Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Single electron in a storage ring: a probe into the fundamental properties of synchrotron radiation and a powerful diagnostic tool

An experimental study of undulator radiation generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. Photons were detected with a single-photon avalanche diode (SPAD) at an average rate of 20 kHz, corresponding to one detection every few hundred revolutions. Events were continuously recorded by a picosecond event timer for as long as 5 minutes at a time. The collected data were used to directly test the predictions of classical Poisson photostatistics. The study was motivated in part by a previous observation of sub-Poissonian statistics in a similar experiment with synchrotron radiation. In addition, we show that the time series of recorded events can be used to study the synchrotron motion of a single electron, yielding dynamical parameters such as the phase jitter of the radiofrequency cavity and the dependence of the synchrotron period on amplitude. Research plans for further experiments are also discussed.

47 OTHER INSTRUMENTATION↗

Federated learning for 2D synchrotron x-ray diffractometry: a cross-institutional approach for phase quantification of Ti–6Al–4V alloy

High-energy Two dimensional (2D) synchrotron x-ray diffractometry provides important insights into the atomistic structure and phase evolution of materials, yet traditional analysis methods remain complex, knowledge-intensive, and computationally demanding. Deep-learning models offer a powerful alternative for automating their analysis. Institutions that hold these datasets may be unwilling to share their data due to privacy and security policies, as well as the challenges associated with large-scale data transfer. As a result, models trained on local datasets often perform well only on their own data but exhibit bias and poor generalization across different instruments or facilities. To overcome these limitations, we explore federated learning (FL) for 2D synchrotron diffractograms, enabling collaborative model training without exchanging raw data. In this study, 2D synchrotron diffractograms of Ti–6Al–4V alloy collected from two independent facilities are used to train convolutional neural networks for predicting the β-phase volume fraction. Experimental results show that federated global models significantly outperform locally trained models in terms of generalization and achieve accuracy comparable to centralized trained models. These findings demonstrate the potential of FL to enable secure, cross-institutional collaboration and enhance the scalability of deep-learning-based materials characterization.

36 MATERIALS SCIENCE↗

Constraining supersymmetric dark matter with synchrotron measurements

The annihilations of neutralino dark matter (or other dark matter candidate) generate, among other standard model states, electrons and positrons. These particles emit synchrotron photons as a result of their interaction with the galactic magnetic field. In this paper, we use the measurements of the Wilkinson Microwave Anisotropy Probe satellite to constrain the intensity of this synchrotron emission and, in turn, the annihilation cross section of the lightest neutralino. We find this constraint to be more stringent than that provided by any other current indirect detection channel. In particular, the neutralino annihilation cross section must be less than {approx_equal}3x10{sup -26} cm{sup 3}/s (1x10{sup 25} cm{sup 3}/s) for 100 GeV (500 GeV) neutralinos distributed with a Navarro-Frenk-White halo profile. For the conservative case of an entirely flat dark matter distribution within the inner 8 kiloparsecs of the Milky Way, the constraint is approximately a factor of 30 less stringent. Even in this conservative case, synchrotron measurements strongly constrain, for example, the possibility of wino or Higgsino neutralino dark matter produced nonthermally in the early universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Morphology of the Galactic dark matter synchrotron emission with self-consistent cosmic-ray diffusion models

A generic prediction in the paradigm of weakly interacting dark matter is the production of relativistic particles from dark matter pair annihilation in regions of high dark matter density. Ultrarelativistic electrons and positrons produced in the center of the Galaxy by dark matter annihilation should produce a diffuse synchrotron emission. While the spectral shape of the synchrotron dark matter haze depends on the particle model (and secondarily on the Galactic magnetic fields), the morphology of the haze depends primarily on (1) the dark matter density distribution, (2) the Galactic magnetic field morphology, and (3) the diffusion model for high-energy cosmic-ray leptons. Interestingly, an unidentified excess of microwave radiation with characteristics similar to those predicted by dark matter models has been claimed to exist near the Galactic center region in the data reported by the Wilkinson Microwave Anisotropy Probe (WMAP) satellite, and is dubbed the 'WMAP haze'. In this study, we carry out a self-consistent treatment of the variables enumerated above, enforcing constraints from the available data on cosmic rays, radio surveys, and diffuse gamma rays. We outline and make predictions for the general morphology and spectral features of a 'dark matter haze' and we compare them to the WMAP haze data. We also characterize and study the spectrum and spatial distribution of the inverse-Compton emission resulting from the same population of energetic electrons and positrons. We point out that the spectrum and morphology of the radio emission at different frequencies are powerful diagnostics to test whether a Galactic synchrotron haze indeed originates from dark matter annihilation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics-informed machine learning analysis for nanoscale grain mapping by synchrotron Laue microdiffraction

Understanding the grain morphology, orientation distribution and crystal structure of nanocrystals is essential for optimizing the mechanical and physical properties of functional materials. Synchrotron X-ray Laue microdiffraction is a powerful technique for characterizing crystal structures and orientation mapping using focused X-rays. However, when the grain sizes are smaller than the beam size, mixed peaks in the Laue pattern from neighboring grains limit the resolution of grain morphology mapping. We propose a physics-informed machine learning (PIML) approach that combines a convolutional neural network feature extractor with a physics-informed filtering algorithm to overcome the spatial resolution limits of X-rays, achieving nanoscale resolution for grain mapping. Our PIML method successfully resolves the grain size, orientation distribution and morphology of Au nanocrystals through synchrotron microdiffraction scans, showing good agreement with electron backscatter diffraction results. This PIML-assisted synchrotron microdiffraction analysis can be generalized to other diffraction-based probes, enabling the characterization of nanosized structures with micrometre-sized probes.

X-ray crystallography↗

Phase-contrast 3D tomography of HeLa cells grown in PLLA polymer electrospun scaffolds using synchrotron X-rays

Advanced imaging is useful for understanding the three-dimensional (3D) growth of cells. X-ray tomography serves as a powerful noninvasive, nondestructive technique that can fulfill these purposes by providing information about cell growth within 3D platforms. There are a limited number of studies taking advantage of synchrotron X-rays, which provides a large field of view and suitable resolution to image cells within specific biomaterials. In this study, X-ray synchrotron radiation microtomography at Diamond Light Source and advanced image processing were used to investigate cellular infiltration of HeLa cells within poly L-lactide (PLLA) scaffolds. This study demonstrates that synchrotron X-rays using phase contrast is a useful method to understand the 3D growth of cells in PLLA electrospun scaffolds. Two different fiber diameter (2 and 4 µm) scaffolds with different pore sizes, grown over 2, 5 and 8 days in vitro , were examined for infiltration and cell connectivity. After performing visualization by segmentation of the cells from the fibers, the results clearly show deeper cell growth and higher cellular interconnectivity in the 4 µm fiber diameter scaffold. Finally, this indicates the potential for using such 3D technology to study cell–scaffold interactions for future medical use.

3D culture↗

Serial millisecond crystallography of membrane and soluble protein microcrystals using synchrotron radiation

Crystal structure determination of biological macromolecules using the novel technique of serial femtosecond crystallography (SFX) is severely limited by the scarcity of X-ray free-electron laser (XFEL) sources. However, recent and future upgrades render microfocus beamlines at synchrotron-radiation sources suitable for room-temperature serial crystallography data collection also. Owing to the longer exposure times that are needed at synchrotrons, serial data collection is termed serial millisecond crystallography (SMX). As a result, the number of SMX experiments is growing rapidly, with a dozen experiments reported so far. Here, the first high-viscosity injector-based SMX experiments carried out at a US synchrotron source, the Advanced Photon Source (APS), are reported. Microcrystals (5–20 µm) of a wide variety of proteins, including lysozyme, thaumatin, phycocyanin, the human A 2A adenosine receptor (A 2A AR), the soluble fragment of the membrane lipoprotein Flpp3 and proteinase K, were screened. Crystals suspended in lipidic cubic phase (LCP) or a high-molecular-weight poly(ethylene oxide) (PEO; molecular weight 8 000 000) were delivered to the beam using a high-viscosity injector. In-house data-reduction (hit-finding) software developed at APS as well as the SFX data-reduction and analysis software suites Cheetah and CrystFEL enabled efficient on-site SMX data monitoring, reduction and processing. Complete data sets were collected for A 2A AR, phycocyanin, Flpp3, proteinase K and lysozyme, and the structures of A 2A AR, phycocyanin, proteinase K and lysozyme were determined at 3.2, 3.1, 2.65 and 2.05 Å resolution, respectively. The data demonstrate the feasibility of serial millisecond crystallography from 5–20 µm crystals using a high-viscosity injector at APS. The resolution of the crystal structures obtained in this study was dictated by the current flux density and crystal size, but upcoming developments in beamline optics and the planned APS-U upgrade will increase the intensity by two orders of magnitude. Furthermore, these developments will enable structure determination from smaller and/or weakly diffracting microcrystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-QI-21: Iodinated Contrast Agent Time Course In Human Brain Metastasis: A Study For Stereotactic Synchrotron Radiotherapy Clinical Trials

Purpose: Synchrotron stereotactic radiotherapy (SSRT) is an innovative treatment combining the selective accumulation of heavy elements in tumors with stereotactic irradiations using monochromatic medium energy x-rays from a synchrotron source. Phase I/II clinical trials on brain metastasis are underway using venous infusion of iodinated contrast agents. The radiation dose enhancement depends on the amount of iodine in the tumor and its time course. In the present study, the reproducibility of iodine concentrations between the CT planning scan day (Day 0) and the treatment day (Day 10) was assessed in order to predict dose errors. Methods: For each of days 0 and 10, three patients received a biphasic intravenous injection of iodinated contrast agent (40 ml, 4 ml/s, followed by 160 ml, 0.5 ml/s) in order to ensure stable intra-tumoral amounts of iodine during the treatment. Two volumetric CT scans (before and after iodine injection) and a multi-slice dynamic CT of the brain were performed using conventional radiotherapy CT (Day 0) or quantitative synchrotron radiation CT (Day 10). A 3D rigid registration was processed between images. The absolute and relative differences of absolute iodine concentrations and their corresponding dose errors were evaluated in the GTV and PTV used for treatment planning. Results: The differences in iodine concentrations remained within the standard deviation limits. The 3D absolute differences followed a normal distribution centered at zero mg/ml with a variance (∼1 mg/ml) which is related to the image noise. Conclusion: The results suggest that dose errors depend only on the image noise. This study shows that stable amounts of iodine are achievable in brain metastasis for SSRT treatment in a 10 days interval.

60 APPLIED LIFE SCIENCES↗

High resolution 3D imaging of synchrotron generated microbeams

Purpose: Microbeam radiation therapy (MRT) techniques are under investigation at synchrotrons worldwide. Favourable outcomes from animal and cell culture studies have proven the efficacy of MRT. The aim of MRT researchers currently is to progress to human clinical trials in the near future. The purpose of this study was to demonstrate the high resolution and 3D imaging of synchrotron generated microbeams in PRESAGE® dosimeters using laser fluorescence confocal microscopy. Methods: Water equivalent PRESAGE® dosimeters were fabricated and irradiated with microbeams on the Imaging and Medical Beamline at the Australian Synchrotron. Microbeam arrays comprised of microbeams 25–50 μm wide with 200 or 400 μm peak-to-peak spacing were delivered as single, cross-fire, multidirectional, and interspersed arrays. Imaging of the dosimeters was performed using a NIKON A1 laser fluorescence confocal microscope. Results: The spatial fractionation of the MRT beams was clearly visible in 2D and up to 9 mm in depth. Individual microbeams were easily resolved with the full width at half maximum of microbeams measured on images with resolutions of as low as 0.09 μm/pixel. Profiles obtained demonstrated the change of the peak-to-valley dose ratio for interspersed MRT microbeam arrays and subtle variations in the sample positioning by the sample stage goniometer were measured. Conclusions: Laser fluorescence confocal microscopy of MRT irradiated PRESAGE® dosimeters has been validated in this study as a high resolution imaging tool for the independent spatial and geometrical verification of MRT beam delivery.

60 APPLIED LIFE SCIENCES↗

Magnetic Dichroism in the Reflectivity of Linearly Polarized Synchrotron Radiation from a Ti(10 nm)/Gd{sub 0.23}Co{sub 0.77}(250 nm)/Ti(10 nm) Sample

The dichroic effect (“rotated” polarization) in the reflectivity from a magnetically ordered sample is experimentally studied at the station PHASE of the Kurchatov Synchrotron Radiation Source. The experiments are performed for the Gd{sub 0.23}Co{sub 0.77} film, which has a compensation temperature T{sub comp} ≈ 433 K, using linearly polarized radiation of the photon energy of 7930 eV (L{sub 2} absorption edge of gadolinium) at room temperature. The developed theory of reflectivity accounted for the magnetic contributions to the scattering amplitude predicts the appearance of a peak for the orthogonal (to the incident polarization) polarization of the reflected radiation near the critical angle of the total external reflection. The experiment reveals the significant difficulties because of the incomplete σ polarization of the synchrotron beam, the beam instability, and so on. Therefore, a rotated-polarization peak has been detected near the critical angle but at the limits of the measurement accuracy. In principle, our experimental technique could be an alternative to circular polarization experiments, which are widely used at synchrotrons to study magnetic ordering. However, as we have shown, it makes high demands of the radiation source parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methods for lipid nanostructure investigation at neutron and synchrotron sources

A lipid membrane is a main component of biological membranes. Contemporary bionanotechnologies use phospholipids and ceramides as basic components of drugs and cosmetic preparations. Phospholipids-based nanoparticles are used as drug carriers. Effective development of bionanotechnologies in Russia calls for creation of physical methods to diagnose the particle nanostructure which would be promising for application in pharmacology. Radiation with wavelengths of 1–10 Å is an adequate instrument for detecting the nanostructure of lipid bi- and monolayers. The review deals with methods that apply neutron scattering and synchrotron radiation for studying nanostructures of lipid membranes, phospholipid nanoparticles, and phospholipid monolayers on a water surface by techniques of diffraction, small-angle scattering, and reflectometry. The importance of the mutually complementary application of neutron and synchrotron radiation for solving urgent problems of membrane biophysics, microbiology, dermapharmacology, and bionanotechnologies is demonstrated by particular examples of studies of phospholipid membranes and ceramide-based membranes. The efficiency of development and application of new methods for solving urgent problems of biophysics is shown. The review is written on the basis of results obtained over the period of 1999–2010 at the Joint Institute for Nuclear Research (JINR) Laboratory of Neutron Physics in collaboration with the Pharmaceutical Departments of universities of France (Paris-Sud, Chatenay Malabry) and Germany (Martin Luther University, Halle). The experiments were performed at various European and Russian neutron and synchrotron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Injection and stability of high-intensity ion beams in synchrotrons with electron cooling

The electron cooling-stacking injection is one of the most widely used injection methods applied in forming high-intensity cooled ion beams in the synchrotrons. The maximum available ion intensity in the synchrotron is determined by the lifetime of ions and the cooling-stacking efficiency. The formation of cooled high-intensity beams is constrained by instability, leading to a strong reduction in the ion lifetime. The results of experimental investigations and simulations of the cooling-stacking injection and stability of high-intensity cooled ion beams in synchrotrons with electron cooling are discussed.

43 PARTICLE ACCELERATORS↗

Measurement and simulations of intensity-dependent effects in the Fermilab Booster Synchrotron

The Fermilab Booster is a nearly 40-year-old proton synchrotron, designed to accelerate injected protons from a kinetic energy of 400 MeV to 8 GeV for extraction into the Main Injector and ultimately the Tevatron. Currently the Booster is operated with a typical intensity of 4.5 x 10 12 particles per beam, roughly twice the value of its design, because of the requirement for high particle flux in various experiments. Its relatively low injection energy provides certain challenges in maintaining beam quality and stability under these increasing intensity demands. An understanding of the effects limiting this intensity could provide enhanced beam stability and reduced downtime due to particle losses and subsequent damage to the accelerator elements. Design of future accelerators can also benefit from a better understanding of intensity effects limiting injection dynamics. Chapter 1 provides a summary of accelerator research during the 20th century leading to the development of the modern synchrotron. Chapter 2 puts forth a working knowledge of the terminology and basic theory used in accelerator physics, and provides a brief description of the Fermilab Booster synchrotron. Synergia, a 3d space-charge modeling framework, is presented, along with some simulation benchmarks relevant to topics herein. Emittance, a commonly used quantity characterizing beam size and quality in a particular plane, is discussed in Chapter 3. Space-charge fields tend to couple the motion among the planes, leading to emittance exchange, and necessitating a simultaneous measurement to obtain a complete emittance description at higher intensities. A measurement is described and results are given. RMS beam emittances are shown to be in keeping with known Booster values at nominal intensities and emittance exchange is observed and accounted for. Unmeasurable correlation terms between the planes are quantified using Synergia, and shown to be at most an 8% effect. Results of studies on the coherent and incoherent shifts of transverse (betatron) frequencies with beam intensity at injection energies are presented. In Chapter 4 the coherent frequency shifts are shown to be due to dipole- and quadrupole-wakefield effects. The asymmetry of the Booster beam chamber through the magnets, as well as the presence of magnet laminations, are responsible for the magnitudes and for the opposing signs of the horizontal and vertical tune shifts caused by these wakefields. Chapter 5 details the procedures for obtaining a linear coherent-tune-shift intensity dependence, yielding -0.009/10 12 in the vertical plane and +0.001/10 12 in the horizontal plane. Data demonstrate a requirement of several hundred turns to accumulate to its maximal value. Two independent studies are compared, corroborating these results. In Chapter 6, a measure of the incoherent tune shift with intensity puts an upper limit on the magnitude of the direct space-charge effect in the Fermilab Booster. A prediction is made for the representative incoherent particle tune shift using a realistic Gaussian distribution, allowing for growth of the beam envelope with intensity, and found to be 0.004/10 12 . The tune-spread dependence obtained by quantification of the resonant stopband width from beam-extinction measurements was measured at 0.005/10 12 , similar to the predicted value. These will be shown to be one order of magnitude smaller than the space-charge term from the Laslett tune shift for a fixed-size, uniform beam.

43 PARTICLE ACCELERATORS↗

National Synchrotron Light Source (NSLS) 2009 Activity Report

2009 was an incredibly exciting year for light sources at Brookhaven. The National Synchrotron Light Source (NSLS) hosted more than 2,200 visiting researchers, who, along with the about 50 members of our scientific staff, produced a total of 957 publications - about 20 percent of which appeared in premier journals. Covering topics ranging from Alzheimer's disease detection to ethanol-powered fuel cells, a sampling of these findings can be found in this Activity Report. We've also seen the resurfacing of some of our long-time users hard work. I was very proud to hear that two of the three recipients of the 2009 Nobel Prize in Chemistry have ties to the NSLS. Venki Ramakrishnan, a former employee in Brookhaven's biology department and long-time user of the NSLS, now at Cambridge University, and Thomas A. Steitz of Yale University, also a long-time NSLS user, shared the prize with Ada E. Yonath of the Weizmann Institute of Science for their work on the structure and function of the ribosome. In the late 1990s, Ramakrishnan and Steitz used protein crystallography at the NSLS to gather atomic-level images of two ribosome subunits: 30S (Ramakrishnan) and 50S (Steitz). Both laureates solved the high-resolution structures for these subunits based on this data. After struggling with a rough budget for several years, we received excellent funding, and then some, this year. In addition to NSLS operations funding, we received 3 million USD in funds from the American Recovery and Reinvestment Act (ARRA). We used that additional money for two exciting projects: construction of a full-field x-ray microscope and acquisition of several advanced x-ray detectors. The x-ray microscope will be able to image objects with a targeted spatial resolution of 30 nanometers. This capability will be particularly important for new initiatives in energy research and will prepare our users for the projected 1-nanometer resolution benchmark at the National Synchrotron Light Source II (NSLS-II). The detectors project is expected to increase the throughput of several high-demand beamlines by an order of magnitude as well as enable new classes of experiments. In addition, a huge chunk of ARRA money - 150 million USD - was put toward accelerating the construction of NSLS-II, which is now taking shape across the street. Now physically much more than just a pile of dirt, NSLS-II was granted Critical Decision 3 status by the Department of Energy (DOE) early last year, giving the official go-ahead for construction. In July, construction began, marked by a groundbreaking ceremony that attracted elected officials, media, and DOE, Battelle, and Stony Brook University representatives from across the state and the country. As progress on NSLS-II continues, we're working with Stony Brook University to identify ways to capitalize on the facility's unique capabilities through the Joint Photon Sciences Institute (JPSI). Included in this effort is a series of workshops to encourage the development and application of the photon sciences with collaborative research between industries, universities, and national laboratories. We helped host three of these workshops this year, focusing on microelectronics, energy storage, and materials in next-generation energy systems. The conversation and ideas generated at these meetings has been fresh and valuable and we hope to use this model to organize research opportunities in other scientific fields. Also this year: Brookhaven was deemed the lead institution for one of DOE's 46 Energy Frontier Research Centers, focused on understanding the underlying nature of superconductivity in complex materials by using techniques at the NSLS and CFN; DOE awarded a 100,000 USD supplemental grant to our detector program to continue the development of a new generation of x-ray detectors that use germanium sensors, which, at high energies, are much more efficient than equivalent ones based on silicon; and funding for one of our largest consortia, Case Western Reserve University's Center for Synchrotron Biosciences (CSB), was renewed through the National Institutes of Health. The CSB, which operates five NSLS beamlines and serves more than 550 users, will receive a five-year, 4-million USD grant to continue to study the structure and dynamics of proteins and nucleic acids. Finally, construction of the new X9 beamline and endstation for small angle x-ray scattering (SAXS) and wide angle x-ray scattering (WAXS) was completed this year. By July, the beamline and endstation were commissioned and serving general users. This allowed for the relocation of the SAXS and WAXS experimental programs from beamline X21 to X9, providing much-needed beam time for the soft condensed matter physics, life sciences, and nanoscience communities.

30 DIRECT ENERGY CONVERSION↗

3 GeV Booster Synchrotron Conceptual Design Report

Synchrotron light cna be produced from a relativistic particle beam circulating in a storage ring at extremely high intensity and brilliance over a large spectral region reaching from the far infrared regime to hard x-rays. The particles, either electrons or positrons, radiate as they are deflected in the fields of the storage ring bending magnets or of magnets specially optimized for the production of synchrotron light. The synchrotron light being very intense and well collimated in the forward direction has become a major tool in a large variety of research fields in physics, chemistry, material science, biology, and medicine.

43 PARTICLE ACCELERATORS↗

Probing Stress States in Silicon Nanowires During Electrochemical Lithiation Using In Situ Synchrotron X-Ray Microdiffraction

Silicon is considered as a promising anode material for the next-generation lithium-ion battery (LIB) due to its high capacity at nanoscale. However, silicon expands up to 300% during lithiation, which induces high stresses and leads to fractures. To design silicon nanostructures that could minimize fracture, it is important to understand and characterize stress states in the silicon nanostructures during lithiation. Synchrotron X-ray microdiffraction has proven to be effective in revealing insights of mechanical stress and other mechanics considerations in small-scale crystalline structures used in many important technological applications, such as microelectronics, nanotechnology, and energy systems. In the present study, an in situ synchrotron X-ray microdiffraction experiment was conducted to elucidate the mechanical stress states during the first electrochemical cycle of lithiation in single-crystalline silicon nanowires (SiNWs) in an LIB test cell. Morphological changes in the SiNWs at different levels of lithiation were also studied using scanning electron microscope (SEM). It was found from SEM observation that lithiation commenced predominantly at the top surface of SiNWs followed by further progression toward the bottom of the SiNWs gradually. The hydrostatic stress of the crystalline core of the SiNWs at different levels of electrochemical lithiation was determined using the in situ synchrotron X-ray microdiffraction technique. We found that the crystalline core of the SiNWs became highly compressive (up to -325.5 MPa) once lithiation started. In conclusion, this finding helps unravel insights about mechanical stress states in the SiNWs during the electrochemical lithiation, which could potentially pave the path toward the fracture-free design of silicon nanostructure anode materials in the next-generation LIB.

25 ENERGY STORAGE↗

On the Origin of the Hard X-Ray Excess of High-Synchrotron-Peaked BL Lac Object Mrk 421

For the first time, Kataoka and Stawarz reported a clear detection of a hard X-ray excess, above ≳20 keV, in the high-synchrotron-peaked BL Lac object Mrk 421. We find that this feature may not be produced by the low-energy part of the same electron population that produced the Fermi/LAT γ-ray. Because of that, it is required that the power-law electron energy go down to γ{sub min}≈19, which predicts a very strong radio emission (radio flux larger than the observed), even considering the synchrotron self-absorption effect. We investigate the possibility of this excess being produced from the spine/layer jet structure, which has been clearly detected in Mrk 421. We find that (1) similar to one-zone modeling, the spine emissions provide good modeling of the broadband spectral energy distribution, except for the hard X-ray excess; and (2) the hard X-ray excess can be well represented by the synchrotron photons (from the layer) being inverse Compton scattered by the spine electrons.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron micro-X-ray fluorescence analysis of natural diamonds: First steps in identification of mineral inclusions in situ

Diamond inclusions are of particular research interest in mantle petrology and diamond exploration as they provide direct information about the chemical composition of upper and lower mantle and about the petrogenetic sources of diamonds in a given deposit. The objective of the present work is to develop semi-quantitative analytical tools for non-destructive in situ identification and characterization of mineral inclusions in diamonds using synchrotron micro-X-ray Fluorescence ({mu}SXRF) spectroscopy and micro-X-ray Absorption Near Edge Structure ({mu}XANES) spectroscopy at a focused spot size of 4 to 5 micrometers. The data were collected at the Pacific Northwest Consortium (PNC-CAT) 20-ID microprobe beamline at the Advanced Photon Source, located at the Argonne National Laboratory, and yielded the first high-resolution maps of Ti, Cr, Fe, Ni, Cu, and Zn for natural diamond grains, along with quantitative {mu}SXRF analysis of select chemical elements in exposed kimberlite indicator mineral grains. The distribution of diamond inclusions inside the natural diamond host, both visible and invisible using optical transmitted-light microscopy, can be mapped using synchrotron {mu}XRF analysis. Overall, the relative abundances of chemical elements determined by {mu}SXRF elemental analyses are broadly similar to their expected ratios in the mineral and therefore can be used to identify inclusions in diamonds in situ. Synchrotron {mu}XRF quantitative analysis provides accurate estimates of Cr contents of exposed polished minerals when calibrated using the concentration of Fe as a standard. Corresponding Cr K-edge {mu}XANES analyses on selected inclusions yield unique information regarding the formal oxidation state and local coordination of Cr.

43 PARTICLE ACCELERATORS↗