Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample integrity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Initial Benchmarking of the Liquid Sampling-Atmospheric Pressure Glow Discharge-Orbitrap System Against Traditional Atomic Mass Spectrometry Techniques for Nuclear Applications

The integration of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ion source with Orbitrap mass spectrometers has resulted in new opportunities in the field of isotope ratio mass spectrometry. In a field that has been dominated by thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICP-MS) on quadrupole and scanning-mode sector field analyzer platforms for highly accurate and precise measurements, the LS-APGD-Orbitrap system offers a benchtop instrument capable of meeting the rigorous International Target Values for measurement uncertainty for uranium (U). In order to benchmark the LS-APGD-Orbitrap, a series of U certified reference materials with increasing {sup 235}U isotopic composition were analyzed. By using U samples ranging in enrichment from 1 to 80%, the ability of the system to measure isotope ratios over a wide range is demonstrated. This analysis represents the first time that the LS-APGD-Orbitrap system has been used to analyze highly enriched U samples, allowing for the measurement of each of the U isotopes, including {sup 234}U and {sup 236}U-related species, which had not been achieved previously. Ultimately, the LS-APGD-Orbitrap system was able to measure CRM U-800 (assayed as {sup 235}U / {sup 238}U = 4.265622) as 4.266922, with a combined uncertainty, (u{sub c}), of 0.040%. These results are compared to those obtained using traditional elemental mass spectrometers including TIMS and ICP-MS-based instruments. The effectiveness of the LS-APGD-Orbitrap MS system for measuring U isotopes shows excellent promise in nuclear forensics, safeguards, and other nuclear weapon-based applications. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of an Atomic Force Microscope in a Beamline Sample Environment

We developed and optimised an optics-free Atomic Force Microscope (AFM) that can be directly installed on most of the synchrotron radiation end-stations. The combination of Scanning Probe Microscopies with X-ray microbeams adds new possibilities to the variety of synchrotron radiation techniques. The instrument can be used for atomic force imaging of the investigated sample or to locally measure the X-ray absorption or diffraction, or it can also be used to mechanically interact with the sample while simultaneously taking spectroscopy or diffraction measurements. The local character of these measurements is intrinsically linked with the use of the Atomic Force Microscope tip. It is the sharpness of the tip that gives the opportunity to measure the photons flux impinging on it giving beam position monitor features, or allows to locally measure the absorption coefficient or the shape of the diffraction pattern. As an example of the possibilities opened by the instrument we will show diffraction measurements performed on a Ge/Si island while being indented with the AFM tip providing local measure of the Young coefficient. Three ESRF beamlines are going to be equipped with this new instrument.

43 PARTICLE ACCELERATORS↗

CHANDRA LOCALIZATIONS AND SPECTRA OF INTEGRAL SOURCES IN THE GALACTIC PLANE: THE CYCLE 9 SAMPLE

We report on 0.3-10 keV X-ray observations by the Chandra X-ray Observatory of the fields of 22 sources that were discovered as hard X-ray (20-100 keV) sources by the International Gamma-Ray Astrophysics Satellite ('IGR' sources). The observations were made during Chandra's 9th observing cycle, and their purpose is to localize the sources and to measure their soft X-ray spectra in order to determine the nature of the sources. We find very likely Chandra counterparts for 18 of the 22 sources. We discuss the implications for each source, considering previous results and new optical or infrared identifications, and we identify or suggest identifications for the nature of 16 of the sources. Two of the sources, IGR J14003-6326 and IGR J17448-3232, are extended on arcminute scales. We identify the former as a pulsar wind nebula with a surrounding supernova remnant (SNR) and the latter as an SNR. In the group of 242 IGR sources, there is only one other source that has previously been identified as an SNR. Seven of the sources are definite or candidate high-mass X-ray binaries (HMXBs). We confirm a previous identification of IGR J14331-6112 as an HMXB, and based on combinations of hard X-ray spectra, inferred distances and X-ray luminosities, and/or column density variations, we suggest that IGR J17404-3655, IGR J16287-5021, IGR J17354-3255, IGR J17507-2647, IGR J17586-2129, and IGR J13186-6257 are candidate HMXBs. Our results indicate or confirm that IGR J19267+1325, IGR J18173-2509, and IGR J18308-1232 are cataclysmic variables (CVs), and we suggest that IGR J15529-5029 may also be a CV. We confirm that IGR J14471-6414 is an active galactic nucleus (AGN), and we also suggest that IGR J19443+2117 and IGR J18485-0047 may be AGNs. Finally, we found Chandra counterparts for IGR J11098-6457 and IGR J18134-1636, but more information is required to determine the nature of these two sources.

99 GENERAL AND MISCELLANEOUS↗

Metagenome-assembled genomes measured at 3 depths during snowmelt period in East River, CO (March, May, and June, September 2017)

Snowmelt is a critical biogeochemical period that accounts for large nitrogen (N) export events from high-elevation watersheds. Soil microbial populations bloom and immobilize N during snowmelt, yet the population size crashes in spring, which releases a pulse of soil N. We sought to discover the N sources fueling this microbial bloom and determine the fate of N following microbial die-off. Here, focusing on the snowmelt period within a headwater catchment of the Upper Colorado River Basin (East River, CO), we deployed strain-resolved metagenomics to identify the metabolic pathways and processes that mobilize soil N during and after snowmelt. Soil metagenome samples were taken from 6 snowpits from 3 depths (0-5cm, 5-15cm, >15cm) at 4 time points during snowmelt period (March 2017, May 2017, and June 2017, September 2017) generating 48 metagenomes. We reconstructed 474 metagenome-assembled genomes (MAGs) across all metagenomes.All 48 metagenomes were sequenced at JGI and raw data can be found under JGI (Joint Genome Institute) GOLD Study Gs0135149. Metagenome assemblies from IMG under the same study were used for genome binning. This dataset (1) a zip file of 474 MAGs (as fasta files, Gs0135149_bins_tar.gz), (2) sample metadata file with sample IGSNs (International Generic Sample Numbers) (samples.csv), (3) bounding box coordinates for the sampled locations (Gs0135149.kml), (4) metagenome metadata file listing IMG/M (Integrated Microbial Genomes/Metagenomes) metagenome accessions linking samples to metagenomes (metagenomes.csv), (5) location metadata file (locations.csv), (6) file-level metadata file (flmd.csv) and (7) data dictionary (dd.csv) file.This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Nevada Higher Education Benefits from US Department of Energy (DOE) Environmental Management (EM) Nevada Program's Transfer of Geologic Samples - 20442

The Nevada National Security Site (NNSS), formerly the Nevada Test Site, was the location of 100 historic atmospheric and 828 historic underground nuclear tests from 1951 to 1992. Related to this historic nuclear testing, geologic and hydrologic studies of the site were conducted utilizing the skills and the expertise of the U.S. Geological Survey (USGS) and national laboratories (Los Alamos National Laboratory, Lawrence Livermore National Laboratory), who were principal in leading the development of weapons and were responsible for specific underground testing programs. The subsurface samples and technical/scientific data associated with NNSS geologic studies (past and present) are preserved and stored at the USGS Mercury Core Library and Data Center located at the NNSS. Currently, the facility stores over 2,000,000 linear feet of cores and cuttings from more than 2,600 drill holes that can be accessed for study. Most of the samples and historic geologic work was focused directly on subsurface geologic settings that relate directly to historic underground nuclear testing. Since 1992, the United States has observed a unilateral moratorium on full-scale nuclear testing, and the U.S. Department of Energy (DOE) Environmental Management (EM) Nevada Program is now responsible for hydrogeologic characterization of the potential impacts to the natural groundwater systems that may have resulted from historic underground nuclear tests. As part of this effort, the EM Nevada Program Underground Test Area (UGTA) Activity has drilled and completed over 58 deep (2,000 - 7,000 ft.) characterization wells, totaling in excess of 170,000 linear feet of cuttings and core samples. Cutting samples were collected as triplicate samples for each respective depth interval, to account for potential later nondestructive/destructive analysis and to preserve samples for regulatory purposes. Recently, it was recognized by the EM Nevada Program that opportunities may exist to reduce the cost and floor space required for the storage of geologic samples at the Mercury Core Library without impacting the integrity and representative nature of the samples necessary for project execution. An initiative was sponsored by EM Nevada Program to evaluate several options: 1) disposal of a portion of cuttings and cores in a land fill setting; 2) reduction in sample volume through skeletonizing core and cuttings from wells to a representative but much smaller number of samples; and 3) solicit potential interest in the academic community where other geoscientists could freely access the samples for studies. The Nevada state university system through the Nevada Bureau of Mines and Geology responded positively to the opportunity to receive these NNSS samples from the EM Nevada Program. In June 2019, approximately 17,000 geologic samples, representing greater than 170,000 linear feet of drilling and weighing over 20,000 pounds, were shipped from the NNSS to the Great Basin Science Sample and Records Library located in Reno, Nevada. The benefits resulting from this transfer were realized by the EM Nevada Program in terms of cost and space savings for geologic sample storage at the NNSS. The transfer did not impact the EM Nevada Program mission as access to representative geologic samples for regulatory and scientific purposes was preserved. Moreover, the Nevada Bureau of Mines and Geology acquired a significant resource of subsurface geologic samples and supporting technical data to support academic and scientific studies in a complex volcanic setting in southwest Nevada. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of the cross section for W-boson production in association with jets in ppbar collisions at s**(1/2) = 1.96-TeV

We present a measurement of the cross section for W-boson production in association with jets in p{bar p} collisions at {radical}s = 1.96 TeV. The analysis uses a data sample corresponding to an integrated luminosity of 320 pb{sup -1} collected with the CDF II detector. W bosons are identified in their electron decay channel and jets are reconstructed using a cone algorithm. For each W + {ge} n-jet sample (n = 1-4) we measure {sigma}(p{bar p} {yields} W + {ge} n-jet) x {Beta}(W {yields} e{nu}) with respect to the transverse energy E{sub T} of the nth-highest E{sub T} jet above 20 GeV, for a restricted W {yields} e{nu} decay phase space. The cross sections, corrected for all detector effects, can be directly compared to particle level W + jet(s) predictions. We present here comparisons to leading order and next-to-leading order predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diagnostic/drug delivery "sense-respond" devices, systems, and uses thereof

The present invention is directed to devices, systems, and methods for detecting and/or monitoring one or more markers in a sample. In particular, such devices integrate a plurality of hollow needles configured to extract or obtain a fluid sample from a subject, as well as transducers to detect a marker of interest.

47 OTHER INSTRUMENTATION↗

Measurement of the Production Cross Section for Pairs of Isolated Photons in pp collisions at sqrt(s) = 7 TeV

The integrated and differential cross sections for the production of pairs of isolated photons is measured in proton-proton collisions at a centre-of-mass energy of 7 TeV with the CMS detector at the LHC. A data sample corresponding to an integrated luminosity of 36 inverse picobarns is analysed. A next-to-leading-order perturbative QCD calculation is compared to the measurements. A discrepancy is observed for regions of the phase space where the two photons have an azimuthal angle difference, $\Delta(\phi)$, less than approximately 2.8.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of flask vibration time on casting integrity, Surface Penetration and Coating Inclusion in lost foam casting of Al-Si Alloy

The paper presents the result of an experimental investigation conducted on medium aluminum silicon alloy casting- LM6, using no-vacuum assisted lost foam casting process. The study is directed for establishing the relationship between the flask vibrations times developed for molded sample on the casting integrity, surface penetration and coating inclusion defects of the casting. Four different flask vibration times namely 180, 120, 90 and 60 sec. were investigated. The casting integrity was investigated in terms of fulfilling in all portions and edges. The surface penetration was measured using optical microscope whilst image analyzer was used to quantify the percentage of coating inclusion in the casting. The results show that vibration time has significant influence on the fulfilling as well as the internal integrity of the lost foam casting. It was found that the lower vibration time produced comparatively sound casing.

36 MATERIALS SCIENCE↗

Optimization-Based Approach for Joint X-Ray Fluorescence and Transmission Tomographic Inversion

Fluorescence tomographic reconstruction, based on the detection of photons coming from fluorescent emission, can be used for revealing the internal elemental composition of a sample. On the other hand, conventional X-ray transmission tomography can be used for reconstructing the spatial distribution of the absorption coefficient inside a sample. In this work, we integrate both X-ray fluorescence and X-ray transmission data modalities and formulate a nonlinear optimization-based approach for reconstruction of the elemental composition of a given object. This model provides a simultaneous reconstruction of both the quantitative spatial distribution of all elements and the absorption effect in the sample. Mathematically speaking, we show that compared with the single-modality inversion (i.e., the X-ray transmission or fluorescence alone), the joint inversion provides a better-posed problem, which implies a better recovery. Therefore, the challenges in X-ray fluorescence tomography arising mainly from the effects of self-absorption in the sample are partially mitigated. The use of this technique is demonstrated on the reconstruction of several synthetic samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Galaxy cluster scaling relations between Bolocam Sunyaev–Zel’dovich effect and Chandra X-ray measurements

We present scaling relations between the integrated Sunyaev–Zel’dovich effect (SZE) signal, Y{sub SZ}, its X-ray analogue, Y{sub X} ≡ M{sub gas} T{sub X}, and total mass, M{sub tot}, for the 45 galaxy clusters in the Bolocam X-ray SZ (BOXSZ) sample. All parameters are integrated within r{sub 2500}. Y{sub 2500} values are measured using SZE data collected with Bolocam, operating at 140 GHz at the Caltech Submillimeter Observatory. The temperature, T{sub X}, and mass, M{sub gas,2500}, of the intracluster medium are determined using X-ray data collected with Chandra, and M{sub tot} is derived from M{sub gas} assuming a constant gas mass fraction. Our analysis accounts for several potential sources of bias, including selection effects, contamination from radio point sources, and the loss of SZE signal due to noise filtering and beam-smoothing effects. We measure the Y{sub 2500}–Y{sub X} scaling to have a power-law index of 0.84 ± 0.07, and a fractional intrinsic scatter in Y{sub 2500} of (21±7)% at fixed Y{sub X}, both of which are consistent with previous analyses. We also measure the scaling between Y{sub 2500} and M{sub 2500}, finding a power-law index of 1.06 ± 0.12 and a fractional intrinsic scatter in Y{sub 2500} at fixed mass of (25±9)%. While recent SZE scaling relations using X-ray mass proxies have found power-law indices consistent with the self-similar prediction of 5/3, our measurement stands apart by differing from the self-similar prediction by approximately 5σ. Given the good agreement between the measured Y{sub 2500}–Y{sub X} scalings, much of this discrepancy appears to be caused by differences in the calibration of the X-ray mass proxies adopted for each particular analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

A systematic approach to resolve high impedance of multifunctional energy storage composites

Previous work has proposed and characterized the structural and electrical performance of Multifunctional Energy Storage Composite (MESC) structures: structural elements with embedded lithium-ion batteries which were developed by the Structures and Composite Laboratory (SACL) at Stanford University. This work conducts a comprehensive parametric study over the design variables in the manufacturing process to determine the root cause of increased DC impedance compared to commercial pouch cell batteries. Several MESC samples were assembled under various controlled environmental temperatures and pressures. The samples underwent Hybrid Peak Pulse Characterization (HPPC) to approximate the DC impedance as a function of state of charge (SOC). Failure limits of the battery with respect to assembly temperature and pressure were tested, and an MESC manufacturing simulation model was constructed in Abaqus to validate the manufacturing limits. Samples assembled without enough temperature or pressure failed due to a lack of structural integrity or hermetic seal. Conversely, samples which underwent elevated temperatures and pressures resulted in high DC impedance due to nonuniform electrolyte wetting. This work resolves the primary concern of MESC by achieving comparable DC impedance to commercial pouch cells of the same chemistry and testing procedure.

25 ENERGY STORAGE↗

Properties of Exotic Charmonium-like States at CDF

We report the recent evidence for a new narrow structure, Y (4140), decaying to the J/{psi}{phi} final state, in exclusive B{sup +} {yields} J/{psi}{phi}K{sup +} decays in a data sample corresponding to an integrated luminosity of 2.7 fb{sup -1} collected at the CDF II detector. This narrow structure with its mass well above open charm pairs is unlikely to be a candidate for a conventional charmonium state. From a study of the X(3872) mass and width based on the world's largest sample of X(3872) {yields} J/{psi}{pi}{sup +}{pi}{sup -} decays, we find that our X(3872) signal is consistent with a single state, and leads to the most precise measurement of the X(3872) mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An information diffusion technique to assess integrated hazard risks

An integrated risk is a scene in the future associated with some adverse incident caused by multiple hazards. An integrated probability risk is the expected value of disaster. Due to the difficulty of assessing an integrated probability risk with a small sample, weighting methods and copulas are employed to avoid this obstacle. To resolve the problem, in this paper, we develop the information diffusion technique to construct a joint probability distribution and a vulnerability surface. Then, an integrated risk can be directly assessed by using a small sample. A case of an integrated risk caused by flood and earthquake is given to show how the suggested technique is used to assess the integrated risk of annual property loss.

58 GEOSCIENCES↗

XAMPS Detectors Readout ASIC for LCLS

An ASIC for the readout of signals from X-ray Active Matrix Pixel Sensor (XAMPS) detectors to be used at the Linac Coherent Light Source (LCLS) is presented. The X-ray Pump Probe (XPP) instrument, for which the ASIC has been designed, requires a large input dynamic range on the order of 104 photons at 8 keV with a resolution of half a photon FWHM. Due to the size of the pixel and the length of the readout line, large input capacitance is expected, leading to stringent requirement on the noise optimization. Furthermore, the large number of pixels needed for a good position resolution and the fixed LCLS beam period impose limitations on the time available for the single pixel readout. Considering the periodic nature of the LCLS beam, the ASIC developed for this application is a time-variant system providing low-noise charge integration, filtering and correlated double sampling. In order to cope with the large input dynamic range a charge pump scheme implementing a zero-balance measurement method has been introduced. It provides an on chip 3-bit coarse digital conversion of the integrated charge. The residual charge is sampled using correlated double sampling into analog memory and measured with the required resolution. The first 64 channel prototype of the ASIC has been fabricated in TSMC CMOS 0.25 {micro}m technology. In this paper, the ASIC architecture and performances are presented.

43 PARTICLE ACCELERATORS↗

Two-dimensional Point Shifting for Improving the Quantitative Testing with Null Screens

In order to reduce the numeric errors accumulated during the integration procedure, a greater density of sampling is obtained reducing the spacing between spots in the integration paths selected, for this, a new design of the null screen is proposed, these design allow a two-dimensional point shifting (angular and radial) of the spots on the image plane by only the angular movement of the test surface. A screen for producing an image with spots ordered in a radial arrangement is used. Experimental results for the test of fast convex aspheric surface (F = 0.22) are shown.