Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “storage rings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

2 Kelvin helium distribution system for the Electron Ion Collider’s 10 o’clock satellite refrigerator

The Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) will involve superfluid helium cooling of superconducting magnets and Superconducting Radio Frequency (SRF) cavities at several sites around the existing Relativistic Heavy Ion Collider (RHIC) accelerator tunnel. While the majority of the cooling power for these loads is provided by BNL’s central cryogenic plant, Jefferson Lab is designing satellite equipment which augments the central plant and enables 2 Kelvin operation. The 2 K cryogenic distribution system for the collider’s 10 o’clock location (Interaction Region 10 or IR10) includes all necessary interfaces to the IR10 Satellite Refrigerator, to the overall EIC cryogenic distribution system, and to 12 SRF cryomodules for the electron and hadron storage rings. In addition to providing the required cooling capacities in all operating modes, the IR10 2 K cryogenic distribution system also stabilizes the supply temperature and enables safe connection and disconnection of individual IR10 cryomodules. Moreover, the layout of the IR10 2 K cryogenic distribution system copes with challenging spatial constraints and adapts to the process configuration and routing of existing RHIC cryogenic distribution components which will be re-used for EIC. This paper gives a full overview of the IR10 satellite cryogenic distribution system design, and highlights some of the challenges encountered.

Laverdure, Nathaniel [Thomas Jefferson National Ac↗

Adiabatic Longitudinal Island Formation Due to Phase Modulation Using BLonD

The studies of adiabatic island generation through tracking near the quarter integer resonance and separately, through phase modulation was conducted using the accelerator code BLonD. Parameters from the Hadron Storage Ring (HSR) were used in the model. The demonstration of resonance island formation through phase modulation will help to understand this possible source of beam dilution during the store and further control of the bunch shaping. In this document, an algorithm to calculate the 5 th , 7 th , and N th order resonances is given, tracking results are presented, and the stable fixed point calculations with comparison to Poincaré contours are given.

43 PARTICLE ACCELERATORS↗

Searching for the Most Harmful Field Errors in the HSR IR Superconducting Magnets

In this project, we improve beam stability for the Electron-Ion Collider. Magnetic field errors can reduce beam stability, making it essential to identify the field errors that have the greatest impact on accelerator performance. However, this is particularly challenging because beam stability depends on the complex interactions of many magnetic field errors, resulting in a high-dimensional and nonlinear optimization problem. We determine which field errors are the most influential for the large physical aperture superconducting magnet B2PF, a critical magnet in the Interaction Region (IR) in the Hadron Storage Ring (HSR). We complete and analyze nearly 30,000 simulations on the Brookhaven National Laboratory Linux Cluster by varying 18 nonlinear magnetic field errors. We evaluate beam stability using the dynamic aperture and the tune diffusion. We identify the field errors that most strongly influence beam stability and establish quantitative field error tolerances that improve accelerator performance.

43 PARTICLE ACCELERATORS↗

Measuring the muon precession frequency in the E989 Fermilab g-2 experiment

Since more than 50 years the electron and muon anomalies, $a_e$ and $a_\mu$, defined in terms of the gyromagnetic factor $g_i$ for particle $i$ as $a_i=(g_i-2)/2$, have provided a deep insight into the quantum structure of elementary particles.They have been, and continue to be, a milestone for the development of the Standard Model of Particle Physics against which all new theories have to be compared.For almost 20 years, the experimental value of $a_\mu$ has shown a tantalizing discrepancy of more than $3 \sigma$ from the theoretical prediction making it mandatory for experimentalists to improve the current result, dominated by the E821 experiment at BNL\cite{BNL}. The Muon $g-2$ E989 experiment at Fermilab will use the same storage ring technique used at BNL, and previously in the CERN-III experiment, with the goal of decreasing by a factor of 4 the current error on $a_\mu$, which will allow for a finer comparison with the theoretical prediction. E989 started collecting data in winter 2018 accumulating, in the period April-July 2018 (Run1) almost twice the statistics of the previous experiment (before application of data quality cuts). In this document, the experiment will be briefly described, underlying the improvements which will allow to reduce the systematic error, and some preliminary result will be shown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron polarimetry at EIC

The Electron-Ion Collider will be the first collider to use both polarized electron beams and polarized protons and light ions . This will offer unique opportunities to study the structure of protons and nuclei and answer fundamental questions in QCD. The uncertainties on the polarization measurement translate directly into the uncertainties of final physics observables. Hence, a precise measurement of the hadron beam polarization and a good control of the uncertainties are critical for the success of the spin program at the EIC. The requirements for beam polarimetry are non-destructive with uncertainty less than 1%. At the Electron Storage Ring (ESR) and the Rapid Cycling Synchrotron (RCS), the electron beam polarization will be measured using wellestablished Compton polarimetry techniques. However, the EIC Compton polarimeter will face unique challenges, demanding further developments. A Mott polarimeter will also be employed at the source for initial polarization measurements. Both longitudinal and transverse polarization will be measured, with the capability to monitor polarization on a bunch-by-bunch basis. Achieving these precise measurements will be critical to controlling systematic uncertainties and ensuring the overall success of the EIC’s physics objectives.

Zhang, Zhengqiao (ORCID:0009000742521735)↗

Measurement of the anomalous spin precession frequency $\omega_\alpha$ in the Muon g-2 experiment at Fermilab

The Muon $g-2$ Experiment at Fermilab aims to measure the muon magnetic moment anomaly, $a_{\mu} = (g-2)/2$, with a final accuracy of 0.14 parts per million (ppm). A $3.1$-GeV muon beam is injected into a storage ring of $14\,$m diameter, in the presence of a $1.45\,$T magnetic field. The anomaly $a_\mu$ can be extracted by accurately measuring the anomalous muon spin precession frequency $\omega_a$, based on the arrival time distribution of decay positrons observed by $24$ calorimeters, and the magnetic field. In 2023, the experiment published its second result based on the two datasets Run-2 and Run-3, reaching the unprecedented sensitivity of $0.21\,$ppm --- a factor $\sim2.2$ improvement since its first result published in 2021, based on the first dataset (Run-1). In this paper, we will focus on the measurement of the $\omega_a$ frequency, describing the techniques and major sources of systematic uncertainty in the 2023 publication, and outlining the improvements since the 2021 result. We will also cover the status of the ongoing $\omega_a$ analysis for the last three datasets, collected from 2020 to 2023, along with the projected uncertainties on the final Muon $g-2$ measurement at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Measurement of the Muon Spin Precession Frequency in the Fermilab Muon g-2 Experiment

The Fermilab Muon $g-2$ Experiment is designed to measure the muon's anomalous magnetic moment, $ a_\mu = (g-2)/2 $ with an accuracy of 140 parts per billion. This quantity is determined from two key measurements; the difference between the muon's spin precession frequency and its cyclotron frequency, given by $\omega_a = \omega_s - \omega_c$, and $\tilde{\omega_p^\prime}$, proportional to the muon-weighted magnetic field.In this talk, we focus on presenting the methodology for determining $\omega_a$. Muons with a momentum of 3.1 GeV are injected into a storage ring, and $\omega_a$ is extracted from the time distribution of decay positrons recorded by 24 electromagnetic calorimeters placed symmetrically inwards around the ring. We present the final result from the muon g-2 collaboration and analysis techniques based on data collected from 2020 to 2023.

Zaid, Estifa'a [Liverpool U.]↗

VeryFastCCD: a high frame rate soft X-ray detector

Direct X-ray detection in silicon has been transformative for scattering experiments in biology and materials science. While bump-bonded hybrid pixels have been attractive for hard X-ray detection, the challenge for single photon soft X-ray detection is sufficiently low noise. CCD structures on thick, high-resistivity silicon have been successfully used as sensors over the range of soft to hard X-rays at storage rings and FELs. The VeryFastCCD is a high frame rate, column-parallel CCD sensor with 48 μm pixels. Combined with 256-channel custom readout ASICs, frame rates of 5–10 kHz have been achieved with readout noise as low as 20 e and full-well capacity >4 × 10 5 e/pixel. Thin (10 nm and 100 nm) entrance window contact processes have also been developed which provide >85% quantum efficiency for 285 eV X-rays. Systems are currently being developed for several beamlines at the upgraded Advanced Light Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Proton EDM Experiment (pEDM)

The Proton EDM Experiment (pEDM) is the first direct search for the proton electric dipole moment (EDM) with the aim of being the first experiment to probe the Standard Model (SM) prediction of any particle EDM. Phase-I of pEDM will achieve $10^{-29} e\cdot$cm, improving current indirect limits by four orders of magnitude. This will establish a new standard of precision in nucleon EDM searches and offer a unique sensitivity to better understand the Strong CP problem. The experiment is ideally positioned to explore physics beyond the Standard Model (BSM), with sensitivity to axionic dark matter via the signal of an oscillating proton EDM and across a wide mass range of BSM models from $\mathcal{O}(1\text{GeV})$ to $\mathcal{O}(10^3\text{TeV})$. Utilizing the frozen-spin technique in a highly symmetric storage ring that leverages existing infrastructure at Brookhaven National Laboratory (BNL), pEDM builds upon the technological foundation and experimental expertise of the highly successful Muon $g$$-$$2$ Experiments. With significant R&D and prototyping already underway, pEDM is preparing a conceptual design report (CDR) to offer a cost-effective, high-impact path to discovering new sources of CP violation and advancing our understanding of fundamental physics. It will play a vital role in complementing the physics goals of the next-generation collider while simultaneously contributing to sustaining particle physics research and training early-career researchers during gaps between major collider operations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The optical properties of platinum and gold in the vacuum ultraviolet

The optical constants of platinum and gold thin films have been determined in the spectral region of 40 to 200 nm by reflection measurements. The highly polarized continuum of synchrotron radiation emitted by the 240-MeV electron storage ring at the Physical Sciences Laboratory of the University of Wisconsin was used as a light source for the spectrum below 120 nm, while a windowless discharge lamp coupled to a normal incidence monochromator provided a source for the longer wavelengths. Optical constants were determined by a computer program based on iterative solutions to the Fresnel equations for reflection as a function of the angle of incidence.

Linton, R. C.↗

An extreme ultraviolet photometer for solar observations from the Atmosphere Explorer satellites

A broadband photometer experiment is being fabricated for the Atmosphere Explorer C, D and E missions to record the solar irradiance in the 40 to 1250 A region with seven distinct passbands. The experiment consists principally of four spinal electron multipliers located behind a moving eight position filter wheel. Six metallic filters are used to spectrally isolate the solar irradiance. In addition three Al2O3 diodes, two with filters, are being used to record the solar irradiance over the range of orbital altitudes from perigee through apogee. A principal goal of the experiment will be to measure time dependence of the solar irradiance with respect to a storage ring synchrotron light source which has been calibrated in terms of the best currently available standards of irradiance.

Heath, D. F.↗

Feasibility of coherent X-ray production by X-ray pumping

It is suggested that coherent X-rays can be produced by inverting the electron population in a suitable target, such as Li, through irradiation with X-rays generated by fast electrons traversing an electromagnetic field (as in a storage ring). Conditions to be satisfied by target and radiation parameters are stated, and examples given.

Csonka, P. L.↗

Relative abundances of positrons and antiprotons in the primary cosmic ray flux

Observations on the ratio of positrons to the electron-positron sum made in the 5 to 50 GeV range by Buffington et al. (1974) are used to put an upper limit on the ratio of antiprotons to protons at various energies. The calculation of the latter ratio is based on detailed measurements of the cross section of antiproton production up to intersecting storage ring energies.

Badhwar, G. D.↗

Unfolding first and second order diffracted radiation when using synchrotron radiation sources - A technique

A technique is presented of using a single calibrated XUV detector for radiometric measurements of synchrotron radiation after the radiation passes through a monochromator that produces a mixture of first- and second-order diffracted radiation. Irradiance measurements are made with the synchrotron source operating at two different energies for the orbiting electrons. The known change in the spectral distribution produced by the electron energy change is used to calculate the flux in both first and second order. The dependence of the precision of these determinations on the two detected currents and on the detector calibration at both first- and second-order wavelengths is calculated. Experimental results using the National Bureau of Standards synchrotron (SURF-I) are presented, and anticipated results for the new NBS electron storage ring (SURF-II) are calculated.

Saloman, E. B.↗

Feasibility of coherent X-ray production by X-ray pumping

It is suggested that coherent soft X rays can be produced by inverting the electron population in a suitable target, such as Li, through irradiation with X rays generated by fast electrons traversing an electromagnetic field (as in a storage ring). Conditions to be satisfied by target and radiation parameters are stated, and examples given.

Csonka, P. L.↗

Measurements of selected psi /3684/ branching ratios from a study of secondary lepton pairs

The measurements considered were made at the electron-positron storage ring at the Stanford Linear Accelerator Center. The apparatus used consists of two identical spectrometers mounted in a collinear configuration about the beam-interaction region. The energies of secondary electrons or positrons are measured with good resolution in large NaI(Tl) total-absorption detectors. Data accumulated without gamma-ray converters were examined for electron-positron pairs. The data taken with gamma-ray converters in place and at center-of-mass energies within 1 MeV of the resonance energy were scanned for evidence of either charged particles or converted gamma rays accompanying the detected muon pairs.

Hilger, E.↗

Search for monenergetic gamma rays from psi /3684/ decay

Results are reported of a search for monoenergetic gamma rays with energies above 50 MeV arising from psi (3684) decay. The measurements were made by operating an electron-positron storage ring at a center-of-mass energy of 3684 MeV and detecting the secondary gamma rays with large-crystal NaI(T1) spectrometers. No significant evidence is found for the emission of such radiation, and upper limits are placed on such emissions for energies above 50 MeV.

Simpson, J. W.↗

A calibration of detectors and gratings between 100 and 600 Angstroms

Calibration and efficiency measurements of magnetic electron multipliers, diffraction gratings, and photocathodes over the wavelength range 100 to 600 A are reported. For some of the measurements it was found necessary to use the synchrotron radiation from a storage ring. Measurements of grating efficiencies, the polarization produced by diffraction gratings, and the photoelectric yields of various photocathodes are included.

Samson, J. A. R.↗