Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “surface topography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Fabrication of freeform potassium dihydrogen phosphate crystals by belt-on-wheel polishing for spatially tailored polarization control in high-power lasers

Large-aperture (>30 cm) optical components that provide spatially tailored control of the properties of a laser beam, such as phase, polarization, and amplitude, have been the focus of much research and development in recent years. Such optics can improve energy throughput and target implosion efficiency in high-power laser systems conducting inertial confinement fusion research. Here, a method is demonstrated for fabricating freeform surface topographies into the birefringent crystalline material, potassium dihydrogen phosphate (KDP). Belt-on-wheel polishing with an oil-based fluid, developed to mitigate the deliquescent properties of KDP, is used to deterministically polish a freeform topography into KDP, enabling the fabrication of a wave plate with spatially arbitrary retardance. Testing of the laser-induced damage threshold of belt-on-wheel polished KDP was conducted at a wavelength of 351 nm and a pulse duration of 1 ns. The results revealed that the polished surfaces are highly resistant to laser-induced damage, making them suitable for large-aperture, high-power laser applications.

Urban, Nathaniel D. [Univ. of Rochester, NY (Unite↗

Surface characterization of selected LDEF tray clamps

The surface characterization of chromic acid anodized 6061-T6 aluminum alloy tray clamps has shown differences in surface chemistry depending upon the position on the Long Duration Exposure Facility (LDEF). Water contact angle results showed no changes in wettability of the tray clamps. The overall surface topography of the control, trailing edge(E3) and leading edge(D9) samples was similar. The thickness of the aluminum oxide layer for all samples determined by Auger depth profiling was less than one micron. X-ray photoelectron spectroscopy (XPS) analysis of the tray clamps showed significant differences in the surface composition. Carbon and silicon containing compounds were the primary contaminants detected.

Cromer, T. F.↗

Complementary characterization techniques for identification of ferroelectric domains in KNbO{sub 3} single crystals

KNbO{sub 3} single crystals are often utilized for their piezoelectric and optical properties. In this study the domain configurations in as-grown single crystals were investigated using reflected light microscopy, scanning electron microscopy and atomic force microscopy. Using atomic force microscopy it was possible to image the distortion induced on the crystal surface by the domain walls and to quantify the predicted angle between (001){sub pc} planes across these walls for the cases of both 90 deg. domain walls and S walls. These features can also be imaged using the other two techniques. This direct measurement of surface distortion verifies the geometrical model of domain structures, and suggests that any possible strain energy considerations are minor in predicting the surface topography in the material after phase changes from the growth temperature.

36 MATERIALS SCIENCE↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with aspheric x-ray optics

High-accuracy surface metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate x-ray light with nanometer-scale wavelengths. The current and potential capabilities of x˗ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. Metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for fabrication of slightly curved x-ray optics. However, for even moderately curved aspherical x-ray mirrors the flat-reference calibration is not sufficiently accurate. For micro-stitching interferometry developed for surface measurements with curved x-ray mirrors, the tool aberration errors are known to be transferred into the optical surface topography of x-ray mirrors. Our approach to improving metrology is to thoroughly calibrate the measuring tool and apply the results of the calibration to deconvolution of the measured data. Here we explore the application of a recently developed technique for calibrating the instrument transfer function (ITF) of 3D optical surface profilers to metrology with significantly curved x-ray optics. The technique, based on test standards patterned with two-dimensional (2D) binary pseudo-random arrays (BPRAs), employs the unique properties of the BPRA patterns in the spatial frequency domain. The inherent 2D power spectral density of the pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field of view of an instrument. The high efficacy of the technique has been previously demonstrated in application to metrology with flat and slightly curved optics. Here, we concentrate on development of an efficient fabrication process for production of highly randomized (HR) BPRA test standards on flat and 500-mm spherical optical substrates. We also compare and discuss the results of the ITF calibration of an interferometric microscope when using the HR BPRA standards on flat and curved substrates.

Munechika, Keiko↗

Effect of unmodulated laser light on the nanostructure of a thin solid AD-1 azo dye film

Exposure to light uniform in intensity and polarisation causes marked changes in the surface topography of a thin (320 nm) nanostructured AD-1 low molecular weight azo dye film. Linearly polarised incoherent light with a wavelength of 470 nm and intensity of 1 mW cm{sup -2} produces numerous teardrop-shaped hillocks of the order of 200 nm in radius over most of the film surface. (letters)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anisotropic surface state in a topological semimetal candidate Ta 3 SiTe 6

Using high-resolution angle-resolved photoemission spectroscopy, we studied the surface state of Ta 3 SiTe 6 , a candidate of topological semimetal protected by nonsymmorphic symmetry. Through photon-energy dependent measurements, the surface state near the Fermi level was detected. By determining the band dispersions, we found that the surface state is topological trivial. Around the surface Brillouin zone center, the surface bands disperse linear-like, forming a band crossing (zero energy gap) point at about 0.2 eV below the Fermi level. In Ta 3 SiTe 6 's rectangular surface Brillouin zone, the surface bands only cross the Fermi level along one axis, forming two hole-like Fermi pockets near surface Brillouin zone boundaries. Although the observed surface state is not topological, we proposed that its anisotropic Fermi surface topography could be potentially useful for future applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using High Frequency Focused Water-Coupled Ultrasound for 3-D Surface Depression Profiling

Surface topography is an important variable in the performance of many industrial components and is normally measured with diamond-tip profilometry over a small area or using optical scattering methods for larger area measurement. A prior study was performed demonstrating that focused air-coupled ultrasound at 1 MHz was capable of profiling surfaces with 25 micron depth resolution and 400 micron lateral resolution over a 1.4 mm depth range. In this article, the question of whether higher-frequency focused water-coupled ultrasound can improve on these specifications is addressed. 10 and 25 MHz focused ultrasonic transducers were employed in the water-coupled mode. Time-of-flight images of the sample surface were acquired and converted to depth / surface profile images using the simple relation (d = V*t/2) between distance (d), time-of-flight (t), and the velocity of sound in water (V). Results are compared for the two frequencies used and with those from the 1 MHz air-coupled configuration.

Roth, Don J.↗

The NASA environmental models of Mars

NASA environmental models are discussed with particular attention given to the Mars Global Reference Atmospheric Model (Mars-GRAM) and the Mars Terrain simulator. The Mars-GRAM model takes into account seasonal, diurnal, and surface topography and dust storm effects upon the atmosphere. It is also capable of simulating appropriate random density perturbations along any trajectory path through the atmosphere. The Mars Terrain Simulator is a software program that builds pseudo-Martian terrains by layering the effects of geological processes upon one another. Output pictures of the constructed surfaces can be viewed from any vantage point under any illumination conditions. Attention is also given to the document 'Environment of Mars, 1988' in which scientific models of the Martian atmosphere and Martian surface are presented.

Kaplan, D. I.↗

Effects of laser energy fluence on the onset and growth of the Rayleigh-Taylor instabilities and its influence on the topography of the Fe thin film grown in pulsed laser deposition facility

The effect of laser energy fluence on the onset and growth of Rayleigh-Taylor (RT) instabilities in laser induced Fe plasma is investigated using time-resolved fast gated imaging. The snow plow and shock wave models are fitted to the experimental results and used to estimate the ablation parameters and the density of gas atoms that interact with the ablated species. It is observed that RT instability develops during the interface deceleration stage and grows for a considerable time for higher laser energy fluence. The effects of RT instabilities formation on the surface topography of the Fe thin films grown in pulsed laser deposition system are investigated (i) using different laser energy fluences for the same wavelength of laser radiation and (ii) using different laser wavelengths keeping the energy fluence fixed. It is concluded that the deposition achieved under turbulent condition leads to less smooth deposition surfaces with bigger sized particle agglomerates or network.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detection of a buried horizon with a high thermal diffusivity using thermal remote sensing

A field investigation using thermal remote sensing was performed to test the feasibility of detecting the surface topography of granite bedrock beneath a thin cover of alluvium. Imagery of a region of the Mojave Desert were taken with an airborne multispectral scanner with thermal spectral bandwidths of 10.4 and 12.5 microns an instantaneous field of view of 2.5 mrad. It is suggested that a buried high thermal diffusivity horizon measurably lowers the surface temperature of the overlying lower diffusivity material during the peak of the annual heating cycle.

Nash, David B.↗

The Mercury Laser Altimeter Instrument for the MESSENGER Mission

The Mercury Laser Altimeter (MLA) is one of the payload science instruments on the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) mission, which launched on 3 August 2004. The altimeter will measure the round trip time-of-flight of transmitted laser pulses reflected from the surface of the planet that, in combination with the spacecraft orbit position and pointing data, gives a high-precision measurement of surface topography referenced to Mercury's center of mass. The altimeter measurements will be used to determine the planet's forced librations by tracking the motion of large-scale topographic features as a function of time. MLA's laser pulse energy monitor and the echo pulse energy estimate will provide an active measurement of the surface reflectivity at 1064 nm. This paper describes the instrument design, prelaunch testing, calibration, and results of post-launch testing.

Cavanaugh, John F.↗

Mars Gravity and Topography Interpretations

New models of the topography of Mars and its gravity field from the Mars Global Surveyor mission are shedding new light on the structure of the planet and the state of isostatic compensation. Gravity field observations over the flat northern hemisphere plains show a number of anomalies at the 100 to 200 mGal level that have no apparent manifestation in the surface topography. We believe that these anomalies are probably the result of ancient impacts and represent regions of denser material buried beneath the outer depositional crust. Similar anomalies are also found in the region of the north polar ice cap even though a gravity anomaly resulting from the 3 km high icecap has not been uniquely identified. This leads us to speculate that the ice cap is largely compensated and is older than the timescale of isostatic compensation, about 10(exp 15) years.

Zuber, Maria T.↗

Detailed gravimetric geoid for the GEOS-C altimeter calibration area

The GEOS-C spacecraft scheduled for launch in late 1974 will carry a radar altimeter for the purpose of measuring sea surface topography. In order to calibrate and evaluate the performance of the altimeter system, ground truth data are required. In this respect a detailed gravimetric geoid has been computed for the GEOS-C altimeter calibration area in the Atlantic Ocean off the East Coast of the U.S. This geoid is based upon a combination of mean free air surface gravity anomalies and the Goddard Space Flight Center GEM-6 satellite-derived spherical harmonic coefficients. Surface gravity anomalies have been used to provide information on the short wave length undulations of the geoid while the satellite-derived coefficients have provided information on the long wave length components. As part of these analyses, GSFC, SAO and OSU satellite-derived gravity models were used in the computations. Although geoid heights based upon the various satellite models differed by as much as 30 meters in the Southern Hemisphere, the differences in this Atlantic Ocean area were less than 4 meters.

Marsh, J. G.↗

Ice sheet radar altimetry

The surface topography of the Greenland and Antarctic ice sheets between 72 degrees north and south was mapped using radar altimetry data from the U.S. Navy GEOSAT. The glaciological objectives of this activity were to study the dynamics of the ice flow, changes in the position of floating ice-shelf fronts, and ultimately to measure temporal changes in ice surface elevation indicative of ice sheet mass balance.

Zwally, J.↗

PEALD grown high-k ZrO{sub 2} thin films on SiC group IV compound semiconductor

The study of ZrO{sub 2} thin films on SiC group IV compound semiconductor has been studied as a high mobility substrates. The ZrO{sub 2} thin films were deposited using the Plasma Enhanced Atomic Layer Deposition System. The thickness of the thin films were measured using ellipsometer and found to be 5.47 nm. The deposited ZrO{sub 2} thin films were post deposition annealed in rapid thermal annealing chamber at temperature of 400°Ð¡. The atomic force microscopy and X-гау photoelectron spectroscopy has been carried out to study the surface topography, roughness and chemical composition of thin film, respectively.

36 MATERIALS SCIENCE↗

Prelaunch performance of the NASA altimeter for the TOPEX/POSEIDON project

Validation of in-orbit performance has demonstrated the ability of satellite radar altimetry to measure mesoscale absolute dynamic sea surface topography and to measure the variation in the general circulation on the largest spatial scales. Measurements of basin scale mean circulation, however, have been corrupted by system inaccuracies. The TOPEX/POSEIDON radar altimeter satellite applies recent advances in remote sensing instrumentation to reduce long wavelength measurement errors to dramatically lower levels. The TOPEX altimeter measures the range to the ocean surface with 2-cm precision and accuracy through the use of both Ku- and C-band radars, a high pulse repetition frequency, an agile tracker, and absolute internal height calibration. Dual pulse bandwidths for both frequencies make it possible to quickly acquire the surface and begin tracking after crossing the land/ocean boundary. This paper presents the altimeter requirements and the elements of the altimeter design that have resulted in meeting these requirements. Prelaunch test data, based on the use of a Radar Altimeter System Evaluator to simulate the backscatter from the ocean surface, are presented to demonstrate that the TOPEX altimeter will meet these requirements and provide the data necessary to the understanding of basin scale mean circulation.

Marth, Paul C.↗

SU-F-J-19: Robust Region-Of-Interest (ROI) for Consistent Registration On Deteriorated Surface Images

Purpose: For African-American patients receiving breast radiotherapy with a bolus, skin darkening can affect the surface visualization when using optical imaging for daily positioning and gating at deep-inspiration breath holds (DIBH). Our goal is to identify a region-of-interest (ROI) that is robust against deteriorating surface image quality due to skin darkening. Methods: We study four patients whose post-mastectomy surfaces are imaged daily with AlignRT (VisionRT, UK) for DIBH radiotherapy and whose surface image quality is degraded toward the end of treatment. To simulate the effects of skin darkening, surfaces from the first ten fractions of each patient are systematically degraded by 25–35%, 40–50% and 65–75% of the total area of the clinically used ROI-ipsilateral-chestwall. The degraded surfaces are registered to the reference surface in six degrees-of-freedom. To identify a robust ROI, three additional reference ROIs — ROI-chest+abdomen, ROI-bilateral-chest and ROI-extended-ipsilateral-chestwall are created and registered to the degraded surfaces. Differences in registration using these ROIs are compared to that using ROI-ipsilateral-chestwall. Results: For three patients, the deviations in the registrations to ROI-ipsilateral-chestwall are > 2.0, 3.1 and 7.9mm on average for 25–35%, 40–50% and 65–75% degraded surfaces, respectively. Rotational deviations reach 11.1° in pitch. For the last patient, registration is consistent to within 2.6mm even on the 65–75% degraded surfaces, possibly because the surface topography has more distinct features. For ROI-bilateral-chest and ROI-extended-ipsilateral-chest registrations deviate in a similar pattern. However, registration on ROI-chest+abdomen is robust to deteriorating image qualities to within 4.2mm for all four patients. Conclusion: Registration deviations using ROI-ipsilateral-chestwall can reach 9.8mm on the 40–50% degraded surfaces. Caution is required when using AlignRT for patients experiencing skin darkening since the accuracy of AlignRT registration deteriorates. To avoid this inaccuracy, we recommend use of ROI-chest+abdomen, on which registration is consistent within 4.2mm even for highly degraded surfaces.

60 APPLIED LIFE SCIENCES↗

Self-sensing cantilevers with integrated conductive coaxial tips for high-resolution electrical scanning probe metrology

The lateral resolution of many electrical scanning probe techniques is limited by the spatial extent of the electrostatic potential profiles produced by their probes. Conventional unshielded conductive atomic force microscopy probes produce broad potential profiles. Shielded probes could offer higher resolution and easier data interpretation in the study of nanostructures. Electrical scanning probe techniques require a method of locating structures of interest, often by mapping surface topography. As the samples studied with these techniques are often photosensitive, the typical laser measurement of cantilever deflection can excite the sample, causing undesirable changes electrical properties. In this work, we present the design, fabrication, and characterization of probes that integrate coaxial tips for spatially sharp potential profiles with piezoresistors for self-contained, electrical displacement sensing. With the apex 100 nm above the sample surface, the electrostatic potential profile produced by our coaxial tips is more than 2 times narrower than that of unshielded tips with no long tails. In a scan bandwidth of 1 Hz–10 kHz, our probes have a displacement resolution of 2.9 Å at 293 K and 79 Å at 2 K, where the low-temperature performance is limited by amplifier noise. We show scanning gate microscopy images of a quantum point contact obtained with our probes, highlighting the improvement to lateral resolution resulting from the coaxial tip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗