At least 451 records · Page 25

An implantable blood pressure and flow transmitter.

A miniature totally implantable FM/FM telemetry system has been developed to simultaneously measure blood pressure and blood flow, thus providing an appreciation of the hemodynamics of the circulation to the entire body or to a particular organ. Developed for work with animal subjects, the telemetry system's transmission time is controlled by an RF signal that permits an operating life of several months. Pressure is detected by a miniature intravascular transducer and flow is detected by an extravascular interferometric ultrasonic technique. Both pressure and flow are calibrated prior to implanting. The pressure calibration can be checked after the implanting by cannulation; flow calibration can be verified only at the end of the experiment by determining the voltage output from the implanted sensing system as a function of several measured flow rates. The utility of this device has been established by its use in investigating canine renal circulation during exercise, emotional encounters, administration of drugs, and application of accelerative forces.

Rader, R. D.↗

On the lidar determination of atmospheric transmittance

A solution of the lidar equation is given with the aim of determining the attenuation coefficient of the atmosphere under conditions of the existence of a relation between it and the effective backscatter area. The errors of determining the attenuation coefficient from measurements of the echo signal power are analyzed. A proposed method of determining that coefficient by sounding with variable pulse lengths is examined.

Stepanenko, V. D.↗

Gyroflex data transmittal and data acquisition system analysis

Data obtained from the evaluation of GYROFLEX gyro is presented herein, along with a description of the data acquisition system. In addition, the appendices contain an analysis of the voltmeter used for data collection, and the filtering technique employed. It is shown that the test setup is satisfactory for testing GYROFLEX gyros.

Peckham, C.↗

Performance characteristics of the 12 GHz, 200 watt transmitter experiment package for CTS

The experiment package consists of a 200 W output stage tube (OST) powered by a power processing system (PPS). Descriptions of both the PPS and OST are given. The PPS provides the necessary voltages with a measured dc/dc conversion efficiency of 89 percent. The OST, a traveling wave tube with multiple collectors, has a saturated rf output power of 224 W and operates at an overall efficiency exceeding 40 percent over an 85 MHz bandwidth at 12 GHz. OST performance given includes frequency response, saturation characteristics, group delay, AM to PM conversion, inter-modulation distortion, and two channel gain suppression. Single and dual channel FM video performance is presented. It was determined that for 12 MHz peak to peak frequency deviation on each channel, dual channel FM television signals can be transmitted through the TEP at 60 W, each channel, with 40 MHz channel spacing (center to center).

Miller, E. F.↗

A multichannel biotelemetry transmitter utilizing a PCM subcarrier

Making use of the currently available integrated circuits, a miniature PCM telemetry system operating from one miniature 9-volt battery and drawing less than 5 milliamps has been constructed. The use of this PCM telemetry signal not only provides accurate data transmission, but requires a minimum of RF bandwidth. The serial format that results from multiplexing the input data allows the use of a single channel recorder with its cost savings over a multichannel tape recorder. An additional benefit of the PCM encoding is that the data is in digital format and is directly suitable for computer use.

Fryer, T. B.↗

Power processing system for a 200 watt communication satellite transmitter

A power processing system (PPS) for a communication satellite, high power (200W RF) multi-stage depressed collector, 12 GHz, traveling wave tube, is described. The PPS converts spacecraft bus power at a nominal voltage of 76 Vdc to the levels necessary for operating a ten-collector coupled cavity TWT requiring approximately 500 watts of input power. Regulated voltages of up to -11.3K Vdc are provided along with command, protection and telemetry signal conditioning circuits. Power processor interface requirements are set forth and a block diagram illustrating the basic approach utilized is presented. Overall performance, design characteristics and unique features are discussed. Thermal and mechanical interface requirements impacting on PPS design are described as well as the thermal control technique utilized for the overall PPS/TWT assembly.

Farber, B. F.↗

Voltage-offset reduction in data transmitters

Current source, which consists of inductor and two silicon diodes, is used to reduce output voltage offset and to make circuit less sensitive to conductance differences in output transistors.

Theall, C. E.↗

The mixture problem in computer mapping of terrain: Improved techniques for establishing spectral signature, atmospheric path radiance, and transmittance

The results of LANDSAT and Skylab research programs on the effects of the atmosphere on computer mapping of terrain include: (1) the concept of a ground truth map needs to be drastically revised; (2) the concept of training areas and test areas is not as simple as generally thought because of the problem of pixels that represent a mixture of terrain classes; (3) this mixture problem needs to be more widely recognized and dealt with by techniques of calculating spectral signatures of mixed classes, or by other methods; (4) atmospheric effects should be considered in computer mapping of terrain and in monitoring changes; and (5) terrain features may be used as calibration panels on the ground, from which atmospheric conditions can be determined and monitored. Results are presented of a test area in mountainous terrain of south-central Colorado for which an initial classification was made using simulated mixture-class spectral signatures and actual LANDSAT-1-MSS data.

Smedes, H. W.↗

Improving FM transmitter power and efficiency

Amplifier tracks oscillator frequency allowing narrow band high Q circuit to be used, increasing wide deviation FM transmission efficiency and power output, and suppressing spurious output frequencies system. Tracking oscillator and amplifier act like wideband circuitry with narrow-band advantages.

Honnell, M. A.↗

Ultrashort pulse solid-state transmitter development

A pulsed, actively mode-locked, pulse-transmission-mode (PTM) Q-switched Nd:YAG laser has been developed for a planned NASA spaceborne precision ranging system. The laser emits single, 150-psec, 20-mJ pulses at 10 pulses per second at 1.064 micrometers.

Harper, L. L.↗

Cooling Waveguide Flanges in Microwave Transmitters

Flang appendage circulates coolant for conductive heat removal. Flange appendage bore accomodates coolant tube. O-ring surrounds bore; when adjacent waveguide sections are bolted together, continuous conduit is formed for coolant. Pressure release groove in modified flange prevents coolant from entering waveguide should O'ring seal fail.

Chen, B. C.↗

A 20-GHz IMPATT transmitter, summary

A three stage IMPATT diode amplifier capable of a 16 W CW output and a 2 dB bandwidth of 117 MHz was developed. On the component side, high performance circulators with a 0.2 dB insertion loss and bandwidth of 5 GHz were fabricated. State of the art GaAs IMPATT diodes incorporating diamond heat sink and double Read doping profile were also developed. The diodes are capable of a 2.5 W CW output. A few diodes achieved power outputs as high as 3 W. On the circuit side, high gain (up to 12 dB per stage) single diode, multituned circuits capable of 2 GHz and 930 MHx bandwidth were developed as the first and second stages, respectively, of the amplifier. A 12 diode waveguide cavity combiner was developed as the output stage. The output stage utilized commercially available single drift GaAs IMPATT diodes.

Source record↗

30/20 GHz spacecraft GaAs FET solid state transmitter for trunking and customer-premise-service application

Sixteen 30 dB 0.5 W amplifier modules were combined to satisfy the requirement for a graceful degradation. If one module fails, the output power drops by only 0.43 dB. Also, by incorporating all the gain stages within the combiner the overall combining efficiency is maximized. A 16 way waveguide divider combiner was developed to minimize the insertion loss associated with such a large corporate feed structure. Tests showed that the 16 way insertion loss was less than 0.5 dB. To minimize loss, a direct transition from waveguide to microstrip, using a finline on duroid substrate, was developed. The FETs fabricated on MBE grown material, demonstrated superior performances. For example, a 600 micrometer device was capable of 320 mW output power with 5 dB gain and 26.6% efficiency at 21 GHz. The 16 module amplifier gave 8.95 W saturated output power with 30 dB gain. The overall efficiency was 9%. The 3 dB bandwidth was 2.5 GHz. At 17.7 GHz the amplifier had 5 W output power and at 20.2 GHz it still had 4.4 W.

Saunier, P.↗