Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D Visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

An MCNP6 Version of the Visual Editor - Paper 2

The Visual Editor is a graphical user interface for working with the MCNP computer code developed at Los Alamos National Laboratory. It consists of a graphical user interface written in C++ that is linked directory to the MCNP Fortran code. Work on the original Visual Editor started in 1992 and was first published in 1993. The original version of the Visual Editor was created on Unix/Linux operating systems and was linked to the MCNP computer code. The Visual Editor was adapted to the Windows operating system in 1999. In 2008 the Visual Editor was adapted to work with the MCNPX computer code. This paper discusses the latest upgrade of the Visual Editor to be compatible with the MCNP6 computer code. Two graphical user interfaces have been created, the Visual MCNP6 Plotter and the Visual MCNP6 Editor. The Visual MCNP6 Plotter includes all of the standard plotting features available in the default MCNP6 plotting package including geometry plotting, tally plotting, cross section plotting, mesh tally plotting and weight window mesh plotting. The Visual MNCP6 Editor has additional capabilities to allow for the creation of MCNP input files with graphical tools. The Visual MCNP6 Editor allows user to create and modify the input file within the Editor. Modifications are not allowed in the Visual MCNP6 Plotter. Both graphical user interfaces allow for advanced plotting features including 3D geometry plots and particle track plotting. Complete details on these tools along with their current status can be found at the Visual Editor website (www.mcnpvised.com). (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

The Spatial Extent and Distribution of Star Formation in 3D-HST Mergers at z is approximately 1.5

We present an analysis of the spatial distribution of star formation in a sample of 60 visually identified galaxy merger candidates at z greater than 1. Our sample, drawn from the 3D-HST survey, is flux-limited and was selected to have high star formation rates based on fits of their broad-band, low spatial resolution spectral energy distributions. It includes plausible pre-merger (close pairs) and post-merger (single objects with tidal features) systems,with total stellar masses and star formation rates derived from multi-wavelength photometry. Here we use near-infrared slitless spectra from 3D-HST which produce H or [OIII] emission line maps as proxies for star-formation maps. This provides a first comprehensive high-resolution, empirical picture of where star formation occurred in galaxy mergers at the epoch of peak cosmic star formation rate. We find that detectable star formation can occur in one or both galaxy centres, or in tidal tails. The most common case (58%) is that star formation is largely concentrated in a single, compact region, coincident with the centre of (one of) the merger components. No correlations between star formation morphology and redshift, total stellar mass, or star formation rate are found. A restricted set of hydrodynamical merger simulationsbetween similarly massive and gas-rich objects implies that star formation should be detectable in both merger components, when the gas fractions of the individual components are the same. This suggests that z is approximately 1.5 mergers typically occur between galaxies whose gas fractions, masses, andor star formation rates are distinctly different from one another.

Spatial↗

TH-EF-BRA-11: Feasibility of Super-Resolution Time-Resolved 4DMRI for Multi-Breath Volumetric Motion Simulation in Radiotherapy Planning

Purpose: To develop a novel super-resolution time-resolved 4DMRI technique to evaluate multi-breath, irregular and complex organ motion without respiratory surrogate for radiotherapy planning. Methods: The super-resolution time-resolved (TR) 4DMRI approach combines a series of low-resolution 3D cine MRI images acquired during free breathing (FB) with a high-resolution breath-hold (BH) 3DMRI via deformable image registration (DIR). Five volunteers participated in the study under an IRB-approved protocol. The 3D cine images with voxel size of 5×5×5 mm{sup 3} at two volumes per second (2Hz) were acquired coronally using a T1 fast field echo sequence, half-scan (0.8) acceleration, and SENSE (3) parallel imaging. Phase-encoding was set in the lateral direction to minimize motion artifacts. The BH image with voxel size of 2×2×2 mm{sup 3} was acquired using the same sequence within 10 seconds. A demons-based DIR program was employed to produce super-resolution 2Hz 4DMRI. Registration quality was visually assessed using difference images between TR 4DMRI and 3D cine and quantitatively assessed using average voxel correlation. The fidelity of the 3D cine images was assessed using a gel phantom and a 1D motion platform by comparing mobile and static images. Results: Owing to voxel intensity similarity using the same MRI scanning sequence, accurate DIR between FB and BH images is achieved. The voxel correlations between 3D cine and TR 4DMRI are greater than 0.92 in all cases and the difference images illustrate minimal residual error with little systematic patterns. The 3D cine images of the mobile gel phantom preserve object geometry with minimal scanning artifacts. Conclusion: The super-resolution time-resolved 4DMRI technique has been achieved via DIR, providing a potential solution for multi-breath motion assessment. Accurate DIR mapping has been achieved to map high-resolution BH images to low-resolution FB images, producing 2Hz volumetric high-resolution 4DMRI. Further validation and improvement are still required prior to clinical applications. This study is in part supported by the NIH (U54CA137788/U54CA132378).

60 APPLIED LIFE SCIENCES↗

Understanding Dynamical Systems in High-Dimensional Parameter Spaces (Final Report)

In the last few decades, computational models, especially of the complex dynamical systems of greatest interest, i.e., climate, high energy density science, combustion, etc. have become increasingly accurate and sophisticated. Consequently, they are now routinely used to predict outcomes of experiments or to inform design decisions. However, many such simulations depend on a (large) number of parameters in order to, for example, approximate physical phenom whose exact solution is unknown or describe material properties in situations with little or no experimental data. Choosing these parameters and understanding how the outcomes of such a simulation changes with respect to the inputs are rapidly becoming some of the primary challenges in many application areas. Simulations have long been too complex for humans to fully comprehend and thus are often treated as black-box systems. The inputs to the systems are typically a collection of parameters with expert-selected ranges, and the outputs are various quantities of interest (QoIs) describing the performance of the system. Therefore, the fundamental challenge can be described as one of understanding a high-dimensional (many input parameters), multi-variate (many QoIs) function. Unfortunately, existing analysis tools are only of limited use for this task as most techniques can neither deal with many input dimensions nor offer opportunities to jointly study several QoIs. Furthermore, data analysis has long relied on an exploratory process in which scientist first visualize the available data, for example, using scatter plots or 3D renderings, form new hypotheses on some phenomena of interest, and subsequently test these hypotheses using dedicated analysis or statistics approaches. However, for high-dimensional functions this exploration is difficult if not impossible using existing tools as there are too many QoIs to simultaneously observe, and visualizations of high-dimensional spaces are abstract and difficult to understand if they exist at all. The goal of this project is to build new analysis techniques and tool that offer high level insights for exploring high-dimensional scientific data. And to extend existing approach beyond single scalar functions and instead consider multiple QoIs simultaneously.

97 MATHEMATICS AND COMPUTING↗

TU-H-CAMPUS-IeP2-05: Breast and Soft Tissue-Equivalent 3D Printed Phantoms for Imaging and Dosimetry

Purpose: The study has the goal to demonstrate that breast and soft tissue-equivalent phantoms for dosimetry applications in the diagnostic energy range can be fabricated using common 3D printing methods. Methods: 3D printing provides the opportunity to rapidly prototype uniquely designed objects from a variety of materials. Common 3D printers are usually limited to printing objects based on thermoplastic materials such as PLA, or ABS. The most commonly available plastic is PLA, which has a density significantly greater than soft tissue. We utilized a popular 3D printer to demonstrate that tissue specific phantom materials can be generated through the careful selection of 3D printing parameters. A series of stepwedges were designed and printed using a Makerbot Replicator2 3D printing system. The print file provides custom adjustment of the infill density, orientation and position of the object on the printer stage, selection of infill patterns, and other control parameters. The x-ray attenuation and uniformity of fabricated phantoms were evaluated and compared to common tissue-equivalent phantom materials, acrylic and BR12. X-ray exposure measurements were made using narrow beam geometry on a clinical mammography unit at 28 kVp on the series of phantoms. The 3D printed phantoms were imaged at 28 kVp to visualize the internal structure and uniformity in different planes of the phantoms. Results: By utilizing specific in-fill density and patterns we are able to produce a phantom closely matching the attenuation characteristics of BR12 at 28 kVp. The in-fill patterns used are heterogeneous, so a judicious selection of fill pattern and the orientation of the fill pattern must be made in order to obtain homogenous attenuation along the intended direction of beam propagation. Conclusions: By careful manipulation of the printing parameters, breast and soft tissue-equivalent phantoms appropriate for use at imaging energies can be fabricated using 3D printing techniques.

60 APPLIED LIFE SCIENCES↗

3D localization of electrophysiology catheters from a single x-ray cone-beam projection

Purpose: X-ray images allow the visualization of percutaneous devices such as catheters in real time but inherently lack depth information. The provision of 3D localization of these devices from cone beam x-ray projections would be advantageous for interventions such as electrophysiology (EP), whereby the operator needs to return a device to the same anatomical locations during the procedure. A method to achieve real-time 3D single view localization (SVL) of an object of known geometry from a single x-ray image is presented. SVL exploits the change in the magnification of an object as its distance from the x-ray source is varied. The x-ray projection of an object of interest is compared to a synthetic x-ray projection of a model of said object as its pose is varied. Methods: SVL was tested with a 3 mm spherical marker and an electrophysiology catheter. The effect of x-ray acquisition parameters on SVL was investigated. An independent reference localization method was developed to compare results when imaging a catheter translated via a computer controlled three-axes stage. SVL was also performed on clinical fluoroscopy image sequences. A commercial navigation system was used in some clinical image sequences for comparison. Results: SVL estimates exhibited little change as x-ray acquisition parameters were varied. The reproducibility of catheter position estimates in phantoms denoted by the standard deviations, (σ{sub x}, σ{sub y}, σ{sub z}) = (0.099 mm, 0.093 mm, 2.2 mm), where x and y are parallel to the detector plane and z is the distance from the x-ray source. Position estimates (x, y, z) exhibited a 4% systematic error (underestimation) when compared to the reference method. The authors demonstrated that EP catheters can be tracked in clinical fluoroscopic images. Conclusions: It has been shown that EP catheters can be localized in real time in phantoms and clinical images at fluoroscopic exposure rates. Further work is required to characterize performance in clinical images as well as the sensitivity to clinical image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-E-18C-04: Advanced Computer Simulation and Visualization Tools for Enhanced Understanding of Core Medical Physics Concepts

Purpose: Most medical physics programs emphasize proficiency in routine clinical calculations and QA. The formulaic aspect of these calculations and prescriptive nature of measurement protocols obviate the need to frequently apply basic physical principles, which, therefore, gradually decay away from memory. E.g. few students appreciate the role of electron transport in photon dose, making it difficult to understand key concepts such as dose buildup, electronic disequilibrium effects and Bragg-Gray theory. These conceptual deficiencies manifest when the physicist encounters a new system, requiring knowledge beyond routine activities. Methods: Two interactive computer simulation tools are developed to facilitate deeper learning of physical principles. One is a Monte Carlo code written with a strong educational aspect. The code can “label” regions and interactions to highlight specific aspects of the physics, e.g., certain regions can be designated as “starters” or “crossers,” and any interaction type can be turned on and off. Full 3D tracks with specific portions highlighted further enhance the visualization of radiation transport problems. The second code calculates and displays trajectories of a collection electrons under arbitrary space/time dependent Lorentz force using relativistic kinematics. Results: Using the Monte Carlo code, the student can interactively study photon and electron transport through visualization of dose components, particle tracks, and interaction types. The code can, for instance, be used to study kerma-dose relationship, explore electronic disequilibrium near interfaces, or visualize kernels by using interaction forcing. The electromagnetic simulator enables the student to explore accelerating mechanisms and particle optics in devices such as cyclotrons and linacs. Conclusion: The proposed tools are designed to enhance understanding of abstract concepts by highlighting various aspects of the physics. The simulations serve as virtual experiments that give deeper and long lasting understanding of core principles. The student can then make sound judgements in novel situations encountered beyond routine clinical activities.

60 APPLIED LIFE SCIENCES↗

EGS Collab Experiment 1: 3D Seismic Velocity Model and Updated Microseismic Catalog from Double-Difference Seismic Tomography

This package contains a 3D Seismic velocity model and an updated microseismic catalog obtained for a double-difference seismic tomography study. The 3D_seismic_velocity_model text file contains x (m), y(m), z(m), P-wave velocity (km/s), P-wave velocity quality indicator (1 for well-constrained; 0 for poorly constrained), S-wave velocity (km/s), and S-wave velocity quality indicator (1 for well-constrained; 0 for poorly constrained). The Updated_MEQ_catalog text file contains event origin time, x(m), y(m), z(m), error in x (m), error in y (m), error in z (m), and RMS misfit (millisecond). The 3D_seismic_P-wave_velocity_model animation file shows slices of the 3D P-wave velocity model. The 3D_seismic_S-wave_velocity_model animation file shows slices of the 3D S-wave velocity model. The Interactive_MEQ_location_comparison API file is an interactive visualization of the updated microseismic event locations and the original seismic catalog. The visualization allows users to view and compare the event locations by dragging, rotating, and zooming in. An updated version of 3D_seismic_velocity_model and associated animations were included, which were calculated with a more strict assumption for quality indicators.

15 GEOTHERMAL ENERGY↗

SU-F-T-275: A Correlation Study On 3D Fluence-Based QA and 2D Dose Measurement-Based QA

Purpose: The aim of this paper was to demonstrate the feasibility and creditability of computing and verifying 3D fluencies to assure IMRT and VMAT treatment deliveries, by correlating the passing rates of the 3D fluence-based QA (P(ά)) to the passing rates of 2D dose measurementbased QA (P(Dm)). Methods: 3D volumetric primary fluencies are calculated by forward-projecting the beam apertures and modulated by beam MU values at all gantry angles. We first introduce simulated machine parameter errors (MU, MLC positions, jaw, gantry and collimator) to the plan. Using passing rates of voxel intensity differences (P(Ir)) and 3D gamma analysis (P(γ)), calculated 3D fluencies, calculated 3D delivered dose, and measured 2D planar dose in phantom from the original plan are then compared with those from corresponding plans with errors, respectively. The correlations of these three groups of resultant passing rates, i.e. 3D fluence-based QA (P(ά,Ir) and P(ά,γ)), calculated 3D dose (P(Dc,Ir) and P(Dc,γ)), and 2D dose measurement-based QA (P(Dm,Ir) and P(Dm,γ)), will be investigated. Results: 20 treatment plans with 5 different types of errors were tested. Spearman’s correlations were found between P(ά,Ir) and P(Dc,Ir), and also between P(ά,γ) and P(Dc,γ), with averaged p-value 0.037, 0.065, and averaged correlation coefficient ρ-value 0.942, 0.871 respectively. Using Matrixx QA for IMRT plans, Spearman’s correlations were also obtained between P(ά,Ir) and P(Dm,Ir) and also between P(ά,γ) and P(Dm,γ), with p-value being 0.048, 0.071 and ρ-value being 0.897, 0.779 respectively. Conclusion: The demonstrated correlations improve the creditability of using 3D fluence-based QA for assuring treatment deliveries for IMRT/VMAT plans. Together with advantages of high detection sensitivity and better visualization of machine parameter errors, this study further demonstrates the accuracy and feasibility of 3D fluence based-QA in pre-treatment QA and daily QA. Research reported in this study is supported by the Agency for Healthcare Research and Quality (AHRQ) under award 1R01HS0222888. The senior author received research grants from ViewRay Inc. and Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Experimental Investigation of the Near Wall Flow Structure of a Low Reynolds Number 3-D Turbulent Boundary Layer

Laser Doppler velocimetry (LDV) measurements and hydrogen bubble flow visualization techniques were used to examine the near-wall flow structure of 2D and 3D turbulent boundary layers (TBLs) over a range of low Reynolds numbers. The goals of this research were (1) an increased understanding of the flow physics in the near wall region of turbulent boundary layers,(2) to observe and quantify differences between 2D and 3D TBL flow structures, and (3) to document Reynolds number effects for 3D TBLs. The LDV data have provided results detailing the turbulence structure of the 2D and 3D TBLs. These results include mean Reynolds stress distributions, flow skewing results, and U and V spectra. Effects of Reynolds number for the 3D flow were also examined. Comparison to results with the same 3D flow geometry but at a significantly higher Reynolds number provided unique insight into the structure of 3D TBLs. While the 3D mean and fluctuating velocities were found to be highly dependent on Reynolds number, a previously defined shear stress parameter was discovered to be invariant with Reynolds number. The hydrogen bubble technique was used as a flow visualization tool to examine the near-wall flow structure of 2D and 3D TBLs. Both the quantitative and qualitative results displayed larger turbulent fluctuations with more highly concentrated vorticity regions for the 2D flow.

FLOW VISUALIZATION↗

Science Opportunity Analyzer (SOA) Version 8

SOA allows scientists to plan spacecraft observations. It facilitates the identification of geometrically interesting times in a spacecraft s orbit that a user can use to plan observations or instrument-driven spacecraft maneuvers. These observations can then be visualized multiple ways in both two- and three-dimensional views. When observations have been optimized within a spacecraft's flight rules, the resulting plans can be output for use by other JPL uplink tools. Now in its eighth major version, SOA improves on these capabilities in a modern and integrated fashion. SOA consists of five major functions: Opportunity Search, Visualization, Observation Design, Constraint Checking, and Data Output. Opportunity Search is a GUI-driven interface to existing search engines that can be used to identify times when a spacecraft is in a specific geometrical relationship with other bodies in the solar system. This function can be used for advanced mission planning as well as for making last-minute adjustments to mission sequences in response to trajectory modifications. Visualization is a key aspect of SOA. The user can view observation opportunities in either a 3D representation or as a 2D map projection. Observation Design allows the user to orient the spacecraft and visualize the projection of the instrument field of view for that orientation using the same views as Opportunity Search. Constraint Checking is provided to validate various geometrical and physical aspects of an observation design. The user has the ability to easily create custom rules or to use official project-generated flight rules. This capability may also allow scientists to easily assess the cost to science if flight rule changes occur. Data Output allows the user to compute ancillary data related to an observation or to a given position of the spacecraft along its trajectory. The data can be saved as a tab-delimited text file or viewed as a graph. SOA combines science planning functionality unique to both JPL and the sponsoring spacecraft. SOA is able to ingest JPL SPICE Kernels that are used to drive the tool and its computations. A Percy search engine is then included that identifies interesting time periods for the user to build observations. When observations are then built, flight-like orientation algorithms replicate spacecraft dynamics to closely simulate the flight spacecraft s dynamics. SOA v8 represents large steps forward from SOA v7 in terms of quality, reliability, maintainability, efficiency, and user experience. A tailored agile development environment has been built around SOA that provides automated unit testing, continuous build and integration, a consolidated Web-based code and documentation storage environment, modern Java enhancements, and a focus on usability

Witoff, Robert J.↗

SU-F-T-41: 3D MTP-TRUS for Prostate Implant

Purpose: Prostate brachytherapy is an effective treatment for early prostate cancer. The current prostate implant is limited to using 2D transrectal ultrassound (TRUS) or machenical motor driven 2D array either in the end or on the side. Real-time 3D images can improve the accuracy of the guidance of prostate implant. The concept of our system is to allow realtime full visualization of the entire prostate with the multiple transverse scan. Methods: The prototype of 3D Multiple-Transverse-Plane Transrectal Ultrasound probe (MTP-TRUS) has been designed by us and manufactured by Blatek inc. It has 7 convex linear arrays and each array has 96 elements. It is connected to cQuest Fire bird research system (Cephasonics inc.) which is a flexible and configurable ultrasound-development platform. The size of cQuest Firebird system is compact and supports the real-time wireless image transferring. A relay based mux board is designed for the cQuest Firebird system to be able to connect 672 elements. Results: The center frequency of probe is 6MHz±10%. The diameter of probe is 3cm and the length is 20cm. The element pitch is 0.205 mm. Array focus is 30mm and spacing 1.6cm. The beam data for each array was measured and met our expectation. The interface board of MTP-TURS is made and able to connect to cQuest Firebird system. The image display interface is still under the development. Our real-time needle tracking algorithm will be implemented too. Conclusion: Our MTP-TRUS system for prostate implant will be able to acquire real-time 3D images of prostate and do the real-time needle segmentation and tracking. The system is compact and have wireless function.

60 APPLIED LIFE SCIENCES↗

MolViewSpec: a Mol* extension for describing and sharing molecular visualizations

Data visualization is a pivotal component of a structural biologist’s arsenal. The Mol* Viewer makes molecular visualizations available to broader audiences via most web browsers. While Mol* provides a wide range of functionality, it has a steep learning curve and is only available via a JavaScript interface. To enhance the accessibility and usability of web-based molecular visualization, we introduce MolViewSpec (molstar.org/mol-view-spec), a standardized approach for defining molecular visualizations that decouples the definition of complex molecular scenes from their rendering. Scene definition can include references to commonly used structural, volumetric, and annotation data formats together with a description of how the data should be visualized and paired with optional annotations specifying colors, labels, measurements, and custom 3D geometries. Developed as an open standard, this solution paves the way for broader interoperability and support across different programming languages and molecular viewers, enabling more streamlined, standardized, and reproducible visual molecular analyses. MolViewSpec is freely available as a Mol* extension and a standalone Python package.

Midlik, Adam [European Bioinformatics Institute (U↗

Innovative Features of NASA's Celestial Mapping System to Support Exploration in the Lunar South Pole

Introduction: NASA's Celestial Mapping System (CMS) is developed to address the need for 3D tools for planetary science investigations, mission planning, in-situ operations, in a 3D-first design constructed around a unified view of a planetary globe. At present CMS provides many critical functionalities that include 1) Equipment planning and optimized placement on Lunar surface 2) Line of sight (visibility ) analysis 3) Powerful measurement tools based on 3D terrain with realistic 3D models to represent rovers, astronauts and equipment 4) Visualization of de-rived mapping products (e.g. resource maps), and 5) Data engine for hosting new observations that are not available in other contemporary lunar data tools. CMS is built on the foundation of powerful NASA WorldWind globe engines. In near future, users will be able to simultaneously deploy CMS onto multiple hardware configurations and platforms such as Windows, Linux, iOS and Android. The users will also have the flexibility to update to the latest imagery and terrain datasets as they are being acquired (in real time) before and/or during the exploration mission. CMS is also capable of consumption and analysis of data from locally hosted and external sources. It supports Open Geospatial Consorti-um (OGC) data and file standards, with current integrations of datasets from the Astrogeology Science Center of USGS which include global and local data acquired from NASA (LRO, Clementine, Lunar Orbiter) and JAXA (SELENE/Kaguya) with the capability of integrating more datasets. With development experience in both the end-user application and planetary engine side, CMS is also able to adapt to newer Lunar cartography standards as they develop and become recognized by international geospatial panels. Overcoming Polar Distortions: 3D geospatial applications traditionally suffer from significant distortion of imagery at the poles due to following reasons – 1) distortions in the source imagery 2) Incompatible tessellation algorithm on the poles 3) map projections. In the lunar context, with the focus on the South pole, this is not acceptable. The CMS team is researching ways to address polar distortion of imagery with new tessellation algorithms and by reprojecting the data using projections that are more accurate in polar scenarios. Figure1 shows the potential error introduced by different tessellation methods, represented by the red and green circles for Shoemaker crater. There is ~2 Km difference in the placement of the crater. Line of Sight Analysis and Traverse Planning: We have developed a built-in line of sight analysis (LOS) tool in CMS that analyzes the terrain profile and obstructions and provides the visibility of a given terrain for a remote observer. Figure 2 shows the viewshed analysis on the PSR in Nobile region. The PSR was created with help of HORUS generated images. The yellow pin shows the observer location outside the PSR. The yellow area shows the visible part of PSR. The obstructed area with no visibility for the observer is shown in red. This analysis was ex-tended further to set different heights for various observers and then perform the viewshed analysis. Combining the different visibility profiles can help designing improved traverses within the crater.

Geospatial Mapping↗

Innovative Features of NASA's Celestial Mapping System to Support Exploration in the Lunar South Pole

Introduction: NASA's Celestial Mapping System (CMS) is developed to address the need for 3D tools for planetary science investigations, mission planning, in-situ operations, in a 3D-first design constructed around a unified view of a planetary globe. At present CMS provides many critical functionalities that include 1) Equipment planning and optimized placement on Lunar surface 2) Line of sight (visibility ) analysis 3) Powerful measurement tools based on 3D terrain with realistic 3D models to represent rovers, astronauts and equipment 4) Visualization of de-rived mapping products (e.g. resource maps), and 5) Data engine for hosting new observations that are not available in other contemporary lunar data tools. CMS is built on the foundation of powerful NASA WorldWind globe engines. In near future, users will be able to simultaneously deploy CMS onto multiple hardware configurations and platforms such as Windows, Linux, iOS and Android. The users will also have the flexibility to update to the latest imagery and terrain datasets as they are being acquired (in real time) before and/or during the exploration mission. CMS is also capable of consumption and analysis of data from locally hosted and external sources. It supports Open Geospatial Consorti-um (OGC) data and file standards, with current integrations of datasets from the Astrogeology Science Center of USGS which include global and local data acquired from NASA (LRO, Clementine, Lunar Orbiter) and JAXA (SELENE/Kaguya) with the capability of integrating more datasets. With development experience in both the end-user application and planetary engine side, CMS is also able to adapt to newer Lunar cartography standards as they develop and become recognized by international geospatial panels. Overcoming Polar Distortions: 3D geospatial applications traditionally suffer from significant distortion of imagery at the poles due to following reasons – 1) distortions in the source imagery 2) Incompatible tessellation algorithm on the poles 3) map projections. In the lunar context, with the focus on the South pole, this is not acceptable. The CMS team is researching ways to address polar distortion of imagery with new tessellation algorithms and by reprojecting the data using projections that are more accurate in polar scenarios. Figure1 shows the potential error introduced by different tessellation methods, represented by the red and green circles for Shoemaker crater. There is ~2 Km difference in the placement of the crater. Line of Sight Analysis and Traverse Planning: We have developed a built-in line of sight analysis (LOS) tool in CMS that analyzes the terrain profile and obstructions and provides the visibility of a given terrain for a remote observer. Figure 2 shows the viewshed analysis on the PSR in Nobile region. The PSR was created with help of HORUS generated images. The yellow pin shows the observer location outside the PSR. The yellow area shows the visible part of PSR. The obstructed area with no visibility for the observer is shown in red. This analysis was ex-tended further to set different heights for various observers and then perform the viewshed analysis. Combining the different visibility profiles can help designing improved traverses within the crater.

Geospatial Mapping↗

Effect of helical micro-fins on two-phase flow behavior of R410A evaporating in horizontal round tubes obtained through visualization

This paper presents a new approach in visualization of the evaporation mechanism and the two phase flow. The visualization test section is a transparent micro-fin tube made by 3D printing. The 3D printing technology helps reproduce the real geometry in commercial metal micro-fin tubes. Even though the wall material is different from the real metal, this new method provides a more complete understanding of the mechanisms of flow boiling and the heat transfer enhancement due to micro-fin geometry. To investigate the effect of micro-fin geometries on two-phase flow behavior, R410A flow boiling experiments are conducted at 1°C saturation temperature and visualized through a clear smooth tube and micro-fin tubes of 0°, 10° and 18° helix angles. The results showed that the annular flow pattern in the helical micro-fin tube occurred at a lower vapor quality than the smooth and axial micro-fin tubes. Helix angle affects the transition boundary of stratified wavy flow to wavy annular flow, which shifts downward (to lower mass flux and vapor quality conditions) as the helix angle increases. Other transitions are not significantly affected by the helix angle. Helical micro-fin tubes with different groove directions were made to understand the flow behavior on the upward side and downward side of the tube.

3D printing↗

Discerning Cell Surface Defects with 3D Optical Profilometry

This investigation seeks to establish better criteria that can be used for qualitative visual screening of cylindrical battery cells through exploration of various defects across multiple cylindrical Lithium-Ion battery cells. This investigation focuses on INR18650s and INR21700s cells from Molicel, LG, and Samsung. The principal instrument used is a high-definition 3D optical profilometer with measurement accuracy less than 0.5 microns. Through this effort, a catalog was built discerning minor surface imperfections from significant flaws. The catalog generated covers a comparison of axial and radial scratches, less than 5 microns, greater than 5 microns and greater than 15 microns, as well as the difference between surface discoloration, early-stage pitting, and late stages of corrosion. An exploration is made into cell button defects and crimp shoulder defects. When ultra-high-power optical magnification and three-dimension topological tools are not immediately available, this catalog will help determine if an individual cell is usable, worth further investigation, or failing. The purpose of this catalog is to be a field guide used for quick reference of a potential issue, with the goal of increasing screening throughput while reducing the need for costly examination. Trade names and trademarks are used in this abstract for identification only. Their usage does not constitute an official endorsement, either expressed or implied, by the National Aeronautics and Space Administration.

battery↗

Discerning Cell Surface Defects with 3D Optical Profilometry

This investigation seeks to establish better criteria that can be used for qualitative visual screening of cylindrical battery cells through exploration of various defects across multiple cylindrical Lithium-Ion battery cells. This investigation focuses on INR18650s and INR21700s cells from Molicel, LG, and Samsung. The principal instrument used is a high-definition 3D optical profilometer with measurement accuracy less than 0.5 microns. Through this effort, a catalog was built discerning minor surface imperfections from significant flaws. The catalog generated covers a comparison of axial and radial scratches, less than 5 microns, greater than 5 microns and greater than 15 microns, as well as the difference between surface discoloration, early-stage pitting, and late stages of corrosion. An exploration is made into cell button defects and crimp shoulder defects. When ultra-high-power optical magnification and three-dimension topological tools are not immediately available, this catalog will help determine if an individual cell is usable, worth further investigation, or failing. The purpose of this catalog is to be a field guide used for quick reference of a potential issue, with the goal of increasing screening throughput while reducing the need for costly examination. Trade names and trademarks are used in this abstract for identification only. Their usage does not constitute an official endorsement, either expressed or implied, by the National Aeronautics and Space Administration.

battery↗