Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultrasonic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

High frequency ultrasonic characterization of sintered SiC

High frequency (60 to 160 MHz) ultrasonic nondestructive evaluation was used to characterize variations in density and microstructural constituents of sintered SiC bars. Ultrasonic characterization methods included longitudinal velocity, reflection coefficient, and precise attenuation measurements. The SiC bars were tailored to provide bulk densities ranging from 90 to 98 percent of theoretical, average grain sizes ranging from 3.0 to 12.0 microns, and average pore sizes ranging from 1.5 to 4.0 microns. Velocity correlated with specimen bulk density irrespective of specimen average grain size, average pore size, and average pore orientation. Attenuation coefficient was found to be sensitive to both density and average pore size variations, but was not affected by large differences in average grain size.

Baaklini, George Y.↗

Correlation between ultrasonic velocity and density of ceramic turbine blades

A computer-aided ultrasonic velocity measurement system to detect small density variations in structural ceramic materials has been developed. Longitudinal wave ultrasonic velocity and density of ceramic turbine blades and bars were measured and statistically correlated. Density variations of 1 to 2 percent were reliably detected. Burst speed of ceramic blades was inversely proportional to the grain size of the material.

Khandelwal, P. K.↗

A general-purpose computer program for studying ultrasonic beam patterns generated with acoustic lenses

A 3-D computer model of a piston radiator with lenses for focusing and defocusing is presented. To achieve high-resolution imaging, the frequency of the transmitted and received ultrasound must be as high as 10 MHz. Current ultrasonic transducers produce an extremely narrow beam at these high frequencies and thus are not appropriate for imaging schemes such as synthetic-aperture focus techniques (SAFT). Consequently, a numerical analysis program has been developed to determine field intensity patterns that are radiated from ultrasonic transducers with lenses. Lens shapes are described and the field intensities are numerically predicted and compared with experimental results.

Roberti, Dino↗

Ultrasonic characterization of the nonlinear elastic properties of unidirectional graphite/epoxy composites

The theoretical treatment of linear and nonlinear elasticity in a unidirectionally fiber reinforced composite as well as measurements for a unidirectional graphite/epoxy composite (T300/5208) are presented. Linear elastic properties were measured by both ultrasonic and strain gage measurements. The nonlinear properties were determined by measuring changes in ultrasonic natural phase velocity with a pulsed phase locked loop interferometer as a function of stress and temperature. These measurements provide the basis for further investigations into the relationship between nonlinear elastic properties and other important properties such as strength and fiber-matrix interfacial strength in graphite/epoxy composites.

Prosser, William H.↗

Ultrasonic Detection Of Transply Cracks In Composites

Nondestructive testing technique measures densities of transply cracks and used to monitor propagation of such damage in advanced polymer-matrix composite materials. Acousto-ultrasonic measuring apparatus, used to measure stress-wave factors (SWF's) of undamaged specimens and specimens that contained various numbers of transply cracks. Acousto-ultrasonic technique of value in examining damage to material from one surface only.

Bowles, Kenneth J.↗

An investigation of the temperature dependence of the ultrasonic properties of AS4/lexan and XAS/lexan composites

An investigation of the temperature dependence of the ultrasonic properties of AS4/lexan and XAS/lexan composites is summarized. In particular, a technique for determination of velocity and attenuation as a function of temperature, for both the matrix and composite materials is determined. The separation of contributions of the matrix and fiber to ultrasonic propagation and scattering is discussed. Work begun on the characterization of wave propagation in graphite fiber/polymer matrix composites is described.

Smith, B. T.↗

Ultrasonic imaging of textured alumina

Ultrasonic images representing the bulk attenuation and velocity of a set of alumina samples were obtained by a pulse-echo contact scanning technique. The samples were taken from larger bodies that were chemically similar but were processed by extrusion or isostatic processing. The crack growth resistance and fracture toughness of the larger bodies were found to vary with processing method and test orientation. The results presented here demonstrate that differences in texture that contribute to variations in structural performance can be revealed by analytic ultrasonic techniques.

Stang, David B.↗

Radiographic and ultrasonic characterization of sintered silicon carbide

The capabilities were investigated of projection microfocus X-radiography, ultrasonic velocity and attenuation, and reflection scanning acoustic microscopy for characterizing silicon carbide specimens. Silicon carbide batches covered a range of densities and different microstructural characteristics. Room temperature, four point flexural strength tests were conducted. Fractography was used to identify types, sizes, and locations of fracture origins. Fracture toughness values were calculated from fracture strength and flaw characterization data. Detection capabilities of radiography and acoustic microscopy for fracture-causing flaws were evaluated. Applicability of ultrasonics for verifying material strength and toughness was examined.

Baaklini, G. Y.↗

High-frequency ultrasonic characterization of sintered silicon carbide

High-frequency 60- to 160-MHz ultrasonic nondestructive evaluation was used to characterize variations in density and microstructural constituents of sintered SiC bars. Ultrasonic characterization methods included longitudinal velocity, reflection coefficient, and precise attenuation measurements. The SiC bars were tailored to provide bulk densities ranging from 90 to 98 percent of theoretical, average grain sizes ranging from 3.0 to 12.0 microns, and average pore sizes ranging from 1.5 to 4.0 microns. Velocity correlated with specimen bulk density irrespective of specimen average grain size, average pore size, and average pore orientation. The attenuation coefficient was found to be sensitive to both density and average pore size variations, but was not affected by large differences in average grain size.

Baaklini, George Y.↗

Relaxation behavior of ultrasonic attenuation in YBa2Cu3O7

It is shown that temperature-dependent ultrasonic attenuation data of YBa2Cu3O7 at various frequencies exhibit anomalies at temperatures close to Tc. These attenuation maxima are found to be the result of a relaxation mechanism added on top of an unusual attenuation background. It is proposed that the grain boundary motions induced by the structural distortion and the propagation of sound waves enhances the energy dissipation around Tc. Whether this structural distortion is the consequence of the onset of a superconducting state remains undetermined. It is also possible that either a tunneling effect or the acoustoelectric effect contributes to sound energy dissipation. The temperature dependence of ultrasonic velocity shows a softening around Tc which may be an intrinsic property of high-temperature superconductors.

Sun, K. J.↗

Acousto-ultrasonics - An update

The application possibilities and limitations of acoustoultrasonics are reviewed. One of the most useful aspects of acousto-ultrasonics is its ability to assess degradation and damage states in composites. The sensitivity of the acousto-ultrasonic approach for detecting and measuring subtle but significant material property variations in composites has been demonstrated.

Vary, Alex↗

A theoretical basis for the acousto-ultrasonic evaluation of composite laminates

The application of the acousto-ultrasonic (AU) technique to composite laminates involves imparting a mechanical excitation to the surface of a composite plate to create a mechanical disturbance within the material. At the same time, a transducer is used at another location on the same or another surface of the material to sense vibrations (ultrasonic waves) caused by the disturbance. Experimental results are presented and related to concepts of through-thickness-transverse resonance and plate wave theory.

Kiernan, M. T.↗

Ultrasonic Imaging Of Deep Arteries

Swept-frequency sound replaces pulsed sound. Ultrasonic medical instrument produces images of peripheral and coronary arteries with resolutions higher and at depths greater than attainable by previous ultrasonic systems. Time-delay-spectrometry imager includes scanning, image-processing, and displaying equipment. It sweeps in frequency from 0 to 10 MHz in 20 ms, pauses for 5 ms, and repeats sweep. Intended for use in noninvasive detection and measurement of atherosclerotic lesions.

Rooney, James A.↗

Ultrasonic Abrasive Removal Of EDM Recast

Ultrasonic abrasive process removes layer of recast material generated during electrical-discharge machining (EDM) of damper pocket on turbine blade. Form-fitted tool vibrated ultrasonically in damper pocket from which material removed. Vibrations activate abrasive in pocket. Amount of material removed controlled precisely.

Mandel, Johnny L.↗

Subtle porosity variation in the YBa2Cu3O(7-x) high-temperature superconductor revealed by ultrasonic imaging

The characterization of global porosity variation within a nominally 93-percent-dense specimen of YBa2Cu3O(7-x) high-temperature superconductor is reported. With a computer-controlled scanning system, precision ultrasonic velocity measurements were obtained at 100 micron increments over an 8- by 8-mm area of the YBa2Cu3O(7-x) specimen. The measurements were used to form a color map of velocity variation across the scanned region of the specimen. Subtle velocity variation on the order of 1 percent was observed. The specimen was shown by experimental methods to be single-phase, untextured, and free of nonuniform residual microstresses. From this knowledge and an established velocity-density relationship, a likely conclusion is that the observed velocity variations are solely due to porosity variations of similar magnitude. Locating these subtle porosity variations is critical since they can result in an order of magnitude variation in J(sub c) for dense YBCO specimens. Thus, mapping the global porosity distribution within YBa2Cu3O(7-x) may reveal regions that have poorer superconducting properties. Ultrasonic velocity results are translated into useful microstructural information for the material scientist.

Roth, D. J.↗

Review and statistical analysis of the ultrasonic velocity method for estimating the porosity fraction in polycrystalline materials

A review and statistical analysis of the ultrasonic velocity method for estimating the porosity fraction in polycrystalline materials is presented. Initially, a semi-empirical model is developed showing the origin of the linear relationship between ultrasonic velocity and porosity fraction. Then, from a compilation of data produced by many researchers, scatter plots of velocity versus percent porosity data are shown for Al2O3, MgO, porcelain-based ceramics, PZT, SiC, Si3N4, steel, tungsten, UO2,(U0.30Pu0.70)C, and YBa2Cu3O(7-x). Linear regression analysis produced predicted slope, intercept, correlation coefficient, level of significance, and confidence interval statistics for the data. Velocity values predicted from regression analysis for fully-dense materials are in good agreement with those calculated from elastic properties.

Roth, D. J.↗

Correlation of the deply technique with ultrasonic imaging of impact damage in graphite-epoxy composites

The ultrasonic quantitative NDE of graphite-epoxy composites is difficult because of the inherent inhomogeneity of the material. An examination technique must discriminate between inherent scattering centers in an undamaged region and the scattering centers due to defects or damage. Two NDE techniques that can make this distinction were used to image and quantify the extent of damage resulting from a low-energy impact. These results were then compared with those from a destructive technique. The first NDE technique, polar backscatter, employed a nonzero polar angle insonifying method to reduce specular reflection from the surface of the sample; the second NDE technique used a normal-incidence ultrasonic beam. Results from both NDE methods were subsequently correlated with those from a destructive technique, the deply method. Both the qualitative and quantitative agreement of the methods was excellent.

Smith, B. T.↗

Ultrasonic Device Would Open Pipe Bombs

Piezoelectric ultrasonic transducer, energized by frequency generator and power supply, vibrates shell of pipe bomb while hardly disturbing explosive inner material. Frequency-control circuitry senses resonance in shell and holds generator at that frequency to induce fatigue cracking in threads of end cap. In addition to disarming bombs, ultrasonically induced fatigue may have other applications. In manufacturing, replaces some machining and cutting operations. In repair of equipment, cleanly and quickly disassembles corroded parts. In demolition of buildings used to dismember steel framework safely and controllably.

El-Raheb, Michael S.↗