Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference frames”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Tracking f(R) cosmology

Metric f(R) gravity theories are conformally equivalent to models of quintessence in which matter is coupled to dark energy. We derive a condition for a stable tracker solution for metric f(R) gravity in the Einstein frame. We find that tracker solutions with -0.361<{omega}{sub {phi}}<1 exist if 0<{gamma}<0.217 and (d/dt)lnf{sup '}(R-tilde)>0, where {gamma}=(V{sub {phi}}{sub {phi}}V/V{sub {phi}}{sup 2}) is a dimensionless function, {omega}{sub {phi}} is the equation of state parameter of the scalar field, and R-tilde refers to the Jordan frame's curvature scalar. Also, we show that there exists f(R-tilde) gravity models which have tracking behavior in the Einstein frame and so the curvature of space-time is decreasing with time while they lead to the solutions in the Jordan frame that the curvature of space-time can be increasing with time.

99 GENERAL AND MISCELLANEOUS↗

THE SPECTRALLY RESOLVED Lyα EMISSION OF THREE Lyα-SELECTED FIELD GALAXIES AT z ∼ 2.4 FROM THE HETDEX PILOT SURVEY

We present new results on the spectrally resolved Lyα emission of three Lyα-emitting field galaxies at z ∼ 2.4 with high Lyα equivalent width (>100 Å) and Lyα luminosity (∼10{sup 43} erg s{sup –1}). At 120 km s{sup –1} (FWHM) spectral resolution, the prominent double-peaked Lyα profile straddles the systemic velocity, where the velocity zero point is determined from spectroscopy of the galaxies' rest-frame optical nebular emission lines. The average velocity offset from systemic of the stronger redshifted emission component for our sample is 176 km s{sup –1} while the average total separation between the redshifted and main blueshifted emission components is 380 km s{sup –1}. These measurements are a factor of ∼2 smaller than for UV-continuum-selected galaxies that show Lyα in emission with lower Lyα equivalent widths. We compare our Lyα spectra to the predicted line profiles of a spherical 'expanding shell' Lyα radiative transfer grid that models large-scale galaxy outflows. Specifically, blueward of the systemic velocity where two galaxies show a weak, highly blueshifted (by ∼1000 km s{sup –1}) tertiary emission peak, the model line profiles are a relatively poor representation of the observed spectra. Since the neutral gas column density has a dominant influence over the shape of the Lyα line profile, we caution against equating the observed Lyα velocity offset with a physical outflow velocity, especially at lower spectral resolution where the unresolved Lyα velocity offset is a convoluted function of several degenerate parameters. Referring to rest-frame ultraviolet and optical Hubble Space Telescope imaging, we find that galaxy-galaxy interactions may play an important role in inducing a starburst that results in copious Lyα emission as well as perturbing the gas distribution and velocity field, both of which have strong influence over the Lyα emission line profile.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-D-BRD-02: In Memoriam of Bengt Bjarngard: SBRT II: Small Field Dosimetry - TG155

Specialized radiation treatment such as SRS/SRT. SBRT, IMRT, VMAT, Tomotherapy, CyberKnife and Gamma Knife use small fields or combination of small fields where dosimetry is challenging and uncertain due to non-equilibrium conditions such as longitudinal and lateral disequilibrium. Additionally the primary photon fluence is greatly affected by the obstruction of the source size by the jaws creating a large dose gradient across the field. Electronic equilibrium is a phenomenon associated with the range of secondary particles which depend on the beam energy, photon spectrum and the composition of the medium. Additionally, the finite size of detectors creates volume averaging and fluence perturbations especially in small fields. The IAEA/AAPM has provided a frame work for non-compliant reference dosimetry in small fields1. The AAPM TG-1552 has adopted this frame work to provide guidelines in relative dosimetry. This course provides the insight of TG-155 that defines small field, provides recommendations for suitable detectors and associated correction factors to convert reading to dose. Recommendations of a good working practice for relative dosimetry measurements (PDD, TMR, output factor, etc.) and dose calculations based on the new formulation is are elaborated. It also discusses beam modeling and dose calculations as a critical step in clinical utilization of small field radiotherapy. Small errors in beam data, approximations in dose algorithms, or misaligned of detectors and field settings can propagate into large errors in planned and delivered dose. The modeling and treatment planning aspects of small field dosimetry are reviewed with emphasis on the most critical parts for ensuring accurate and safe radiation therapy. Discussion on k(fmsr, fclin) for commercially available detectors are also provided.1 P. Alfonso, P. Andreo, R. Capote, M. S. Huq, W. Kilby, P. Kjall, T. R. Mackie, H. Palmans, K. Rosser, J. Seuntjens, W. Ullrich and S. Vatnitsky, “A new formalism for reference dosimetry of small and nonstandard fields,” Med Phys 35, 5179–5186 (2008).2 I. J. Das, P. Francescon, A. Ahnesjo, M. M. Aspradakis, C. W. Cheng, G. X. Ding, G. S. Ibbott, M. Oldham, M. S. Huq, C. S. Reft and S. O.A., “Task Group 155 report: Small fields and non-equilibrium condition photon beam dosimetry,” Med Phys (under review). Learning Objectives: Physics of cavity theory for non-equilibrium condition and definition of small fields Description of absolute and relative dosimetry in the context of TG-155 Choice of detector in small field dosimetry, perturbations and corrections (K(fmsr, fclin)) for accurate dosimetry Understand the advantages and limitations of commercially available detectors for small field dosimetry.

60 APPLIED LIFE SCIENCES↗

Coriolis forces modify magnetostatic ponderomotive potentials

It is possible to produce a ponderomotive effect in a plasma system without time-varying fields, if the plasma flows over spatial oscillations in the field. This can be achieved by superimposing a spatially oscillatory perturbation on a guide field, then setting up an electric field perpendicular to the guide field to drive flow over the perturbation. However, subtle distinctions in the structure of the resulting electric field can entirely change the behavior of the resulting ponderomotive force. Previous work has shown that, in slab models, these distinctions can be explained in terms of the polarization of the effective wave that appears in the co-moving frame. Here, we consider what happens to this picture in a cylindrical system, where the transformation to the co-moving (rotating) frame is not inertial. It turns out that the non-inertial nature of this frame transformation can lead to counterintuitive behavior, partly due to the appearance of parallel (magnetic-field-aligned) electric fields in the rotating frame even in cases where none existed in the laboratory frame. Apart from the academic interest of this study, the practical impact lies in being better able to anticipate the antenna configuration on the plasma periphery of a cylindrical plasma that will lead to optimal ponderomotive barrier formation in the interior plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Load Inrush Current Mitigation in Islanded Microgrids Powered by Grid-Forming Inverters

Grid-forming inverters in a microgrid may trip due to high inrush current caused by a switched connection of an inductive load, e.g., a relatively large induction motor. The control scheme presented in this article includes virtual inertia control method superimposed on the cascaded controller. This article studies the impact of cascaded control scheme used for grid-forming inverter to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. Experimental tests are performed using the virtual inertia method for generating the reference angle for synchronous frame conversion. The experimental performance and sensitivity of the controller to different controller gain settings for a switched connection of an induction motor are discussed. The cascaded operation significantly mitigates the inrush currents while the inverters can perform a normal operation. The performance of the control method is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented.

Gursoy, Mehmetcan↗

Evaluation of the geometric accuracy of surrogate-based gated VMAT using intrafraction kilovoltage x-ray images

Purpose: To evaluate the geometric accuracy of beam targeting in external surrogate-based gated volumetric modulated arc therapy (VMAT) using kilovoltage (kV) x-ray images acquired during dose delivery. Methods: Gated VMAT treatments were delivered using a Varian TrueBeam STx Linac for both physical phantoms and patients. Multiple gold fiducial markers were implanted near the target. The reference position was created for each implanted marker, representing its correct position at the gating threshold. The gating signal was generated from the RPM system. During the treatment, kV images were acquired immediately before MV beam-on at every breathing cycle, using the on-board imaging system. All implanted markers were detected and their 3D positions were estimated using in-house developed software. The positioning error of a marker is defined as the distance of the marker from its reference position for each frame of the images. The overall error of the system is defined as the average over all markers. For the phantom study, both sinusoidal motion (1D and 3D) and real human respiratory motion was simulated for the target and surrogate. In the baseline case, the two motions were synchronized for the first treatment fraction. To assess the effects of surrogate-target correlation on the geometric accuracy, a phase shift of 5% and 10% between the two motions was introduced. For the patient study, intrafraction kV images of five stereotactic body radiotherapy (SBRT) patients were acquired for one or two fractions. Results: For the phantom study, a high geometric accuracy was achieved in the baseline case (average error: 0.8 mm in the superior-inferior or SI direction). However, the treatment delivery is prone to geometric errors if changes in the target-surrogate relation occur during the treatment: the average error was increased to 2.3 and 4.7 mm for the phase shift of 5% and 10%, respectively. Results obtained with real human respiratory curves show a similar trend. For a target with 3D motion, the technique is able to detect geometric errors in the left-right (LR) and anterior-posterior (AP) directions. For the patient study, the average intrafraction positioning errors are 0.8, 0.9, and 1.4 mm and 95th percentile errors are 1.7, 2.1, and 2.7 mm in the LR, AP, and SI directions, respectively. Conclusions: The correlation between external surrogate and internal target motion is crucial to ensure the geometric accuracy of surrogate-based gating. Real-time guidance based on kV x-ray images overcomes the potential issues in surrogate-based gating and can achieve accurate beam targeting in gated VMAT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of transfer map calculation for electrostatic deflectors in the code COSY INFINITY

The code COSY INFINITY uses a beamline coordinate system with a Frenet–Serret frame relative to the reference particle, and calculates differential algebra-valued transfer maps by integrating the ODEs of motion in the respective vector space over a differential algebra (DA). In our work, we described and performed computation of the DA transfer map of an electrostatic spherical deflector in a laboratory coordinate system using two conventional methods: (1) by integrating the ODEs of motion using a numerical integrator and (2) by computing analytically and in closed form the properties of the respective elliptical orbits from Kepler theory. We compared the resulting transfer maps with (3) the DA transfer map of COSY INFINITY’s built-in electrostatic spherical deflector element ESP and (4) the transfer map of the electrostatic spherical deflector computed using the program GIOS, which uses analytic formulas from a paper1 by Hermann Wollnik regarding second-order aberrations. In addition to the electrostatic spherical deflector, we studied an electrostatic cylindrical deflector, where the Kepler theory is not applicable. We computed the DA transfer map by the ODE integration method (1), and we compared it with the transfer maps by (3) COSY INFINITY’s built-in electrostatic cylindrical deflector element ECL and (4) GIOS. The transfer maps of electrostatic spherical and cylindrical deflectors obtained using the direct calculation methods (1) and (2) are in excellent agreement with those computed using (3) COSY INFINITY. On the other hand, we found a significant discrepancy with (4) the program GIOS.

43 PARTICLE ACCELERATORS↗

A CONVENIENT SOLUTION TO GEOMETRIC DISTORTION AND ITS APPLICATION TO PHOEBE'S OBSERVATIONS

A simple but effective approach is proposed for measuring the geometric distortion of a CCD field of view of a ground-based telescope. For three open clusters (M35, M67, and NGC 2324), 425 CCD frames taken by a 1 m telescope at the Yunnan Observatory are used to test this approach. It is found that the geometric distortion pattern depends strongly on the corresponding filter used. The geometric distortion is then used to correct the pixel positions for Phoebe, the ninth satellite of Saturn, and its reference stars imaged in 220 CCD frames taken by the same telescope. The standard deviation of the (O - C; observed minus computed) residuals of Phoebe is significantly improved after correcting the geometric distortions.

79 ASTRONOMY AND ASTROPHYSICS↗

Early Results from GLASS-JWST. V: The First Rest-frame Optical Size–Luminosity Relation of Galaxies at z > 7

We present the first rest-frame optical size–luminosity relation of galaxies at z > 7, using the NIRCam imaging data obtained by the GLASS James Webb Space Telescope Early Release Science (GLASS-JWST-ERS) program, providing the deepest extragalactic data of the ERS campaign. Our sample consists of 19 photometrically selected bright galaxies with m F444W ≤ 27.8 at 7 < z < 9 and m F444W < 28.2 at z ~ 9–15. We measure the size of the galaxies in five bands, from rest-frame optical (~4800 Å) to the UV (~1600 Å) based on the Sérsic model, and analyse the size–luminosity relation as a function of wavelength. Remarkably, the data quality of the NIRCam imaging is sufficient to probe the half-light radius r e down to ~100 pc at z > 7. Given the limited sample size and magnitude range, we first fix the slope to that observed for larger samples in rest-frame UV using Hubble Space Telescope samples. The median size r 0 at the reference luminosity M = –21 decreases slightly from rest-frame optical (600 ± 80 pc) to UV (450 ± 130 pc). We then refit the size–luminosity relation allowing the slope to vary. The slope is consistent with β ~ 0.2 for all bands except F150W, where we find a marginally steeper slope of β = 0.53 ± 0.15. The steep UV slope is mainly driven by the smallest and faintest galaxies. If confirmed by larger samples, it implies that the UV size–luminosity relation breaks toward the faint end, as suggested by lensing studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Dissociative photoionization of NO across a shape resonance in the XUV range using circularly polarized synchrotron radiation

We report benchmark results for dissociative photoionization (DPI) spectroscopy and dynamics of the NO molecule in the region of the σ* shape resonance in the ionization leading to the NO + (c 3 Π) ionic state. The experimental study combines well characterized extreme ultraviolet (XUV) circularly polarized synchrotron radiation, delivered at the DESIRS beamline (SOLEIL), with ion-electron coincidence 3D momentum spectroscopy. The measured (N + , e) kinetic energy correlation diagrams reported at four discrete photon energies in the extended 23-33 eV energy range allow for resolving the different active DPI reactions and underline the importance of spectrally resolved studies using synchrotron radiation in the context of time-resolved studies where photoionization is induced by broadband XUV attosecond pulses. In the dominant DPI reaction which leads to the NO + (c 3 Π) ionic state, photoionization dynamics across the σ* shape resonance are probed by molecular frame photoelectron angular distributions where the parallel and perpendicular transitions are highlighted, as well as the circular dichroism CDAD(θ e ) in the molecular frame. The latter also constitute benchmark references for molecular polarimetry. The measured dynamical parameters are well described by multichannel Schwinger configuration interaction calculations. Finally, similar results are obtained for the DPI spectroscopy of highly excited NO + electronic states populated in the explored XUV photon energy range.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lorentz invariance of basis tensor gauge theory

Basis tensor gauge theory (BTGT) is a vierbein analog reformulation of ordinary gauge theories in which the vierbein field describes the Wilson line. After a brief review of the BTGT, we clarify the Lorentz group representation properties associated with the variables used for its quantization. In particular, we show that starting from an SO(1,3) representation satisfying the Lorentz-invariant U(1,3) matrix constraints, BTGT introduces a Lorentz frame choice to pick the Abelian group manifold generated by the Cartan subalgebra of U(1,3) for the convenience of quantization even though the theory is frame independent. This freedom to choose a frame can be viewed as an additional symmetry of BTGT that was not emphasized before. We then show how an [Formula: see text] permutation symmetry and a parity symmetry of frame fields natural in BTGT can be used to construct renormalizable gauge theories that introduce frame-dependent fields but remain frame independent perturbatively without any explicit reference to the usual gauge field.

Physics↗

Carbon Capture Approaches for Natural Gas Combined Cycle Systems

This study develops ASPEN PLUS simulation models and cost estimates for Natural Gas Combined Cycle plants with CO2 capture. Three approaches for carbon capture are examined: pre-Adv. Combustion Systems, post-Adv. Combustion Systems and oxy-Adv. Combustion Systems. In pre-Adv. Combustion Systems carbon capture, the carbon in the fuel is converted to CO2 and removed before the Adv. Combustion Systems process, whereas in post-Adv. Combustion Systems, the more dilute CO2 is separated from the flue gas at a lower pressure. Oxy-Adv. Combustion Systems technologies use nearly pure oxygen as the oxidant so that the flue gas consists primarily of CO2 and water vapor. Case results are compared with a reference plant based on an 7F frame Adv. Combustion Systems turbine.

Approaches for Natural Gas Combined Cycle Systems↗

Beam’s-eye-view imaging during non-coplanar lung SBRT

Purpose: Beam’s-eye-view (BEV) imaging with an electronic portal imaging device (EPID) can be performed during lung stereotactic body radiation therapy (SBRT) to monitor the tumor location in real-time. Image quality for each patient and treatment field depends on several factors including the patient anatomy and the gantry and couch angles. The authors investigated the angular dependence of automatic tumor localization during non-coplanar lung SBRT delivery. Methods: All images were acquired at a frame rate of 12 Hz with an amorphous silicon EPID. A previously validated markerless lung tumor localization algorithm was employed with manual localization as the reference. From ten SBRT patients, 12 987 image frames of 123 image sequences acquired at 48 different gantry–couch rotations were analyzed. δ was defined by the position difference of the automatic and manual localization. Results: Regardless of the couch angle, the best tracking performance was found in image sequences with a gantry angle within 20° of 250° (δ = 1.40 mm). Image sequences acquired with gantry angles of 150°, 210°, and 350° also led to good tracking performances with δ = 1.77–2.00 mm. Overall, the couch angle was not correlated with the tracking results. Among all the gantry–couch combinations, image sequences acquired at (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) led to the best tracking results with δ = 1.19–1.82 mm. The worst performing combinations were (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) with δ > 3.5 mm. However, 35% (17/48) of the gantry–couch rotations demonstrated substantial variability in tracking performances between patients. For example, the field angle (θ = 70°, ϕ = 10°) was acquired for five patients. While the tracking errors were ≤1.98 mm for three patients, poor performance was found for the other two patients with δ ≥ 2.18 mm, leading to average tracking error of 2.70 mm. Only one image sequence was acquired for all other gantry–couch rotations (δ = 1.18–10.29 mm). Conclusions: Non-coplanar beams with gantry–couch rotation of (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) have the highest accuracy for BEV lung tumor localization. Additionally, gantry angles of 150°, 210°, 250°, and 350° also offer good tracking performance. The beam geometries (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) are associated with substantial automatic localization errors. Overall, lung tumor visibility and tracking performance were patient dependent for a substantial number of the gantry–couch angle combinations studied.

60 APPLIED LIFE SCIENCES↗

Reconfigurable assembly work station

A reconfigurable autonomous workstation includes a multi-faced superstructure including a horizontally-arranged frame section supported on a plurality of posts. The posts form a plurality of vertical faces arranged between adjacent pairs of the posts, the faces including first and second faces and a power distribution and position reference face. A controllable robotic arm suspends from the rectangular frame section, and a work table fixedly couples to the power distribution and position reference face. A plurality of conveyor tables are fixedly coupled to the work table including a first conveyor table through the first face and a second conveyor table through the second face. A vision system monitors the work table and each of the conveyor tables. A programmable controller monitors signal inputs from the vision system to identify and determine orientation of the component on the first conveyor table and control the robotic arm to execute an assembly task.

42 ENGINEERING↗

Bridging the gap between LCA, LCC and CBA as sustainability assessment tools

Increasing interest in sustainability has led to the development of sustainability assessment tools such as Life Cycle Analysis (LCA), Life Cycle Costing (LCC) and Cost–Benefit Analysis (CBA). Due to methodological disparity of these three tools, conflicting assessment results generate confusion for many policy and business decisions. In order to interpret and integrate assessment results, the paper provides a framework that clarifies the connections and coherence between the included assessment methodologies. Building on this framework, the paper further focuses on key aspects to adapt any of the methodologies to full sustainability assessments. Aspects dealt with in the review are for example the reported metrics, the scope, data requirements, discounting, product- or project-related and approaches with respect to scarcity and labor requirements. In addition to these key aspects, the review shows that important connections exist: (i) the three tools can cope with social inequality, (ii) processes such as valuation techniques for LCC and CBA are common, (iii) Environmental Impact Assessment (EIA) is used as input in both LCA and CBA and (iv) LCA can be used in parallel with LCC. Furthermore, the most integrated sustainability approach combines elements of LCA and LCC to achieve the Life Cycle Sustainability Assessment (LCSA). The key aspects and the connections referred to in the review are illustrated with a case study on the treatment of end-of-life automotive glass. - Highlights: • Proliferation of assessment tools creates ambiguity and confusion. • The developed assessment framework clarifies connections between assessment tools. • Broadening LCA, key aspects are metric and data requirements. • Broadening LCC, key aspects are scope, time frame and discounting. • Broadening CBA, focus point, timespan, references, labor and scarcity are key.

54 ENVIRONMENTAL SCIENCES↗

Proton Improvement Plan II (PIP-II) Clock and Timing

The PIP-II timing system is planned to be a two-part system consisting of a global timing system (referred to as ACLK) that provides high level, event-based timing for the whole Fermilab accelerator complex while the second part is a RF synchronized clock system unique to the PIP-II Linac itself (referred to as LCLK). The ACLK System will make use of an external 10 MHz GPS based signal source as a reference for its 650 MHz phase lock as it is the reference frequency for the TCLK output of the system (needed to support legacy hardware around complex). The LCLK System will use a PIP-II Linac RF reference (162.5 MHz) from the Linac LLRF system to allow beam synchronized event placement. Both the ACLK and LCLK systems will have a clock output with a data frame of 16 event bits + 32 data bits with frames broadcast at 650 MHz, phase locked to the 10MHz reference in the case of ACLK and the PIP-II LLRF sourced 162.5 MHz reference in the case of LCLK.

43 PARTICLE ACCELERATORS↗

Time average vibration fringe analysis using Hilbert transformation

Quantitative phase information from a single interferogram can be obtained using the Hilbert transform (HT). We have applied the HT method for quantitative evaluation of Bessel fringes obtained in time average TV holography. The method requires only one fringe pattern for the extraction of vibration amplitude and reduces the complexity in quantifying the data experienced in the time average reference bias modulation method, which uses multiple fringe frames. The technique is demonstrated for the measurement of out-of-plane vibration amplitude on a small scale specimen using a time average microscopic TV holography system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Indicator-based Approach to Sustainable Management of Natural Resources (Chapter 12)

Assessing the sustainability of natural resource management choices for agricultural and forest lands requires quantification of potential changes to a set of environmental and socioeconomic indicators selected to characterize reference scenarios relative to projected future scenarios. Correctly framing the questions with local stakeholders is a critical first step in the sustainability assessment, and the questions that can be addressed are often limited by data availability. Selecting and prioritizing indicators with stakeholders to address their needs and concerns improves the likelihood of investment in monitoring and evaluation of those indicators over time. Computational techniques for analyzing interactions between the selected indicators are inherently affected by the scales and formats of the assembled indicator datasets. Data analytics have the potential to improve understanding of the potential synergies and tradeoffs involved with meeting multiple environmental and socioeconomic goals simultaneously, but timely and appropriate indicator datasets are not always available—even in this new era of “big data.” Continued improvements in data science and data analytics are needed to broaden understanding and acceptance of problems and to provide valuable information for natural resource management. Advances in these areas will enable society to design future landscapes that meet multiple objectives, including the provisioning of agricultural and forest resources along with a variety of ecosystem services (e.g., clean water and healthy soils).

Parish, Esther↗