine nucléaire de premier choix. [Spanish] Spanish Abstract: Antecedentes: El uso de dispositivos de asistencia ventricular izquierda (DAVI) está incrementando en pacientes con insuficiencia cardiaca avanzada. Sin embargo, las infecciones relacionadas al dispositivo representan un reto diagnóstico y de tratamiento, con una importante tasa de morbilidad y mortalidad. El papel de los estudios de imagen de medicina nuclear en las infecciones de DAVI no se ha establecido claramente. El presente estudio comparó la precisión de la tomografía por emisión de positrones/tomografía computada con {sup 18}F-fluorodesoxiglucosa ({sup 18}F-FDG PET/CT) y la gammagrafía con leucocitos marcados para el diagnóstico de infecciones en pacientes utilizando un DAVI de flujo continuo. Métodos: Desde una base de datos obtenida de manera prospectiva, analizamos de manera retrospectiva el rendimiento diagnóstico de la gammagrafía de leucocitos marcados y del {sup 18}F-FDG PET/CT en 24 pacientes quienes tenían un DAVI con sospecha de infección relacionada al dispositivo. Ambos estudios fueron realizados rutinariamente en todos los pacientes. Se determinó la presencia de infección mediante los criterios de la ISHTL. Resultados: Se incluyeron veinticuatro pacientes, de los cuales 15 tuvieron una infección específica de DAV (5 con infecciones DAVI, y 10 con infección del driveline), 6 tuvieron una infección relacionada al DAV, y 3 pacientes tuvieron una infección no relacionada al DAV. La sensibilidad, especificidad, valor predictivo positivo, valor predictivo negativo y precisión diagnóstica fueron 95.2%, 66.7%, 95.2%, 66.7% y 91.6%, respectivamente para {sup 18}F-FDG PET/CT, y 71.4%, 100%, 100%, 33.3% y 75%, respectivamente para la gammagrafía de leucocitos marcados. El {sup 18}F-FDG PET/CT mostró una significativa mayor sensibilidad (p=0.01) que la gammagrafía con leucocitos marcados. Conclusión: El {sup 18}F-FDG PET/CT y la gammagrafía de leucocitos marcados tienen un alto desempeño en el diagnóstico de infecciones de DAVI. El {sup 18}F-FDG PET/CT muestra una significativa mayor sensibilidad y podría ser propuesto como el procedimiento de medicina nuclear de primera línea. [Chinese] Chinese Abstract: 背景: 左心室辅助装置 (LVAD) 越来越多的应用于重度心力衰竭患者。然而, 设备相关的感染有着重要的发病率和死亡率, 并且对其诊断和治疗均是一项挑战。对于 LVAD 相关感染, 核医学影像可扮演的角色一直没有完善。本研究针对装备有连续流式 LVAD 的感染病人,对比了 {sup 18}F-FDG PET/CT 造影术和放射性标记白细胞闪烁扫描法对感染诊断的准确性。 方法: 从一个前瞻性的数据库, 入选了24名疑似设备感染的 LVAD 病人, 并回顾性的分析了放射性标记白细胞闪烁扫描法和 {sup 18}F-FDG PET/CT 的诊断表现。所有病人都常规进行了上述两种检查。利用 ISHLT 标准对感染情况进行评估。 结果: 在入选的 24 名病人中, 15 名有明确的 VAD 感染 (5 名心脏的 LVAD 和 10 名动力传动系统装置), 6 名有 VAD 相关的感染,另外3名有 VAD 无关的感染。对于 {sup 18}F-FDG PET/CT 诊断方法,其敏感性,特异性,阳性预测值,阴性预测值和准确率分别为: 95.2%, 66.7%, 95.2%, 66.7%, 和 91.6%; 而对于白细胞闪烁扫描诊断方法, 其敏感性, 特异性, 阳性预测值,阴性预测值和准确率分别为: 71.4%, 100%, 100%, 33.3% 和 75%。相比于白细胞闪烁扫描, {sup 18}F-FDG PET/CT 明显展现出较高的敏感性 (p=0.01)。 结论: {sup 18}F-FDG PET/CT 和白细胞闪烁扫描 SPECT 对于 LVAD 感染的诊断具有很好的表现。{sup 18}F-FDG PET/CT 展现出较高的敏感性,可以作为核医学的首要检查。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Molecular Characterization of High Molecular Weight Polyesters by Matrix-Assisted Laser Desorption/Ionization High-Resolution Time-of-Flight Mass Spectrometry Combined with On-plate Alkaline Degradation and Mass Defect Analysis

Matrix-assisted laser desorption ionization high-resolution time-of-flight mass spectrometry (MALDI HR TOF MS) is a powerful tool for the molecular characterization of industrial polymers. However, accurate mass determination and resolution of isobaric ions are possible for oligomer samples only typically below m/z 3000. To cut long polymer chains into oligomers suitable for high-resolution mass spectrometry, we propose a simple “on-plate” alkaline degradation of polyesters as a sample pretreatment technique prior to the MALDI TOF MS measurement. This pretreatment can be performed on a MALDI target using a small amount of sample (μg or less) and 1 μL of alkaline reagent by simple pipetting. Informative mass spectra in the oligomeric mass range are successfully recorded but complicated by the variation of end-groups and the copolymeric composition of the degradation products. Data processing is assisted by a series of advanced Kendrick mass defect (KMD) analyses recently proposed by the authors to plot visually understandable two-dimensional maps. On-plate degradation pretreatment, high-resolution MALDI TOF MS measurements, and advanced KMD analyses are innovatively combined for the compositional characterization of bacterial poly(3-hydroxybutyric acid-co-3-hydroxyvaleric acid) and industrial poly(ethylene terephthalate) samples. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantum-assisted associative adversarial network: applying quantum annealing in deep learning

Abstract Generative models have the capacity to model and generate new examples from a dataset and have an increasingly diverse set of applications driven by commercial and academic interest. In this work, we present an algorithm for learning a latent variable generative model via generative adversarial learning where the canonical uniform noise input is replaced by samples from a graphical model. This graphical model is learned by a Boltzmann machine which learns low-dimensional feature representation of data extracted by the discriminator. A quantum processor can be used to sample from the model to train the Boltzmann machine. This novel hybrid quantum-classical algorithm joins a growing family of algorithms that use a quantum processor sampling subroutine in deep learning, and provides a scalable framework to test the advantages of quantum-assisted learning. For the latent space model, fully connected, symmetric bipartite and Chimera graph topologies are compared on a reduced stochastically binarized MNIST dataset, for both classical and quantum sampling methods. The quantum-assisted associative adversarial network successfully learns a generative model of the MNIST dataset for all topologies. Evaluated using the Fréchet inception distance and inception score, the quantum and classical versions of the algorithm are found to have equivalent performance for learning an implicit generative model of the MNIST dataset. Classical sampling is used to demonstrate the algorithm on the LSUN bedrooms dataset, indicating scalability to larger and color datasets. Though the quantum processor used here is a quantum annealer, the algorithm is general enough such that any quantum processor, such as gate model quantum computers, may be substituted as a sampler.

Wilson, Max (ORCID:0000000207983391)↗

Formation of misfit dislocation arrays and helium nanochannels near copper surface assisted by high-temperature graphene deposition

Misfit dislocation arrays (MDAs) at semi-coherent heterogeneous interface have been demonstrated effectiveness to trap and then outgas helium (He) for alleviating void swelling in metals, but limited by atomic-level thin film deposition that is difficult to scale-up for industrial production. In this work, we proposed an innovative strategy that could generate semi-coherent homophase interfaces in a same grain by varying surface energy density assisted by high-temperature graphene (Gr) deposition. This strategy transforms strain energy and surface energy, two originally distinctive processes into successive processes, and demonstrates experimentally and theoretically by introducing {111} copper (Cu) in a {100} Cu grain. Subsequent He implantation and electrical resistivity measurement results suggest that high-density MDAs originated at this {111}/{100} interface could form stable He nanochannels near Cu surface with Gr assistance, manifesting by ultra-low increased ratio of the electrical resistivity (i.e. ~3800% of Cu vs. ~90% of Gr/Cu) after He implantation. Finally, the present findings may provide a new strategy for efficiently managing He and achieving surface protection of advanced metals, merely by depositing a super-rigid material on metal surface to greatly reduce surface energy density.

36 MATERIALS SCIENCE↗

Environment assisted energy transfer in dimer system

The influence of collective and multilocal environments on the energy transfer between the levels of a dimer is studied. The dynamics of energy transfer are investigated by considering coupling of collective environment with the levels of the dimer in the presence of both two individuals and mutually correlated multilocal environments. It is shown that every way of coupling we consider assists, though differently, the probability of transition between the levels of dimer. The probability of transition is strongly enhanced when the two local environments are mutually correlated. -- Highlights: • The dynamics of energy transfer between the levels of a dimer are studied. • Coupling of collective as well as individual environments are considered. • The environments are in spin star configurations. • The environment assists the energy transfer between the levels. • For correlated multilocal environments, the transition probability is almost 100%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗