Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “storage resources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Advance Network Reservation and Provisioning for Science

We are witnessing a new era that offers new opportunities to conduct scientific research with the help of recent advancements in computational and storage technologies. Computational intensive science spans multiple scientific domains, such as particle physics, climate modeling, and bio-informatics simulations. These large-scale applications necessitate collaborators to access very large data sets resulting from simulations performed in geographically distributed institutions. Furthermore, often scientific experimental facilities generate massive data sets that need to be transferred to validate the simulation data in remote collaborating sites. A major component needed to support these needs is the communication infrastructure which enables high performance visualization, large volume data analysis, and also provides access to computational resources. In order to provide high-speed on-demand data access between collaborating institutions, national governments support next generation research networks such as Internet 2 and ESnet (Energy Sciences Network). Delivering network-as-a-service that provides predictable performance, efficient resource utilization and better coordination between compute and storage resources is highly desirable. In this paper, we study network provisioning and advanced bandwidth reservation in ESnet for on-demand high performance data transfers. We present a novel approach for path finding in time-dependent transport networks with bandwidth guarantees. We plan to improve the current ESnet advance network reservation system, OSCARS [3], by presenting to the clients, the possible reservation options and alternatives for earliest completion time and shortest transfer duration. The Energy Sciences Network (ESnet) provides high bandwidth connections between research laboratories and academic institutions for data sharing and video/voice communication. The ESnet On-Demand Secure Circuits and Advance Reservation System (OSCARS) establishes guaranteed bandwidth of secure virtual circuits at a certain time, for a certain bandwidth and length of time. Though OSCARS operates within the ESnet, it also supplies end-to-end provisioning between multiple autonomous network domains. OSCARS gets reservation requests through a standard web service interface, and conducts a Quality-of-service (QoS) path for bandwidth guarantees. Multi-protocol Label Switching (MPLS) and the Resource Reservation Protocol (RSVP) enable to create a virtual circuit using Label Switched Paths (LSP's). It contains three main components: a reservation manager, a bandwidth scheduler, and a path setup subsystem. The bandwidth scheduler needs to have information about the current and future states of the network topology in order to accomplish end-to-end bandwidth guaranteed paths.

97 MATHEMATICS AND COMPUTING↗

Intermountain West Energy Sustainability & Transitions Initiative: CO2 Transport and Geologic Storage Modeling Results

These resources provide the full set of cost modeling results and methods as part of the I-WEST Roadmap Initiative that were used to compile figures as part of the "Pathways to CO2 Utilization and Storage for the Intermountain West Region" chapter. The data were generated from a series of National Energy Technology Laboratory (NETL) cost models and relate to carbon dioxide (CO2) transport costs, CO2 enhanced oil recovery (CO2-EOR) economics, and saline storage economics. These models were used to analyze various business cases given changes in technical and financial assumptions for the I-WEST region as a means to explore how these assumptions influence CO2 transport and storage costs, as well as to evaluate the effect of changing oil prices on the viability of CO2-EOR and the mass of CO2 stored via CO2-EOR. The accompanying report titled "Intermountain West Energy Sustainability & Transitions Initiative: CO2 Transport and Geologic Storage Modeling Results" provides a detailed overview on the models, assumptions, and parameters used in the modeling, as well as example results..

CO2 EOR costs,CO2 Storage Costs,CO2 transportation↗

Wabash CarbonSAFE Roadmap for Network and Storage Deployment: Subtask 10.3 (Technical Report)

Wabash Valley Resources is incorporating carbon capture and storage (CCS) technologies into its hydrogen production plant in Terre Haute, Indiana, at an expected annual capture rate that will make Wabash Valley Resources one of the largest carbon capture facilities in the world. In addition to storing its own captured CO 2 , the geographic location and subsurface geology at Wabash Valley Resources suggest it may be an advantageous site for a carbon storage hub. This report analyzes the potential of nearby sources to transport their captured CO 2 to Wabash Valley Resources through an optimal pipeline network.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Seismic Tomography 2024

Seismic tomography is the most abundant source of information about the internal structure of the Earth at scales ranging from a few meters to thousands of kilometers. It constrains the properties of active volcanoes, earthquake fault zones, deep reservoirs and storage sites, glaciers and ice sheets, or the entire globe. It contributes to outstanding societal problems related to natural hazards, resource exploration, underground storage, and many more. The recent advances in seismic tomography are being translated to nondestructive testing, medical ultrasound, and helioseismology. Nearly 50 yr after its first successful applications, this article offers a snapshot of modern seismic tomography. Focused on major challenges and particularly promising research directions, it is intended to guide both Earth science professionals and early-career scientists. The individual contributions by the coauthors provide diverse perspectives on topics that may at first seem disconnected but are closely tied together by a few coherent threads: multiparameter inversion for properties related to dynamic processes, data quality, and geographic coverage, uncertainty quantification that is useful for geologic interpretation, new formulations of tomographic inverse problems that address concrete geologic questions more directly, and the presentation and quantitative comparison of tomographic models. Finally, it remains to be seen which of these problems will be considered solved, solved to some extent, or practically unsolvable over the next decade.

58 GEOSCIENCES↗

Fabrication, Modeling, and Testing of a Prototype Thermal Energy Storage Containment

Increasing penetration of variable renewable energy resources requires the deployment of energy storage at a range of durations. Long-duration energy storage (LDES) technologies will fulfill the need to firm variable renewable energy resource output year round; lithium-ion batteries are uneconomical at these durations. Thermal energy storage (TES) is one promising technology for LDES applications because of its siting flexibility and ease of scaling. Particle-based TES systems use low-cost solid particles that have higher temperature limits than the molten salts used in traditional concentrated solar power systems. A key component in particle-based TES systems is the containment silo for the high-temperature (>1100 degrees C) particles. This study combined experimental testing and computational modeling methods to design and characterize the performance of a particle containment silo for LDES applications. A laboratory-scale silo prototype was built and validated the congruent transient finite element analysis (FEA) model. The performance of a commercial-scale silo was then characterized using the validated model. The commercial-scale model predicted a storage efficiency above 95% after 5 days of storage with a design storage temperature of 1200 degrees C. Insulation material and concrete temperature limits were considered as well. The validation of the methodology means the FEA model can simulate a range of scenarios for future applications. This work supports the development of a promising LDES technology with implications for grid-scale electrical energy storage, but also for thermal energy storage for industrial process heating applications.

clean energy↗

Time to grapple with collateral issues of renewable standards

A number of states with aggressive renewable portfolio standards (RPS) are beginning to get a taste of what is likely to come as more renewable resources are added to the network. Three issues stand out: the need for more transmission capacity; the need for significant additional storage and/or balancing resources, often in the form of thermal peaking units; the costs of these requirements, plus the incremental cost of renewable resources, quickly add up. A study to examine the effect of California's 33 percent RPS mandate by 2020, for example, concludes that meeting the target will cost $8.9 billion in 2020 while saving some $6.3 billion in avoided costs, resulting in a net cost of $2.6 billion, all in 2008 dollars. To meet the target will require building eight major transmission lines and a significant amount of backup thermal generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Accuracy and Validation of Measured and Modeled Data for Distributed PV Interconnection and Control

The distribution grid is changing to become an active resource with complex modeling needs. The new active distribution grid will, within the next ten years, contain a complex mix of load, generation, storage and automated resources all operating with different objectives on different time scales from each other and requiring detailed analysis. Electrical analysis tools that are used to perform capacity and stability studies have been used for transmission system planning for many years. In these tools, the distribution grid was considered a load and its details and physical components were not modeled. The increase in measured data sources can be utilized for better modeling, but also control of distributed energy resources (DER). The utilization of these sources and advanced modeling tools will require data management, and knowledgeable users. Each of these measurement and modeling devices have accuracy constraints, which will ultimately define their future ability to be planned and controlled. This paper discusses the importance of measured data accuracy for inverter control, interconnection and planning tools and proposes ranges of control accuracy needed to satisfy all concerns based on the present grid infrastructure.

Stewart, Emma↗

Fabrication, Modeling, and Testing of a Prototype for Particle Thermal Energy Storage Containment

Increasing penetration of variable renewable energy resources requires the deployment of energy storage at a range of durations. Long-duration energy storage (LDES) technologies will fulfill the need to firm variable renewable energy resource output throughout the year. Conventional electrochemical batteries (e.g., lithium-ion) are uneconomical in this role due to high energy capacity costs. Thermal energy storage (TES) is one promising technology for LDES applications because of its siting flexibility and ease of scaling. Particle-based TES systems use low-cost solid particles that have higher temperature limits than the molten salts used in traditional concentrated solar power systems. A key component in particle-based TES systems is the containment silo for the high-temperature (> 1100 degrees C) particles. This study combined experimental testing and computational modeling methods to design and characterize the performance of a particle containment silo for LDES applications. A containment silo prototype was built at a laboratory scale and used to validate a congruent transient finite element analysis (FEA) model. The validation compared the actual and predicted temperature profile through the prototype over six days as the particles cooled from their initial temperature. The performance of a commercial scale (> 5 GWhth) was then characterized using the validated model. The transient FEA model was subject to several charge-discharge cycles to mimic a possible operating schedule. The commercial-scale model predicted a storage efficiency in excess of 95% after five days of storage with a design storage temperature of 1200 degrees C. Insulation material and concrete temperature limits were considered as well. The validation of the methodology means the FEA model can simulate a range of scenarios for future applications. This work supports the development of a promising LDES technology with implications for grid-scale electrical energy storage, but also for thermal energy storage for industrial process heating applications.

ENERGY STORAGE↗

Efficient spares matrix multiplication scheme for the CYBER 203

This work has been directed toward the development of an efficient algorithm for performing this computation on the CYBER-203. The desire to provide software which gives the user the choice between the often conflicting goals of minimizing central processing (CPU) time or storage requirements has led to a diagonal-based algorithm in which one of three types of storage is selected for each diagonal. For each storage type, an initialization sub-routine estimates the CPU and storage requirements based upon results from previously performed numerical experimentation. These requirements are adjusted by weights provided by the user which reflect the relative importance the user places on the resources. The three storage types employed were chosen to be efficient on the CYBER-203 for diagonals which are sparse, moderately sparse, or dense; however, for many densities, no diagonal type is most efficient with respect to both resource requirements. The user-supplied weights dictate the choice.

Lambiotte, J. J., Jr.↗

Data storage accounting and verification at LHC experiments

All major experiments at the Large Hadron Collider (LHC) need to measure real storage usage at the Grid sites. This information is equally important for resource management, planning, and operations. To verify the consistency of central catalogs, experiments are asking sites to provide a full list of the files they have on storage, including size, checksum, and other file attributes. Such storage dumps, provided at regular intervals, give a realistic view of the storage resource usage by the experiments. Regular monitoring of the space usage and data verification serve as additional internal checks of the system integrity and performance. Both the importance and the complexity of these tasks increase with the constant growth of the total data volumes during the active data taking period at the LHC. The use of common solutions helps to reduce the maintenance costs, both at the large Tier1 facilities supporting multiple virtual organizations and at the small sites that often lack manpower. We discuss requirements and solutions to the common tasks of data storage accounting and verification, and present experiment-specific strategies and implementations used within the LHC experiments according to their computing models.

Huang, C. H.↗

Coordination of Endoplasmic Reticulum (ER) Signaling During Maize Seed Development

Seed storage reserves represent one of the most important sources of renewable fixed carbon and nitrogen found in nature. Seeds are well-adapted for diverting metabolic resources to synthesize storage proteins as well as enzymes and structural proteins needed for their transport and packaging into membrane bound storage protein bodies. Our underlying hypothesis is that the endoplasmic reticulum (ER) stress response provides the critical cellular control of metabolic flux required for optimal accumulation of storage reserves in seeds. This highly conserved response is a cellular mechanism to monitor the protein folding environment of the ER and restore homeostasis in the presence of unfolded or misfolded proteins. In seeds, deposition of storage proteins in protein bodies is a highly specialized process that takes place even in the presence of mutant proteins that no longer fold and package properly. The capacity of the ER to deposit these aberrant proteins in protein bodies during a period that extends several weeks provides an excellent model for deconvoluting the ER stress response of plants. We have focused in this project on the means by which the ER senses and responds to functional perturbations and the underlying intracellular communication that occurs among biosynthetic, trafficking and degradative pathways for proteins during seed development.

09 BIOMASS FUELS↗

Co-scheduling of network resource provisioning and host-to-host bandwidth reservation on high-performance network and storage systems

A cross-domain network resource reservation scheduler configured to schedule a path from at least one end-site includes a management plane device configured to monitor and provide information representing at least one of functionality, performance, faults, and fault recovery associated with a network resource; a control plane device configured to at least one of schedule the network resource, provision local area network quality of service, provision local area network bandwidth, and provision wide area network bandwidth; and a service plane device configured to interface with the control plane device to reserve the network resource based on a reservation request and the information from the management plane device. Corresponding methods and computer-readable medium are also disclosed.

97 MATHEMATICS AND COMPUTING↗

Mathematical Modelling-Based Energy System Operation Strategy Considering Energy Storage Systems

Renewable energy resources are widely recognized as an alternative to environmentally harmful fossil fuels. More renewable energy technologies will need to penetrate into fossil fuel dominated energy systems to mitigate the globally witnessed climate changes and environmental pollutions. It is necessary to prepare for the potential problems with increased proportions of renewable energy in the energy system, to prevent higher costs and decreased reliability. Motivated by this need, this paper addresses the operation of an energy system with an energy storage system in the context of developing a decision-supporting framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Groundwater and Terrestrial Water Storage

Groundwater is a vital resource and also a dynamic component of the water cycle. Unconfined aquifer storage is less responsive to short term weather conditions than the near surface terrestrial water storage (TWS) components (soil moisture, surface water, and snow). However, save for the permanently frozen regions, it typically exhibits a larger range of variability over multi-annual periods than the other components. Groundwater is poorly monitored at the global scale, but terrestrial water storage (TWS) change data from the Gravity Recovery and Climate Experiment (GRACE) satellite mission are a reasonable proxy for unconfined groundwater at climatic scales.

Rodell, Matthew↗

Solar and Storage Integration in the U.S. Southeast: Implications for Resource Adequacy [Slides]

In this study, we evaluate how an iterative portfolio approach compares to a more traditional capacity credit method, using the U.S. Southeast as a case study region. Using open-source planning and resource adequacy tools, we compare results using a capacity credit approximation method with those from iterating behind the two. We also explore how the iterative approach performs under a range of sensitivities, including higher load growth, regional coordination, and alternative weather years. We find that traditional capacity credit approximation methods can function well in today's system, but may face challenges for systems with higher levels of solar and storage. As such, integrating planning and resource adequacy models can address some of these gaps, helping planners deliver more reliable systems.

14 SOLAR ENERGY↗

Variable Resource Resilience: How Systems Experience Increased Resilience from Variable and Hybrid Resources

Variable resources like wind and solar are often seen as detriments to system resilience rather than benefits because they may not be available with the capacities or services required during a high-impact low-frequency (HILF) event, whether that is a physical threat, natural disaster, or cyber attack. However, resilience goals and metrics are inadequate for electric energy delivery systems with inverter-based resources. Examination of this topic reveals that renewable resources are well suited to combat many resilience hazards due to local resource availability. Metrics that demonstrate the resilience value of variable resources are presented and categorized for resource (wind, solar, storage, hybrid) and installation type (bulk utility scale, behind-the-meter, front-of-the-meter, isolated). Distributed and hybrid systems can further enhance resilience benefits my maximizing resource potential for a locality. A case study demonstrating quantitative resilience benefits from wind alone is provided for St. Mary's, AK, which concludes that hundreds of thousands of dollars are saved by the addition of a wind turbine in the face of realistic fuel shortage and extreme winter weather scenarios.

17 WIND ENERGY↗

Sizing Energy Storage to Accommodate High Penetration of Variable Energy Resources

Abstract—The variability and non-dispatchable nature of wind and solar energy production presents substantial challenges for maintaining system balance. Depending on the economic considerations, energy storage can be a viable solution to balance energy production with consumption. This paper proposes to use discrete Fourier transform to decompose the required balancing power into different time-varying periodic components, i.e., intra-week, intra-day, intra-hour, and real-time. Each component can be used to quantify the maximum energy storage requirement for different types of energy storage. This requirement is the physical limit that could be theoretically accommodated by a power system. The actual energy storage capacity can be further quantified within this limit by the cost-benefit analysis (future work). The proposed approach has been successfully used in a study conducted for the 2030 Western Electricity Coordinating Council (WECC) system model. Some results of this study are provided in this paper.

Makarov, Yuri V.↗

Opportunities and Strategies for Testing and Infusion of ISRU in the Evolvable Mars Campaign

HE Evolvable Mars Campaign (EMC) is developing the plans and systems needed for a robust, evolutionary strategy to explore cis-lunar space, the Mars sphere of influence (including the moons of Mars), and the surface of Mars. Recently, the emphasis of NASA's plans has changed to focus on the prolonged pioneering of space, rather than focusing on a single crewed mission as the ultimate goal. A sustainable, pioneering vision of space would include in-situ resource utilization (ISRU) in multiple forms and at multiple destinations: atmospheric capture of Mars CO2 and/or volatiles for consumables and propellants, regolith for bulk and refined materials, and in-situ manufacturing at the Moon, Mars, and other bodies. These resources would enable a reduction in the logistical needs from Earth for future missions, thus preparing the way for a sustained presence on Mars. Although the EMC initially relies only on propellant production for the Mars ascent vehicle via ISRU, one of its primary objectives is to prospect at every EMC destination to understand the potential for ISRU; this will permit true pioneering to be enabled after the first crew arrives at Mars. Recent and ongoing analysis has considered the possible prospecting measurements that can be performed at the asteroid returned to cis-lunar space by the Asteroid Robotic Redirect Mission (ARRM), at the lunar surface, at Phobos and Deimos, and on the surface of Mars to identify available resources for future use. These opportunities will be available on missions currently in the Evolvable Mars Campaign construct, and will also facilitate the testing and demonstration of resource acquisition, processing, storage, and useage technologies that can play a role in later missions. This analysis has also led to the identification of several objectives that should be targeted during the missions building up to and including the initial crewed missions. These objectives are mapped to strategies for incorporating ISRU to support resource cycle closure and reduce mass requirements from Earth. This analysis has yielded engineering constraints, based on ISRU, that impact the evaluation of landing sites for missions to the surface of Mars. The terrain of a particular site must be sufficiently flat to permit ISRU systems, as well as ancillary systems such as power and propellant storage tanks, to be landed, moved into position, set up, and operated. Water must be accessible in a form that can be acquired via ISRU, in quantities that align with demands. The chosen method of acquiring and processing water should align with the available resources at a particular site, and that site must have sufficient quantities to meet the requirements (based on crew consumables and propellant demands). Lower altitude landing sites are preferred, as the increase in density can facilitate carbon dioxide acquisition from the atmosphere. Another preference is for sites with a greater ability to move regolith for civil engineering purposes; for example, this would be conducive to both bulk regolith uses (such as the manufacture of berms), and processed regolith uses (such as microwave sintering).

Evolvable Mars Campaign↗