Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “versatile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A versatile apparatus for on-line emission channeling experiments

The concept and functionality of an apparatus dedicated to emission channeling experiments using short-lived isotopes on-line at ISOLDE/CERN is described. The setup is assembled in two functional blocks – (a) base stand including beam collimation, implantation and measurement chamber, cryogenic extension, and vacuum control system and (b) Panmure goniometer extension including maneuvering cradle and sample heating furnace. This setup allows for in situ implantation and sample analysis in the as-implanted state and upon cooling down to 50 K and during annealing up to 1200 K. The functionality of the setup will be illustrated with the example of establishing the lattice location of {sup 56}Mn probes implanted into GaAs.

43 PARTICLE ACCELERATORS↗

A compact, versatile low-energy electron beam ion source

A new compact Electron Beam Ion Source, the Dresden EBIT-LE, is introduced as an ion source working at low electron beam energies. The EBIT-LE operates at an electron energy ranging from 100 eV to some keV and can easily be modified to an EBIT also working at higher electron beam energies of up to 15 keV. We show that, depending on the electron beam energy, electron beam currents from a few mA in the low-energy regime up to about 40 mA in the high-energy regime are possible. Technical solutions as well as first experimental results of the EBIT-LE are presented. In ion extraction experiments, a stable production of low and intermediate charged ions at electron beam energies below 2 keV is demonstrated. Furthermore, X-ray spectroscopy measurements confirm the possibility of using the machine as a source of X-rays from ions excited at low electron energies.

43 PARTICLE ACCELERATORS↗

Versatile radar measurement of the electron loss rate in air

We present an experimental method that makes possible in-situ measurements of the electron loss rate in arbitrary gas mixtures. A weakly ionized plasma is induced via resonant multiphoton ionization of trace amounts of nitric oxide seeded into the gas, and homodyne microwave scattering detection is used to study the dynamics of the electron loss mechanisms. Using this approach, the attachment rate for electrons to molecular oxygen in room temperature, atmospheric pressure air is determined. The measured 0.76 × 10{sup 8} s{sup −1} attachment rate is in very good agreement with predictions based on literature data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A versatile optical junction using photonic band-gap guidance and self collimation

We show that it is possible to design two photonic crystal (PC) structures such that an optical beam of desired wavelength gets guided within the line defect of the first structure (photonic band gap guidance) and the same beam gets guided in the second structure by self-collimation. Using two dimensional simulation of a design made of the combination of these two structures, we propose an optical junction that allows for crossing of two optical signals of same wavelength and same polarization with very low crosstalk. Moreover, the junction can be operated at number of frequencies in a wide range. Crossing of multiple beams with very low cross talk is also possible. The proposed junction should be important in future integrated photonic circuits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Beam-deposited platinum as versatile catalyst for bottom-up silicon nanowire synthesis

The controlled localized bottom-up synthesis of silicon nanowires on arbitrarily shaped surfaces is still a persisting challenge for functional device assembly. In order to address this issue, electron beam and focused ion beam-assisted catalyst deposition have been investigated with respect to platinum expected to form a PtSi alloy catalyst for a subsequent bottom-up nanowire synthesis. The effective implementation of pure platinum nanoparticles or thin films for silicon nanowire growth has been demonstrated recently. Beam-deposited platinum contains significant quantities of amorphous carbon due to the organic precursor and gallium ions for a focused ion beam-based deposition process. Nevertheless, silicon nanowires could be grown on various substrates regardless of the platinum purity. Additionally, p-type doping could be realized with diborane whereas n-type doping suppressed a nanowire growth. The rational utilization of this beam-assisted approach enables us to control the localized synthesis of single silicon nanowires at planar surfaces but succeeded also in single nanowire growth at the three-dimensional apex of an atomic force microscopy tip. Therefore, this catalyst deposition method appears to be a unique extension of current technologies to assemble complex nanowire-based devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A versatile LabVIEW and field-programmable gate array-based scanning probe microscope for in operando electronic device characterization

Understanding the complex properties of electronic and spintronic devices at the micro- and nano-scale is a topic of intense current interest as it becomes increasingly important for scientific progress and technological applications. In operando characterization of such devices by scanning probe techniques is particularly well-suited for the microscopic study of these properties. We have developed a scanning probe microscope (SPM) which is capable of both standard force imaging (atomic, magnetic, electrostatic) and simultaneous electrical transport measurements. We utilize flexible and inexpensive FPGA (field-programmable gate array) hardware and a custom software framework developed in National Instrument's LabVIEW environment to perform the various aspects of microscope operation and device measurement. The FPGA-based approach enables sensitive, real-time cantilever frequency-shift detection. Using this system, we demonstrate electrostatic force microscopy of an electrically biased graphene field-effect transistor device. The combination of SPM and electrical transport also enables imaging of the transport response to a localized perturbation provided by the scanned cantilever tip. Facilitated by the broad presence of LabVIEW in the experimental sciences and the openness of our software solution, our system permits a wide variety of combined scanning and transport measurements by providing standardized interfaces and flexible access to all aspects of a measurement (input and output signals, and processed data). Our system also enables precise control of timing (synchronization of scanning and transport operations) and implementation of sophisticated feedback protocols, and thus should be broadly interesting and useful to practitioners in the field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molybdenum oxide MoO{sub x}: A versatile hole contact for silicon solar cells

This letter examines the application of transparent MoO{sub x} (x < 3) films deposited by thermal evaporation directly onto crystalline silicon (c-Si) to create hole-conducting contacts for silicon solar cells. The carrier-selectivity of MoO{sub x} based contacts on both n- and p-type surfaces is evaluated via simultaneous consideration of the contact recombination parameter J{sub 0c} and the contact resistivity ρ{sub c}. Contacts made to p-type wafers and p{sup +} diffused regions achieve optimum ρ{sub c} values of 1 and 0.2 mΩ·cm{sup 2}, respectively, and both result in a J{sub 0c} of ∼200 fA/cm{sup 2}. These values suggest that significant gains can be made over conventional hole contacts to p-type material. Similar MoO{sub x} contacts made to n-type silicon result in higher J{sub 0c} and ρ{sub c} with optimum values of ∼300 fA/cm{sup 2} and 30 mΩ·cm{sup 2} but still offer significant advantages over conventional approaches in terms of contact passivation, optical properties, and device fabrication.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A versatile apparatus for the fine-tuned synthesis of cluster-based materials

In this paper, a custom-designed experimental setup for the fine-tuned synthesis of various cluster–based materials is presented. Providing custom-designed deposition stages and special sample holders it offers a high degree of control over the sample characteristics such as the cluster size, cluster amounts, and sample homogeneity in combination with high sample purity. The system is capable of producing thin films of pure clusters and various cluster-matrix combinations with cluster sizes ranging from single atoms up to aggregates of several thousand atoms. Two custom-designed deposition stages are available, one utilizes the full cluster beam, yielding micrograms of pure clusters within a few hours and the second one uses mass-separated clusters (mass-resolution between 2% and 10%), yielding nanograms of pure clusters in the same timescale. Furthermore, at the second deposition stage, a variety of matrix materials can be co-deposited at a controlled sample temperature between 153 K and 673 K. In order to prove the capabilities of the apparatus, a series of experiments with Fe clusters embedded in Ag matrices with different volume fractions of clusters were carried out. Energy dispersive X-ray spectroscopy measurements revealed that the amount of deposited clusters as well as the sample homogeneity can be controlled with an outstanding accuracy of 10%. Additional measurements of the magnetic properties indicated the presence of separated clusters for volume fractions of clusters around 2 volume percent (vol. %), while above this concentration (10 vol. %) a partial aggregation of the clusters was observed. It was also shown that the resulting thin films are nearly oxygen free, which ascertains that oxygen sensitive materials can be safely handled in this newly developed apparatus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile atomic force microscopy setup combined with micro-focused X-ray beam

Micro-focused X-ray beams produced by third generation synchrotron sources offer new perspective of studying strains and processes at nanoscale. Atomic force microscope setup combined with a micro-focused synchrotron beam allows precise positioning and nanomanipulation of nanostructures under illumination. In this paper, we report on integration of a portable commercial atomic force microscope setup into a hard X-ray synchrotron beamline. Details of design, sample alignment procedure, and performance of the setup are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A versatile rotary-stage high frequency probe station for studying magnetic films and devices

We present a rotary-stage microwave probe station suitable for magnetic films and spintronic devices. Two stages, one for field rotation from parallel to perpendicular to the sample plane (out-of-plane) and the other intended for field rotation within the sample plane (in-plane) have been designed. The sample probes and micro-positioners are rotated simultaneously with the stages, which allows the field orientation to cover θ from 0{sup ∘} to 90{sup ∘} and φ from 0{sup ∘} to 360{sup ∘}. θ and φ being the angle between the direction of current flow and field in a out-of-plane and an in-plane rotation, respectively. The operation frequency is up to 40 GHz and the magnetic field up to 1 T. The sample holder vision system and probe assembly are compactly designed for the probes to land on a wafer with diameter up to 3 cm. Using homemade multi-pin probes and commercially available high frequency probes, several applications including 4-probe DC measurements, the determination of domain wall velocity, and spin transfer torque ferromagnetic resonance are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A versatile mass spectrometer chamber for molecular beam and temperature programmed desorption experiments

A dual purpose mass spectrometer chamber capable of performing molecular beam scattering (MBS) and temperature programmed desorption (TPD) is detailed. Two simple features of this design allow it to perform these techniques. First, the diameter of entrance aperture to the mass spectrometer can be varied to maximize signal for TPD or to maximize angular resolution for MBS. Second, the mass spectrometer chamber can be radially translated so that it can be positioned close to the sample to maximize signal or far from the sample to maximize angular resolution. The performance of this system is described and compares well with systems designed for only one of these techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photonic nanojets as a versatile optical tool for wave super-localization

The dimensional parameters and intensity of localized light structures (area “photonic nanojet”—PNJ) formed in the near field scattering of the optical wave by dielectric micron particles are studied. The difference between the PNJ characteristics of homogeneous quartz microparticles of different spatial shape and orientation are shown.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient and versatile graphene-based multilayers for EM field absorption

We thoroughly investigate the possibility to absorb most (i.e., up to more than 90%) of the incident electro-magnetic radiations in thin multilayered PMMA/graphene structures, thus proposing the technical realization of a device with an operational frequency range in the millimeter-wave domain, i.e., 30 GHz–300 GHz. Our simulations demonstrate the concrete possibility to enhance the field absorption by means of a selective removal and proper micro-pattering within the graphene material, enabling a complete and efficient control of the graphene sheet conductance. This method is applied to design and engineer a class of devices, endowed with a wideband operation capability, showing almost no fluctuations throughout the whole range of mm-wave frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wisconsin In Situ Penning (WISP) gauge: A versatile neutral pressure gauge to measure partial pressures in strong magnetic fields

A new type of in-vessel Penning gauge, the Wisconsin In Situ Penning (WISP) gauge, has been developed and successfully operated in the Wendelstein 7-X (W7-X) island divertor baffle and vacuum vessel. The capacity of the quantitative measurements of the neutral reservoir for light impurities, in particular, helium, is important for tokamaks as well as stellarator divertors in order to avoid fuel dilution and radiative energy loss. Penning gauges assisted by spectroscopy are a powerful tool to obtain the total neutral pressure as well as fractional neutral pressures of specific impurities. The WISP gauge is a miniaturized Penning gauge arrangement, which exploits the ambient magnetic field of magnetic confinement fusion experiments to establish the Penning discharge. Then, in situ spectroscopy is conducted to separate the fractional neutral pressures of hydrogen, helium, and possibly also other impurities. The WISP probe head was qualified using the magnetic field of the Magnetized Dusty Plasma Experiment at Auburn University between 0.25 T and 3.5 T [E. Thomas et al ., J. Plasma Phys. 81, 345810206 (2015)]. The in-depth quantitative evaluation for hydrogen and helium will be shown as well as an exploration of nitrogen, argon, and neon. A power law scaling between current I and pressure p, I = f (Gas,V) p n⁽Gas, B⁾ , was shown. The factor f is gas and anode potential dependent, while n is gas and magnetic field strength dependent. Pressure measurements from 0.1 mbar and down to 1 × 10 -5 mbar were achieved, demonstrating a reliable operating range for relevant pressure levels in the divertor and main vessel regions in current and future fusion devices, with a time resolution of up to 1 kHz. The lowest achievable pressure measurement increases with an increase in B and can be shifted with the anode potential V . At W7-X, the WISP probe head was mounted on an immersion tube setup that passes through the cryostat and places the probe head close to the plasma. Two probe heads were positioned in different divertor pump gaps, top and bottom, and one close to the plasma on the midplane in one module. The gauges were in situ calibrated together with the ASDEX pressure gauges [G. Haas and H.-S. Bosch, Vacuum 51, 39 (1998)]. Data were taken during the entire operation phase 1.2b, and measurements were coherent with other neutral gas pressure gauges. For the spectroscopic partial pressure measurements, channels of a spectroscopic detection system based on photo-multipliers, a so-called filterscope [R. J. Colchin et al ., Rev. Sci. Instrum. 74, 2068 (2003)], provided by the Oak Ridge National Lab were used.

47 OTHER INSTRUMENTATION↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

Multi-energy reconstructions, central electron temperature measurements, and early detection of the birth and growth of runaway electrons using a versatile soft x-ray pinhole camera at MST

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 μm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

Delgado-Aparicio, L. F. (ORCID:0000000167394380)↗

Feedback lock-in: A versatile multi-terminal measurement system for electrical transport devices

Here, we present the design and implementation of a measurement system that enables parallel drive and detection of small currents and voltages at numerous electrical contacts to a multi-terminal electrical device. This system, which we term a feedback lock-in, combines digital control-loop feedback with software-defined lock-in measurements to dynamically source currents and measure small, pre-amplified potentials. The effective input impedance of each current/voltage probe can be set via software, permitting any given contact to behave as an open-circuit voltage lead or as a virtually grounded current source/sink. This enables programmatic switching of measurement configurations and permits measurement of currents at multiple drain contacts without the use of current preamplifiers. Our 32-channel implementation relies on commercially available digital input/output boards, home-built voltage preamplifiers, and custom open-source software. With our feedback lock-in, we demonstrate differential measurement sensitivity comparable to a widely used commercially available lock-in amplifier and perform efficient multi-terminal electrical transport measurements on twisted bilayer graphene and SrTiO 3 quantum point contacts. The feedback lock-in also enables a new style of measurement using multiple current probes, which we demonstrate on a ballistic graphene device.

47 OTHER INSTRUMENTATION↗