Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Water desalination through the dewpoint evaporative system

This paper presents the first numerical analysis of a novel Dew Point Desalination unit (DPD), which utilizes the phenomenon of the evaporative cooling process to minimize energy consumption. The proposed solution is based on a modular structure, which allows it to obtain any required water production capacity. The analyses for various operational parameters and various climatic conditions are based on the numerical simulations conducted using a validated mathematical model. The system performance was described with different factors, including specific energy consumption (SEC) and daily water production rate respected to 1 m^3*s^-1 of passing air stream (DWP). It is shown that the DPD system can operate in almost every climate zone, and the desalinated water production consumes less than 1.5 kWh*m^-3 of electric energy It is noted the best performance of the DPD system is achieved in the semi-arid, desert and subtropical climate zones. In these climate zones, the 2-stage DPD system allows the production of desalinated water with an electric energy consumption SEC lower than 0.5 kWh*m^-3. The additional benefit of the DPD system is its modularity. The presented DPD system stands as a module, that can be multiplied as needed to achieve the desired size of the desalination plant.

Desalination↗

CFD Simulation of the Dosing Behavior within the Atomic Layer Deposition Feeding System

The effective operation of atomic layer deposition (ALD) feeding system is the premise of realizing specific ALD processes. In the present work, a detailed computational fluid dynamics (CFD) model of the feeding system has been developed and validated, which accounts for the roles of ALD valves and manifolds. A numerical simulation of the compressible fluid flow and heat/mass transfer within the feeding system was conducted. The dosing amounts and the spatiotemporal distributions of the precursors can be accurately predicted using the CFD model, as validated by experimental results. Different precursors, operating conditions, and structures of the feeding system were simulated and analyzed to examine the operating flexibility of the feeding system. The simulation results can be adopted as the upstream boundary conditions for simulations of the ALD process in the reaction chamber. The substrate-scale simulation indicates that the effect of the feeding system on the film deposition is highly related to the surface kinetics of ALD. The present work can serve as a guide for the development and optimization of different ALD-based processes via proper operation and even the design of the feeding system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of a High-Assay Low-Enriched Uranium Tri-Structural Isotropic Critical Experiment for Advanced Reactor Validation

High-assay low-enriched uranium (HALEU) fuel is a key component of many small modular reactor designs. Critical experiments are an important way to understand the neutronic performance of systems by obtaining nuclear data validations through measurements. Data reduce uncertainty and risk by showing that systems respond as predicted to changes such as temperature, subsequently advancing the overall technology readiness level of the materials within. Numerous critical experiments have been performed at the National Criticality Experiments Research Center (NCERC) operated by Los Alamos National Laboratory at the Nevada National Security Site since it became operational in 2011. However, the first experiment with HALEU fuel did not occur until 2024. Through extensive engineering, the experiment described in this paper was successfully designed and executed for the Comet vertical lift assembly at NCERC to perform measurements with HALEU tri-structural isotropic fuel that will assist in validation of nuclear data and computational modeling of small modular reactors for years to come.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Adaptively Learned Modeling for a Digital Twin of Hydropower Turbines with Application to a Pilot Testing System

In the development of a digital twin (DT) for hydropower turbines, dynamic modeling of the system (e.g., penstock, turbine, speed control) is crucial, along with all the necessary data interface, virtualization, and dashboard designs. Since the DT must mimic the actual dynamics of the hydropower turbine accurately, adaptive learning is required to train these dynamic models online so that the models in the DT can effectively follow the representation of the actual hydropower turbine dynamics accurately and reliably. This study presents an adaptive learning method for obtaining the hydropower turbine models for DT development of hydropower systems using the recursive least squares algorithm. To simplify the formulation, the hydropower turbine under consideration was assumed to operate near a fixed operating point, where the system dynamics can be well represented by a set of linear differential equations with constant parameters. In this context, the well-known six-coefficient model for the Francis turbine was formulated as the starting point to obtain input and output models for the turbine. Then, an adaptive learning mechanism was developed to learn model parameters using real-time data from a hydropower turbine testing system. This led to semi-physical modeling, in which first principles and data-driven modeling are integrated to produce dynamic models for DT development. Applications to a pilot system at the Norwegian University of Science and Technology (NTNU) were made, and the models learned adaptively using the data collected from the university’s pilot system. Desired modeling and validation results were obtained.

13 HYDRO ENERGY↗

Measuring Transverse Displacements Using Unmanned Aerial Systems Laser Doppler Vibrometer (UAS-LDV): Development and Field Validation

Measurement of bridge displacements is important for ensuring the safe operation of railway bridges. Traditionally, contact sensors such as Linear Variable Displacement Transducers (LVDT) and accelerometers have been used to measure the displacement of the railway bridges. However, these sensors need significant effort in installation and maintenance. Therefore, railroad management agencies are interested in new means to measure bridge displacements. This research focuses on mounting Laser Doppler Vibrometer (LDV) on an Unmanned Aerial System (UAS) to enable contact-free transverse dynamic displacement of railroad bridges. Researchers conducted three field tests by flying the Unmanned Aerial Systems Laser Doppler Vibrometer (UAS-LDV) 1.5 m away from the ground and measured the displacement of a moving target at various distances. The accuracy of the UAS-LDV measurements was compared to the Linear Variable Differential Transducer (LVDT) measurements. The results of the three field tests showed that the proposed system could measure non-contact, reference-free dynamic displacement with an average peak and root mean square (RMS) error for the three experiments of 10% and 8% compared to LVDT, respectively. Such errors are acceptable for field measurements in railroads, as the interest prior to bridge monitoring implementation of a new approach is to demonstrate similar success for different flights, as reported in the three results. This study also identified barriers for industrial adoption of this technology and proposed operational development practices for both technical and cost-effective implementation.

42 ENGINEERING↗

Resilience Evaluation and Enhancement for Island City Integrated Energy Systems

Extreme natural hazards, such as hurricanes or earthquakes, have a high probability of threatening energy supply security and causing high-order contingencies to island city-integrated energy systems (IC-IESs). To better evaluate and enhance resilience, a novel approach is proposed in this work for IC-IESs. The resilience of an IC-IES is analyzed from both the system level and the component level. At the system level, the impacts of extreme natural disasters are quantified. At the component level, the importance of individual components is analyzed through pre-failure and post-failure indices. The pre-failure index identifies the system’s weak links before an energy interruption, and the post-failure index determines the optimal repair strategy to restore the service. The proposed indices are solved by the impact increment method (IIM), which significantly improves computational efficiency without much affecting result accuracy. Numerical simulation studies are conducted on the modified Barry Island IES and IES E123-G48-H32 test systems. Furthermore, the results validate the effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An experimental system and procedure of unsteady-state relative permeability test for gas hydrate-bearing sediments

Reliable estimations of the relative permeability of gas and water in hydrate-bearing sediments (HBS) and the dependency of the relative permeability on hydrate saturation are critical to predict the productivity of a hydrate reservoir. Yet, this remains poorly estimated owing to lack of experimental data associated with difficulties in conducting multiphase flow experiments in HBS. Recognizing the experimental challenges, this study intends to develop and validate a new experimental system and procedure of unsteady-state relative permeability test that can generate reliable and reproducible flow measurements in HBS. Furthermore, gas hydrate is considered as a part of solid matrix in the sediment, so one of the challenges is to maintain a constant hydrate saturation, which is achieved in this experimental study using tight pressure-temperature (P-T) control near the hydrate stability boundary. The measured differential pressure across the specimen, methane injection flow rate, and volume of displaced brine are used to calculate the relative permeability by adopting a conventional Buckley-Leverett theory-based interpretation method. Residual brine saturation calculated for the hydrate-bearing specimen is higher than that of hydrate-free specimen, presumably due to decrease in pore size, increase in heterogeneity of solid matrix, and increase in size distribution of solid matrix and pore in the presence of hydrates. Further studies are necessary to represent the results of the unsteady-state flow experiment in HBS with a gas hydrate-dependent relative permeability model.

03 NATURAL GAS↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗

Leveraging PHIL for Inverter Functionality Requirement Evaluation to Ensure a Reliable Grid

This presentation showcases NREL's ongoing research on advanced Multi-point Power Hardware-in-the-Loop (PHIL) systems, enabling comprehensive evaluation of interoperability, stability, and wide-area stability in complex power grids. Key features include high-power PHIL capabilities, seamless PHIL Interfaces for effortless Grid-Following (GFL) and Grid-Forming (GFM) mode switching, and advanced multi-domain PHIL/Controller Hardware-in-the-Loop (CHIL) capabilities for evaluating diverse technology mixes, facilitating rigorous testing and validation of emerging power systems for reliable integration, enhanced resilience, and optimal performance.

lab capabilities↗

Multiphysics Modeling of Hydrokinetic Turbine Energy Conversion System

Hydrokinetic turbines (HKTs) hold great promise as a renewable energy source, but high maintenance costs and limited energy output hinder their widespread adoption. The lack of comprehensive research on HKT drivetrain designs creates a knowledge gap in enhancing generation efficiency and cost reduction. A model of the HKT system with a focus on electric drivetrains and power converters is required to address this knowledge gap. This paper first introduces a MATLAB-averaged model integrating electrical-mechanical-thermal domains and aging behaviors within multi-time frames. Then a PLECS model, which incorporates maximum power point tracking and dq reference framed control for AC-DC-AC power converters, is enriched by a dynamic thermal model to predict fast transients accurately. These models optimize the design at the component level, resulting in improved integrated system performance. Furthermore, the validation of the models is carried out through hardware experiments for the averaged model and hardware-in-the-loop testing for the dynamic model.

ADVANCED PROPULSION SYSTEMS,HYDRO ENERGY↗

Spatio-Temporal Deep Graph Network for Event Detection, Localization, and Classification in Cyber-Physical Electric Distribution System

This work proposes a deep graph learning framework to identify, locate, and classify power, cyber, and cyber power events at the distribution system level. The proposed algorithm jointly exploits spatial, temporal, and node-level cyber and physical data features. The developed graph neural network, together with a deep autoencoder, utilizes physical measurements from distribution level phasor measurement units and cyber data from communication network logs. The spatial structure of the synchrophasor measurements and network is incorporated through a weighted adjacency matrix. The temporal structure is incorporated by defining a spatial operation in the gated recurrent unit. This spatio-temporal learning element resides inside a power event detection, localization, and classification module that provides the degree of confidence for an event label. To accurately pinpoint the location of an event to the nearest bus equipped with a measurement unit, a combination of squared error and proximity score is utilized. Also included is a cyber event detection module that employs heteroskedasticity to analyze the significance of various cyber features during different types of attacks. Finally, a dual-bit cyber-power decision table determines the nature of the event. The proposed method is validated on two distribution systems modeled in OPAL-RT/Hypersim with limited phasor measurement units for different possible physical and cyber events. Further analyses include comparison with other state-of-the-art methods and validation in the presence of measurement noise. As a result, our method outperforms existing approaches and achieves an average detection accuracy of 97.97%, F1-score of 96.88%, precision of 96.53%, and recall of 98.57%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Relaxed PV Bus Model in Linear Power Flow

The emerging multimodal active energy resource units make it necessary to introduce constant voltage amplitude buses (PV bus) in the operation of modern distribution systems. To enable the analysis of PV bus using linear power flow models, this letter proposes a relaxed PV bus model for solving power flow related problems using an indirect modeling approach. The developed PV bus model can be applied to linear power flow models in both rectangular and polar coordinates. Besides, the approximation error of the relaxed PV bus model can also be controlled and quantified. Lastly, the proposed relaxed PV bus model is validated using different test systems. According to the numerical studies, the maximum error on the PV bus approximation in all case studies is only 0.61%, and the maximum error of the supporting power at the PV buses is 6.5%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Realization of Yang–Baxter Gate on Quantum Computers

Quantum computers provide a promising method to study the dynamics of many-body systems beyond classical simulation. On the other hand, the analytical methods developed and results obtained from the integrable systems provide deep insights on the many-body system. Quantum simulation of the integrable system not only provides a valid benchmark for quantum computers but is also the first step in studying integrable-breaking systems. The building block for the simulation of an integrable system is the Yang–Baxter gate. It is vital to know how to optimally realize the Yang–Baxter gates on quantum computers. Based on the geometric picture of the Yang–Baxter gates, the optimal realizations of two types of Yang–Baxter gates with a minimal number of controlled NOT (CNOT) or gates are presented. It is also shown how to systematically realize the Yang–Baxter gates via the pulse control. The different realizations on IBM quantum computers are tested and compared. It is found that the pulse realizations of the Yang–Baxter gates always have a higher gate fidelity compared to the optimal CNOT or realizations. On the basis of the above optimal realizations, the simulation of the Yang–Baxter equation on quantum computers is demonstrated. Finally, these results provide a guideline and standard for further experimental studies based on the Yang–Baxter gate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of Dynamical System Scaling to RAVEN and Facility Application

As part of the design optimization and model validation effort within the hybrid energy systems program, the research to implement dynamical system scaling (DSS) code to RAVEN is funded under the Integrated Energy System program in collaboration with the Digital Reactor Technology & Development department. The DSS data processing algorithm has been coded within the RAVEN framework along with other metrics and postprocessing models. The implemented code was tested using a gravity-driven draining tank draining case modeled in RELAP5-3D and generated data was successfully postprocessed based on the scaling analyses defined by DSS. Postprocessed data concluded less agreement for the tank exit velocity and indicated that the modeled input deck for RELAP5-3D requires modification to enforce minimal pressure differential effects to the draining process.

97 MATHEMATICS AND COMPUTING↗

Validation of Maui PSCAD Model: Motivation, Methodology, and Lessons Learned: Preprint

As power systems become increasingly dependent on inverter-based resources, the dominant physical and control interactions that determine system stability may no longer be accurately captured in positive sequence dynamic simulation tools; electromagnetic transient (EMT) simulations may be needed. This paper describes the process of creating and validating an EMT model of the entire Maui island transmission system in PSCAD software. The model is validated against the utility's PSSE model and against field data for an event that consisted of a single-phase fault followed by a generation trip. The methodology and lessons learned are summarized here.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Successful International Validation Test Shipment of the PIP-II HB650 Cryomodule Transportation System

The PIP-II Project will receive fully assembled cryomodules from CEA and STFC-UKRI as in-kind contributions. Damage to these cryomodules during transport is understood to be a significant risk to the project, so an extensive testing and validation program has been executed to mitigate this risk. The centerpiece of this effort was the successful shipment, from FNAL to STFC-UKRI and back, of a prototype HB650 cryomodule with cold testing before and after shipment to verify no functionality changes from shipment. Building on an escalating test transport program, the prototype cryomodule was shipped to the UK and back using realistic logistics, handling, instrumentation, and planning. The process of executing this shipment, lessons learned, and plan moving forward will be presented here.

43 PARTICLE ACCELERATORS↗