Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system strength”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Evidence for Electronically Driven Ferroelectricity in a Strongly Correlated Dimerized BEDT-TTF Molecular Conductor

By applying measurements of the dielectric constants and relative length changes to the dimerized molecular conductor kappa-(BEDT-TTF)(2)Hg(SCN)(2)Cl, we provide evidence for order-disorder type electronic ferroelectricity that is driven by the charge order within the (BEDT-TTF)(2) dimers and stabilized by a coupling to the anions. According to our density functional theory calculations, this material is characterized by a moderate strength of dimerization. This system thus bridges the gap between strongly dimerized materials, often approximated as (imer-Mott systems at 1/2 filling, and nondimerized or weakly dimerized systems at 1/4 filling, exhibiting a charge order. Our results indicate that intradimer charge degrees of freedom are of particular importance in correlated kappa-(BEDT-TTF)(2)X salts and can create novel states, such as electronically driven multiferroicity or charge-order-induced quasi-one-dimensional spin liquids.

Gati, Elena↗

Atom Interferometry with Floquet Atom Optics

Floquet engineering offers a compelling approach for designing the time evolution of periodically driven systems. We implement a periodic atom-light coupling to realize Floquet atom optics on the strontium 1 S 0 - 3 P 1 transition. These atom optics reach pulse efficiencies above 99.4% over a wide range of frequency offsets between light and atomic resonance, even under strong driving where this detuning is on the order of the Rabi frequency. Moreover, we use Floquet atom optics to compensate for differential Doppler shifts in large momentum transfer atom interferometers and achieve state-of-the-art momentum separation in excess of 400 ℏ⁢k. In conclusion, this technique can be applied to any two-level system at arbitrary coupling strength, with broad application in coherent quantum control.

74 ATOMIC AND MOLECULAR PHYSICS↗

Crystal plasticity finite element simulation of lattice rotation and x-ray diffraction during laser shock compression of tantalum

Here we present a crystal plasticity model tailored for high-pressure, high-strain-rate conditions that uses a multiscale treatment of dislocation-based slip kinetics. We use this model to analyze the pronounced plasticity-induced lattice rotations observed in shock-compressed polycrystalline tantalum via in situ x-ray diffraction. By making direct comparisons between experimentally measured and simulated texture evolution, we can explain how the details of the underlying slip kinetics control the degree of lattice rotation that ensues. Specifically, we show that only the highly nonlinear kinetics caused by dislocation nucleation can explain the magnitude of the rotation observed under shock compression. We demonstrate a good fit between our crystal plasticity model and x-ray diffraction data and exploit the data to quantify the dislocation nucleation rates that are otherwise poorly constrained by experiment in the dynamic compression regime.

36 MATERIALS SCIENCE↗

Etching with electron beam-generated plasmas: Selectivity versus ion energy in silicon-based films

In the ideal case, plasma-enhanced atomic layer etching enables the ability to not only remove one monolayer of material but also leave adjacent layers undamaged. This dual mandate requires fine control over the flux of species to ensure efficacy, while maintaining an often arduously low ion energy. Electron beam-generated plasmas are well-suited for etching at low ion energies as they are generally characterized by highly charged particle densities (10 10 –10 11 cm –3 ) and low electron temperatures (<1.0 eV), which provide the ability to deliver a large flux of ions whose energies are <5 eV. Raising the ion energy with substrate biasing thus enables process control over an energy range that extends down to values commensurate with the bond strength of most material systems. In this work, we discuss silicon nitride etching using pulsed, electron beam-generated plasmas produced in argon-SF6 backgrounds. We pay particular attention to the etch rates and selectivity versus oxidized silicon nitride and polycrystalline silicon as a function of ion energy from a few eV up to 50 eV. Here, we find the blanket etch rate of Si 3 N 4 to be in the range of 1 A/s, with selectivities (versus SiO 2 and poly-Si) greater than 10:1 when ion energies are below 30 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comparison of postimplant dosimetry for {sup 103}Pd versus {sup 131}Cs seeds on a retrospective series of PBSI patients

Purpose: Permanent breast seed implantation (PBSI) is an accelerated partial breast irradiation technique performed using stranded {sup 103}Pd radioactive seeds (average energy of 21 keV, 16.97 day half-life). Since 2004, {sup 131}Cs brachytherapy sources have become clinically available. The {sup 131}Cs radionuclide has a higher energy (average energy of 30 keV) and a shorter half-life (9.7 days) than {sup 103}Pd. The purpose of this study was to determine whether or not there are dosimetric benefits to using {sup 131}Cs brachytherapy seeds for PBSI. Methods: The prescribed dose for PBSI using {sup 103}Pd is 90 Gy, which was adjusted for {sup 131}Cs implants to account for the shorter half-life. A retrospective cohort of 30 patients, who have already undergone a {sup 103}Pd implant, was used for this study. The treatments were planned using the Variseed treatment planning system. The air kerma strength of the {sup 131}Cs seeds was adjusted in all preimplantation treatment plans so that the V{sub 100} (the volume within the target that receives 100% or more of the prescribed dose) were equivalent at time of implantation. Two month follow-up CT scans were available for all 30 patients and each patient was reevaluated using {sup 131}Cs seeds. The postimplant dosimetric parameters were compared using a two tailed t-test. Results: The prescribed dose for {sup 131}Cs was calculated to be 77 Gy; this dose would have the same biological effect as a PBSI implant with {sup 103}Pd of 90 Gy. The activities of the {sup 131}Cs sources were adjusted to an average of 2.2 {+-} 0.8 U for {sup 131}Cs compared to 2.5 {+-} 1.1 U for {sup 103}Pd in order to get an equivalent V{sub 100} as the {sup 103}Pd preimplants. While the use of {sup 131}Cs significantly reduces the preimplant V{sub 200} (the volume within the target that receives 200% or more of the prescribed dose) compared to {sup 103}Pd by 13.5 {+-} 9.0%, the reduction observed on the 2 month postimplant plan was 12.4 {+-} 5.1% which accounted for seed motion, implantation inaccuracies and tissue changes. This translates into an absolute reduction of 4.1 cm{sup 3} of tissue receiving 200% of the dose. Conclusions: This analysis of 30 early stage breast cancer patients who underwent the PBSI procedure shows that there is a theoretical dosimetric advantage to using {sup 131}Cs. However, in a realistic implant that will have seed misplacements and tissue changes, the use of {sup 131}Cs may not result in any clinically significant benefit.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-147: Magnetic Field Dose Response Considerations for a Linac Monitor Chamber

Purpose: The impact of magnetic fields on the readings of a linac monitor chamber have not yet been investigated. Herein we examine the total dose response as well as any deviations in the beam parameters of flatness and symmetry when a Varian monitor chamber is irradiated within an applied magnetic field. This work has direct application to the development of Linac-MR systems worldwide. Methods: A Varian monitor chamber was modeled in the Monte Carlo code PENELOPE and irradiated in the presence of a magnetic field with a phase space generated from a model of a Linac-MR prototype system. The magnetic field strength was stepped from 0 to 3.0T in both parallel and perpendicular directions with respect to the normal surface of the phase space. Dose to each of the four regions in the monitor chamber were scored separately for every magnetic field adaptation to evaluate the effect of the magnetic field on flatness and symmetry. Results: When the magnetic field is perpendicular to the phase space normal we see a change in dose response with a maximal deviation (10–25% depending on the chamber region) near 0.75T. In the direction of electron deflection we expectedly see opposite responses in chamber regions leading to a measured asymmetry. With a magnetic field parallel to the phase space normal we see no measured asymmetries, however there is a monotonic rise in dose response leveling off at about +12% near 2.5T. Conclusion: Attention must be given to correct for the strength and direction of the magnetic field at the location of the linac monitor chamber in hybrid Linac-MR devices. Elsewise the dose sampled by these chambers may not represent the actual dose expected at isocentre; additionally there may be a need to correct for the symmetry of the beam recorded by the monitor chamber. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

Assessing state-of-the-art capabilities for probing the atmospheric boundary layer: The XPIA field campaign

To assess current capabilities for measuring flow within the atmospheric boundary layer, including within wind farms, the U.S. Dept. of Energy sponsored the eXperimental Planetary boundary layer Instrumentation Assessment (XPIA) campaign at the Boulder Atmospheric Observatory (BAO) in spring 2015. Herein, we summarize the XPIA field experiment, highlight novel measurement approaches, and quantify uncertainties associated with these measurement methods. Line-of-sight velocities measured by scanning lidars and radars exhibit close agreement with tower measurements, despite differences in measurement volumes. Virtual towers of wind measurements, from multiple lidars or radars, also agree well with tower and profiling lidar measurements. Estimates of winds over volumes from scanning lidars and radars are in close agreement, enabling assessment of spatial variability. Strengths of the radar systems used here include high scan rates, large domain coverage, and availability during most precipitation events, but they struggle at times to provide data during periods with limited atmospheric scatterers. In contrast, for the deployment geometry tested here, the lidars have slower scan rates and less range, but provide more data during non-precipitating atmospheric conditions. Microwave radiometers provide temperature profiles with approximately the same uncertainty as Radio-Acoustic Sounding Systems (RASS). Using a motion platform, we assess motion-compensation algorithms for lidars to be mounted on offshore platforms. As a result, we highlight cases for validation of mesoscale or large-eddy simulations, providing information on accessing the archived dataset. We conclude that modern remote sensing systems provide a generational improvement in observational capabilities, enabling resolution of fine-scale processes critical to understanding inhomogeneous boundary-layer flows.

17 WIND ENERGY↗

Shock compression modeling of metallic single crystals: comparison of finite difference, steady wave, and analytical solutions

Background: The shock response of metallic single crystals can be captured using a micro-mechanical description of the thermoelastic-viscoplastic material response; however, using a such a description within the context of traditional numerical methods may introduce a physical artifacts. Advantages and disadvantages of complex material descriptions, in particular the viscoplastic response, must be framed within approximations introduced by numerical methods. Methods: Three methods of modeling the shock response of metallic single crystals are summarized: finite difference simulations, steady wave simulations, and algebraic solutions of the Rankine-Hugoniot jump conditions. For the former two numerical techniques, a dislocation density based framework describes the rate- and temperature-dependent shear strength on each slip system. For the latter analytical technique, a simple (two-parameter) rate- and temperature-independent linear hardening description is necessarily invoked to enable simultaneous solution of the governing equations. For all models, the same nonlinear thermoelastic energy potential incorporating elastic constants of up to order 3 is applied. Results: Solutions are compared for plate impact of highly symmetric orientations (all three methods) and low symmetry orientations (numerical methods only) of aluminum single crystals shocked to 5 GPa (weak shock regime) and 25 GPa (overdriven regime). Conclusions: For weak shocks, results of the two numerical methods are very similar, regardless of crystallographic orientation. For strong shocks, artificial viscosity affects the finite difference solution, and effects of transverse waves for the lower symmetry orientations not captured by the steady wave method become important. The analytical solution, which can only be applied to highly symmetric orientations, provides reasonable accuracy with regards to prediction of most variables in the final shocked state but, by construction, does not provide insight into the shock structure afforded by the numerical methods.

36 MATERIALS SCIENCE↗

Progress on Design and Production of Oxide Dispersion–Strengthened Alumina-Forming Austenitic Alloys for Nuclear Applications

Alumina-forming austenitic (AFA) alloys are a promising class of nuclear materials due to their high-temperature oxidation/corrosion resistance and mechanical properties. Unfortunately, these alloys are limited in use for core material applications, specifically in their use as nuclear fuel cladding. Improving these alloys through a fine dispersion of oxide precipitates and thus increasing the effective irradiation sink strength of the alloy system may mitigate many of the degradation phenomena expected during alloy deployment (such as high-temperature helium embrittlement for lead-cooled fast reactor applications). This work package has started using a combination of conventional and advanced manufacturing approaches to the fabrication of oxide dispersion–strengthened (ODS) AFA materials. As such, this report summarizes progress to date in the fabrication of new compositions of these ODS AFA materials with a focus on reactor-specific design and a multifaceted manufacturing approach. Two different compositions of AFA gas-atomized powders were procured, and 200 g of each have been prepared using mechanical alloying with the expectation of high-temperature consolidation in Q1 of FY24. In addition, an approach to use reactive cover gases to promote additional precipitate formation has been developed for implementation in FY24 as a direct comparison with conventionally manufactured alloys.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sintered-reaction Bonded Silicon Nitride Densified by a Gas Pressure Sintering Process Effects of Rare Earth Oxide Sintering Additives

Reaction-bonded silicon nitrides containing rare-earth oxide sintering additives were densified by gas pressure sintering. The sintering behavior, microstructure and mechanical properties of the resultant specimens were analyzed. For that purpose, Lu2O3-SiO2 (US), La2O3-MgO (AM) and Y2O3-Al2O3 (YA) additive systems were selected. Among the tested compositions, densification of silicon nitride occurred at the lowest temperature when using the La2O3-MgO system. Since the Lu2O3-SiO2 system has the highest melting temperature, full densification could not be achieved after sintering at 1950oC. However, the system had a reasonably high bending strength of 527 MPa at 1200oC in air and a high fracture toughness of 9.2 MPa m1/2. The Y2O3-Al2O3 system had the highest room temperature bending strength of 1.2 GPa

36 MATERIALS SCIENCE↗

Solvent permits solid curing agents to be used at room temperatures

Solvent system dissolves the solid curing agents used with polyurethane resins in adhesive systems. The system developed yields bond strengths comparable to 100 percent solid formulations. The optimum solvent chosen was a 55.5 percent solution in anhydrous tetrahydrofuran.

St. Cyr, M. C.↗

Effects of 50,000 hours of thermal aging on graphite/epoxy and graphite/polyimide composites

Thermal effects on tensile strengths of advanced composite systems have been determined for exposure times of 100 to 50,000 hours (5.7 years). Exposures were conducted at both ambient and reduced pressures at two temperatures for each composite. At the completion of the various aging periods, specimens were removed from the specially constructed aging furnaces, visually examined, and tensile tested at elevated temperature. After tensile testing, many of the thermal aging specimens were examined using a scanning electron microscope. Results of these studies are presented, and the changes in properties and the degradation mechanisms during high-temperature aging are discussed and illustrated using metallographic techniques.

Kerr, J. R.↗

Thin-film reliability and engineering overview

The reliability and engineering technology base required for thin film solar energy conversions modules is discussed. The emphasis is on the integration of amorphous silicon cells into power modules. The effort is being coordinated with SERI's thin film cell research activities as part of DOE's Amorphous Silicon Program. Program concentration is on temperature humidity reliability research, glass breaking strength research, point defect system analysis, hot spot heating assessment, and electrical measurements technology.

Ross, R. G., Jr.↗

Standard test evaluation of graphite fiber/resin matrix composite materials for improved toughness

Programs sponsored by NASA with the commercial transport manufacturers to develop a technology data base are required to design and build composite wing and fuselage structures. To realize the full potential of composite structures in these strength critical designs, material systems having improved ductility and interlaminar toughness are being sought. To promote systematic evaluation of new materials, NASA and the commercial transport manufacturers have selected and standardized a set of five common tests. These tests evaluate open hole tension and compression performance, compression performance after impact at an energy level of 20 ft-lb, and resistance to delamination. Ten toughened resin matrix/graphite fiber composites were evaluated using this series of tests, and their performance is compared with a widely used composite system.

Chapman, Andrew J.↗

Radar investigation of asteroids and planetary satellites

The aim is to make radar reconnaissance of near-Earth asteroids, mainbelt ateroids, the Galilean satellites, the Martian satellites, and the largest Saturnian satellites, using the Arecibo 13-cm and the Goldstone 3.5-cm systems. Measurements of echo strength, polarization, and delay/Doppler distribution of echo power provide information about dimensions, spin vector, large-scale topography, cm-to-m-scale morphology, and surface bulk density. The observations also yield refined estimates of target orbital elements. Radar signatures were measured for 31 mainbelt asteroids and 16 near-Earth asteroids since this task began eight years ago. The dispersion in asteroid radar albedoes and circular polarization ratios is extreme, revealing huge differences in surface morphologies, bulk densities, and metal concentration. For the most part, correction between radar signature and VIS/IR class is not high. Many near-Earth asteroids have extremely irregular, nonconvex shapes, but some have polar silhouettes that appear only slightly noncircular. The signatures of 1627 Ivar, 1986 DA, and the approximately 180-km mainbelt asteroid 216 Kleopatra suggest bifurcated shapes. Observational milestones during 1987 and 1988 are noted.

Ostro, Steven J.↗

Cryogenic piping material selection for the Component Test Facility (CTF)

The anticipated high cost of the 8500 psi cryogenic and 15,000 psi gas piping systems used in the CTF at NASA's John C. Stennis Space Center led to the consideration of high-strength materials for these piping systems. Based on years of satisfactory service using austenitic stainless steels in cryogenic applications, particularly for hydrogen service, consideration was limited to the austenitic stainless steels. Attention was focused on alternatives to the 304/304L grades of stainless steel traditionally used in these applications. This paper discusses the various considerations that resulted in the decision to continue using 304/304L for the cryogenic piping and the selection of the nitrogen-strengthened 21Cr-6Ni-9Mn alloy (UNS S21903) for the high-pressure gas systems at the CTF.

St. Cyr, William W.↗