Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectroscopic methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Adsorption Behavior of Organic Molecules: A Study of Benzotriazole on Cu(111) with Spectroscopic and Theoretical Methods

The adsorption of organic molecules on solid substrates is important to applications in fields such as catalysis, photovoltaics, corrosion inhibition, adhesion, and sensors. The molecular level description of the surface–molecule interaction and of the adsorption structures in these complex systems is crucial to understand their properties and function. Here, we present an investigation of one such system, benzotriazole (BTAH) on single-crystal Cu(111) in vacuum conditions. BTAH is the most widely used corrosion inhibitor for copper and thus a molecule of great industrial relevance. We show that the co-application of a wide range of spectroscopic techniques with theoretical methods provides unique insight in the description of the atomistic details of the adsorbed structures. Specifically, spectroscopic photoemission, absorption, and standing wave experiments combined with ab initio computational modeling allowed us to identify that benzotriazole forms overlayers of intact BTAH when deposited at low temperature, and it dissociates into BTA and H at room temperature and above. The dissociated molecule then forms complex structures of mixed chains and dimers of BTA bound to copper adatoms. Our work also reveals that copper adatoms at low concentrations, such as the theoretically predicted superstructures, cannot be resolved by means of current X-ray photoelectron spectroscopy as the modeled Cu 2p spectra are practically indistinguishable from those for a Cu surface without adatoms. Overall this study significantly deepens understanding of BTAH on Cu, a system studied for more than 50 years, and it highlights the benefits of combining spectroscopic and computational methods to obtain a complete picture of a complex adsorption system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Least squares methods of analyzing spectroscopic data

The development of efficient techniques for extracting the maximum amount of information from the spectra of atmospheric molecules with a minimum of observer bias is discussed. In particular, an overview of the methods of line by line and whole band analysis is presented.

Shaw, J. H.↗

Investigation of electrolyte measurement in diluted whole blood using spectroscopic and chemometric methods

The feasibility of using near-infrared (NIR) spectroscopy in combination with partial least-squares (PLS) regression was explored to measure electrolyte concentration in whole blood samples. Spectra were collected from diluted blood samples containing randomized, clinically relevant concentrations of Na+, K+, and Ca2+. Sodium was also studied in lysed blood. Reference measurements were made from the same samples using a standard clinical chemistry instrument. Partial least squares (PLS) was used to develop calibration models for each ion with acceptable results (Na+, R2 = 0.86, CVSEP = 9.5 mmol/L; K+, R2 = 0.54, CVSEP = 1.4 mmol/L; Ca2+, R2 = 0.56, CVSEP = 0.18 mmol/L). Slightly improved results were obtained using a narrower wavelength region (470-925 nm) where hemoglobin, but not water, absorbed indicating that ionic interaction with hemoglobin is as effective as water in causing measurable spectral variation. Good models were also achieved for sodium in lysed blood, illustrating that cell swelling, which is correlated with sodium concentration, is not required for calibration model development.

Non-NASA Center↗

Chemical Kinetic Method for Active-Site Quantification in Fe-N-C Catalysts and Correlation with Molecular Probe and Spectroscopic Site-Counting Methods

Mononuclear Fe ions ligated by nitrogen (FeN x ) dispersed on nitrogen-doped carbon (Fe-N-C) serve as active centers for electrocatalytic O 2 reduction and thermocatalytic aerobic oxidations. Despite their promise as replacements for precious metals in a variety of practical applications, such as fuel cells, the discovery of new Fe-N-C catalysts has relied primarily on empirical approaches. In this context, the development of quantitative structure–reactivity relationships and benchmarking of catalysts prepared by different synthetic routes and by different laboratories would be facilitated by the broader adoption of methods to quantify atomically dispersed FeN x active centers. In the present study, we develop a kinetic probe reaction method that uses the aerobic oxidation of a model hydroquinone substrate to quantify the density of FeN x centers in Fe- N-C catalysts. The kinetic method is compared with low-temperature Mössbauer spectroscopy, CO pulse chemisorption, and electrochemical reductive stripping of NO derived from NO 2 – on a suite of Fe-N-C catalysts prepared by diverse routes and featuring either the exclusive presence of Fe as FeN x sites or the coexistence of aggregated Fe species in addition to FeN x . The FeN x site densities derived from the kinetic method correlate well with those obtained from CO pulse chemisorption and Mössbauer spectroscopy. The broad survey of Fe-N-C materials also reveals the presence of outliers and challenges associated with each site quantification approach. Furthermore, the kinetic method developed here does not require pretreatments that may alter active-site distributions nor specialized equipment beyond reaction vessels and analytical instrumentation (e.g., NMR).

36 MATERIALS SCIENCE↗

Method of absorbance correction in a spectroscopic heating value sensor

A method and apparatus for absorbance correction in a spectroscopic heating value sensor in which a reference light intensity measurement is made on a non-absorbing reference fluid, a light intensity measurement is made on a sample fluid, and a measured light absorbance of the sample fluid is determined. A corrective light intensity measurement at a non-absorbing wavelength of the sample fluid is made on the sample fluid from which an absorbance correction factor is determined. The absorbance correction factor is then applied to the measured light absorbance of the sample fluid to arrive at a true or accurate absorbance for the sample fluid.

47 OTHER INSTRUMENTATION↗

The completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: a catalogue of strong galaxy–galaxy lens candidates

ABSTRACT We spectroscopically detected 838 likely, 448 probable, and 265 possible strong lens candidates within ≈2 million galaxy spectra contained within the extended Baryon Oscillation Spectroscopic Survey (eBOSS) from the sixteenth data release (DR16) of the Sloan Digital Sky Survey (SDSS). We apply the spectroscopic detection method of the Baryon Oscillation Spectroscopic Survey (BOSS) Emission-Line Lens Survey (BELLS) and add Gaussian fit information, grading, additional inspection observables, and additional inspection methods to improve our selection method. We observed 477 candidates with lensing evidence within low-resolution images from both the Legacy survey of SDSS-I/II and the DESI Legacy survey, which is $12{{\ \rm per\ cent}}$ higher than the percentage of BELLS candidates observed with similar lensing evidence. Our search within the latest and improved reductions of the BOSS survey yielded a $20{{\ \rm per\ cent}}$ increase in the number of lens candidates expected from searching all BOSS and eBOSS galaxies. The distribution of target and background redshifts of our candidates is similar to the candidates and confirmed lenses within the BELLS observations. We present our Spectroscopic Identification of Lensing Object candidates in a value-added catalogue in SDSS DR16. The examination of these lens candidates in follow-up high-resolution imaging may yield more than twice the lenses found in previous spectroscopic detection surveys within SDSS, which would extend the results of previous lens surveys within SDSS to higher redshifts, constrain models of mass structures in spiral galaxies, and test if including the identification of possible lensing features within low-resolution images has merit to spectroscopic detection programmes.

Talbot, Michael S.↗

Near-infrared diode laser based spectroscopic detection of ammonia: a comparative study of photoacoustic and direct optical absorption methods

A photoacoustic spectroscopic (PAS) and a direct optical absorption spectroscopic (OAS) gas sensor, both using continuous-wave room-temperature diode lasers operating at 1531.8 nm, were compared on the basis of ammonia detection. Excellent linear correlation between the detector signals of the two systems was found. Although the physical properties and the mode of operation of both sensors were significantly different, their performances were found to be remarkably similar, with a sub-ppm level minimum detectable concentration of ammonia and a fast response time in the range of a few minutes.

NASA Discipline Life Sciences Technologies↗

Spectroscopic aspects of differential method for sounding gas composition of the atmosphere

The problems concerning the dynamics of populations of the sounded atmospheric gas molecule levels taking into account the nonmonochromatic character of radiation, durations of exciting and sounding pulses, rates of relaxation of excited vibration-rotation states population along different channels in a natural multicomponent mixture of gases and air were investigated. The problems of spectroscopic software, completeness and accuracy of the initial spectroscopic information, information on channels and rates of relaxation from the viewpoint of developing specific schemes of sounding are discussed. The values of deviations of vibration-rotation level populations of some atmospheric molecules from their equilibrium value at simultaneous action of double frequency radiation on the sounding path and the corresponding dynamic variation of lidar return amplitude were estimated. The importance of nonlinear spectrosopic effects in the lidar return value variation at sounding radiation frequency equaling the resonance frequency of vibration-rotation transition in the problem on sounding the humidity profiles and concentrations of gaseous pollutants was also estimated.

Zuev, V. V.↗

Structure, electrical characteristics, and high-temperature stability of aerosol jet printed silver nanoparticle films

Printed electronics has emerged as a versatile eco-friendly fabrication technique to create sintered nanoparticle (NP) films on arbitrary surfaces with an excellent control over the film microstructure. While applicability of such films for high-temperature applications is not explored previously, herein we report the high-temperature electrical stability of silver (Ag) metal NP films fabricated using an Aerosol Jet based printing technique and demonstrate that this behavior is dictated by changes in the film microstructure. In-situ high temperature (24–500 °C) impedance spectroscopy measurements show that the real part of the impedance increases with increasing temperature up to 150 °C, at which point a decreasing trend prevails until 300 °C, followed again by an increase in impedance. The electrical behavior is correlated with the in-situ grain growth of the Ag NP films, as observed afterwards by scanning electron microscopy and X-ray diffraction (XRD), and could be tailored by controlling the initial microstructure through sintering conditions. Using combined diffraction and spectroscopic analytical methods, it is demonstrated the Aerosol Jet printed Ag NP films exhibit enhanced thermal stability and oxidation resistance. In addition to establishing the conditions for stability of Ag NP films, the results provide a fundamental understanding of the effect of grain growth and reduction in grain boundary area on the electrical stability of sintered NP films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computation of Spectroscopic Factors with the Coupled-Cluster Method

We present a calculation of spectroscopic factors within coupled-cluster theory. Our derivation of algebraic equations for the one-body overlap functions are based on coupled-cluster equation-of-motion solutions for the ground and excited states of the doubly magic nucleus with mass number A and the odd-mass neighbor with mass A-1. As a proof-of-principle calculation, we consider ^{16}O and the odd neighbors ^{15}O and ^{15}N, and compute the spectroscopic factor for nucleon removal from ^{16}O. We employ a renormalized low-momentum interaction of the V_{low-k} type derived from a chiral interaction at next-to-next-to-next-to-leading order. We study the sensitivity of our results by variation of the momentum cutoff, and then discuss the treatment of the center of mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CHAPTER 7. BERYLLIUM ANALYSIS BY NON-PLASMA BASED METHODS

The most common method of analysis for beryllium is inductively coupled plasma atomic emission spectrometry (ICP-AES). This method, along with inductively coupled plasma mass spectrometry (ICP-MS), is discussed in Chapter 6. However, other methods exist and have been used for different applications. These methods include spectroscopic, chromatographic, colorimetric, and electrochemical. This chapter provides an overview of beryllium analysis methods other than plasma spectrometry (inductively coupled plasma atomic emission spectrometry or mass spectrometry). The basic methods, detection limits and interferences are described. Specific applications from the literature are also presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The application of visible absorption spectroscopy to the analysis of uranium in aqueous solutions

Through assay analysis into an excess of 1 M H 2 SO 4 at fixed temperature a technique has been developed for uranium concentration analysis by visible absorption spectroscopy over an assay concentration range of 1.8 – 13.4 mgU/g. Once implemented for a particular spectrophotometer and set of spectroscopic cells this technique promises to provide more rapid results than a classical method such as Davies-Gray (DG) titration analysis. While not as accurate and precise as the DG method, a comparative analysis study reveals that the spectroscopic method can analyze for uranium in well characterized uranyl(VI) solution samples to within 0.3% of the DG results. For unknown uranium solutions in which sample purity is less well defined agreement between the developed spectroscopic method and DG analysis is within 0.5%. The technique can also be used to detect the presence of impurities that impact the colorimetric analysis, as confirmed through the analysis of ruthenium contamination. Finally, extending the technique to other assay solution, 1 M HNO 3 , HCl and Na 2 CO 3 , has also been shown to be viable. As a result, of the four aqueous media the carbonate solution yields the largest molar absorptivity value at the most intensely absorbing band, with the least impact of temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Near-resonance spin-noise spectroscopy

Spectroscopy of atomic spin noise allows the determination of many sample properties such as energy-level structures and transverse-spin relaxation rates without the need to drive the system away from equilibrium with applied fields. Analysis of noise measurements can also reveal the processes that limit the sensitivity of a measured signal. Standard methods for spectroscopic noise measurements in atomic vapors rely on far-off-resonant optical probing. We present a method for investigating spin noise with a probe beam frequency relatively close to resonance and show how the back action of the probe on the atomic state can be subtracted from the recorded noise spectra. We verify this method experimentally by showing noise data that scale with the square root of the number of atoms, after the probe back action has been properly subtracted.

74 ATOMIC AND MOLECULAR PHYSICS↗