Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Effect of substrate temperature deposition on the thermal and optical performance of ZnO thin films as thermal interface material

ZnO thin films were deposited onto aluminium substrates at different substrate temperatures from 300 to 450 °C by chemical vapour deposition method using zinc acetate dihydrate as precursor. The effects of substrate temperatures on the thermal and optical performances of a light emitting diode package were investigated. The thermal transients show that thin film deposited at 400 °C has the lowest thermal resistance and junction temperature with a different difference of 1.3421 K/W and 2.7 °C respectively. The correlated colour temperature of the LED interfaced with ZnO prepared at 400 °C showed a good agreement with the thermal performance and exhibited the lowest correlated colour temperature as the driving current increases. The luminance shows that bare Al demonstrate the lowest luminosity compare to the coated thin film as TIM. The excess heat that trapped within the air gaps affects the heat flow. This eventually affects the luminosity of the LED. Furthermore, the AFM measurements of CVD 3 (400 °C) samples show low roughness values which contribute to good thermal resistance and junction temperature values. Overall, the present study shows that the performance of the LED has been enhanced with ZnO thin film used as TIM.

36 MATERIALS SCIENCE↗

Advanced Liquid Cooling for a Traction Drive Inverter Using Jet Impingement and Microfinned Enhanced Surfaces: Preprint

Jet impingement on plain and micro-finned enhanced surfaces was compared to a traditional channel flow configuration. The jets provide localized cooling to areas heated by the insulated-gate bipolar transistor and diode devices. Enhanced microfinned surfaces increase surface area and thermal performance. Using lighter materials and designing the fluid path to manage pressure losses increases overall performance while reducing weight, volume, and cost. Powering four diodes in the center power module of the inverter and computational fluid dynamics (CFD) modeling was used to characterize the baseline as well as jet-impingement-based heat exchangers. CFD modeling showed the thermal performance improvements should hold for a fully powered inverter. Increased thermal performance was observed for the jet-impingement configurations when tested at full inverter power (40 to 100 kW output power) on a dynamometer. The reliability of the jets and enhanced surfaces over time was also investigated. Experimentally, the junction-to- coolant thermal resistance was reduced by up to 12.5% for jet impingement on enhanced surfaces s compared to the baseline channel flow configuration. Base plate-to-coolant (convective) resistance was reduced by up to 37.0% for the jet-based configuration compared to the baseline, suggesting that while improvements to the cooling side reduce overall resistance, reducing the passive stack resistance may contribute to lowering overall junction-to-coolant resistance. Full inverter power testing showed reduced thermal resistance from the middle of the module baseplate to coolant of up to 16.5%. Between the improvement in thermal performance and pumping power, the coefficient of performance improved by up to 13% for the jet-based configuration.

30 DIRECT ENERGY CONVERSION↗

Thermal-hydraulic Performance of Emerging Low GWP Refrigerant Mixture under Flow Boiling in Brazed Plate Heat Exchangers

The hydrofluorocarbon (HFC) refrigerants used in the current refrigeration systems are facing a phase-down due to their higher greenhouse effect resulting in global warming, and thus HVAC&R industry has undergone a transition to low Global Warming Potential (GWP) refrigerants. Refrigerant mixtures are attractive alternatives since their composition can be tailored to comply with environmental regulations while preserving favorable thermophysical properties. However, the new low-GWP zeotropic mixture refrigerants have two or more components with different saturation temperatures at the same pressure level, known as temperature glide, which can cause the degradation of the overall heat transfer performance. The brazed plate heat exchangers (BPHX) provide excellent heat transfer performance due to a compact design and are used in several air-conditioning and refrigeration applications. In this study, flow boiling heat transfer and the associated pressure drop of the refrigerant mixture in a vertical BPHX were experimentally investigated. The single-phase water-to-water experiments were conducted in the tested heat exchanger with a counter-flow configuration. The flow boiling experiments charged with R-134a and R-454C were then performed in a pumped refrigerant loop to evaluate its thermal-hydraulic performance. Furthermore, parametric studies of various heat fluxes, mass fluxes, vapor qualities, and saturation temperatures were also conducted.

Yang, Cheng-Min↗

Thermal-hydraulic performance of metal foam heat exchangers under dry operating conditions

High porosity metal foams with novel thermal, mechanical, electrical, and acoustic properties are being more widely adopted for application. Due to their large surface-area-to-volume ratio and complex structure which induces better fluid mixing, boundary layer restarting and wake destruction, they hold promise for heat transfer applications. In this study, the thermal-hydraulic performance of open-cell aluminum metal foam heat exchanger has been evaluated. The impact of flow conditions and metal foam geometry on the heat transfer coefficient and gradient have been investigated. Metal foam heat exchanger with same geometry (face area, flow depth and fin dimensions) consisting of four different type of metal foams have been built for the study. Experiments are conducted in a closed-loop wind tunnel at different flow rate under dry operating condition. Metal foams with a smaller pore size (40 PPI) have a larger heat transfer coefficient compared to foams with a larger pore size (5 PPI). However, foams with larger pores result in relatively smaller pressure gradients. Current thermal-hydraulic modeling practices have been reviewed and potential issues have been identified. Permeability and inertia coefficients are determined and compared to data reported in open literature. Finally, on the basis of the new experimental results, correlations are developed relating the foam characteristics and flow conditions through the friction factor f and the Colburn j factor.

36 MATERIALS SCIENCE↗

Shape optimization of a printed-circuit heat exchanger to enhance thermal-hydraulic performance

Printed circuit heat exchanger (PCHE) is recently considered as a recuperator for the high temperature gas cooled reactor. In this work, the zigzag-channels of a PCHE have been optimized by using three-dimensional Reynolds-Averaged Navier-Stokes (RANS) analysis and response surface approximation (RSA) modeling technique to enhance thermal-hydraulic performance. Shear stress transport turbulence model is used as a turbulence closure. The objective function is defined as a linear combination of the functions related to heat transfer and friction loss of the PCHE, respectively. Three geometric design variables viz., the ratio of the radius of the fillet to hydraulic diameter of the channels, the ratio of wavelength to hydraulic diameter of the channels, and the ratio of wave height to hydraulic diameter of the channels, are used for the optimization. Design points are selected through Latin-hypercube sampling. The optimal design is determined through the RSA model which uses RANS derived calculations at the design points. The results show that the optimum shape enhances considerably the thermal-hydraulic performance than a reference shape. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Structural-Thermal-Optical-Performance (STOP) Analysis

The presentation will be given at the 26th Annual Thermal Fluids Analysis Workshop (TFAWS 2015) hosted by the Goddard Spaceflight Center (GSFC) Thermal Engineering Branch (Code 545). A STOP analysis is a multidiscipline analysis, consisting of Structural, Thermal and Optical Performance Analyses, that is performed for all space flight instruments and satellites. This course will explain the different parts of performing this analysis. The student will learn how to effectively interact with each discipline in order to accurately obtain the system analysis results.

Optical↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Thermal-hydraulic performance of a high-temperature zigzag-channel printed circuit heat exchanger - 18563

Advanced nuclear reactors, such as high-temperature gas-cooled reactors (HTGRs) from the Generation IV nuclear systems, are designed with the capability of delivering high-pressure, high-temperature helium to power conversion units for electricity generation and industrial plants for process heat applications. The efficiency of the electricity generation and process heat applications of HTGRs is critically dependent upon an intermediate heat exchanger (IHX), which is a key component in transferring thermal energy from the primary coolant to a secondary coolant. Printed circuit heat exchangers (PCHEs) are promising to be employed in HTGR designs due to their capability for high-temperature, high-pressure applications and compactness. In the current study, a laboratory-scale zigzag-channel PCHE was fabricated and its heat transfer and pressure drop characteristics were investigated experimentally in a high-temperature helium test facility (HTHF). A commercial computational fluid dynamics (CFD) code, STARCCM+, was used to simulate the thermal-hydraulic performance of the fabricated PCHE with a simplified geometry model. Comparisons showed some differences between experimental data available for the zigzag-channel PCHE and the numerical results. Local thermal-hydraulic performance analyses indicated that fully-developed flow conditions and periodic changes were not observed, which could be attributed to the temperature variations along the flow channels, resulting in large fluid property variations. In addition, the effects of sharp-edged or rounded zigzag channel geometry were numerically evaluated. The use of rounded corners at each bend of the channels is recommended since this method can reduce the pressure drop on both the hot and cold sides of the heat exchanger while maintaining similar heat transfer capabilities. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Heat transfer and pressure drop in hexagonal ducts with surface dimples

Measurements of detailed Nusselt number (Nu) distributions and pressure drop coefficients (f) for four hexagonal ducts with smooth and dimpled walls are performed to comparatively examine the thermal performances of three sets of dimpled walls with concave-concave, convex-convex and concave-convex configurations at Reynolds numbers (Re) in the range of 900-30,000. A set of selected experimental data illustrates the influences of dimple configuration and Re on the detailed Nu distributions, the area-averaged Nu over developed flow region (Nu-bar) and the pressure drop coefficients. Relative enhancements of Nu and f from the smooth-walled references (Nu{sub {infinity}} and f{sub {infinity}}) along with the thermal performance factor ({eta}) defined as (Nu-bar/Nu{sub {infinity}})/(f/f{sub {infinity}}){sup 1/3} are examined. Nu-bar and f correlations are individually obtained for each tested hexagonal duct using Re as the controlling parameter. (author)

42 ENGINEERING↗

Modeling of transient conduction in building envelope assemblies: A review

As buildings age, retrofits are becoming an increasingly important topic for the ever-growing and aging existing building stock. To compare designs or evaluate in-service building envelopes, thermal modeling is utilized to evaluate the thermal performance of envelope assemblies; however, it can be difficult to model the thermal performance of as-built assemblies due to degradation or missing documentation. To address this issue, inverse modeling can be applied to infer the properties of as-built envelope assemblies. This paper presents a review of the literature and published methods to model and infer the transient conductive performance of building envelopes. This review serves as a survey of existing transient conduction algorithms to evaluate performance, computational speed, and relevance for inverse modeling applications. In addition to the literature review, this work also evaluates the computational performance of the most prevalent transient conduction algorithms against the ASHRAE 1052RP toolkit to assess inverse modeling potential. This methodology serves as a foundation for future research to characterize the transient thermal performance of as-built building envelope assemblies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerothermodynamic performance and thermal protection design for blunt re-entry bodies at L/D = 0.3

Aerodynamic heating and thermal protection design analyses were performed for three blunt re-entry bodies at an L/D = 0.3 returning from low earth orbit. These configurations consisted of a scaled up Apollo command module, a Viking re-entry vehicle, and an Aeroassist Flight Experiment (AFE) aerobrake, each with a maximum diameter of 4.42 m. The aerothermodynamic analysis determined the equilibrium stagnation point heating rate and heat load for nominal and 3-sigma re-entry trajectories and the distribution of heating along the pitch and yaw planes for each of the vehicles at the time of highest heat flux. Using the predicted heating rates and heating distributions, a Thermal Protection System (TPS) design with flight certified materials was tailored for each of the configurations. Results indicated that the heating to the corner of the Viking aeroshell would exceed current limits of reusable tile material. Also, the maximum heating for the AFE would be 15 percent greater than the maximum heating for the Apollo flying the same trajectory. TPS designs showed no significant advantage in TPS weight between the different vehicles; however, heat-shield areal density comparisons showed the Apollo configuration to be the most efficient in terms of TPS weight.

Caram, Jose M.↗

Purging of a tank-mounted multilayer insulation system by gas diffusion

The investigation was conducted on a multilayer insulation (MLI) system mounted on a spherical liquid hydrogen propellant tank. The MLI consisted of two blankets of insulation each containing 15 double-aluminized Mylar radiation shields separated by double silk net spacers. The gaseous nitrogen initially contained within the MLI system and vacuum chamber was purged with gaseous helium introduced both underneath the MLI and into the vacuum chamber. The MLI panels were assumed to be purged primarily by means of gas diffusion. Overall, test results indicated that nitrogen concentrations well below 1 percent could be achieved everywhere within the MLI system. Typical times to achieve 1 percent nitrogen concentration within the MLI panels ranged from 69 minutes at the top of the tank to 158 minutes at the bottom of the tank. Four space-hold thermal performance tests indicated no significant thermal degradation of the MLI system had occurred due to the purge tests conducted. The final measured heat input attributed to the MLI was 7.23 watts as compared to 7.18 watts for the initial baseline thermal performance test.

Sumner, I. E.↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Effects of Photonic Curing Processing Conditions on MAPbI 3 Film Properties and Solar Cell Performance

Thermal annealing is the most used postdeposition materials processing method in laboratory research, but due to its slow speed and high energy cost, it is not compatible with the upscaling and commercialization of perovskite solar cell (PSC) manufacturing. Here, we adapt photonic curing (PC), which uses millisecond light pulses to deliver energy to the sample, to replace thermal annealing for crystallization of methylammonium lead iodide (MAPbI 3 ) films and rapid fabrication of PSCs. We study how PC conditions affect the outcome of MAPbI 3 conversion from the precursor to the crystalline perovskite phase by evaluating the films’ optical, crystalline, and morphological properties, as well as PSC performance. The results are understood using simulated film temperature profiles. We show that MAPbI 3 is readily converted under a wide range of PC conditions. While previous reports all used short pulses (<3 ms), we find that longer pulses produce more dense films and higher-performing PSCs. We achieve a champion power conversion efficiency in a PC-processed MAPbI 3 PSC of 11.26% under forward scan and 10.34% under reverse scan, with the processing time for the MAPbI 3 layer reduced by 30,000-fold, from 10 min to 20 ms. Using a 6 in. lamp, spatial uniformity tests show a cross-web efficiency variation of 5%. Our results indicate that using longer pulse lengths, >10 ms, is the best PC strategy for perovskite conversion, and PC is a promising annealing method for large-area, high-throughput PSC manufacturing.

14 SOLAR ENERGY↗