Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

First-Principles Approach for Assessing Cold Electron Injection Efficiency of Dye-Sensitized Solar Cell: Elucidation of Mechanism of Charge Injection and Recombination

The adequacy of the inclusion of spacer units in the metal-free D-π–A organic dyes pertaining to the augmentation of dye-sensitized solar cell (DSSC) efficiency has been examined through the excited-state simulations of the charge injection and recombination processes at the dye–semiconductor interface. Within the framework of the time-dependent density functional theory, the proposed computational studies focus on the precise evaluation of pivotal factors controlling the rates of photoinduced charge-transfer and energy-transfer processes, including electronic coupling, reorganization energy, and threshold energy barrier in the semiclassical Marcus formalism. The estimation of the fluorescent state appears to be the crucial step while explaining the ultrafast electron injection process and the charge recombination at the Marcus inverted region, as revealed by the obtained results. The retardation of charge recombination is facilitated by the insertion of a thiophene moiety between the π-bridge and the acceptor units. The estimated cold electron injection efficiencies deploying the Onsager–Braun theory, that rely on the computations of cold electron injection lifetime and cold electron lifetime, show a linear correlation with the experimental photovoltaic parameters of the DSSC comprising short-circuit current density, open-circuit voltage, and power conversion efficiency. The outcomes of the present investigation establish a basis for unraveling the mechanism of intricate dynamical processes upon photoexcitation of the sensitizers, as well as devising plausible routes for functional DSSC materials.

14 SOLAR ENERGY↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

High voltage transmission microscopy of Surveyor 3 camera shrouds

The internal structure of painted and unpainted aluminum alloy sheet samples from the TV camera shrouds were examined by high-voltage transmission electron microscopy. No clear-cut evidence of radiation damage effects was observed. Noticeable differences in microstructures between the upper visor and the sides and bottom of the lower shroud suggest different thermal histories, and the maximum temperatures due to solar heating are estimated to be between 164 and 319 C. Some correlation between microstructures and maximum estimated temperature is noted. It is felt that the apparent temperature rise due to solar heating will not affect the structural integrity of spacecraft components except possibly for very long periods of exposure. However, substantial thermal diffusion could affect interpretation of solar wind rare gas studies.

Fisher, R. M.↗

Multi-Parameter Nonlinear Gain Correction of X-Ray Transition Edge Sensors for the X-Ray Integral Field Unit

With its array of 3840 Transition Edge Sensors (TESs), the Athena X-ray Integral Field Unit (X-IFU) will provide spatially resolved high-resolution spectroscopy (2.5 eV up to 7 keV) from 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. Slight changes in the TES operating environment can cause significant variations in its energy response function, which may result in systematic errors in the absolute energy scale. We plan to monitor such changes at pixel level via onboard X-ray calibration sources and correct the energy scale accordingly using a linear or quadratic interpolation of gain curves obtained during ground calibration. However, this may not be sufficient to meet the 0.4 eV accuracy required for the XIFU. In this contribution, we introduce a newtwo-parameter gain correction technique, based on both the pulse-height estimate of a fiducial line and the baseline value of the pixels. Using gain functions that simulate ground calibration data, we show that this technique can accurately correct deviations in detector gain due to changes in TES operating conditions such as heat sink temperature, bias voltage, thermal radiation loading and linear amplifier gain. We also address potential optimisations of the onboard calibration source and compare the performance of this new technique with those previously used.

Cucchetti, E.↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data: Preprint

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data

Many distribution network monitoring and control applications - including state estimation, Volt/VAr optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder-head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure (AMI)↗

Performance Evaluation and Loss Modeling of WBG Devices based on a Novel Double-Pulse Test Method for Current Source Inverter

Careful measurements of the power device characteristics are necessary to accurately estimate a power converter's losses and efficiency. The conventional double-pulse test (DPT) circuit is a well-known method to implement this laboratory characterization of power devices and power modules. However, the switching characteristics of a power device depend on the power electronics circuit in which it is connected as well as the power circuit's physical layout, in addition to the device's internal structure. Hence, the conventional DPT circuit configuration, which is tailored for a standard voltage-source inverter (VSI), is not well-suited for a current-source inverter (CSI). This paper demonstrates a previously-proposed CSI-based DPT measurement technique that is appropriate for normal CSI operation. The characteristics of SiC MOSFETs and series-connected SiC Schottky diodes used in a CSI are measured using this improved technique while taking temperature effects into account to yield more accurate loss predictions. The CSI losses, including the switching and conduction losses of SiC MOSFETs and SiC Schottky diodes, have been modeled using this approach. The total CSI losses and efficiency have been estimated based on the CSI DPT results and loss models.

42 ENGINEERING↗

Spatial Impacts of Electric Vehicle Charging on Power Grid Stability: A Downtown Atlanta Case Study

The rapid increase in electric vehicle (EV) charging demand poses a potential risk to power grid stability, particularly as the spatial distribution of this demand remains underexplored. Existing research often focuses on technical optimization models while overlooking the geographic and human dynamics that affect energy consumption. This study addresses this gap by incorporating mobility data to estimate both building energy use and EV charging demand while also considering geographic factors for a better understanding of grid load. Using agent-based simulations and the Open-Source Distribution System Simulator, the study evaluates the effect of various EV penetration scenarios on grid voltage and unbalance. The results show that, although voltage remains within acceptable limits at lower EV penetration rates, significant voltage drop and unbalance occur as EV penetration exceeds 40%, particularly in residential areas with high charging demand. This study offers a framework for integrating spatial analysis and mobility data in power network simulations, providing insights for future EV infrastructure planning.

Pan, Melrose [ORNL] (ORCID:000000031627448X)↗

Multi-Fidelity Stochastic Economic Dispatch for Operating Low Carbon Power Grids

Grid operators can address the inherently stochastic nature of renewables by solving a two-stage stochastic programming model that minimizes the cost of dispatch decisions while accounting for the complex grid dynamics. It is common to use a sample average approximation to estimate the expectation of the second stage costs in this model. However, the large sample count needed for numerical accuracy makes effective modeling large-scale electric grids computationally intractable. We introduce a control variate multi-fidelity estimator for the second-stage recourse that enables high quality dispatch decisions in real-time with a reduced computational burden. We obtain a hierarchy of model fidelities by linearizing the AC power flow system representation to DC power flow, and by relaxing transmission and voltage network constraints. We evaluate the performance of our proposed method on a synthetic grid with 73 buses against a deterministic baseline with persistence forecast and a high-fidelity reference. Our analysis shows a computational speed-up of 7.62x with a minimal loss in accuracy. The multi-fidelity method is well suited to fidelity combinations that use a simplified network topology in their lower fidelity model and is an attractive option for applications where accurate grid modeling needed on a limited computational budget.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Duration test of an annular colloid thruster.

An annular colloid thruster was continuously operated for 1023 hours. Performance was stable with no sparking and negligible drain currents observed. An average thrust of 25.1 micropounds and an average specific impulse of 1160 seconds were obtained at an accelerating voltage of 15 k he thruster exhaust beam was continuously neutralized using electrons and electrostatic vectoring was demonstrated periodically. The only clear trend with time was an increase in specific impulse during the last third of the test period. From these results the thruster lifetime was estimated to be over an order of magnitude greater than the test duration.

Perel, J.↗

A computational algorithm for crack determination: The multiple crack case

An algorithm for recovering a collection of linear cracks in a homogeneous electrical conductor from boundary measurements of voltages induced by specified current fluxes is developed. The technique is a variation of Newton's method and is based on taking weighted averages of the boundary data. The method also adaptively changes the applied current flux at each iteration to maintain maximum sensitivity to the estimated locations of the cracks.

Bryan, Kurt↗

The PIT MkV pulsed inductive thruster

The pulsed inductive thruster (PIT) is an electrodeless, magnetic rocket engine that can operate with any gaseous propellant. A puff of gas injected against the face of a flat (spiral) coil is ionized and ejected by the magnetic field of a fast-rising current pulse from a capacitor bank discharge. Single shot operation on an impulse balance has provided efficiency and I(sub sp) data that characterize operation at any power level (pulse rate). The 1-m diameter MkV thruster concept offers low estimated engine mass at low powers, together with power capability up to more than 1 MW for the 1-m diameter design. A 20 kW design estimate indicates specific mass comparable to Ion Engine specific mass for 10,000 hour operation, while a 100,000 hour design would have a specific mass 1/3 that of the Ion Engine. Performance data are reported for ammonia and hydrazine. With ammonia, at 32 KV coil voltage, efficiency is a little more than 50 percent from 4000 to more than 8000 seconds I(sub sp). Comparison with data at 24 and 28 kV indicates that a wider I(sub sp) range could be achieved at higher coil voltages, if required for deep space missions.

Dailey, C. Lee↗

Adapting confocal Raman microscopy for in situ studies of redox transformations at electrode-electrolyte interfaces

Confocal Raman microscopy was applied to quantify redox species present within the diffusion layer adjacent to an electrode surface under potentiostatic control. A glass microscope coverslip with a thin indium tin oxide (ITO) coating served as both the working electrode and optical window for a microscope-stage mountable spectroelectrochemical cell. A high numerical aperture objective mounted in an inverted microscope frame just below the stage brought excitation radiation through the coverslip window and to a tight focus a few micrometers above the ITO film surface. Species diffusing into the confocal probe volume defined by the excitation beam focus and the collected light region were detected, identified and quantified based on their Raman scattering frequencies and intensities. Here, in measurements that interrogated the interconversion of ferrocyanide and ferricyanide ions as a function of applied voltage, least-squares regression analysis of spectral datasets predicted the formal potential and relative surface concentrations of the ions in good agreement with the expected Nernstian response. Preliminary studies of methyl viologen reduction at an ITO film/Nafion membrane interface were conducted and show the possibility for estimation of mass transport coefficients of redox species within ionic polymer materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrostatic gate-controlled quantum interference in a high-mobility two-dimensional electron gas at the (La 0.3 ⁢Sr 0.7 )(Al 0.65 ⁢Ta 0.35 )O 3 /SrTiO 3 interface

Here, we report quantum oscillations in magnetoresistance that are periodic in magnetic field (𝐵), observed at the interface between (La 0.3 ⁢Sr 0.7 )(Al 0.65 ⁢Ta 0.35 )O 3 and SrTiO 3 . Unlike Shubnikov–de Haas oscillations, which appear at magnetic fields > 7 T and diminish quickly as the temperature rises, these 𝐵-periodic oscillations emerge at low fields and persist up to 10 K. Their amplitude decays exponentially with both temperature and field, specifying dephasing of quantum interference. Increasing the carrier density through electrostatic gating results in a systematic reduction in both the amplitude and frequency of the oscillations, with complete suppression beyond a certain gate voltage. We attribute these oscillations to the Altshuler-Aronov-Spivak effect, likely arising from naturally formed closed-loop paths due to the interconnected quasi-one-dimensional conduction channels along SrTiO 3 domain walls. The relatively long phase coherence length (≃ 1.8 µ⁢m at 0.1 K), estimated from the oscillation amplitude, highlights the potential of complex oxide interfaces as a promising platform for exploring quantum interference effects and advancing device concepts in quantum technologies, such as mesoscopic interferometers and quantum sensors.

36 MATERIALS SCIENCE↗

Estimation, Minimization, and Validation of Commutation Loop Inductance for a 135-kW SiC EV Traction Inverter

With growing interests in low inductance SiC based power module packaging, it is vital to focus on system level design aspects to facilitate easy integration of the modules and reap system level benefits. To effectively utilize the low inductance modules, busbar and interconnects should also be designed with low stray inductances. A wholistic investigation of the flux path and flux cancellations in the module-busbar assembly which as differentially coupled series inductors is thus mandatory for a system level design. This work presents a busbar design which can be adopted to effectively integrate the CREE’s low inductance 1.2 kV/1.7 kV SiC power modules. The paper also proposes a novel measurement technique to measure the inductance of the modulebusbar assembly as a whole rather than deducing it from individual components. The inductance of the overall commutation loop of the inverter which encompasses the SiC power module, interconnects and PCB busbar have been estimated using finite element analysis (FEA). Furthermore, insights gained from FEA provided the guidelines to decide on the placement of the decoupling capacitors in the busbar to minimize the overall commutation loop inductance from 12.8 nH to 7.4 nH which resulted in significant reduction in the device voltage overshoot. The simulation results have been validated through measurements using an impedance analyzer with less than 5% difference between extracted loop inductance from FEA and measurements. The bus bar design study and the measurement technique discussed in this paper, can be easily extended to other power module packages. Finally, the 135 kW inverter has been compared to a similar highpower inverter utilizing a laminated busbar to highlight the performance of the former.

42 ENGINEERING↗

Maximum theoretical angular accuracy of planar and linear arrays of sensors

The maximum theoretical accuracy in the angular location of a radiating object that can be obtained by using a planar or linear array is studied. The elements are assumed to have identical radiation patterns and the complex voltages observed at their ports are assumed to be subject to phase measurement errors, having normal probability density. An optimum scheme for the statistical extraction of the parameters defining the direction is established noting that the presence of thermal noise does not affect the structure of the estimator. Comparisons with the conventional multiple interferometric techniques are made.

Borgiotti, G. V.↗

Switched low-dropout voltage regulator

High-resolution switched digital regulators are disclosed having fast cross corner and variable temperature response, with constrained ripple. The strength of the power transistors utilized by the regulator are adjusted to control the current delivered to the load. The regulators utilize a slow control loop in parallel with a primary fast switching loop. The slow loop uses the switching signal of the primary loop to estimate the load current and set the power transistor size accordingly.

Kudva, Sudhir Shrikantha↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗