Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A Summary of Recent Experimental Research on Ion Energy and Charge States of Pulsed Vacuum Arcs

The paper reviews the results of vacuum arc experimental investigations made collaboratively by research groups from Berkeley and Tomsk over the last two years, i.e. since the last ISDEIV in 2006. Vacuum arc plasma of various metals was produced in pulses of a few hundred microseconds duration, and the research focussed on three topics: (i) the energy distribution functions for different ion charge states, (ii) the temporal development of the ion charge state distribution, and (iii) the evolution of the mean directed ion velocities during plasma expansion. A combined quadruple mass-to-charge and energy ana-lyzer (EQP by HIDEN Ltd) and a time-of-flight spectrometer were employed. Cross-checking data by those complimen-tary techniques helped to avoid possible pitfalls in interpre-tation. It was found that the ion energy distribution func-tions in the plasma were independent of the ion charge state, which implies that the energy distribution on a substrate are not equal to due to acceleration in the substrate's sheath. In pulsed arc mode, the individual ion charge states fractions showed changes leading to a decrease of the mean charge state toward a steady-state value. This decrease can be re-duced by lower arc current, higher pulse repetition rate and reduced length of the discharge gap. It was also found that the directed ion velocity slightly decreased as the plasma expanded into vacuum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recovery of phosphonate surface contaminants from glass using a simple vacuum extractor with a solid-phase microextraction fiber

Recovery of chemical contaminants from fixed surfaces for analysis can be challenging particularly if it is not possible to acquire a solid sample. A simple device is described that collects semivolatile organic compounds from fixed surfaces by creating an enclosed volume over the surface, then generating a modest vacuum. A solid-phase microextraction fiber is then inserted into the evacuated volume where it functions to sorb volatilized organic contaminants. The device is based on a syringe modified with a seal that is used to create the vacuum, with a perforable plunger through which the SPME fiber is inserted. The vacuum speeds partitioning of the semivolatile compounds into the gas phase, and reduces the boundary layer around the SPME fiber, which enables a fraction of the volatilized organics to partition into the SPME fiber. After sample collection the SPME fiber is analyzed using conventional gas chromatography/mass spectrometry. The methodology has been used to collect organophosphorus compounds from glass surfaces, to provide a simple test for the functionality of the devices. Thirty minute sampling times (deltaTvac) resulted in fractional recovery efficiencies ranged from 10(-3) to > 10(-1), and in absolute terms collection of low nanograms was demonstrated. Fractional recovery values were correlated to the vapor pressure of the compounds being sampled. Fractional recovery increased with increasing deltaTvac, and displayed a roughly logarithmic profile indicating that an operational equilibrium is being approached. Fractional recovery decreased with increasing time between exposure and sampling, however recordable quantities of the phosphonates could be collected three weeks after exposure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vacuum birefringence in strong magnetic fields: (II) Complex refractive index from the lowest Landau level

We compute the refractive indices of a photon propagating in strong magnetic fields on the basis of the analytic representation of the vacuum polarization tensor obtained in our previous paper. When the external magnetic field is strong enough for the fermion one-loop diagram of the polarization tensor to be approximated by the lowest Landau level, the propagating mode in parallel to the magnetic field is subject to modification: The refractive index deviates from unity and can be very large, and when the photon energy is large enough, the refractive index acquires an imaginary part indicating decay of a photon into a fermion–antifermion pair. We study dependences of the refractive index on the propagating angle and the magnetic-field strength. It is also emphasized that a self-consistent treatment of the equation which defines the refractive index is indispensable for accurate description of the refractive index. This self-consistent treatment physically corresponds to consistently including the effects of back reactions of the distorted Dirac sea in response to the incident photon. -- Highlights: •Vacuum birefringence and photon decay are described by the complex refractive index. •Resummed photon vacuum polarization tensor in the lowest Landau level is used. •Back reactions from the distorted Dirac sea are self-consistently taken into account. •Self-consistent treatment drastically changes structure in photon energy dependence. •Dependences on photon propagation angle and magnetic-field strength are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Response of a uniformly accelerated detector to massless Rarita–Schwinger fields in vacuum

We study the response of a uniformly accelerated detector modeled by a two-level atom nonlinearly coupled to vacuum massless Rarita–Schwinger fields. We first generalize the formalism developed by Dalibard, Dupont-Roc, and Cohen-Tannoudji in the linear coupling case, and we then calculate the mean rate of change of the atomic energy of the accelerated atom. Our result shows that a uniformly accelerated atom in its ground state interacting with vacuum Rarita–Schwinger field fluctuations would spontaneously transition to an excited state and the unique feature in contrast to the case of the atom coupled to the scalar, electromagnetic and Dirac fields is the appearance of terms in the excitation rate which are proportional to the sixth and eighth powers of acceleration. - Highlights: • We study the response of an accelerated detector to Rarita–Schwinger fields. • Detector spontaneously transitions to an excited state in vacuum. • Excitation rate contains terms of the sixth and eighth powers of acceleration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Local quanta, unitary inequivalence, and vacuum entanglement

In this work we develop a formalism for describing localised quanta for a real-valued Klein–Gordon field in a one-dimensional box [0,R]. We quantise the field using non-stationary local modes which, at some arbitrarily chosen initial time, are completely localised within the left or the right side of the box. In this concrete set-up we directly face the problems inherent to a notion of local field excitations, usually thought of as elementary particles. Specifically, by computing the Bogoliubov coefficients relating local and standard (global) quantisations, we show that the local quantisation yields a Fock representation of the Canonical Commutation Relations (CCR) which is unitarily inequivalent to the standard one. In spite of this, we find that the local creators and annihilators remain well defined in the global Fock space F{sup G}, and so do the local number operators associated to the left and right partitions of the box. We end up with a useful mathematical toolbox to analyse and characterise local features of quantum states in F{sup G}. Specifically, an analysis of the global vacuum state |0{sub G}〉∈F{sup G} in terms of local number operators shows, as expected, the existence of entanglement between the left and right regions of the box. The local vacuum |0{sub L}〉∈F{sup L}, on the contrary, has a very different character. It is neither cyclic (with respect to any local algebra of operators) nor separating and displays no entanglement between left and right partitions. Further analysis shows that the global vacuum also exhibits a distribution of local excitations reminiscent, in some respects, of a thermal bath. We discuss how the mathematical tools developed herein may open new ways for the analysis of fundamental problems in local quantum field theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CRYOGENIC AND VACUUM TECHNOLOGICAL ASPECTS OF THE LOW-ENERGY ELECTROSTATIC CRYOGENIC STORAGE RING

The cryogenic and vacuum concepts for the electrostatic Cryogenic ion Storage Ring (CSR), under construction at the Max-Planck-Institut fuer Kernphysik in Heidelberg, is presented. The ring will operate in a broad temperature range from 2 to 300 K and is required to be bakeable up to 600 K. Extremely high vacuum and low temperatures are necessary to achieve long lifetimes of the molecular ions stored in the ring so that the ions will have enough time to cool by radiation to their vibrational and rotational ground states. To test cryogenic and vacuum technological aspects of the CSR, a prototype is being built and will be connected to the commercial cryogenic refrigerator recently installed, including a specialized 2-K connection system. The first results and the status of current work with the prototype are also presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New printed circuit boards magnetic coils in the vacuum vessel of J-TEXT tokamak for position measurement

Four sets of magnetic diagnostic coils, which are printed on machinable ceramic printed circuit boards (PCB), are designed, fabricated, installed, and tested in the Joint Texas Experimental Tokamak (J-TEXT) vacuum vessel for detecting the plasma radial and vertical displacements relative to the geometric center of the vacuum vessel in Ohmic discharges. Each coordinate is determined by a pair of variable cross-section Rogowski and saddle coils, which measure the tangential and normal magnetic fields (relative to the coil surface). These coils are suitable for mass production and offer advantages in vacuum compatibility and temperature tolerance that are important for J-TEXT. Position measurements using PCB coils are compared with those from soft x-ray image system and match the position well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of the beam chamber vacuum system of K = 500 cyclotron at Variable Energy Cyclotron Centre Kolkata

The beam chamber of Variable Energy Cyclotron Centre, Kolkata's K = 500 superconducting cyclotron is pumped by liquid helium cooled cryopanel with liquid nitrogen cooled radiation shield. Performance of the vacuum system was evaluated by cooling the cryopanel assembly with liquid nitrogen and liquid helium. Direct measurement of beam chamber pressure is quite difficult because of space restrictions and the presence of high magnetic field. Pressure gauges were placed away from the beam chamber. The beam chamber pressure was evaluated using a Monte Carlo simulation software for vacuum system and compared with measurements. The details of the vacuum system, measurements, and estimation of pressure of the beam chamber are described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of vacuum pressure with a magneto-optical trap: A pressure-rise method

The lifetime of an atom trap is often limited by the presence of residual background gases in the vacuum chamber. This leads to the lifetime being inversely proportional to the pressure. Here, we use this dependence to estimate the pressure and to obtain pressure rate-of-rise curves, which are commonly used in vacuum science to evaluate the performance of a system. We observe different rates of pressure increase in response to different levels of outgassing in our system. Therefore, we suggest that this is a sensitive method which will find useful applications in cold atom systems, in particular, where the inclusion of a standard vacuum gauge is impractical.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vacuum system of the compact Energy Recovery Linac

The compact Energy Recovery Linac (cERL), a test accelerator to establish important technologies demanded for future ERL-based light sources, was constructed in late 2013 at KEK. The accelerator was successfully commissioned in early 2014, and demonstrated beam circulation with energy recovery. In the cERL vacuum system, low-impedance vacuum components are required to circulate high-intensity, low-emittance and short-bunch electron beams. We therefore developed ultra-high-vacuum (UHV)-compatible flanges that can connect beam tubes seamlessly, and employed retractable beam monitors, namely, a movable Faraday cup and screen monitors. In most parts of the accelerator, pressures below 1×10{sup −7} Pa are required to mitigate beam-gas interactions. Particularly, near the photocathode electron gun and the superconducting (SC) cavities, pressures below 1×10{sup −8} Pa are required. The beam tubes in the sections adjoining the SC cavities were coated with non-evaporable getter (NEG) materials, to reduce gas condensation on the cryo-surfaces. During the accelerator commissioning, stray magnetic fields from the permanent magnets of some cold cathode gauges (CCGs) were identified as a source of the disturbance to the beam orbit. Magnetic shielding was specially designed as a remedy for this issue.

43 PARTICLE ACCELERATORS↗

On the expansion of non-ideal copper plasma into vacuum

The expansion of non-ideal copper plasma into vacuum is analyzed for the conditions typical for explosive electron emission in vacuum arcs. The computational model solves the Euler equations with an equation of state (EoS) for weakly non-ideal plasma, taking into account the ionization energy correction due to electron–ion Coulomb coupling. We have ascertained that the EoS has insignificant influence on the plasma expansion while the plasma properties and composition change drastically. Based on our simulation results, we discuss the validity of the “frozen” state theory often used in the vacuum arc plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parametric Study of the Vacuum Permeator for the Tritium Extraction eXperiment

Tritium breeding is a critical component of any self-sustaining future fusion reactor. The liquid metal eutectic, PbLi, is of particular interest as a tritium breeder material due to its favorable thermophysical and neutronic properties. One of the several remaining challenges facing PbLi breeder blankets is the need to design and validate a highly efficient tritium extraction system. The vacuum permeator is a promising extraction concept that utilizes tritium permeation through a highly permeable metal membrane. The Tritium Extraction eXperiment (TEX) is a forced-convection PbLi loop constructed to investigate tritium extraction from PbLi with vacuum permeators. Accurate thermal-hydraulic and tritium transport models are required to establish appropriate test matrices, predict experiment outcomes, and analyze data. However, the hydrogen transport properties of PbLi and permeator materials have large uncertainties. A database is collected, and a parametric analysis is conducted on the effect of hydrogen transport material properties: diffusivity of H in PbLi and permeator, solubility of H in PbLi and permeator, and permeator surface recombination constant on the expected tritium extraction efficiency for a vacuum permeator installed in TEX. As a result, we observe solubility of H in PbLi and the permeator and the recombination constant of the permeator have the largest effect on the extraction efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-Gaussianity from false vacuum inflation: old curvaton scenario

We calculate the three-point correlation function of the comoving curvature perturbation generated during an inflationary epoch driven by false vacuum energy. We get a novel false vacuum shape bispectrum, which peaks in the equilateral limit. Using this result, we propose a scenario which we call ''old curvaton''. The shape of the resulting bispectrum lies between the local and the false vacuum shapes. In addition we have a large running of the spectral index.

79 ASTRONOMY AND ASTROPHYSICS↗

Massless scalar field vacuum in de Sitter spacetime

As a spacetime with compact spatial sections, de Sitter spacetime does not have a de Sitter-invariant ground state for a minimally-coupled massless scalar field that gives definite expectation values for any observables not invariant under constant shifts of the field. However, if one restricts to observables that are shift invariant, as the action is, then there is a unique vacuum state. Here we calculate the shift-invariant four-point function that is the vacuum expectation value of the product of the difference of the field values at one pair of points and of the difference of the field values at a second pair of points. We show that this vacuum expectation value obeys a cluster-decomposition property of vanishing in the limit that the one pair of points is moved arbitrarily far from the other pair. We also calculate the shift-invariant correlation of the gradient of the scalar field at two different points and show that it also obeys a cluster-decomposition property. Possible relevance to a putative de Sitter-invariant quantum state for gravity is discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

An anisotropic universe due to dimension-changing vacuum decay

In this paper we consider the question of observational signatures of a false vacuum decay event in the early universe followed by a period of inflation; in particular, motivated by the string landscape, we consider decays in which the parent vacuum has a smaller number of large dimensions than the current vacuum, which leads to an anisotropic universe. We go beyond previous studies, and examine the effects on the CMB temperature and polarisation power spectra, due to both scalar and tensor modes, and consider not only late-time effects but also the full cosmological perturbation theory at early times. We find that whilst the scalar mode behaves as one would expect, and the effects of anisotropy at early times are sub-dominant to the late-time effects already studied, for the tensor modes in fact the the early-time effects grow with multipole and can become much larger than one would expect, even dominating over the late-time effects. Thus these effects should be included if one is looking for such a signal in the tensor modes.

79 ASTRONOMY AND ASTROPHYSICS↗

Commissioning of the vacuum system of the KATRIN Main Spectrometer

The KATRIN experiment will probe the neutrino mass by measuring the β-electron energy spectrum near the endpoint of tritium β-decay. We performed an integral energy analysis by an electro-static spectrometer (``Main Spectrometer''), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m 3 , and a complex inner electrode system with about 120 000 individual parts. The strong magnetic field that guides the β-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. Furthermore, a system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300 °C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10 -11 mbar range. We demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Practical quantum random number generator based on measuring the shot noise of vacuum states

The shot noise of vacuum states is a kind of quantum noise and is totally random. In this paper a nondeterministic random number generation scheme based on measuring the shot noise of vacuum states is presented and experimentally demonstrated. We use a homodyne detector to measure the shot noise of vacuum states. Considering that the frequency bandwidth of our detector is limited, we derive the optimal sampling rate so that sampling points have the least correlation with each other. We also choose a method to extract random numbers from sampling values, and prove that the influence of classical noise can be avoided with this method so that the detector does not have to be shot-noise limited. The random numbers generated with this scheme have passed ent and diehard tests.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-color bright squeezed vacuum

In a strongly pumped nondegenerate traveling-wave optical parametric amplifier, we produce a two-color squeezed vacuum with up to millions of photons per pulse. Our approach to registering this macroscopic quantum state is direct detection of a large number of transverse and longitudinal modes, which is achieved by making the detection time and area much larger than the coherence time and area, respectively. Using this approach, we obtain a record value of twin-beam squeezing for direct detection of bright squeezed vacuum. This makes direct detection of macroscopic squeezed vacuum a practical tool for quantum information applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗