Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shaped beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Subsurface spectroscopy of heterogeneous materials using optical wavefront shaping

Plastic-bonded explosives and propellants consist of energetic molecular crystals embedded in a polymer matrix that also includes additives, such as taggants, plasticizers, grit, antioxidants, etc. Furthermore, this heterogeneous composition renders these materials optically opaque, limiting optical characterization techniques (e.g., Raman spectroscopy) to probing chemical reactions at the sur-face. However, many reactions of interest are believed to occur inside the material where current optical techniques can not probe. To address this challenge, we have developed a new optical technique that utilizes feedback assisted wavefront shaping (using spatial light modulators) to focus probe light inside a heterogeneous material, such that we can perform subsurface spectroscopy. Recently, we demonstrated this technique by monitoring subsurface photodegradation and thermal degradation of Eu-doped molecular crystals using both fluorescence and Raman spectroscopy. Based off these successes we are now looking into improvements to this technique to allow for greater time resolution, including replacing our spatial light modulators with fast digital mirror devices, using ns optical phase conjugation, and self-healing optical beams.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Constraining the local pulsar population with the cosmic-ray positron fraction

Observations of the TeV halos associated with nearby pulsars indicate that these objects inject significant fluxes of very high-energy electron-positrons pairs into the interstellar medium (ISM), thereby likely providing the dominant contribution to the cosmic-ray positron flux. In this paper, we use the cosmic-ray positron fraction as measured by the AMS-02 Collaboration to constrain the characteristics of the local pulsar population. For reasonable model parameters, we find that we can obtain good agreement with the measured positron fraction up to energies of E e ~ 300 GeV. At higher energies, the positron fraction is dominated by a small number of pulsars, making it difficult to reliably predict the shape of the expected positron fraction. The low-energy positron spectrum supports the conclusion that pulsars typically transfer approximately η ~ 5–20% of their total spindown power into the production of very high-energy electron-positron pairs, producing a spectrum of such particles with a hard spectral index, α ~ 1.5–1.7. Such pulsars typically spindown on a timescale on the order of τ ~ 10 4 years. Our best fits were obtained for models in which the radio and gamma-ray beams from pulsars are detectable to 28% and 62% of surrounding observers, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The effect of plasma shaping on high density H-mode SOL profiles and fluctuations in TCV

Abstract The impact of plasma shaping on the properties of high density H-mode scrape-off layer (SOL) profiles and transport at the outer midplane has been investigated on Tokamakà configuration variable. The experimental dataset has been acquired by evolving the upper triangularity while keeping the other parameters constant. The scan comprises δ u p values between 0.0 and 0.6, excluding negative triangularity scenarios. Within this study, a transition from type-I edge localised modes to the quasi-continuous exhaust regime takes place from low to high δ u p . The modification of the upstream SOL profiles has been assessed, in terms of separatrix quantities, within the α t turbulence control parameter theoretical framework (Eich et al 2020 Nucl. Fusion 60 056016). The target parallel heat load and the upstream near-SOL density profiles have been shown to broaden significantly for increasing α t . Correspondingly, in the far SOL a density shoulder formation is observed when moving from low to high δ u p . These behaviours have been correlated with an enhancement of the SOL fluctuation level, as registered by wall-mounted Langmuir probes as well as the thermal helium beam diagnostic. Specifically, both the background and the filamentary-induced fluctuating parts of the first wall ion saturation current signal are larger at higher δ u p , with filaments being ejected more frequently into the SOL. Comparison of two pulses at the extremes of the δ u p scan range, but with otherwise same input parameters, shows that the midplane neutral pressure does not change much during the H-mode phase of the discharge. This indicates that indirect effects of the change in geometry, linked to first wall recycling sources, should not play a significant role. The total core radiation increases at high δ u p , on account of a stronger plasma–wall interaction and resulting larger carbon impurity intake from the first wall. This is likely associated to the enhanced first wall fluctuations, as well as a smaller outer gap and the close-to-double-null magnetic topology at high shaping.

Stagni, A. (ORCID:0000000180841544)↗

Use of Neutrino Scattering Events with Low Hadronic Recoil to Inform Neutrino Flux and Detector Energy Scale

Charged-current neutrino interactions with low hadronic recoil ("low-nu") have a cross-section that is approximately constant versus neutrino energy. These interactions have been used to measure the shape of neutrino fluxes as a function of neutrino energy at accelerator-based neutrino experiments such as CCFR, NuTeV, MINOS and MINERvA. In this paper, we demonstrate that low-nu events can be used to measure parameters of neutrino flux and detector models and that utilization of event distributions over the upstream detector face can discriminate among parameters that affect the neutrino flux model. From fitting a large sample of low-nu events obtained by exposing MINERvA to the NuMI medium-energy beam, we find that the best-fit flux parameters are within their a priori uncertainties, but the energy scale of muons reconstructed in the MINOS detector is shifted by 3.6% (or 1.8 times the a priori uncertainty on that parameter). These fit results are now used in all MINERvA cross-section measurements, and this technique can be applied by other experiments operating at MINERvA energies, such as DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A substandard candle: the low-$$\nu $$ method at few-GeV neutrino energies

Abstract As accelerator-based neutrino oscillation experiments improve oscillation parameter constraints with more data, control over systematic uncertainties on the incoming neutrino flux and interaction models is increasingly important. The intense beams offered by modern experiments permit a variety of options to constrain the flux using in situ “standard candle” measurements. These standard candles must use very well understood interaction processes to avoid introducing additional interaction model dependence. One option often discussed in this context is the “low- $$\nu $$ ν ” method, which is designed to isolate neutrino interactions where there is low energy-transfer to the nucleus, such that the interaction cross section is expected to be approximately constant as a function of neutrino energy. The shape of the low-energy transfer event sample can then be used to extract the flux shape. Applications of the method at high neutrino energies (many tens of GeV) are well understood. However, the applicability of the method at the lower energies of current and future few-GeV accelerator neutrino experiments remains unclear due to the presence of nuclear and form-factor effects inherent in the interaction models.In this analysis we examine the prospects for improving constraints on the accelerator neutrino fluxes in situ with the low- $$\nu $$ ν method in an experiment-independent way, using (anti)neutrino interactions on argon and hydrocarbon targets from the GENIE, NEUT, NuWro and GiBUU event generators. We begin by investigating the extent to which deviations from the constant cross-section assumption are dependent on poorly understood aspects of the neutrino interaction model. We then assess whether a low energy-transfer event sample can be confidently identified using experimentally accessible observables. We finally consider how the practicalities of reconstructing the energy spectrum of interacting neutrinos in realistic detectors might further limit the utility of low- $$\nu $$ ν flux constraints. The results show that flux constraints from the low- $$\nu $$ ν method would be severely dependent on the interaction model assumptions used in an analysis of neutrinos with energies below 5 GeV, and anti-neutrinos below at least 15 GeV. The spread of model predictions show that a low- $$\nu $$ ν analysis is unlikely to offer much improvement on typical neutrino flux uncertainties, even with a perfect detector. Notably—running counter to the assumption inherent to the low- $$\nu $$ ν method—the model-dependence increases with decreasing energy transfer for experiments in the few-GeV region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-shot measurements of pulse-front tilt in intense ps laser pulses and its effect on accelerated electron and ion beam characteristics (invited)

Here we report recent single-shot spatiotemporal measurements of laser pulses, including pulse-front tilt (PFT) and spatial chirp, taken at the Compact Multipulse Terawatt laser at the Jupiter Laser Facility in Livermore, CA. STRIPED FISH, a device that measures the complete 3D electric field of fs to ps laser pulses on a single shot, was adapted to near infrared for these measurements. We present the design of the instrument used for these experiments, the on-shot measurements of systematic high-order PFT, and shot-to-shot variations in the measurements of spatiotemporal couplings. Finally, we simulate the effect of PFT in target normal sheath acceleration experiments. These simulations showed that pulse front tilt can steer hot electrons, shape the distribution of the accelerating sheath field, and increase the variability of cutoff energy in the resulting proton spectra. While these effects may be detrimental to experimental accuracy if the pulse front tilt is left unmeasured, hot electron steering shows promise for precision manipulation of the particle source for a range of applications, including irradiation of secondary targets for opacity measurements, radiography, or neutron generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experiments at Jefferson Lab

This chapter presents experiments conducted at Thomas Jefferson National Accelerator Facility (Jefferson Lab), a U.S. Department of Energy national laboratory in Newport News, Virginia. There, physicists exploring the nature of matter make use of the Continuous Electron Beam Accelerator Facility (CEBAF), a DOE Office of Science user facility that enables the research of more than 1,650 scientists worldwide. CEBAF’s precise electron beams can reach energies up to 12 billion electron-volts and exhibit high degrees of polarization. Jefferson Lab’s first experiment began taking data in 1995. Since then, the facility has become a world leader in the study of quantum chromodynamics. Today, experiments are carried out simultaneously in four experimental halls, each with specialized capabilities. The primary instruments in use are focusing or large-acceptance magnetic spectrometers, many of which feature superconducting elements. Jefferson Lab’s physics program provides unprecedented insight into the particles and forces that shape the visible universe.

Achenbach, Patrick [Thomas Jefferson National Acce↗

Results of High Order Modes Spectra Measurements in 1.3 GHz Cavities for LCLS-II

Fermilab recently completed production and testing of 1.3 GHz cryomodules for the LCLS-II project. Each cryomodule consists of eight TESLA-shaped superconducting elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is part of the incoming quality control of cavities at room temperature and the final qualification cold test of cryomodules at the Cryomodule Test Facility (CMTF). In this paper we describe the procedure for measuring the HOM spectrum along with further data processing. Finally, we present accumulated statistics of individual HOM frequencies and quality factors related to various cavity vendors and discuss the possible contribution of HOMs to heat loads and beam dynamics.

43 PARTICLE ACCELERATORS↗

Electron transport barrier and high confinement in configurations with internal islands close to the plasma edge of W7-X

The low magnetic shear in the Wendelstein 7-X (W7-X) stellarator makes it feasible to shape the separatrix by the large islands constituting an island-divertor, and this can be exploited to access various magnetic configurations, including samples of different internal island sizes and locations. To investigate the configuration effects on the plasma confinement, a configuration scan was performed by changing the coil currents to vary the rotational transform between values 5/4 and 5/6 at the plasma boundary with different power levels (2, 4, 6 MW) of electron cyclotron resonance heating (ECRH) at a maximum plasma density of 8 × 10 19 m -2 . neutral beam injection (NBI) heating was also applied during some configurations of the scan to create a density ramp and access high densities beyond the X2 ECRH cutoff. For the magnetic configurations, where the 5/5 and 5/6 island chains were moved closer to separatrix but remaining inside the last closed flux surface, the electron cyclotron emission shows that an electron temperature, T e , pedestal develops already during ECRH heated plasma buildup phase indicating a transport barrier, and the barrier sustains irrespective of changed plasma heating conditions such as NBI in the later part of discharge. The transport barrier is broken by subsequent fast crashes, observed with multiple plasma diagnostics with characteristics such as tokamak edge localized modes, and the corresponding crash amplitude and frequency vary with plasma pressure. The impact of the transport barrier on plasma confinement can be seen through the increased core T e profile, which could be responsible for the overall increase in the stored diamagnetic energy by approximately 10% for these configurations. After the plasma heating is terminated, a backwards transition to a degraded confinement state is also observed. These observations indicate a configuration triggered high confinement mode in low shear W7-X. This work focuses on the occurrence of this transport barrier for different magnetic configurations and its relation to internal magnetic islands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz $(10\bar{1}1)$ crystal.

47 OTHER INSTRUMENTATION↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Molecular-Resolution Electron Imaging of Defects and Dynamics at the Ice-Water Interface

Water crystallization into hexagonal ice (type I h ) is one of the most critical processes relevant to the Earth’s environment and human activities. However, despite recent breakthroughs in imaging non-equilibrium condensed ice structures, the ice-water interface has never been imaged at a molecular resolution. This is primarily due to the low stability of the hydrogen bonds in ice under high-resolution microscopy conditions and a lack of methods to prepare compatible samples. Here, this presentation describes the first molecular-resolution imaging of ice crystallized from liquid water and the ice-water interface using high-resolution transmission electron microscopy (HRTEM). By encapsulating deionized (DI) water between two amorphous carbon (a-C) TEM grids and subsequently freezing it with liquid N 2 on a cryo sample stage, we generated two types of ice: non-equilibrium, condensed ice from the atmosphere and encapsulated ice from the DI water (Fig. 1A). Condensed ice usually shows irregular, spherulitic shapes (Fig. 1B). Selected area electron diffraction (SAED) shows that they are a mixture of cubic and hexagonal crystals (Fig. 1C). On the contrary, encapsulated ice forms thin films that contain large-area single-crystalline regions of hexagonal ice oriented along the [0001] zone axis (Fig. 1D). Differential electron energy-loss spectroscopy (EELS) confirmed the high purity of the encapsulated ice free from organic contaminations that are common in other encapsulation methods for HRTEM such as graphene liquid cells. These single-crystalline areas are robust under the electron beam up to ~100 e/Å 2 s. Aberration-corrected HRTEM imaging in these areas achieved a line resolution of ~1.3 Å (Fig. 1E and F). This platform allows us to study near-equilibrium ice structures and dynamics at an unprecedented spatial resolution (Fig. 2). For example, we discovered subdomain-rich regions near the defective crystal edges despite the structure appearing single-crystalline according to diffraction criteria. These subdomains connect via low-angle grain boundaries with flat energy landscapes as a function of tilt angles (according to simulations), showing the high tolerance of ice to defect structures. When we tuned the sample temperature and electron flux rate, we observed radiolysis-controlled bubble generation and dissolution in ice single crystals near a steady state of bubble dynamics. Furthermore, rich beam-induced melting and recrystallization dynamics were observed at the ice-water interface with lattice resolution. These data represent the first observation of the ice-water phase transformation at the sub-nanometer level. In summary, the methods developed in this work enabled molecular-resolution observations of ice and the ice-water interface and shed light on the microstructures and phase transformation pathways. Finer control on the temperature, electron irradiation profile, and imaging detector could eventually lead to real-time observation of ice nucleation in water and address long-standing questions in the nucleation pathways.

74 ATOMIC AND MOLECULAR PHYSICS↗

A multi-institution collaboration to study copper wire hybrid and laser-cut foil X-pinches

X-pinches are a pulsed power wire-array configuration that produce nanosecond and micron-scale X-ray sources with numerous applications. The earliest embodiment of the X-pinch inspired its name, as it is typically composed of two or more fine (5-50 µm) wires crossed into the shape of an X (Fig. 1a). The ‘X’ ablates when subjected to large (10 1 -10 4 kA), fast-rising (~1 kA/ns) currents, and extreme magnetic pressure at the cross-point constricts the ablated plasma, which develops instabilities and then pinches to near-zero radius, localized ‘hot spots’, emitting X-rays from a sub-nanosecond and 1 µm scale source characteristic of a hot (~1 keV), dense (10% solid density) plasma. A subsequent gap forms where the hot spot(s) occurred, across which substantial potential accelerates electron beams (e-beams) that generate larger, longer-lasting X-ray bursts composed of harder X-rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring laser-material interactions of zirconium carbide under additive manufacturing conditions

Zirconium carbide (ZrC) is an ultra-high temperature ceramic with a melting temperature above 3000°C and a broad range of high temperature applications. Given the high melting and sintering temperatures of pure ZrC, producing near-net shape and fully dense parts remains challenging with conventional techniques. In this study, we investigate the fundamental laser-material interactions of ZrC under laser powder bed fusion (LPBF) additive manufacturing (AM) conditions. Normalized enthalpy, a scaling law term that is used in welding and AM literature for detailing laser-material interactions in metallic alloys, was calculated to determine the predictive capabilities of melt pool features in ZrC. Further, the melt pool quality of laser irradiated ZrC was used to compare LPBF relevant laser parameter combinations of laser power, scan speed, and beam diameter. Laser build parameters that resulted in desirable melt pool morphologies were applied to the fabrication of ZrC coupons using LPBF AM. A custom LPBF system was used to determine hatch spacing and layer height parameters that resulted in a fabricated sample with a density of 85% as measured by Archimedes and a Vicker's microhardness of 20.9 ± 1.9 GPa. This investigation reveals the laser-material interactions of ZrC under AM relevant conditions and is the first step towards LPBF fabrication of ZrC parts.

36 MATERIALS SCIENCE↗

HOM Spectra Measurements in 1.3 GHz Cavities for LCLS-II

Fermilab recently completed production and testing of 1.3 GHz cryomodules for the LCLS-II project. Each cryomodule consists of eight TESLA-shaped super-conducting elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is part of the incoming quality control of cavities at room temperature and the final qualification cold test of cryomodules at the Cryomodule Test Facility (CMTF). In this paper we describe the procedure for measuring the HOM spectrum along with further data processing. Finally, we present accumulated statistics of individual HOM frequencies and quality factors related to various cavity vendors and dis-cuss the possible contribution of HOMs to heat loads and beam dynamics.

Lunin, A.↗

Modulating the Pseudoelastic Response of NiTi Using Ion Implantation

Ni-ion irradiated NiTi is nearly 50% harder, retains 85% recoverable deformation, and has reduced hysteresis. This work explores the feasibility of using ion beam modification to modulate the austenite to martensite phase transformation in NiTi, thereby achieving novel or localized properties in near-surface regions.

36 MATERIALS SCIENCE↗

A Detailed Characterization of HR 8799's Debris Disk with ALMA in Band 7

The exoplanetary system of HR 8799 is one of the rare systems in which multiple planets have been directly imaged. Its architecture is strikingly similar to that of the solar system, with the four imaged giant planets surrounding a warm dust belt analogous to the Asteroid Belt, and themselves being surrounded by a cold dust belt analog to the Kuiper Belt. Previous observations of this cold belt with ALMA in Band 6 (1.3 mm) revealed its inner edge, but analyses of the data differ on its precise location. It was therefore unclear whether or not the outermost planet HR 8799 b was dynamically sculpting it. We present here new ALMA observations of this debris disk in Band 7 (340 GHz, 880 μm). These are the most detailed observations of this disk obtained so far, with a resolution of 1″ (40 au) and sensitivity of 9.8 μJy beam{sup −1}, which allowed us to recover the disk structure with high confidence. In order to constrain the disk morphology, we fit its emission using radiative transfer models combined with a Markov Chain Monte Carlo procedure. We find that this disk cannot be adequately represented by a single power law with sharp edges. It exhibits a smoothly rising inner edge and smoothly falling outer edge, with a peak in between, as expected from a disk that contains a high-eccentricity component, hence confirming previous findings. Whether this excited population and inner edge shape stem from the presence of an additional planet remains, however, an open question.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Equidistant optimization of elliptical superconducting rf standing wave cavities

A record accelerating rate was achieved earlier in standing wave (SW) SRF cavities when their shape was optimized for a lower peak surface magnetic field sacrificing the peak surface electric field. In view of new materials with higher limiting magnetic fields, expected for SRF cavities, in the first line of the Nb 3 Sn, the approach to optimization of cavity shape should be revised. A method of equidistant optimization, offered earlier for traveling wave (TW) cavities is applied to SW cavities. It is shown here that without limitation by magnetic field, the maximal accelerating rate is defined not only by limitations of the electric field but to a significant degree by the cavity shape. For example, for a cavity with the aperture radius of $R$ $a$ = 35 mm, the minimal ratio of the peak surface electric field to the accelerating rate is about $E$ pk / $E$ acc = 1.54. So, with the maximal surface field experimentally achieved $E$ pk ~ 125 MV / m, the maximal achievable accelerating rate is about 80 MeV / m even if there are no restrictions by the magnetic field. Optimized cavity shapes with and without limitations by a magnetic field are presented. Another opportunity—optimization for a low magnetic field, is opening for the same material, Nb 3 Sn, with the purpose of having a high-quality factor and increased accelerating rate that can be used for industrial linacs with cryocooler-based cooling scheme.

43 PARTICLE ACCELERATORS↗