Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “6.1”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Discovery of Gamma Rays from the Quiescent Sun with HAWC

We report the first detection of a TeV γ-ray flux from the solar disk (6.3⁢σ), based on 6.1 years of data from the High Altitude Water Cherenkov (HAWC) observatory. The 0.5–2.6 TeV spectrum is well fit by a power law, dN/dE = A⁢(E/1 TeV) -γ , with A = (1.6 ± 0.3)×10 -12 TeV -1 cm -2 s -1 and γ = 3.62 ± 0.14. The flux shows a strong indication of anticorrelation with solar activity. These results extend the bright, hard GeV emission from the disk observed with Fermi-LAT, seemingly due to hadronic Galactic cosmic rays showering on nuclei in the solar atmosphere. However, current theoretical models are unable to explain the details of how solar magnetic fields shape these interactions. HAWC’s TeV detection thus deepens the mysteries of the solar-disk emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Random singlet-like state in the dimer-based triangular antiferromagnet Ba 6 Y 2 Rh 2 Ti 2 O 17 − δ

We present the magnetic, thermodynamic, and muon spin relaxation ( μ SR ) results of the dimer-based triangular antiferromagnet Ba 6 Y 2 Rh 2 Ti 2 O 17 − δ . The magnetic susceptibility data show the sub-Curie-Weiss behavior χ ( T ) ∝ T − α χ below 100 K, suggesting random magnetism. The isothermal magnetization results reveal the presence of weakly interacting structural orphan spins about 6.1 % at 2 K, arising from the oxygen deficiency. The comprehensive μ SR experiments exhibit the coexisting relaxing and nonrelaxing components along with the thermally activated behavior in the muon spin relaxation rate, reflecting the fluctuating orphan spins in the dimer singlet background. In addition, we observe the scaling behavior of M ( H , T ) in H / T and P z ( t ) in t / H LF with the scaling exponents α χ = α M = 0.75 and α μ = 0.72 , respectively, but not for the magnetic specific heat data. The failure of the scaling relation in C m ( H , T ) / T implies low-energy excitations dressed by the conventional orphan spins. Based on these observations, we find that the magnetic ground state resembles random singlets and discuss the possible configurations of the spin dimer unit Rh 2 O 9 . Our results shed light on the role of quenched disorder in the dimer-based frustrated magnets. Published by the American Physical Society 2024

Lee, Wonjun (ORCID:000000034848852X)↗

Pressure-induced irreversible volume collapse in a high-entropy alloy

At ambient conditions, the high-entropy alloy superconductor R⁢e 0.6⁢ (NbTiZrHf) 0.4 exhibits exceptional mechanical properties among high-entropy alloys, with its hexagonal phase achieving nanoindentation hardness of 18.5 GPa. We report on a unique pressure-induced structural transformation from a hexagonal phase to a body-centered cubic (BCC) phase, revealed by synchrotron x-ray diffraction measurements up to 70 GPa. This first-order transition, accompanied by a 6.1% volume collapse, occurs at 44 GPa and results in a BCC structure with random site occupancy by the five constituent elements, which is remarkably retained upon decompression to ambient conditions. The transformation proceeds via a martensiticlike, diffusionless mechanism without elemental segregation, enabled by pressure-induced electronic redistribution and atomic-scale disorder. These findings demonstrate a rare case of metastable phase retention in a chemically complex alloy and offer new insights into structure-stability relationships under pressure.

Alloys↗

Determination of uncertainties of PWR spent fuel radionuclide inventory based on real operational history data

A requisite for the official approval of the safe final disposal of SNF is a comprehensive specification and declaration of the nuclear inventory in SNF by the waste supplier. In the verification process both the values of the radionuclide (RN) activities and their uncertainties are required. Burn-up (BU) calculations based on typical and generic reactor operational parameters do not encompass any possible uncertainties observed in real reactor operations. At the same time, the details of the irradiation history are often not well known, which complicates the assessment of declared RN inventories. Here, we have compiled a set of burnup calculations accounting for the operational history of 339 published or anonymized real PWR fuel assemblies (FA). These histories were used as a basis for a 'SRP analysis', to provide information about the range of the values of the associated secondary reactor parameters (SRP's). Hence, we can calculate the realistic variation or spectrum of RN inventories. SCALE 6.1 has been employed for the burn-up calculations. The results have been validated using experimental data from the online database - SFCOMPO-1 and -2. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Performance MnBi Alloy Prepared Using Profiled Heat Treatment

The profiled heat treatment (PHT) method has been used to synthesize MnBi alloys with high-purity low-temperature phase (LTP). In the PHT method, the arc-melted MnBi alloy was remelted then slowly cooled by a pseudo-equilibrium solidification process to promote the formation of LTP phase. The PHT-treated MnBi alloys had an LTP phase up to 94 wt.% and a magnetization of 73 emu/g under a field of 9 T. Scanning electron microscopy showed that there exist some micrometer-sized Mn-rich inclusions in the LTP matrix of the PHT MnBi alloy. The PHT MnBi alloys were crushed into powders with an average size of ~3 μm by low-energy ball milling. These MnBi powders were aligned in an 18 kOe field and warm compacted into a bulk magnet at 300 °C for 30 min. The magnet had a density of 8.2 g/cm3 and magnetic properties of Ms = 6.7 kG, Mr = 5.3 kGs, i Hc = 5 kOe, and (BH)max = 6.1 MGOe

MnBi↗

Time-Resolved Thomson Scattering on Gas-Puff Z-Pinch Plasmas at Pinch Time

The conditions and dynamics of neon gas puff Z-pinch plasmas at pinch time are studied on a pulsed power generator with a current rise time of approximately 200-ns and 0.9-mA peak current. Radial tailoring of the gas puff massdensity profile using a triple-nozzle coaxial valve (two annular gas liners and a central jet) allows production of both more stable and less stable (with regard to the magneto-Rayleigh– Taylor instability) Z-pinch implosions. A 526.5-nm, 10-J Thomson scattering diagnostic laser enables probing of the flow dynamics and plasma conditions of these implosions with both spatial and temporal resolutions. The 2.2-ns laser pulse scatters from the plasma electrons and is carried by one optical fiber to a visible light streak camera, and by a bundle of optical fibers to a time-gated camera, both after spectral dispersion by 750-mm spectrometers. The streak camera, with a 10-ns full streak time, provides subnanosecond resolution of the evolution of the pinch plasma parameters through stagnation. The timegated camera provides spatially resolved spectra (across a field of view of 6.1 mm) at the same time as the streak. Scattering spectra suggest that temperatures are high at stagnation, with the ion temperature as much as three times higher than the electron temperature. Furthermore, we consider the possibility of nonthermal explanations for the broad scattering spectra and high effective ion temperature, including collisionality, implosion velocity distributions (velocity gradients), and small-scale hydrodynamic motion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Clinical characteristics and aetiological analysis of 133 patients for pulmonary embolism combined with haemoptysis

Abstract Background In the patients with pulmonary embolism (PE), PE itself can cause haemoptysis and other reasons can also cause haemoptysis. Therefore, the clinical characteristics and the causes of haemoptysis are lacking. Methods A retrospective analysis was performed that involved screening 583 PE patients and determining that haemoptysis occurred in 141 cases. Of these, eight cases were omitted due to anticoagulation‐related haemoptysis or unavailable data, leaving 133 cases that were enrolled in final analysis (127 acute and 6 chronic case of PE). We classified the acute PE patients who combined with diseases which can cause haemoptysis to non‐simple group (n = 61) and those without these diseases to simple group (n = 66). Results The incidence of haemoptysis in PE patients was 23.75%. In the simple group, the amount of haemoptysis ≤ 5 mL was 80.30% (53/66) and ≤ 20 mL was 90.91% (60/66). In the non‐simple group who combined with lung cancer, the amount of haemoptysis ≤ 5 mL was 68.4% (26/38) and ≤ 20 mL was 86.8% (33/38). Further analyses revealed that the amount of haemoptysis in the non‐simple group was larger than that in the simple group (median 5 [5‐125] vs. 5 [5‐5], p < 0.001; volume ≥ 100 mL: 29.5% vs. 6.1%, p < 0.001). Among all the PE patients, chronic thromboembolic pulmonary hypertension (CTEPH), PE combined with tuberculosis (TB) and PE combined with bronchiectasis were independent risk factors for the amount of haemoptysis ≥ 100 mL (OR = 15.00, (95% CI: 2.235‐100.652); 12.00, (3.101‐46.437); 60.00, (6.552‐549.441), respectively). Conclusions The haemoptysis caused by acute PE or PE combined with lung cancer was mild and was characterised by blood in sputum. PE combined with TB, bronchiectasis and CTEPH are associated with moderate to massive haemoptysis, with a greater risk of haemoptysis ≥ 100 mL.

Zou, Yong Wei↗

Valuation of ecosystem services in alternative bioenergy landscape scenarios

Abstract Agricultural land in the Midwest is a source of food and fuel, as well as biodiversity. It is also a cause of excess nutrients that make their way to the Mississippi River and the Gulf of Mexico. To address unsustainable changes to biogeochemical cycles and ecosystem functions, a multidisciplinary approach involving social science, natural science, and engineering is often effective. Given the potential of second‐generation biofuels, and capitalizing on the deep‐rooted perennial bioenergy crops capable of thriving in poor soils, we demonstrated an integrated socio‐environmental analysis of the impacts of growing switchgrass within row‐crop landscapes in Illinois. In this study, we model land use scenarios that incorporate switchgrass as a biofuel crop in a Midwest corn‐belt watershed using the Soil Water Assessment Tool coupled with an economic analysis for the Vermilion Basin in Illinois. We estimated the values of ecosystem services under an alternative bioenergy landscape, including commodity and bioenergy crops, changes in biogeochemistry, and recreational services. The estimated annual values of nitrate and sediment reduction attributed to bioenergy crops range from $38 million to $97 million and $16,000 to $197,000, respectively. The annual value of carbon dioxide emission reduction ranges from $1.8 million to $6.1 million based on the initial crop rotation pattern. Estimated average annual values for wildlife viewing, water‐based recreation, and pheasant hunting are $1.24 million, $0.17 million, and $0.3 million, respectively. To our knowledge, this study represents the first effort to comprehensively quantify ecosystem services using a process‐based model, and estimate their value in an alternative bioenergy landscape. The information we generate could aid in understanding the potential for biomass production from marginal land and the total economic value of the landscape at various spatial scales. The framework is useful in fostering alternative bioenergy landscapes with synergies in a food, energy, and conservation nexus.

54 ENVIRONMENTAL SCIENCES↗

Properties of original impactors estimated from three-dimensional analysis of whole Stardust tracks

The Stardust mission captured comet Wild 2 particles in aerogel at 6.1 km s{sup -1}. We performed high-resolution three-dimensional imaging and X-ray fluorescence mapping of whole cometary tracks in aerogel. We present the results of a survey of track structures using laser scanning confocal microscopy, including measurements of track volumes, entry hole size, and cross-sectional profiles. We compare various methods for measuring track parameters. We demonstrate a methodology for discerning hypervelocity particle ablation rates using synchrotron-based X-ray fluorescence, combined with mass and volume estimates of original impactors derived from measured track properties. Finally, we present a rough framework for reconstruction of original impactor size, and volume of volatilized material, using our measured parameters. The bulk of this work is in direct support of nondestructive analysis and identification of cometary grains in whole tracks, and its eventual application to the reconstruction of the size, shape, porosity, and chemical composition of whole Stardust impactors.

79 ASTRONOMY AND ASTROPHYSICS↗

Sweeping Jet Film Cooling on a Turbine Vane

The cooling performance of sweeping jet film cooling was studied on a turbine vane suction surface in a low-speed linear cascade wind tunnel. The sweeping jet holes consist of fluidic oscillators with an aspect ratio (AR) of unity and a hole spacing of Pd/D = 6. Infrared (IR) thermography was used to estimate the adiabatic film effectiveness at several blowing ratios and two different freestream turbulence levels (Tu = 0.3% and 6.1%). Convective heat transfer coefficient was measured by a transient IR technique, and the net heat flux benefit was calculated. The total pressure loss due to sweeping jet film cooling was characterized by traversing a total pressure probe at the exit plane of the cascade. Tests were performed with a baseline shaped hole (SH) (777-shaped hole) for comparison. The sweeping jet hole showed higher adiabatic film effectiveness than the 777-shaped hole in the near hole region. Although the unsteady sweeping action of the jet augments heat transfer, the net positive cooling benefit is higher for sweeping jet holes compared to 777 hole at particular flow conditions. The total pressure loss measurement showed a 12% increase in total pressure loss at a blowing ratio of M = 1.5 for sweeping jet hole, while 777-shaped hole showed a 8% total pressure loss increase at the corresponding blowing ratio.

Engineering↗

Flow and Heat Transfer Experimental Study for 3D-Printed Solar Receiving Tubes With Helical Fins at Internal Surface

3D-printing technology was applied to fabricate novel solar thermal collection tubes that have internal heat transfer enhancement fins and external surfaces with high solar absorptivity and low emissivity due to the ability to use different materials in one tube. Helical fins were selected to introduce circumferential flow and thus minimize the circumferential temperature difference of the tube that receives sunlight on one side. The structures of the helical fins were previously optimized from computational fluid dynamics (CFD) analysis with the objective of low entropy production rate by looking for high heat transfer coefficient and relatively lower pressure loss. High-temperature alloy, Inconel-718, was used to 3D print the tubes, which can resist corrosion for the potential application of molten chloride salts as heat transfer fluid. Experimental tests were carried out using water as the heat transfer fluid with the high heat flux provided by a tubular furnace heater. The tested Reynolds number ranges from 3.9 × 10 3 to 6.1 × 10 4 . Heat transfer coefficients of up to 2.8 times that of the smooth tube could be obtained with the expense of increased pressure loss compared to that of the smooth tube. The total system entropy generation can be significantly reduced due to the benefit of heat transfer enhancement that is greater than the expenses of the increased pressure loss. The experimental results of the 3D-printed heat transfer tubes confirmed the CFD-based results of fin optimization. Furthermore, the novel heat transfer tube is recommended for application in concentrating solar power systems.

14 SOLAR ENERGY↗

Highly piezoelectric AlN thin films grown on amorphous, insulating substrates

AlN thin films were grown by reactive sputtering on amorphous SiO{sub 2} thin films. Film texture, x-ray rocking curve width, mechanical stress, and the clamped piezoelectric constant d{sub 33,f} were studied as a function of rf bias power and substrate roughness. A high d{sub 33,f} of 5.0 pm/V was achieved at low substrate roughness and low mechanical AlN film stress. Increasing substrate roughness and stress leads to a deterioration of d{sub 33,f}, which is correlated with a higher density of opposite polarity grains detected by piezoresponse force microscopy. Extrapolating to 100% uniform polarity, a d{sub 33,f} of 6.1 pm/V is derived as highest possible value, probably corresponding to the d{sub 33,f}=e{sub 33}/c{sub 33}{sup E} of perfect single crystalline material. Growth mechanisms are proposed and underlined by high resolution transmission electron microscopy to explain the observed phenomena.

36 MATERIALS SCIENCE↗

Highly conductive indium zinc oxide prepared by reactive magnetron cosputtering technique using indium and zinc metallic targets

Zn-doped In{sub 2}O{sub 3} film is frequently deposited from an oxide target; but the use of metallic target is increasingly expected as preparing the film with comparable properties. This work aimed to prepare a highly conductive and transparent Zn-doped In{sub 2}O{sub 3} thin film on Corning Eagle{sup 2000} glass substrate by magnetron cosputtering method using indium and zinc targets. Structural characterization was performed using x-ray diffraction and x-ray photoelectron spectroscopy. The film had an amorphous structure when the film was prepared on an unheated substrate, but had an In{sub 2}O{sub 3} polycrystalline structure when the film was deposited on 150 and 300 deg. C substrates. The electrical properties of the film were greatly affected by annealing; the Zn-doped In{sub 2}O{sub 3} film had a low resistivity of 6.1x10{sup -4} {Omega} cm and an average transmittance of 81.7% when the film was deposited without substrate heating and followed a 600 deg. C annealing.

36 MATERIALS SCIENCE↗

Ultrathin polycrystalline 6,13-Bis(triisopropylsilylethynyl)-pentacene films

Ultrathin (<6 nm) polycrystalline films of 6,13-bis(triisopropylsilylethynyl) pentacene (TIPS-P) are deposited with a two-step spin-coating process. The influence of spin-coating conditions on morphology of the resulting film was examined by atomic force microscopy. Film thickness and RMS surface roughness were in the range of 4.0–6.1 and 0.6–1.1 nm, respectively, except for small holes. Polycrystalline structure was confirmed by grazing incidence x-ray diffraction measurements. Near-edge x-ray absorption fine structure measurements suggested that the plane through aromatic rings of TIPS-P molecules was perpendicular to the substrate surface.

36 MATERIALS SCIENCE↗

Dosimetric uncertainty in prostate cancer proton radiotherapy

Purpose: The authors we evaluate the uncertainty in proton therapy dose distribution for prostate cancer due to organ displacement, varying penumbra width of proton beams, and the amount of rectal gas inside the rectum. Methods and Materials: Proton beam treatment plans were generated for ten prostate patients with a minimum dose of 74.1 cobalt gray equivalent (CGE) to the planning target volume (PTV) while 95% of the PTV received 78 CGE. Two lateral or lateral oblique proton beams were used for each plan. The authors we investigated the uncertainty in dose to the rectal wall (RW) and the bladder wall (BW) due to organ displacement by comparing the dose-volume histograms (DVH) calculated with the original or shifted contours. The variation between DVHs was also evaluated for patients with and without rectal gas in the rectum for five patients who had 16 to 47 cc of visible rectal gas in their planning computed tomography (CT) imaging set. The uncertainty due to the varying penumbra width of the delivered protons for different beam setting options on the proton delivery system was also evaluated. Results: For a 5 mm anterior shift, the relative change in the RW volume receiving 70 CGE dose (V{sub 70}) was 37.9% (5.0% absolute change in 13.2% of a mean V{sub 70}). The relative change in the BW volume receiving 70 CGE dose (V{sub 70}) was 20.9% (4.3% absolute change in 20.6% of a mean V{sub 70}) with a 5 mm inferior shift. A 2 mm penumbra difference in beam setting options on the proton delivery system resulted in the relative variations of 6.1% (0.8% absolute change) and 4.4% (0.9% absolute change) in V{sub 70} of RW and BW, respectively. The data show that the organ displacements produce absolute DVH changes that generally shift the entire isodose line while maintaining the same shape. The overall shape of the DVH curve for each organ is determined by the penumbra and the distance of the target in beam's eye view (BEV) from the block edge. The beam setting option producing a 2 mm sharper penumbra at the isocenter can reduce the magnitude of maximal doses to the RW by 2% compared to the alternate option utilizing the same block margin of 7 mm. The dose to 0.1 cc of the femoral head on the distal side of the lateral-posterior oblique beam is increased by 25 CGE for a patient with 25 cc of rectal gas. Conclusion: Variation in the rectal and bladder wall DVHs due to uncertainty in the position of the organs relative to the location of sharp dose falloff gradients should be accounted for when evaluating treatment plans. The proton beam delivery option producing a sharper penumbra reduces maximal doses to the rectal wall. Lateral-posterior oblique beams should be avoided in patients prone to develop a large amount of rectal gas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for optimizing LINAC treatment geometry for volumetric modulated arc therapy of multiple brain metastases

Purpose: Volumetric modulated arc therapy (VMAT) is a rotational delivery technique in which MLC shapes, dose rate, and gantry rotation speed are optimized to produce conformal dose distributions. The aim of this work is to develop a beam projection method for deriving the optimal table and collimator angles for multilesion treatment planning. Methods: The method consists of four steps. The first step is to define the vector of beam-eye-view (BEV)-Y-axis in the treatment planning CT coordinates. The second step is to project each target onto the BEV-Y-axis vector. In the third step, the best table and collimator angle are found with a brute-force optimization technique that minimizes MLC leaf sharing between lesions. The fourth step is to generate an optimized VMAT plan with appropriate table/collimator angles and evaluate the plan quality. Results: The authors tested the method on three example cases with targets of various locations in the brain and sizes ranging from 1.18 to 17.86 cm{sup 3}. Applying the optimized geometric parameter to generate VMAT plan, a reduction of the 12 Gy volume was more than 6.1% for all cases; the plan homogeneity (D{sub 2%}-D{sub 95%}) was improved from 5.88{+-}1.21 to 5.21{+-}0.93 Gy vs a VMAT plan with the manufacturer recommended table and collimator angles. Conclusions: The authors conclude that the use of the projection method minimizes the sharing of MLC leaves between lesions and improves the plan quality for multilesion VMAT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-GG-T-49: Real Time Dose Verification for Novel Shielded Balloon Brachytherapy

Purpose: The validation of a novel approach for reducing skindoses to an acceptable level during Accelerated Partial Breast Irradiation (APBI) when the balloon-to-skin distance is inadequate (less than 7 mm) is reported. The study uses a real time dose verification method for a metallic shielded balloon applicator using scintillation fiber technology. Method and Materials: Partial shielding of the radiationdose to the skin using iron or other ferrous powder could enable the extension of APBI to some patients. With small external and pre-determined magnetic fields (<few Gauss), the metallic elements deposition can be controlled on the inner surface of a balloon. Geant4 simulations were used to generate an attenuation dose curve for various radiation lengths after cross-calibration with dedicated data acquired at Jefferson Lab. Some powder was then injected into various inflated MammoSite and rectal balloons within realistic breast and torso phantoms of differing sizes. The dose on the external surface of the skin was measured from a 6.1 Ci {sup 192}Ir of a GammaMed 12i afterloader unit, with a MOSFET,ion chamber and scintillating fiber array detectors. Results: Realistic Monte Carlo simulation studies for the amount and distribution of the required shielding material were compared to dedicated phantom data. A decrease of the skindose was measured to an acceptable level (~350-450 cGy) during standard breast Brachytherapy treatments with relatively weak magnetic fields. Additional measurements provided negligible corrections (< few %) on the saline water density from the suspended ironpowder.Conclusion: This project opens the possibility to increasing the survival expectancy and minimizing negative side effects during brachytherapy treatments, as well as improving cosmetic outcome for all APBI patients. The proposed method may also be used in other procedures for brain, heart, rectal, or vaginal cancers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector

Purpose: The goal of this study is to evaluate a new method based on a coded aperture mask combined with a digital x-ray imaging detector for measurements of the focal spot sizes of diagnostic x-ray tubes. Common techniques for focal spot size measurements employ a pinhole camera, a slit camera, or a star resolution pattern. The coded aperture mask is a radiation collimator consisting of a large number of apertures disposed on a predetermined grid in an array, through which the radiation source is imaged onto a digital x-ray detector. The method of the coded mask camera allows one to obtain a one-shot accurate and direct measurement of the two dimensions of the focal spot (like that for a pinhole camera) but at a low tube loading (like that for a slit camera). A large number of small apertures in the coded mask operate as a ''multipinhole'' with greater efficiency than a single pinhole, but keeping the resolution of a single pinhole. Methods: X-ray images result from the multiplexed output on the detector image plane of such a multiple aperture array, and the image of the source is digitally reconstructed with a deconvolution algorithm. Images of the focal spot of a laboratory x-ray tube (W anode: 35-80 kVp; focal spot size of 0.04 mm) were acquired at different geometrical magnifications with two different types of digital detector (a photon counting hybrid silicon pixel detector with 0.055 mm pitch and a flat panel CMOS digital detector with 0.05 mm pitch) using a high resolution coded mask (type no-two-holes-touching modified uniformly redundant array) with 480 0.07 mm apertures, designed for imaging at energies below 35 keV. Measurements with a slit camera were performed for comparison. A test with a pinhole camera and with the coded mask on a computed radiography mammography unit with 0.3 mm focal spot was also carried out. Results: The full width at half maximum focal spot sizes were obtained from the line profiles of the decoded images, showing a focal spot of 0.120 mmx0.105 mm at 35 kVp and M=6.1, with a detector entrance exposure as low as 1.82 mR (0.125 mA s tube load). The slit camera indicated a focal spot of 0.112 mmx0.104 mm at 35 kVp and M=3.15, with an exposure at the detector of 72 mR. Focal spot measurements with the coded mask could be performed up to 80 kVp. Tolerance to angular misalignment with the reference beam up to 7 deg. in in-plane rotations and 1 deg. deg in out-of-plane rotations was observed. The axial distance of the focal spot from the coded mask could also be determined. It is possible to determine the beam intensity via measurement of the intensity of the decoded image of the focal spot and via a calibration procedure. Conclusions: Coded aperture masks coupled to a digital area detector produce precise determinations of the focal spot of an x-ray tube with reduced tube loading and measurement time, coupled to a large tolerance in the alignment of the mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗