Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference cell model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

438 records · Page 25

Effect of Curing Temperature and Composition on the Performance Properties of Saltstone - 12473

When freshly mixed Saltstone is placed into a vault at the Savannah River Site, the heat of hydration produced during curing causes the temperature of the grout to increase. It is not uncommon for the temperature of the grout to increase by 30 to 50 deg. C above the starting temperature depending on the vault size and location, environmental conditions and pour schedule. For example, temperatures measured by thermocouples in one cell have exceeded 70 deg. C. The elevated temperatures, once reached, can extend for weeks or even months. Recent studies at Savannah River National Laboratory (SRNL) have shown that curing simulated Saltstone mixes at elevated temperatures can lead to reduced compressive strength and dynamic Young's modulus as well as increased total porosity when compared to the same grout mixes cured at 20 deg. C. Samples cured at 60 deg. C can have hydraulic conductivities approximately 600 times greater than samples cured at 20 deg. C. Previous studies have shown that the 60 deg. C cured mix had a dynamic Young's modulus that was half that of the mix cured at 20 deg. C. However, high temperature curing may not always have negative effects on the performance properties of the grout. These results indicate that higher curing temperatures can significantly alter the performance properties that are inputs for the Saltstone Performance Assessment. The Saltstone formulation (mix design) must produce a grout waste form that meets both placement and performance properties. A statistically designed set of mixes was developed to determine key process and compositional factors that affect the performance properties of Saltstone grout. A total of 27 mixes were batched and tested. There are eight baseline mixes that contain high and low values of aluminate concentration, varying w/p ratio, and varying fly ash content in the premix. Each of the eight mixes was cured at 22, 40 and 60 deg. C. The three additional reference mixes batched at the beginning, middle and end of testing showed good reproducibility throughout the study. The results of varying the operational and compositional factors on the performance properties of Saltstone grout are: - The Young's modulus is inversely affected by the curing temperature of the grout. - The aluminate content of the salt solution increases the Young's modulus of the Saltstone for samples cured at 20 and 40 deg. C. - All grouts cured at 60 deg. C have low Young's moduli and the composition of the grout mix did not have any positive effects on the performance properties after curing at this temperature. - The fly ash content in the premix had not discernible effect on the Young's modulus. - The water to premix ratio does not affect the Young's modulus. - Grouts made with the high aluminate salt solution have lower hydraulic conductivities than those made with the low aluminate simulant. - Temperature has an inverse effect on the hydraulic conductivity. - In general, increasing the water to premix ratio and the fly ash content will increase the hydraulic conductivity. - The porosity and cured density of the Saltstone grout are primarily a factor of the water to premix ratio of the grout formulation. The correlation between hydraulic conductivity and Young's modulus investigated in previous studies was evaluated further in this report. The current data as well as data from previous studies was fitted by a second degree polynomial function with a 77.1 % R-squared value. This model can be used to estimate the hydraulic conductivity of a sample based its Young's modulus for a limited range (E values up to 7 GPa). More data points should be included to further define the relationship between these performance properties are high Young's moduli and low hydraulic conductivities. The Young's modulus should still be measured on grouts formulated in future studies to be used as screening method for samples to be sent for hydraulic conductivity measurements. Saltstone grout has a complicated microstructure that is affected by the composition of the salt solution, the dry feed mixture composition, and the conditions under which it cures. The performance properties investigated are interrelated, which can make it difficult to determine individual relationships between various factors. Porosity is a large factor in determining both the Young's modulus and the hydraulic conductivity of the samples. Although the cured density is a straightforward measurement, it is not a significant performance property that needs further investigation. The porosity measurement provides similar and more meaningful data in relation to other performance properties. Based on the results of this study, the aluminate content of the salt solution does have an effect on the Young's modulus and the hydraulic conductivity and its effects should continue to be investigated. However, a new projection of aluminate contents should be used since projections change over time. The variability of fly ash in the premix did not prove to be a contributing factor that effects the performance properties of Saltstone and does not need to be included in future studies unless significant deviations from the baseline mix are proposed. The water to premix ratio has a significant effect on the performance properties of interest and the effects of varying this factor need further investigation. It is recommended that smaller ranges of w/p are investigated in order to provide data that is more relevant to the Saltstone being placed in the vaults. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Temperature Steam Electrolysis Process Performance and Cost Estimates

Technology readiness levels (TRLs) of electrolysis systems have dramatically increased in recent years as the interest in clean hydrogen production and decarbonization of transportation, industrial and other sectors increases across the globe. This is especially true of high temperature steam electrolysis (HTSE) / solid oxide electrolysis cell (SOEC) systems which show promise of much higher system efficiencies than other more developed electrolysis technologies. This possibility of higher efficiencies of HTSE / SOEC systems has been previously assumed to be theoretically possible but in recent years it has become less theoretical and more realistic as an increasing amount of suppliers complete lab and pilot tests showing very promising results. Research in the areas of manufacturing techniques, material selection, electrode and electrolyte compositions, and balance of plant size and integration continues at a fast pace as an increasing number of suppliers both internationally and domestically become involved. The advantages of HTSE become more pronounced when HTSE is coupled with nuclear power plants (NPPs). This is because thermal energy produced by the nuclear reactor can be used in a series of heat transfer loops and heat exchangers to vaporize HTSE feedwater, which drastically improves the economics of the process. Idaho National Laboratory (INL) has been very involved in the research and modeling of HTSE systems for a number of years, in collaboration with other national laboratories, academia, and industry stakeholders both on the hydrogen production as well as the hydrogen demand side. The modeling completed over the years on a large variety of projects has led to a wealth of knowledge at INL including in the area of the technoeconomic assessment (TEA) of HTSE systems. TEAs include process modeling of the HTSE systems to calculate system energy requirements and equipment sizing, followed by estimation of capital and operating costs to enable calculation of the levelized cost of hydrogen (LCOH). The TEA work performed has produced incremental improvements and tuning of the methods, assumptions, models, and results of the analyses as well as providing some opportunities for validating these results. The purpose of this document is to record the current baseline HTSE analyses led by INL to show the current status of assumptions and costs of these systems. Given the rapid development of this technology, the variety of suppliers entering the space, and the increasing attention government and industry are giving to such systems, this document may be updated on a periodic basis with updated analysis and assumptions. This document compiles various analyses results and approaches completed over a period of years into a single document to be used as a baseline going forward. It represents what the INL HTSE analysis group assumes to be the internal best estimate of the current operation, costs, and landscape of the HTSE industry state of the art capability for current SOEC technology in an Nth-of-a-Kind (NOAK) plant, which in this study is defined as existence of the manufacturing capacity to support previous deployment of N = 100 count of 25 MWe modular HTSE blocks (with modular equipment component cost reductions specified as following a 95% learning curve). That said, This is a public document and as such so no proprietary data was used or included in this report. There may be HTSE suppliers that have performance specifications, and cost estimates, and test data that differ from the analysis presented in this document. This document is meant to be a best conservative estimate of the technology and not an absolute reference.

08 HYDROGEN↗

High Temperature Steam Electrolysis Process Performance and Cost Estimates - DOE Hydrogen Program AMR Presentation

Technology readiness levels (TRLs) of electrolysis systems have dramatically increased in recent years as the interest in clean hydrogen production and decarbonization of transportation, industrial and other sectors increases across the globe. This is especially true of high temperature steam electrolysis (HTSE) / solid oxide electrolysis cell (SOEC) systems which show promise of much higher system efficiencies than other more developed electrolysis technologies. This possibility of higher efficiencies of HTSE / SOEC systems has been previously assumed to be theoretically possible but in recent years it has become less theoretical and more realistic as an increasing amount of suppliers complete lab and pilot tests showing very promising results. Research in the areas of manufacturing techniques, material selection, electrode and electrolyte compositions, and balance of plant size and integration continues at a fast pace as an increasing number of suppliers both internationally and domestically become involved. The advantages of HTSE become more pronounced when HTSE is coupled with nuclear power plants (NPPs). This is because thermal energy produced by the nuclear reactor can be used in a series of heat transfer loops and heat exchangers to vaporize HTSE feedwater, which drastically improves the economics of the process. Idaho National Laboratory (INL) has been very involved in the research and modeling of HTSE systems for a number of years, in collaboration with other national laboratories, academia, and industry stakeholders both on the hydrogen production as well as the hydrogen demand side. The modeling completed over the years on a large variety of projects has led to a wealth of knowledge at INL including in the area of the technoeconomic assessment (TEA) of HTSE systems. TEAs include process modeling of the HTSE systems to calculate system energy requirements and equipment sizing, followed by estimation of capital and operating costs to enable calculation of the levelized cost of hydrogen (LCOH). The TEA work performed has produced incremental improvements and tuning of the methods, assumptions, models, and results of the analyses as well as providing some opportunities for validating these results. The purpose of this document is to record the current baseline HTSE analyses led by INL to show the current status of assumptions and costs of these systems. Given the rapid development of this technology, the variety of suppliers entering the space, and the increasing attention government and industry are giving to such systems, this document may be updated on a periodic basis with updated analysis and assumptions. This document compiles various analyses results and approaches completed over a period of years into a single document to be used as a baseline going forward. It represents what the INL HTSE analysis group assumes to be the internal best estimate of the current operation, costs, and landscape of the HTSE industry state of the art capability for current SOEC technology in an Nth-of-a-Kind (NOAK) plant, which in this study is defined as existence of the manufacturing capacity to support previous deployment of N = 100 count of 25 MWe modular HTSE blocks (with modular equipment component cost reductions specified as following a 95% learning curve). That said, this is a public document and as such so no proprietary data was used or included in this report. There may be HTSE suppliers that have performance specifications, and cost estimates, and test data that differ from the analysis presented in this document. This document is meant to be a best conservative estimate of the technology and not an absolute reference.

08 HYDROGEN↗

A Dual Stage Sodium Thermo-Electro-Chemical Converter

The need for reliable and distributable energy sources is evident given the current forecasting of the world’s energy demand [1]. One prominent obstacle is the lack of an efficient direct heat-to-electricity conversion technology. The sodium thermo-electro-chemical converter (Na-TECC) is a highly efficient thermally regenerative electrochemical system (TRES) that can fill this void. The advantage of the Na-TECC over other direct conversion technologies is that it is a closed device (unlike fuel cells) requiring nothing more than a heat input (similar to thermoelectrics). It also has a high power density (> 1 W/cm2) and specific power up to 0.5 kW/kg , with the potential to achieve > 45% heat to electricity conversion efficiencies [2]. Furthermore, the converter rejects heat at a temperature hot enough to make it amenable for cogeneration, potentially under air-cooled operation. This electrochemical technology uses a special ion-selective solid-electrolyte called beta-alumina (Na2O•11Al2O3), that is highly conductive to sodium cations. A more conducting variation of this compound is beta”-alumina (Na2O•MgO•5Al2O3), where the magnesium acts as a stabilizer [3]. In the device, liquid sodium enters an evaporator where it is heated isobarically and vaporizes. The vapor is then oxidized at the interface between the anode and the solid-electrolyte. The Na-TECC generates electric power by allowing the high pressure oxidized sodium vapor ions to expand isothermally through the solid-electrolyte from the anode to the cathode. The liberated electrons are simultaneously conducted through an external load and recombine with the cations at the cathode. The low pressure sodium vapor is subsequently condensed and a wick pumps the liquid into the high pressure plenum to complete the cycle. Previous Na-TECCs have achieved efficiencies of 18% due to practical losses, whereas the potential efficiencies are above 45% [4]. Thermodynamic limitations and design constraints have limited previous devices from attaining these record efficiencies. Specifically, the maximum potential voltage in these previous devices was substantially reduced by the kinetic limitations of the charge transfer in the cathode (referred to as the overpotential) and by Joule heating losses due to the solid-electrolyte resistance, electrode resistance, and current collector resistance. Moreover, previous devices experienced a steady loss in performance throughout their lifetime. The drop in performance has been attributed to the electrolyte undergoing thermal and chemical breakdown due to crack propagation, loss of sodium oxide, and the formation of molten dendrites that create electrical shorts [5]. Finally, previous designs have also had a substantial problem with proper thermal management, with some showing thermal losses as great as 50% of the heat input. To improve the efficiency, a dual stage conversion process is being explored. Rather than using one isothermal expansion step, the dual cycle will employ two separate electrolytes to allow two separate expansion steps: one at the high temperature, and another at an intermediate temperature. This new cycle is thermodynamically favorable as it allows for regeneration from the isobaric cooling of the first expansion step, and reheat to complete the expansion in the second step. This allows the engine to reach a lower condenser temperature than its single stage counterpart, thus increasing the overall efficiency. The temperature drop across each electrolyte in the dual stage device (e.g., ~ 400 K) is smaller than the temperature drop across a comparable single stage device (e.g., ~ 800 K). This is amenable for better thermal management and allows for less heat loss. This will also mitigate the thermal shock across the very thin (< 1 mm) solid electrolytes, reduce crack propagation and limit the percolation of the molten dendrites, and ultimately increase the lifetime of the device. As an additional benefit the dual stage can be designed using planer geometries, rather than tubular geometries used in previous single stage models, which can be manufactured less expensively. This modified geometry can be tailored to improve the thermal management by reducing the radiation losses, which has been the biggest source of thermal losses [2]. A dual stage concept for the Na-TECC has never been demonstrated in literature. In this presentation, the operation of a single stage device will be revisited and, by adopting concepts used for similar converters, the thermodynamic operation of the dual stage will be developed [6]. Using the dual stage approach, the efficiency and power equations have been redefined to include regeneration and reheat. Questions such as what current densities optimize the power output or which intermediate temperature maximizes the efficiency will also be answered. Initial calculations of the dual stage show that the thermal management is the most sensitive parameter. Although the ideal voltage produced by the dual stage can be higher, there are potential drawbacks. For example, by using a lower condenser temperature the dual stage device will have a higher open circuit voltage, but it will also have a larger overpotential due to the limited cathodic kinetics that occur at a lower temperature. In short, there are several trade-offs in this device that need to be balanced. It will be demonstrated that the dual stage device must have lower thermal losses than a single stage device if it is to have a higher efficiency.

14 SOLAR ENERGY↗

PAPER STUDY EVALUATIONS OF THE INTRODUCTION OF SMALL COLUMN ION EXCHANGE WASTE STREAMS TO THE DEFENSE WASTE PROCESSING FACILITY

The objective of this paper study is to provide guidance on the impact of Monosodium Titanate (MST) and Crystalline Silicotitanate (CST) streams from the Small Column Ion Exchange (SCIX) process on the Defense Waste Processing Facility (DWPF) flowsheet and glass waste form. A series of waste processing scenarios was evaluated, including projected compositions of Sludge Batches 8 through 17 (SB8 through SB17), MST additions, CST additions to Tank 40 or to a sludge batch preparation tank (Tank 42 or Tank 51, referred to generically as Tank 51 in this report), streams from the Salt Waste Processing Facility (SWPF), and two canister production rates. A wide array of potential glass frit compositions was used to support this assessment. The sludge and frit combinations were evaluated using the predictive models in the current DWPF Product Composition Control System (PCCS). The results were evaluated based on the number of frit compositions available for a particular sludge composition scenario. A large number of candidate frit compositions (e.g., several dozen to several hundred) is typically a good indicator of a sludge composition for which there is flexibility in forming an acceptable waste glass and meeting canister production rate commitments. The MST and CST streams will significantly increase the concentrations of certain components in glass, such as Nb{sub 2}O{sub 5}, TiO{sub 2}, and ZrO{sub 2}, to levels much higher than have been previously processed at DWPF. Therefore, several important assumptions, described in detail in the report, had to be made in performing the evaluations. The results of the paper studies, which must be applied carefully given the assumptions made concerning the impact of higher Ti, Zr, and Nb concentrations on model validity, provided several observations: (1) There was difficulty in identifying a reasonable number of candidate frits (and in some cases an inability to identify any candidate frits) when a waste loading of 40% is targeted for Sludge Batches 8, 16, and 17, regardless of the addition of SCIX or SWPF streams. This indicates that the blending strategy for these sludge batches should be reevaluated by Savannah River Remediation (SRR). (2) In general, candidate frits were available to accommodate CST additions to either Tank 40 or Tank 51. A larger number of candidate frits were typically available for the sludge batches when CST is added to Tank 51 rather than Tank 40, meaning that more compositional flexibility would be available for frit selection and DWPF operation. Note however that for SB8 and SB17, no candidate frits were available to accommodate CST going to Tank 40 with and without SWPF streams. The addition of SWPF streams generally improves the number of candidate frits available for processing of a given sludge batch. (3) The change in production rate from 40 Sludge Receipt and Adjustment Tank (SRAT) batches per year (i.e., the current production rate) to 75 SRAT batches per year, without SWPF streams included, had varied results in terms of the number of candidate frits available for processing of a given sludge batch. Therefore, this variable is not of much concern in terms of incorporating the SCIX streams. Note that the evaluation at 75 SRAT batches per year (approximately equivalent to 325 canisters per year) is more conservative in terms of the impact of SCIX streams as compared to a production rate of 400 canisters per year. Overall, the outcome of this paper study shows no major issues with the ability to identify an acceptable glass processing window when CST from the SCIX process is transferred to either Tank 40 or Tank 51. The assumptions used and the model limitations identified in this report must be addressed through further experimental studies, which are currently being performed. As changes occur to the planned additions of MST and CST, or to the sludge batch preparation strategy, additional evaluations will be performed to determine the potential impacts. As stated above, the issues with Sludge Batches 8, 16, and 17 should be further evaluated by SRR. A review of Chemical Process Cell (CPC) processing identified no changes to the recommendations from the previous review of the SCIX process impacts. Recommendations for testing were made during the previous review to evaluate the impact of CST on the rheological properties of DWPF process streams and evaluate the impact of CST on catalytic hydrogen generation during CPC processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Size-resolved ice nucleating particle (INP) concentrations from the MOSAiC campaign

Sample collection: Ground-based immersion mode ice nucleation measurements were conducted on samples collected at the U.S. DOE ARM AMF2 onboard the R/V Polarstern P-deck during MOSAiC from 23 Oct 2019 to 01 Oct 2020. Samples were collected using a Davis Rotating-drum Unit for Monitoring (DRUM; DRUMAir, LLC) cascading impactor in 4 stages (i.e., size bins). Instrument information on the model used, the DA400, can be found at the DRUMAir website (http://www.drumair.com/). Stages A, B, C, and D had particle size cuts at 2.96, 1.21, 0.34, and 0.15 &micro;m in particle diameter, respectively. Strips of sample substrate (PFA, perfluoroalkoxy; McMaster) were adhered to each disc in each stage and coated with petrolatum to enable particles to stick on impact. The discs move slowly over time, such that aerosol loading is streaked onto the PFA. Every 24 hours, a blank is created on the PFA to separate daily samples. During MOSAiC, the pump typically pulled 20 &ndash; 35 lpm (average of 32 lpm) at the inlet with all the discs in place in each stage. Daily samples were collected for each of the four stages, equaling 28,800 &ndash; 50,400 total L of air (average of 46,080 L total L of air) per sample. Discs rotated for approximately 24 days before the sampling per strip was complete and changed to a new disc. Discs were stored frozen after collection. Sample preparation for analysis: Following collection and transport from MOSAiC to the Kreidenweis/DeMott laboratory, care of PI Creamean, in Fort Collins, CO, strips were removed from the discs and cut up to separate daily samples. Each daily portion of the strip was stored in separate sterile 15-mL centrifuge tubes and stored in a standard commercial freezer until analysis (approximately 4 &ndash; 12 months after collection). Sample analysis: Drop freezing assays (DFAs) were conducted on one daily sample set every 3 &ndash; 4 days of the study for all four stages using the Colorado State University (CSU) cold plate (CP). Sample set days were chosen to cover the entire year of MOSAiC and avoiding days where the AOS purge system was activated. Immediately after removal from the freezer, 2 mL of 0.1-&micro;m filtered deionized water was added with a single-use sterile syringe directly to the tubes, then mixed using a vortex mixer for at least 30 minutes at 500 rpm to resuspend particles from the PFA into the deionized water. Following sample preparation, another single-use syringe was used to create 100 aliquots on a 3-inch diameter copper plate, then covered with a transparent plastic dome. The drops were approximately the same volume (2.5 &micro;L each), though careful inspection. The plate was cooled at approximately 3 &ndash; 10 K min-1 from room temperature until all drops froze on the plate. Temperature was measured by an Omega thermocouple probes and meter. Drop freezing was visually detected but recorded through monitoring software to provide the time frozen, channel of the meter used, temperature, and cooling rate for each drop. Not all 100 drops were always detected; the total number of rows in each data file equals the number of drops recorded, which typically was > 80 %. Each sample was tested three times (i.e., a new set of 100 drops was created for each test). Data provided are files containing these parameters. From the freezing temperatures recorded, the fraction frozen was and INP concentrations were calculated per L of air using the equation from Vali (1971): [INPs] = &minus;(ln(f)/Valiquot)*(Vsuspension/Vair) where f is the proportion of droplets not frozen, Valiquot is the volume of each aliquot (i.e., 2.5e-6 L), Vsuspension is the volume of the suspension (i.e., 0.002 L), and Vair is the volume of air per sample (i.e., 36000 L). Data usage guidance: There are three files included with this dataset: (1) dumcp_inp_concentrations.csv which includes cumulative INP concentrations binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C for all samples and size ranges (i.e., DRUM stages) processed via DFA using the CSU CP; (2) dumcp_inp_standard_deviation.csv which includes the standard deviations for all samples and temperatures in dumcp_inp_concentrations.csv; and (3) dumcp_blank_concentrations_standard_deviation.csv which includes the INP concentrations and standard deviations for the deionized water and PFA blanks binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C. The first column in each file represents the freezing temperature in &deg;C binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C (first cell in this column = header = &ldquo;temp&rdquo;). The second column in each file represents the standard deviation of each temperature bin in &deg;C (first cell in this column = header = &ldquo;temperr&rdquo;). For file (1) dumcp_inp_concentrations.csv, the remaining columns indicate the INP concentrations per L of air for each temperature bin. For each sample column, the header in the first row indicates the stage (i.e., size bin as &ldquo;A_&rdquo;, &ldquo;B_&rdquo;, &ldquo;C_&rdquo;, or &ldquo;D_&rdquo;) and date (&ldquo;_yyyymmdd) of collection. For file (2) dumcp_inp_standard_deviation.csv, the remaining columns indicate the INP concentration standard deviation per L of air for each temperature bin. For each sample column, the header in the first row indicates the stage (i.e., size bin as &ldquo;A_&rdquo;, &ldquo;B_&rdquo;, &ldquo;C_&rdquo;, or &ldquo;D_&rdquo;) and date (&ldquo;_yyyymmdd) of collection. For file (3) dumcp_blank_concentrations_standard_deviation.csv, the remaining columns indicate the INP concentrations and standard deviations for the deionized water blank (&ldquo;di_0.1&rdquo; and &ldquo;di_0.1sd&rdquo; for the concentrations and standard deviations, respectively) and PFA blank (&ldquo;pfa&rdquo; and &ldquo;pfasd&rdquo; for the concentrations and standard deviations, respectively). Please see Creamean et al. (2019a; 2018a; 2018b; 2019b) for additional details on DRUM sample collection and offline processing. For questions or help with data interpretation, contact Dr. Jessie Creamean (jessie.creamean@colostate.edu). References: Creamean, J. M., Mignani, C., Bukowiecki, N., and Conen, F.: Using spectra characteristics to identify ice nucleating particle populations during winter storms in the Alps, Atmos. Chem. Phys., 19, 8123&ndash;8140, 2019a. Creamean, J. M., Kirpes, R. M., Pratt, K. A., Spada, N. S., Maahn, M., de Boer, G., Schnell, R. C., and China, S.: Marine and terrestrial influences on ice nucleating particles during continuous springtime measurements in an Arctic oilfield location, Atmospheric Chemistry and Physics, 18, 18023-18042, 10.5194/acp-18-18023-2018, 2018a. Creamean, J. M., Primm, K. M., Tolbert, M. A., Hall, E. G., Wendell, J., Jordan, A., Sheridan, P. J., Smith, J., and Schnell, R. C.: HOVERCAT: A novel aerial system for evaluation of aerosol-cloud interactions, Atmospheric Measurement Techniques, 11, 3969-3985, 10.5194/amt-11-3969-2018, 2018b. Creamean, J. M., Cross, J. N., Pickart, R., McRaven, L., Lin, P., Pacini, A., Hanlon, R., Schmale, D. G., Ceniceros, J., Aydell, T., Colombi, N., Bolger, E., and DeMott, P. J.: Ice nucleating particles carried from below a phytoplankton bloom to the Arctic atmosphere, Geophys. Res. Lett., 46, 8572-8581, https://doi.org/10.1029/2019GL083039, 2019b. Vali, G.: Quantitative Evaluation of Experimental Results an the Heterogeneous Freezing Nucleation of Supercooled Liquids, Journal of the Atmospheric Sciences, 28, 402-409, 10.1175/1520-0469(1971)028<0402:qeoera>2.0.co;2, 1971.

4-stage DRUM aerosol collector (DA400),Ice nuclei,↗