Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Preliminary report on applications of machine learning techniques to the Nevada play fairway analysis

We are applying machine learning (ML) techniques, including training set augmentation and artificial neural networks, to mitigate key challenges in the Nevada play fairway project. The study area includes ~85 active geothermal systems as potential training sites and >12 geologic, geophysical, and geochemical features. The main goal is to develop an algorithmic approach to identify new geothermal systems in the Great Basin region. Major objectives include: 1) integrate ML techniques into the geothermal community; 2) develop open community datasets, whereby all play fairway and ML datasets and algorithms are publicly released and available for modification by various user groups; 3) identify data acquisition targets with high value for future work; 4) identify new signatures to detect blind geothermal systems; and 5) foster new capabilities for characterizing subsurface temperature and permeability. Initially, ML techniques are being applied to the same play fairway datasets and workflow. ML will then be applied to both enhanced and additional datasets, with modification of the PFA workflow to incorporate the new datasets. Finally, ML will be applied to define new workflows using the enhanced and additional datasets. An algorithmic approach that empirically learns to estimate weights of influence for diverse parameters can potentially scale and perform better than the play fairway analysis. Initial work on this project has involved 1) evaluating potential positive and negative training sites, 2) transformation of datasets into formats suitable for ML, and 3) initial development and testing of ML techniques.

58 GEOSCIENCES↗

Detection of Stealthy False Data Injection Attacks in Unobservable Distribution Networks

In this paper, a composite scheme is proposed for detecting stealthy data manipulation attacks on distribution system which is unobservable with standard least squares based state estimators. This technique has three stages where the process of data imputation, voltage phasor estimation and the bad data detection are carried out in a systematic manner. The proposed approach is then integrated with moving target defense strategies which perturbs the network parameters to reveal stealthy false data injection attacks. The proposed approach is tested is validated on a three-phase, unbalanced 37-node distribution system and its results are presented. It is shown that the proposed approach has the ability to accurately detect the presence of FDI attacks using limited measurements (i.e., the test system is unobservable).

Rajasekaran, James K.↗

Host-Directed, Bioelectronic Immunomodulation for Protection Against Emerging Pathogens

Acute care of patients with severe infections often relies on systemic administration of pharmaceuticals and monitoring of complex physiological symptoms to identify immune system dysfunction, which can lead to increased mortality. Furthermore, determining disease-specific treatment plans often leads to a delay in patient care. To address this, we proposed an immune modulation system that electrically detects and responds to a patient’s immune system status, creating an agnostic means of treating illness and infection. Two pieces of hardware were developed for this task: a minimally-invasive sensor and a vagus nerve stimulator. Stimulation of the vagus nerve is known to modulate the immune system. The sensor is a microfabricated, silicon-based microneedle array capable of interfacing with interstitial fluid to detect small molecules such as inflammatory proteins (cytokines) and pharmaceuticals (vancomycin). Process optimization to manufacture the needles refined the silicon etch process, creating needle patches long enough to penetrate skin and reach interstitial fluid. The needles were tested for mechanical strength and stability, and did not shatter when inserted into skin models. The needles are coated with a thin film metal, turning them into electrodes for electrochemical sensing of our target molecules. We hybridized aptamers to the surface of the electrode to act as the sensing layer and were able to detect changes in the conformation of the aptamer electrochemically in the presence of the target molecule. The stimulator was a cuff electrode that encircled the vagus nerve. Rodent studies were conducted in which rodents were exposed to an inflammatory event and vagus nerve stimulation (VNS) was applied. It was demonstrated that optimized electrical stimulation of the vagus nerve created measurably different levels of cytokines in blood samples, and certain cytokines released during the inflammatory event were either upregulated or downregulated. In sum, this project successfully developed new platforms and technologies that can, with further development, enable better temporal insight into biomarker changes in the body, letting healthcare providers know of possible immune system dysfunction before they are detected physiologically. We also demonstrated the value of VNS and its possible use in treating immune system response to inflammation and illness.

59 BASIC BIOLOGICAL SCIENCES↗

Nanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

47 OTHER INSTRUMENTATION↗

Efficiency Studies of Fast Neutron Tracking Using MCNP

Fast neutron identification and spectroscopy is of great interest to nuclear physics experiments. Using the neutron elastic scattering, the fast neutron momentum can be measured. Wang and Morris introduced the theoretical concept that the initial fast neutron momentum can be derived from up to three consecutive elastic collisions between the neutron and the target, including the information of two consecutive recoil ion tracks and the vertex position of the third collision or two consecutive elastic collisions with the timing information. Here, we also include the additional possibility of measuring the deposited energies from the recoil ions. In this paper, we simulate the neutron elastic scattering using the Monte Carlo N-Particle Transport Code (MCNP) and study the corresponding neutron detection and tracking efficiency. The corresponding efficiency and the scattering distances are simulated with different target materials, especially natural silicon (92.23%28Si, 4.67%29Si, and 3.1%30Si) and helium-4 (4He). The timing of collision and the recoil ion energy are also investigated, which are important characters for the detector design. We also calculate the ion traveling range for different energies using the software, “The Stopping and Range of Ions in Matter (SRIM)”, showing that the ion track can be most conveniently observed in 4He unless sub-micron spatial resolution can be obtained in silicon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advances and Challenges in Fluorescence in situ Hybridization for Visualizing Fungal Endobacteria

We report that Several bacteria have long been known to interact intimately with fungi, but molecular approaches have only recently uncovered how cosmopolitan these interactions are in nature. Currently, bacterial–fungal interactions (BFI) are inferred based on patterns of co-occurrence in amplicon sequencing investigations. However, determining the nature of these interactions, whether the bacteria are internally or externally associated, remains a grand challenge in BFI research. Fluorescence in situhybridization (FISH) is a robust method that targets unique sequences of interest which can be employed for visualizing intra-hyphal targets, such as mitochondrial organelles or, as in this study, bacteria. We evaluate the challenges and employable strategies to resolve intra-hyphal BFI to address pertinent criteria in BFI research, such as culturing media, spatial distribution of bacteria, and abundance of bacterial 16S rRNA copies for fluorescent labeling. While these experimental factors influence labeling and detection of endobacteria, we demonstrate how to overcome these challenges thorough permeabilization, appropriate media choice, and targeted amplification using hybridization chain reaction FISH. Such microscopy imaging approaches can now be utilized by the broader research community to complement sequence-based investigations and provide more conclusive evidence on the nature of specific bacterial–fungal relationships.

59 BASIC BIOLOGICAL SCIENCES↗

Sensing Techniques for Organochlorides through Intermolecular Interaction with Bicyclic Amidines

Toxic organochloride molecules are widely used in industry for various purposes. With their high volatility, the direct detection of organochlorides in environmental samples is challenging. Here, a new organochloride detection mechanism using 1,5-diazabicyclo[4.3.0]non-5-ene (DBN) is introduced to simplify a sensing method with higher detection sensitivity. Three types of organochloride compounds-trichloroethylene (TCE), dichloromethane (DCM), and dichlorodiphenyltrichloroethane (DDT)—were targeted to understand DCM conjugation chemistry by using nuclear magnetic resonance (NMR) and liquid chromatography with a mass spectrometer (LC-MS). 13C-NMR spectra and LC-MS data indicated that DBN can be labeled on these organochloride compounds by chlorine–nitrogen interaction. Furthermore, to demonstrate the organochloride sensing capability, the labeling yield and limit of detection were determined by a colorimetric assay as well as micellar electrokinetic chromatography (MEKC). The interaction with DBN was most appreciable for TCE, among other organochlorides. TCE was detected at picomolar levels, which is two orders of magnitude lower than the maximum contaminant level set by the United States Environmental Protection Agency. MEKC, in conjunction with this DBN-labeling method, enables us to develop a field-deployable sensing platform for detecting toxic organochlorides with high sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tuning gold-based surface functionalization for streptavidin detection: A combined simulative and experimental study

A rationally designed gold-functionalized surface capable of capturing a target protein is presented using the biotin–streptavidin pair as a proof-of-concept. We carried out multiscale simulations to shed light on the binding mechanism of streptavidin on four differently biotinylated surfaces. Brownian Dynamics simulations were used to reveal the preferred initial orientation of streptavidin over the surfaces, whereas classical molecular dynamics was used to refine the binding poses and to investigate the fundamental forces involved in binding, and the binding kinetics. We assessed the binding events and the stability of the streptavidin attachment through a quartz crystal microbalance with dissipation monitoring (QCM-D). The sensing element comprises of biotinylated polyethylene glycol chains grafted on the sensor’s gold surface via thiol-Au chemistry. Finally, we compared the results from experiments and simulations. We found that the confined biotin moieties can specifically capture streptavidin from the liquid phase and provide guidelines on how to exploit the microscopic parameters obtained from simulations to guide the design of further biosensors with enhanced sensitivity.

59 BASIC BIOLOGICAL SCIENCES↗

Advances in PFAS Monitoring and Remediation Using a Functionalized Material Approach

The growing global concerns about the effects to public health from human exposure to per- and polyfluoroalkyl substances (PFAS) motivates the development of strategies for reliable monitoring of PFAS in environmental streams, as well as for their rapid, effective removal if detected. For the continuous PFAS monitoring, an inexpensive, field-deployable, in situ sensor is urgently needed; yet the prevalent in situ techniques often struggle to strike a balance between the practical sensitivity and selectivity demands of the real world. Similarly, for effective PFAS removal, strategies for their fast, selective, and quantitative capture are desired, yet the present commercially available sorbents are unable to meet the requirements of rapid, quantitative capture of all PFAS components, and are notably inefficient in removing the more toxic smaller chains. To address these twin challenges, Pacific Northwest National Laboratory is developing strategies for improved detection and remediation of PFAS. For the rapid, selective, quantitative removal of PFAS from environmental streams, the strategy relies on designing capture probes with exclusively tailored electronic and spatial affinities for the PFAS that are able to selectively capture them from environmental streams. For the in situ detection and quantification of PFAS in complex, multicomponent matrices such as groundwater, the approach relies on the targeted capture of specific PFAS by these PFAS-specific capture probes immobilized on a platform. The platform acts as an electrode to directly measure PFAS concentration through a proportional change in electrical response upon their capture. A combination of optimization of platform design and incorporation of additional, sensitive detection modalities have allowed us to achieve detection limits as low as 0.5 ng/L for detection of PFAS compounds (compared to the 70 ng/L Health Advisory Limit of the U.S. Environmental Protection Agency).

Per- and poly-fluorinated alkyl substances (PFAS),↗

Advances in PFAS Monitoring and Remediation Using a Functionalized Material Approach - 20080

The growing global concerns about the effects to public health from human exposure to per- and polyfluoroalkyl substances (PFAS) motivates the development of strategies for reliable monitoring of PFAS in environmental streams, as well as for their rapid, effective removal if detected. For the continuous PFAS monitoring, an inexpensive, field-deployable, in situ sensor is urgently needed; yet the prevalent in situ techniques often struggle to strike a balance between the practical sensitivity and selectivity demands of the real world. Similarly, for effective PFAS removal, strategies for their fast, selective, and quantitative capture are desired, yet the present commercially available sorbents are unable to meet the requirements of rapid, quantitative capture of all PFAS components, and are notably inefficient in removing the more toxic smaller chains. To address these twin challenges, Pacific Northwest National Laboratory is developing strategies for improved detection and remediation of PFAS. For the rapid, selective, quantitative removal of PFAS from environmental streams, the strategy relies on designing capture probes with exclusively tailored electronic and spatial affinities for the PFAS that are able to selectively capture them from environmental streams. For the in situ detection and quantification of PFAS in complex, multicomponent matrices such as groundwater, the approach relies on the targeted capture of specific PFAS by these PFAS-specific capture probes immobilized on a platform. The platform acts as an electrode to directly measure PFAS concentration through a proportional change in electrical response upon their capture. A combination of optimization of platform design and incorporation of additional, sensitive detection modalities have allowed us to achieve detection limits as low as 0.5 ng/L for detection of PFAS compounds (compared to the 70 ng/L Health Advisory Limit of the U.S. Environmental Protection Agency). (authors)

47 OTHER INSTRUMENTATION↗

Too Good to Be True? Evaluation of Colonoscopy Sensitivity Assumptions Used in Policy Models

Background: Models can help guide colorectal cancer screening policy. Although models are carefully calibrated and validated, there is less scrutiny of assumptions about test performance. Methods: We examined the validity of the CRC-SPIN model and colonoscopy sensitivity assumptions. Standard sensitivity assumptions, consistent with published decision analyses, assume sensitivity equal to 0.75 for diminutive adenomas (<6 mm), 0.85 for small adenomas (6–10 mm), 0.95 for large adenomas (≥10 mm), and 0.95 for preclinical cancer. We also selected adenoma sensitivity that resulted in more accurate predictions. Targets were drawn from the Wheat Bran Fiber study. In the study, we examined how well the model predicted outcomes measured over a three-year follow-up period, including the number of adenomas detected, the size of the largest adenoma detected, and incident colorectal cancer. Results: Using standard sensitivity assumptions, the model predicted adenoma prevalence that was too low (42.5% versus 48.9% observed, with 95% confidence interval 45.3%–50.7%) and detection of too few large adenomas (5.1% versus 14.% observed, with 95% confidence interval 11.8%–17.4%). Predictions were close to targets when we set sensitivities to 0.20 for diminutive adenomas, 0.60 for small adenomas, 0.80 for 10- to 20-mm adenomas, and 0.98 for adenomas 20 mm and larger. Conclusions: Colonoscopy may be less accurate than currently assumed, especially for diminutive adenomas. Alternatively, the CRC-SPIN model may not accurately simulate onset and progression of adenomas in higher-risk populations. Impact: Misspecification of either colonoscopy sensitivity or disease progression in high-risk populations may affect the predicted effectiveness of colorectal cancer screening. When possible, decision analyses used to inform policy should address these uncertainties.

60 APPLIED LIFE SCIENCES↗

Search for dark matter decaying to two displaced muons produced in proton-proton collisions at 13 TeV with the CMS detector, and for dark photons produced in electron-positron fixed-target collisions at 500 MeV with the PADME detector

Two novel searches for dark matter using particle accelerators are presented. The first is a search for inelastically-coupled dark matter with the CMS detector at CERN, relying on 137 fb$^{-1}$ of proton-proton collision data collected at 13 TeV center-of-mass energy between 2016 and 2018. The search strategy exploits the striking signature expected of inelastic dark matter: a pair of displaced, soft, and narrow muons collimated with missing transverse momentum and recoiled off an initial-state radiation jet. This is the first search for inelastic dark matter at a hadron collider. The second experiment is PADME, a small-scale detector to search for dark photons located in Frascati, Italy. PADME seeks to detect the production of dark photons in positron-electron collisions with a stationary diamond target and a 500 MeV positron beam. The missing-mass technique employed in the experiment relies on constraining all four-momenta in the system except for the dark photon and lookin g for a bump in the resulting invariant mass distribution corresponding to the dark photon's mass. The projected sensitivity for both experiments is compared in the context of highlighting the need for a comprehensive experimental search program for dark matter. Both analyses expect first public results by the end of 2020.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a ß emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly ?-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

Noble liquid detectors, Dark Matter detectors, Cry↗

Adaptive Narrowband Damping for Improving Harmonic Stability of Modular Multilevel Converter: Preprint

Harmonic instability events between modular multilevel converter (MMC) and ac systems have been widely reported in recent years. To resolve it, this paper proposes an adaptive narrowband damping control that automatically programs, adds and adjusts damping around the oscillation frequency when detect the oscillation. The paper first presents a low-pass filter design for MMC control loops, which pushes all negative damping of MMC impedance down to the medium frequency range (< approximately 1000 Hz). This makes narrowband damping can be more targeted and easier to design because multiple harmonic oscillations are avoided. An adaptive damping control that uses online oscillation detection is then proposed, which can automatically configure the narrowband damper to provide damping to the MMC at the detected oscillation frequency. In contrast to existing narrowband damping methods, the proposed adaptive narrowband damper adjusts the damping gain (e.g., to zero when system resonance disappears) and the width of the damping range automatically based on continuous monitoring of system resonance conditions. Electromagnetic transient (EMT) simulation results validate the efficacy of the proposed method in two typical MMC-based power systems.

active damping↗

Do we have globally representative data to understand soil processes?

Understanding and modeling soils and soil organic matter (SOM) are central to a variety of human needs, from food production to ecosystem management. Soil data have been collected for over a century, but the global spatial and process representativeness of soil data remains unclear. We assessed the representativeness of currently available soil data that could be used to understand a variety of SOM processes. We used 16 open-source soil databases and data from over 281,000 unique locations globally, categorizing the databases into three main data types necessary to understand SOM processes: soil carbon stocks and fluxes, mechanistic drivers of these stocks and fluxes, and soil carbon gain or loss potential. We found that stock and driver data have extensive global coverage. However, data on soil carbon gain or loss potential, particularly data describing change in soils over time such as time series data, are severely limited in their global coverage. We conclude that while significant strides have been made in measuring soil carbon stocks and fluxes, and their drivers, we are limited in global data related to changes in soils over time. Our recommendations for soil data generators are to ensure precise metadata reporting and prioritizing sampling in underrepresented areas like tropical, arctic, mountainous, wetland and arid regions. We also encourage designing revisit schemes that explicitly support change detection and reporting multi-modal datasets that can aid in model development. Targeted measurement of low coverage soil data types and regions is necessary for a range of applications including current and future biogeochemical predictions, and their management and policy implications.

carbon fluxes↗

Mass reconstruction of heavy neutral leptons from stopped mesons

Heavy neutral leptons (HNLs), depending on their mass and mixing, can be efficiently produced in meson decays from the target or absorber in short- to medium-baseline accelerator neutrino experiments, leaving detectable signals through their decays inside the neutrino detectors. We show that the currently running ICARUS experiment at Fermilab can reconstruct the HNL mass and explore new HNL parameter space in the mass range of 70–190 MeV. The mass reconstruction is enabled by two ingredients: (i) simple two-body kinematics of HNL production from stopped kaon decays at the NuMI absorber, followed by HNL decay into a charged-lepton pair and neutrino at the detector, and (ii) high resolution of Liquid Argon Time Projection Chamber (LArTPC) detectors in reconstructing final state particles. Our mass reconstruction method is robust under realistic energy resolution and angular smearing of the charged leptons, and is applicable to any LArTPC detector. We also discuss the synergy between ICARUS and future facilities like DUNE near detector and PIP-II beam dump in probing the HNL parameter space. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-Time Multi-Vehicle Multi-Camera Tracking with Graph-Based Tracklet Features

An essential application in intelligent transportation systems is multi-target multi-camera tracking (MTMCT), where the target’s activity is tracked from different cameras. Although the tracking-by-detection scheme is the primary paradigm in MTMCT, the object association information from the video frames is lost. This is mainly because the multi-camera multi-object matching uses the information from the video frames separately. To solve this problem and leverage this association information, we propose an MTMCT framework, where features are built in the form of a graph and a graph similarity algorithm is used to match multi-camera objects. In this paper, we focus on the real-time scenario, where only the past images are used to match an object. Our method achieves an IDF1 score (the ratio of the number of correctly identified objects to the number of ground truth and average objects) of 0.75 with a rate of 14 frames per second (fps).

Engineering↗