Water-Film Cooling of an 80 deg Total-Angle Cone at a Mach Number of 2 for Airstream Total Temperatures up to 3,000 deg R
Film-cooling tests, with water as the coolant, were made on an 80 deg total-angle cone in a Mach number 2 free jet at sea-level pressure. The tests were made at free-stream total temperatures from 1,500 deg R to 3,000 deg R and at free-stream Reynolds numbers per foot from 8 x 10(exp 6) to 3 x 10(exp 6). The tests showed that the downstream end of the model became very hot if the coolant rate was too small to cover the complete model with a water film. This water film was fairly symmetrical when the model was at zero angle of attack but was very asymmetrical when the model was at an angle of attack of 5 deg. A comparison with results of a previous transpiration-cooling test showed that, with water as the coolant, transpiration cooling was at least 2.5 times as efficient as the film cooling of the present tests.