Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Assimilating Scanning Radar Data into High-Resolution Models

This report documents the findings of a project aiming to improve the initial conditions of km-scale simulations of deep convective storms by assimilating cloud-scale weather radar observations. More accurate numerical analyses will increase the effectiveness of research efforts using LES cloud models as tool to better understand land-atmosphere coupling, boundary layer turbulence, and cloud processes, each used for model parameterization development. Work reported on herein includes: i) assessment of radar data sets for use in data assimilation (‘DA’) experiments, ii) quality control of the radar data set and format conversion to one acceptable to DA schemes utilized by the Weather Research and Forecasting (WRF) model, and iii) examination of the sensitivity of the numerical representation of cloud-scale wind and microphysical features to a variety of tunable DA parameters.

54 ENVIRONMENTAL SCIENCES↗

Atomic-scale Imaging of Magnetic and Electronic Orders in Complex Oxides (Final Technical Report)

This research project aimed to expand spin‐polarized scanning tunneling microscopy (SP‐STM) imaging to complex quantum materials, initially focusing on uncovering the magnetic structure of doped Iridium‐based oxides (iridates) with subatomic precision. Chemical doping of complex oxides has led to exciting discoveries over the past few decades, such as high-temperature superconductivity and colossal magnetoresistance. However, the process of chemical doping is often accompanied by spatial inhomogeneity, characterized by nanometer-scale variations in electronic and/or magnetic properties of the material. SP-STM can in principle be used to image magnetic properties, but SP-STM has historically been applied primarily to relatively simple magnetic materials and nanostructures. The main objectives of this project included: (1) visualizing the evolution of magnetism in iridates, as a function of charge carrier doping, temperature and energy, (2) elucidating the relationship between the inhomogeneous electronic structure and magnetism at the nanoscale, and (3) searching for signatures of new magnetic phases in iridates and other quantum materials. Advanced STM and SP-STM imaging was also applied to select kagome metals and superconductors. The comprehensive experimental approach developed in this project provided a foundation to study quantum materials in which spin, charge and orbital degrees of freedom intertwine to create new states of matter.

36 MATERIALS SCIENCE↗

Characterization of synthetic carrier ampholytes by repetitive scanning of the electric field during focusing

This paper reports the utilization of a potential gradient array detector for monitoring the dynamics of the electric field during isoelectric focusing. Transient and steady state electric field profiles are presented for synthetic carrier ampholyte mixtures with a wide (about 3-10) pH range. Two available commercial products (Ampholine and Pharmalyte) and a laboratory synthesized mixture (PEHA ampholytes) are compared. The formation of conductivity gaps and their migration toward the cathode in extended experiments (cathodic drift) can be visualized with this system.

Thormann, W.↗

TH-AB-207A-12: CT Lung Cancer Screening and the Effects of Further Dose Reduction On CAD Performance

Purpose: CT lung screening is already performed at low doses. In this study, we investigated the effects of further dose reduction on a lung-nodule CAD detection algorithm. Methods: The original raw CT data and images from 348 patients were obtained from our local database of National Lung Screening Trial (NLST) cases. 61 patients (17.5%) had at least one nodule reported on the NLST reader forms. All scans were acquired with fixed mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare). All images were reconstructed with 1-mm slice thickness, B50 kernel. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions of each case at 50% and 25% of the original NLST dose (i.e. approximately 1.0 and 0.5 mGy CTDIvol). For each case at each dose level, a CAD detection algorithm was run and nodules greater than 4 mm in diameter were reported. These CAD results were compared to “truth”, defined as the approximate nodule centroids from the NLST forms. Sensitivities and false-positive rates (FPR) were calculated for each dose level, with a sub-analysis by nodule LungRADS category. Results: For larger category 4 nodules, median sensitivities were 100% at all three dose levels, and mean sensitivity decreased with dose. For the more challenging category 2 and 3 nodules, the dose dependence was less obvious. Overall, mean subject-level sensitivity varied from 38.5% at 100% dose to 40.4% at 50% dose, a difference of only 1.9%. However, median FPR quadrupled from 1 per case at 100% dose to 4 per case at 25% dose. Conclusions: Dose reduction affected nodule detectability differently depending on the LungRADS category, and FPR was very sensitive at sub-screening levels. Care should be taken to adapt CAD for the very challenging noise characteristics of screening. Funding support: NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

LDEF meteoroid and debris special investigation group investigations and activities at the Johnson Space Center

Since the return of the Long Duration Exposure Facility (LDEF) in January, 1990, members of the Meteoroid and Debris Special Investigation Group (M&D SIG) at the Johnson Space Center (JSC) in Houston, Texas have been examining LDEF hardware in an effort to expand the knowledge base regarding the low-Earth orbit (LEO) particulate environment. In addition to the various investigative activities, JSC is also the location of the general Meteoroid & Debris database. This publicly accessible database contains information obtained from the various M&D SIG investigations, as well as limited data obtained by individual LDEF Principal Investigators. LDEF exposed approximately 130 m(exp 2) of surface area to the LEO particulate environment, approximately 15.4 m(exp 2) of which was occupied by structural frame components (i.e., longerons and intercoastals) of the spacecraft. The data reported here was obtained as a result of detailed scans of LDEF intercoastals, 68 of which reside at JSC. The limited amount of data presently available on the A0178 thermal control blankets was reported last year and will not be reiterated here. The data presented here are limited to measurements of crater diameters and their frequency of occurrence (i.e., flux).

See, Thomas H.↗

MO-F-16A-05: Spot-Scanning Proton Therapy Patient-Specific Quality Assurance: Our Methodology and Results From 295 Treatment Plans

Purpose: To report on the patient-specific quality assurance (PSQA) results for 295 spot-scanning proton therapy treatment plans from the MD Anderson PTC-Houston. We show how the results differed by treatment site and how they were affected by the treatment plan optimization method and by a range shifter in the treatment field. We also discuss some causes of PSQA problems. Methods: The PSQA procedure, which is designed to verify both the accuracy of the treatment planning system's (Eclipse™ v8.9) dose calculations and the dose delivery of the Hitachi PROBEAT synchrotron, consists of (1) an end-to-end test in which the beam is delivered and measured at the prescribed gantry angle, and (2) additional dose plane measurements made from gantry angle 270°. HPlusQA™ software automatically performs the gamma analysis with criteria 3% (dose tolerance), 3 mm (distance-to-agreement, DTA) and 2%, 2 mm. Passing is defined as at least 90% of the pixels having a gamma score less than 1. Results: The PSQA gamma passing rate was 96.2% for 3%, 3 mm, and 85.3% for 2%, 2 mm. The rate depended on the treatment site. For example, the 3%, 3 mm passing rate was 95% for head and neck plans, vs 100% for prostate plans. The passing rates of multi- vs. single-field optimization plans did not significantly differ. However, the rate for fields with range shifters was 94.8±0.6%, vs 99.0±0.6% for those without (p = 0.002). Longitudinal dose gradients caused most of the low scores. Overestimation of the calculated dose proximal to the spread-out Bragg peak (SOBP) caused many of the others. Conclusion: The planned and delivered doses consistently agreed within tolerance levels. Minor dose modeling deficiencies remain proximal to the SOBP. The 3% dose tolerance, 3 mm DTA, with 90% pixel passing rate is a reasonable action level for 2D gamma comparisons.

60 APPLIED LIFE SCIENCES↗

Probing late-stage hadronic interactions at high baryon density via $K^{⁎0}$ production in the RHIC beam energy scan program

A precision measurement of the $K^{⁎0}$ meson yield is reported in Au+Au collisions at $\sqrt{s_{NN}}$ = 7.7, 11.5, 14.6, 19.6, and 27 GeV using the high-statistics data sample collected by the STAR experiment during the Beam Energy Scan II (BES-II) program at RHIC. The transeverse momentum (p T )-integrated yield ratios $\large{(}K^{⁎0} + \overline{K^{⁎0}}\large{)}/(K^+ + K^{-})$ in central collisions show a suppression relative to peripheral collisions at the (1.7–3.6) σ level, while a thermal model without final-stage rescattering overpredicts this ratio with a deviation of (6.9–8.2) σ. These results indicate a loss of the measured $K^{⁎0}$ signal in central collisions due to re-scattering of its hadronic decay products in the hadronic phase. The p T -integrated yield of charged kaons exhibits an approximate scaling with charged-particle multiplicity, independent of collision energy and system size. A similar trend is observed for the short-lived $K^{⁎0}$ resonance, although significant deviations emerge at lower energies. At BES energies, the $K^{⁎0}/K$ ratio shows stronger suppression than at the highest RHIC and LHC energies within a given multiplicity bin, particularly in central and mid-central collisions. This behavior is consistent with changes in the effective hadronic interaction cross section and is supported by transport model calculations, which indicate dominant meson–baryon interactions at lower energies and meson–meson interactions at higher energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scanning Mobility Particle Sizer (SMPS)-Aerodynamic Particle Sizer (APS) Merged Size Distribution (mergedsmpsaps) Value-Added Product Report

Aerosol particles influence the Earth’s radiation balance directly by absorbing and scattering light and indirectly by influencing cloud formation, properties, and lifetimes. Measurements of aerosol particle optical properties, mass loading, size distributions, microphysical properties, cloud formation properties, and chemical composition are important for understanding the aerosol life cycle and for validating earth system models that predict these quantities. The Atmospheric Radiation Measurement (ARM) user facility’s Aerosol Observing System (AOS) is a highly instrumented platform designed to house instruments that measure many of these aerosol properties in situ. Currently, ARM operates at least four different instruments that measure a portion of the ambient aerosol size distribution. Most users are interested in the entire size distribution or a portion of the size distribution that extends across the measurement range of multiple instruments. However, merging these distributions is not trivial as the instruments employ different measurement principals and, in most cases, report data as a function of different representations of the aerosol diameter.

54 ENVIRONMENTAL SCIENCES↗

Electrode structures in diode-type cadmium telluride detectors: Field emission scanning electron microscopy and energy-dispersive x-ray microanalysis

The structures of the interface regions between CdTe crystal and electrodes in diode-type CdTe x-ray detectors with a layout of In(anode)/CdTe/Pt(cathode) are reported. The structures have been investigated by field emission scanning electron microscopy and energy-dispersive x-ray microanalysis. The investigation has revealed that the structures are complicated. The anode-side interface is a contact between In{sub 1-x}Te{sub x} alloys and CdTe crystal. The cathode side is a structure of Pt/(Te-rich phase)/CdTe. These findings suggest that the complicated structures in the interface regions are a possible cause for the polarization phenomenon observed in the diode-type CdTe detectors.

36 MATERIALS SCIENCE↗

Portable Vibro-acoustic Testing System for In Situ Microstructure Characterization and Metrology

Portable Vibro-acoustic Testing System for In situ Microstructure Characterization and Metrology James A. Smith, Corrie I. Nichol Idaho National Laboratory, Idaho Falls ID Mostafa Fatemi, Mayo Clinic, Rochester MN There is a need in research reactors like the INL to inspect irradiated materials and structures. The goal of this work is to develop a portable scanning infrastructure for a material characterization technique called vibro-acoustography (VA) that has been developed by INL [1] for nuclear applications to characterize fuel, cladding materials, and structures. The proposed VA technology is based on ultrasound and acoustic waves; however, it provides information beyond what is available from the traditional ultrasound techniques and can expand the knowledge on nuclear material characterization and microstructure evolution. VA is a three-dimensional (3D) imaging modality based on ultrasound-stimulated acoustic emission. VA uses the force caused by the beating of two frequencies to generate an acoustic emission signal. Due to absorption or reflection, the energy density in the object at an acoustic focal point changes to produce a “radiation force.” This force locally vibrates the object, which results in an acoustic field that depends on the characteristics of the object at that point. This acoustic field is detected for every point in the object; the resulting data is used to make an image of the object’s mechanical properties. This technology is fundamentally different from traditional ultrasound imaging. More specifically, VA is: (a) based on the “radiation force,” a nonlinear phenomenon in sound propagation, and (b) sensitive to both high and low frequency dynamic responses of the object. The combination of these two response types provides information about characteristics of the object beyond what is possible by traditional ultrasound imaging. High spatial resolution is achieved, since the radiation force is localized to the focal point of the ultrasound beam. Low-frequency information, which is a representative of structural characteristics, is gained through the radiation force mechanism at a low (beat) frequency. This paper will report on the development of a portable scanning that can be set up to characterize materials and component in open water reactors and canals in situ. We will show some initial laboratory results of images generated by vibro-acoustics of surrogate fuel plates and graphite structures and discus the design of the portable system. 1. Smith, J. A., and Kunerth, D. C., “Vibro-acoustic Sensors for Materials Characterization and Related Methods and Systems,” Patent Application 13226280, 09/06/2011.

36 MATERIALS SCIENCE↗

Engineered Barrier System R&D and International Collaborations – LANL (FY20): Spent Fuel and Waste Disposition

The United States Department of Energy’s Spent Fuel and Waste Disposition (SFWD) program is investigating the design and safety function of generic nuclear geologic repositories in a variety of geologic settings (salt, argillite, and crystalline rock). Different configurations and loadings of spent nuclear fuel and waste within disposal canisters are also being investigated, some of which have the potential to generate repository temperatures higher than previously considered (i.e., temperatures >100ºC) by foreign and domestic concepts. This report expands on engineered barrier material stability in a high temperature crystalline rock repository through high temperature hydrothermal experiments. Experiments were designed to develop engineered barrier system (EBS) concepts in a hightemperature crystalline environment in 1) bentonite-Grimsel Granodiorite interactions, 2) bentonite-cement reactions, and 3) interaction between waste canister materials and bentonite. Experiment results are applied to understanding long-term repository performance in terms of radionuclide isolation. One hydrothermal experiment was completed in the rocking autoclaves at LANL in FY-20: IEBS-6 (Grimsel Granodiorite + Wyoming bentonite + cured ordinary Portland cement + Grimsel Granodiorite synthetic groundwater, 250ºC/150 bar, 8 weeks). Several other experiments were planned but were delayed due to the COVID-19 pause in laboratory work. In addition, some characterization of the reaction products of experiments conducted in FY-20 was prevented by COVID-19. Mineral phase chemistry was not measured via electron microprobe analyses for IEBS-6. Quantitative X-ray diffraction results from IEBS-6 and HBT-1 were not completed. The missing analyses and discussion of the results will be included in next year’s report. New characterization that was completed includes scanning electron microscopy of reaction products from IEBS-6, quantitative X-ray diffraction results are presented from IEBS-1 through IBES-5, preliminary scanning electron microscope images and chemical analyses for IEBS-6, X-ray diffraction of the clay fraction from all experiments, measurement/imaging of mineral growth on the surface of steel coupons. Major observations pertaining to bentonite stability in a Grimsel Granodiorite environment include the stability of Na-montmorillonite at 250°C, the formation of trace CSH phases, and the formation of bentonite colloids on experiment cooling. The addition of a cured chip of Portland cement to the bentonite-Grimsel system results in slightly higher pH values and the formation of diverse secondary mineral phases that were not observed in the previous experiments (e.g., analcime, garronite, CSH phases). The new characterization efforts related to the interaction of stainless-steel coupons and bentonite clay focused on thickness and mineralogy of phases that formed at the steel surface. In Wyoming bentonite + Grimsel Granodiorite systems, newly formed minerals at the bentonitesteel coupon interface included alteration of the outermost steel edge to Fe,Cr-oxide phases, followed by Fe-rich phyllosilicates (Fe-saponite, chlorite) and interbedded Fe,Cr,Ni-sulfide phases (pentlandite). Hydrothermal experiments were completed to assess uranium-carbonate complexation at conditions relevant to high-temperature disposal. Autoclave solubility experiments were conducted at 150 to 250ºC with a range of carbonate and uranium concentrations. The experiment results were characterized via situ UV-Visible spectroscopy and synchrotron-based in situ XAS techniques. Results show a significant decrease in the stability of uranyl-carbonate complexes at temperatures above 100ºC along with the precipitation of uranium oxides. Further, at T > 200ºC, results show that uranyl-hydroxyl complexes control solubility of uranium instead of the previously predicted uranyl-carbonate species. These results are significant for understanding the mobility of uranium in the EBS, which will likely contain carbonate-rich fluids. International research efforts focused on three main areas: 1) participation in international conferences, 2) building collaborations with foreign repository programs, and 3) the initiation of an experimental program to complement the full-scale HotBENT test at the Grimsel test site. This experiment included Wyoming bentonite + low carbon steel + Grimsel Granodiorite synthetic groundwater and was run at the planned maximum temperature of the HotBENT test (200°C). Complete characterization of reaction products was hindered by disruptions to laboratory work but will be reported in the next FY. The experimental results obtained in FY-20 continue to document the wide-ranging effects of bulk composition and pressure-temperature conditions in the mineralogical and geochemical evolution of a high-temperature repository environment. Concepts developed will be used to inform models of long-term material stability in a generic crystalline rock-hosted repository.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Dose-Rate Brachytherapy in the Management of Operable Rectal Cancer: A Systematic Review

Purpose: To evaluate the role of high-dose-rate endorectal brachytherapy (HDREBT) in the preoperative and definitive management of operable rectal cancer in terms of clinical outcomes and toxicities using a systematic review. Methods and Materials: A review of published articles from January 1990 to December 2016 was conducted using the PubMed, Embase, and Scopus databases using the search terms “rectal” or “rectum” in combination with “brachytherapy,” “high dose rate,” “HDR,” and “endorectal.” Additional publications were identified by scanning references. Only studies published in English reporting clinical outcomes with ≥30 patients treated with HDREBT were included. Results: The search identified 1688 articles, of which 22 met our inclusion criteria. Twelve studies were included in this systematic review. Following preoperative HDREBT with chemoradiation therapy (CRT), the pathologic complete response (pCR) rate ranged between 18% and 31% (weighted mean rate, 22.2%); R0 resection rate, between 80% and 99% (weighted mean rate, 95.5%); and sphincter-preservation rate, between 29% and 54% (weighted mean rate, 46.4%). The weighted mean 2-year progression-free survival and overall survival (OS) rates were 68.1% and 81.5%, respectively. After preoperative HDREBT alone, the pCR rate ranged between 10.4% and 27% (weighted mean rate, 23.8%), the R0 rate was 96.5% (1 study), and the sphincter-preservation rate ranged between 53.8% and 75.8% (weighted mean rate, 59.4%). The weighted mean 5-year progression-free survival and OS rates were 66.6% and 70.8%, respectively. There was only 1 study of HDREBT for nonsurgical management of rectal cancer, which reported a 2-year OS rate of 100%. Conclusions: Preoperative HDREBT either alone or in combination with CRT may result in a better pCR but may not necessarily translate into better survival, which is similar to outcomes seen following preoperative CRT alone. There were significant variations across studies in terms of patient selection, treatment approaches, and evaluation of clinical outcomes, suggesting the need for an international consensus on the dosimetric parameters and techniques of HDREBT, timing and methods of response assessment, definitions and assessment of toxicities, and optimal timing of surgery before further prospective studies. Future studies should include evaluation of the role of HDREBT in the nonsurgical curative treatment of screen-detected early cancers and organ preservation in lower rectal cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗