Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “receiver functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

TU-G-BRA-01: Assessing Radiation-Induced Reductions in Regional Lung Perfusion Following Stereotactic Radiotherapy for Lung Cancer

Purpose: The dose-dependent nature of radiation therapy (RT)-induced lung injury following hypo-fractionated stereotactic RT is unclear. We herein report preliminary results of a prospective study assessing the magnitude of RT-induced reductions in regional lung perfusion following hypo-fractionated stereotactic RT. Methods: Four patients undergoing hypo-fractionated stereotactic lung RT (SBRT: 12 Gy x 4 fractions or 10 Gy x 5 fractions) had a pre-treatment SPECT (single-photon emission computed tomography) perfusion scan providing a 3D map of regional lung perfusion. Scans were repeated 3–6 months post-treatment. Pre- and post SPECT scans were registered to the planning CT scan (and hence the 3D dose data). Changes in regional perfusion (counts per cc on the pre-post scans) were computed in regions of the lung exposed to different doses of radiation (in 5 Gy intervals), thus defining a dose-response function. SPECT scans were internally normalized to the regions receiving <5 Gy. Results: At 3 months post-RT, the changes in perfusion are highly variable. At 6 months, there is a consistent dose-dependent reduction in regional perfusion. The average percent decline in regional perfusion was 10% at 15–20 Gy, 20% at 20–25 Gy, and 30% at 25–30 Gy representing a relatively linear dose response with an approximate 2% reduction per Gray for doses in excess of 10 Gy. There was a subtle increase in perfusion in the lung receiving <10 Gy. Conclusion: Hypo-fractionated stereotactic RT appears to cause a dose-dependent reduction in regional lung perfusion. There appears to be a threshold effect with no apparent perfusion loss at doses <10 Gy, though this might be in part due to the normalization technique used. Additional data is needed from a larger number of patients to better assess this issue. This sort of data can be used to assist optimizing RT treatment plans that minimize the risk of lung injury. Partly supported by the NIH (CA69579) and the Lance Armstrong Foundation.

60 APPLIED LIFE SCIENCES↗

Navigation Doppler Lidar Signal Processing Architecture and Algorithms

A coherent Doppler lidar has been developed to address the need for a high-performance, compact, and cost-effective velocity and altitude sensor onboard landing vehicles. One of the core subsystems within NDL is its signal processing architecture. The primary function of this subsystem is to digitize the analog output of the homodyned signal received from the photo-diode associated with each telescope, process this signal in the frequency domain, and then turn this information into velocity and range measurements. A secondary function of this subsystem is to setup and control the internal components within NDL and to enable the instrument to interface with external systems by receiving commands, sending telemetry, and synchronizing its measurements with external clocks and pulses. This paper will give an overview of the signal processing architecture within NDL. This will include a discussion on its fundamental processing components and the core signal processing algorithms. Command, telemetry and internal component controls will also be discussed as will how the signal processing architecture has also evolved over the years of development. We will discuss provisions for robust operation including Triple-Mode Redundancy (TMR) within NDL’s Field Programmable Gate Array (FPGA) and storage elements, a fault-tolerant boot process, and Error Detection and Correction (EDAC) on the Static Random-Access Memories (SRAMs). Finally, we conclude this paper with how this architecture could continue to evolve.

Doppler Lidar↗

Going Up. A GPS Receiver Adapts to Space

Current plans for the space station call for the GPS receiver to be installed on the U.S. lab module of the station in early 2001 (ISS Assembly Flight SA), followed by the attachment of the antenna array in late 2001 (Flight 8A). At that point the U.S. ISS guidance and control system will be operational. The flight of SIGI on the space station represents a "coming of age" for GPS technology on spacecraft. For at least a decade, the promise of using GPS receivers to automate spacecraft operations, simplify satellite design, and reduce mission costs has enticed satellite designers. Integration of this technology onto spacecraft has been slower than some originally anticipated. However, given the complexity of the GPS sensor, and the importance of the functions it performs, its incorporation into mainstream satellite design has probably occurred at a very reasonable pace. Going from providing experimental payloads on small, unmanned satellites to performing critical operational functions on manned vehicles has been a major evolution. If all goes as planned in the next few months, GPS receivers will soon provide those critical functions on one of the most complex spacecraft in history, the International Space Station.

Lightsey, E. Glenn↗

Multi-Institutional Experience of Ductal Carcinoma In Situ in Black vs White Patients Treated With Breast-Conserving Surgery and Whole Breast Radiation Therapy

Purpose: Given the paucity of data on racial disparities in ductal carcinoma in situ (DCIS), the data from a multi-institutional cohort of DCIS patients treated with breast-conserving surgery and whole breast radiation therapy (RT) were analyzed to determine whether racial disparities or differences exist. Methods and Materials: A total of 533 white and 76 black DCIS patients from 3 university-based cancer centers were uniformly treated with breast-conserving surgery and RT. All patient data were collected and analyzed as a function of race. Results: The median follow-up was 5.2 years. No significant racial differences were seen in tumor size, age at diagnosis, estrogen receptor status, necrosis, or grade (all P>.05). Of the treatment parameters, the RT dose delivered, boost, positive margin rates, frequency of hormone receptor status assessment, and receipt of hormonal therapy for the 2 cohorts did not significantly differ (all P>.05). The local relapse-free survival was similar at 5 years (96.1% and 98.1%, P=.399) and 10 years (92.8% vs 95.8%, P=.360), with no significant overall survival difference at 10 years (94.0% vs 88.9%, P=.290) between the white and black patients, respectively. On multivariate analysis, race was not an independent predictor of local relapse-free survival or overall survival when accounting for age, grade, and margin status. Conclusion: In our large cohort of DCIS patients uniformly treated at 3 institutions with breast conservation without any apparent differences in treatment delivery parameters, we demonstrated that the clinical and pathologic features and local survival outcomes did not differ as a function of race. Our results suggest that when black patients with DCIS are appropriately selected for breast conservation and receive adjuvant RT without racial disparities in the treatment parameters, differences in the outcomes as a function of race do not exist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

System Engineering Analysis For Improved Scout Business Information Systems

The project uses system engineering principles to address the need of Boy Scout leaders for an integrated system to facilitate advancement and awards records, leader training and planning for meetings and activities. Existing products to address needs of Scout leaders and relevant stakeholders function to support record keeping and some communication functions but opportunity exists for a better system to fully integrate these functions with training delivery and recording, activity planning along with feedback and information gathering from stakeholders. Key stakeholders for the sytem include Scouts and their families, leaders, training providers, sellers of supplies and awards, content generators and facilities that serve Scout activities. Key performance parameters for the system are protection of personal information, availability of current information, information accuracy and information content that has depth. Implementation concepts considered for the system include (1) owned and operated by Boy Scouts of America, (2) Contracted out to a vendor (3) distributed system that functions with BSA managed interfaces. The selected concept is to contract out to a vendor to maximize the likelihood of successful integration and take advantage of the best technology. Development of requirements considers three key use cases (1) System facilitates planning a hike with training needed satisfied in advance and advancement recording real time (2) Scheduling and documenting in-person training, (3) Family interested in Scouting receives information and can request follow-up. Non-functional requirements are analyzed with the Quality Function Deployment tool. Requirement addressing frequency of backup, compatibility with legacy and new technology, language support, software update are developed to address system reliability and intuitive interface. System functions analyzed include update of activity database, maintenance of advancement status, archive of documents, and monitoring of content that is accessible. The study examines risks associated with information security, technological change and continued popularity of Scouting. Mitigation is based on system functions that are defined. The approach to developing an improved system for facilitating Boy Scout leader functions was iterative with insights into capabilities coming in the course of working through the used cases and sequence diagrams.

97 MATHEMATICS AND COMPUTING↗

Remote sensing of ice phenomena from orbit by signal correlation of multiple receiver responses

The method of signal correlation of microwave responses as applied to the measurement of Earth-surface ice temperatures from orbit is explained and summarized. Ice temperatures are estimated by a correlation function that is derived from the processes of a forward stepwise correlator. Subsets of the post-detected outputs of microwave receiving channels are combined in a multivariate cross-correlation function which operates as a spatial filter and serves to improve the spatial resolution of the thermal gradients in ice structures. The correlator is designed to selectively identify the correlative components among the microwave responses and to strongly suppress or cancel the non-correlative components appearing in the post-detected outputs.

Stacey, J. M.↗

Network acceleration techniques

Splintered offloading techniques with receive batch processing are described for network acceleration. Such techniques offload specific functionality to a NIC while maintaining the bulk of the protocol processing in the host operating system ("OS"). The resulting protocol implementation allows the application to bypass the protocol processing of the received data. Such can be accomplished this by moving data from the NIC directly to the application through direct memory access ("DMA") and batch processing the receive headers in the host OS when the host OS is interrupted to perform other work. Batch processing receive headers allows the data path to be separated from the control path. Unlike operating system bypass, however, the operating system still fully manages the network resource and has relevant feedback about traffic and flows. Embodiments of the present disclosure can therefore address the challenges of networks with extreme bandwidth delay products (BWDP).

Crowley, Patricia↗

MS Non-Pharmacological Countermeasure to Decrease Landing Sickness and Improve Functional Performance While Disorientad

Upon return from spaceflight, a majority of crewmembers experience motion sickness (MS) symptoms. The interactions between crewmembers' adaptation to a gravitational transition, the performance decrements resulting from MS and/or use of promethazine (PMZ), and the constraints imposed by mission task demands could significantly challenge and limit an astronaut's ability to perform functional tasks during gravitational transitions. No operational countermeasure currently exists to mitigate the risks associated with these sensorimotor disturbances. Stochastic resonance (SR) can be thought of simply as "noise benefit" or an increase in information transfer by a system when in the presence of a non-zero level of noise. We have shown that low levels of stochastic vestibular stimulation (SVS) improve balance and locomotor performance due to SR (Goel et al. 2015, Mulavara et al. 2011, 2015). Additionally, a study in a 6-hydroxydopamine (6-OHDA) hemi-lesioned rat model of Parkinson's disease demonstrated improvements in locomotor activity after low-level SVS delivery possibly due to an increase in nigral gamma-aminobutyric acid (GABA) release in a dopamine independent way (Samoudi et al. 2012). SVS specifically increased GABA release on the lesioned, but not the intact side. These results suggest that SVS can cause targeted alterations of GABA release to affect performance of functional tasks. Activation of the GABA pathway is important in modulating MS and promoting adaptability (Cohen 2008). Magnusson et al. (2000) supported this finding by showing that the administration of a GABAB agonist caused a reversal of the symptoms that is normally seen after unilateral labyrinthectomy. Thus, GABA could play a significant role in reducing MS and promoting adaptability. We have taken advantage of the SR mechanism as a modulator of neurotransmitters to develop a unique SVS countermeasure system to mitigate MS symptoms and improve functional performance after landing. Healthy subjects (n=20) participated in two test sessions, one in which they received +/-400 microA of SVS and one where they received no stimulation (0 microA); the study design was counterbalanced. Subjects began by performing a series of four functional tasks 3-5 times as baseline measurements of task performance. Then, to induce MS, subjects walked an obstacle course with up-down reversing prisms. If they completed the course before achieving our pre-determined level of MS, they were asked to read a poster while making large up-down head movements to a metronome while still wearing the reversing prism goggles. Subjects were stopped every two minutes and asked to report their MS symptoms. Using the Pensacola Scale for motion sickness, test operators evaluated the level of MS of each subject. Once a subject reached an 8 on this scale, which is equivalent to mild malaise, or 30 minutes had passed since the start of the MS induction, this protocol was stopped. Finally, immediately after MS induction, subjects were asked to complete the four functional tasks again. Although, 100% of our subjects experienced at least one MS symptom, only 55% of our subjects experienced stomach awareness to any degree. Without SVS, only 40% of subjects lasted the full 30-minute MS induction protocol, while 65% of subjects lasted the full 30 minutes with SVS, which is nearly a significant increase (p=0.056). In addition, subjects showed significant improvement from baseline when performing a tandem walk and a prone-to-stand test immediately after the MS induction protocol was stopped but the stimulation level was continued. The results are promising and future work includes comparing MS progression between PMZ and SVS directly in subjects that are provoked to a minimum of nausea. Low levels of SVS stimulation may serve as a non-pharmacological countermeasure to replace or reduce the PMZ dosage requirements and concurrently improve functional performance during transitions to new gravitational environments after spaceflight.

Rosenberg, M. J. F.↗

Covalent Crosslinking of Carbon Nanotube Materials for Improved Tensile Strength

Carbon nanotubes have attracted much interest in recent years due to their exceptional mechanical properties. Currently, the tensile properties of bulk carbon nanotube-based materials (yarns, sheets, etc.) fall far short of those of the individual nanotube elements. The premature failure in these materials under tensile load has been attributed to inter-tube sliding, which requires far less force than that needed to fracture individual nanotubes.1,2 In order for nanotube materials to achieve their full potential, methods are needed to restrict this tube-tube shear and increase inter-tube forces.Our group is examining covalent crosslinking between the nanotubes as a means to increase the tensile properties of carbon nanotube materials. We are working with multi-walled carbon nanotube (MWCNT) sheet and yarn materials obtained from commercial sources. Several routes to functionalize the nanotubes have been examined including nitrene, aryl diazonium, and epoxide chemistries. The functional nanotubes were crosslinked through small molecule or polymeric bridges. Additionally, electron beam irradiation induced crosslinking of the non-functional and functional nanotube materials was conducted. For example, a nanotube sheet material containing approximately 3.5 mol amine functional groups exhibited a tensile strength of 75 MPa and a tensile modulus of 1.16 GPa, compared to 49 MPa and 0.57 GPa, respectively, for the as-received material. Electron beam irradiation (2.2x 1017 ecm2) of the same amine-functional sheet material further increased the tensile strength to 120 MPa and the modulus to 2.61 GPa. This represents approximately a 150 increase in tensile strength and a 360 increase in tensile modulus over the as-received material with only a 25 increase in material mass. Once we have optimized the nanotube crosslinking methods, the performance of these materials in polymer matrix composites will be evaluated.

polymer matrix composites↗

Functional states of the operator

A study was made of the changes that occur in the functional state of the operator as he does his job. The functional state of the operator is understood to mean the available characteristics of his functions and qualities which, directly or indirectly, determine how he receives, processes, and reads out information. These characteristics change, depending on many conditions found on the job, and can be higher or lower, than those values which exist in the so-called operator rest state, when the person is doing nothing, but is ready to act. A number of environmental factors, directly or indirectly related to the job, act on the operator controlling a system. Analysis of the causes of changes in the functional state suggests they can be broken down into two main groups: those associated with the physical characteristics of the influencing factors, and those attributable to the informational structure of the signals. There are as well many internal causes, primarily changes in the basic properties of those functions on which operator performance depends for the most part, that affect the functional state.

Medvedev, V. I.↗

Calibration Results for J-ERS-1 SAR Data Produced by the Alaska SAR Facility

The Alaska SAR Facility has been receiving and processing SAR data from the J-ERS-1 satellite since Spring 1992. Corner reflectors have been set up for J-ERS-1 SAR calibration at a site near Delta Junction, in central Alaska. Image quality and calibration analysis results from the Delta Junction site and others will be presented in this paper. The impact of the 3-bit Analog-to-Digital Converter and the automatic stepping of the gain as a function of range in the J-ERS-1 radar receiver on calibration performance has been assessed. Preliminary observations on J-ERS-1 SAR data are that the average Signal-to-Noise ratio is generally fairly low, in the range 5-6dB. Azimuth ambiguity levels are higher than preflight analysis indicated. Over land, the dynamic range in the backscatter at L-band for approximately 36 degree incidence angle is often fairly high.

Freeman, A.↗

Calibration Results for J-ERS-1 SAR Data Produced by the Alaska SAR Facility

The Alaska SAR Facility has been receiving and processing SAR data from the J-ERS-1 satellite since Spring 1992. Corner reflectors have been set up for J-ERS-1 SAR calibration at a site near Delta Junction, in central Alaska. Image quality and calibration analysis results from the Delta Junction site and others will be presented in this paper. The impact of the 3-bit Analog-to-Digital Converter and the automatic stepping of the gain as a function of range in the J-ERS-1 radar receiver on calibration performance has been assessed. Preliminary observations on J-ERS-1 SAR data are that the average Signal-to-Noise ratio is generally fairly low, in the range 5-6 dB. Azimuth ambiguity levels are higher than preflight analysis indicated. Over land, the dynamic range in the backscatter at L-band for approximately 36 degree incidence angle is often fairly high...

Freeman, A.↗

Independent Orbiter Assessment: Assessment of the FMEA/CIL Instructions and Ground Rules

The McDonnell Douglas Astronautics Company was selected to conduct an independent assessment of the Orbiter Failure Mode and Effects Analysis/Critical Items List (FMEA/CIL). Part of this effort involved an examination of the FMEA/CIL preparation instructions and ground rules. Assessment objectives were to identify omissions and ambiguities in the ground rules that may impede the identification of shuttle orbiter safety and mission critical items, and to ensure that ground rules allow these items to receive proper management visibility for risk assessment. Assessment objectives were followed during the performance of the assessment without being influenced by external considerations such as effects on budget, schedule, and documentation growth. Assessment personnel were employed who had a strong reliability background but no previous space shuttle FMEA/CIL experience to ensure an independent assessment would be achieved. The following observations were made: (1) not all essential items are in the CIL for management visibility; (2) ground rules omit FMEA/CIL coverage of items that perform critical functions; (3) essential items excluded from the CIL do not receive design justification; and (4) FMEAs/CILs are not updated in a timely manner. In addition to the above issues, a number of other issues were identified that correct FMEA/CIL preparation instruction omissions and clarify ambiguities. The assessment was successful in that many of the issues have significant safety implications.

Traves, S. T.↗

Acute Cardiac Impairment Associated With Concurrent Chemoradiotherapy for Esophageal Cancer: Magnetic Resonance Evaluation

Purpose: To evaluate acute cardiac effects of concurrent chemoradiotherapy (CCRT) for esophageal cancer. Methods and Materials: This prospective study was approved by the institutional review board, and written informed consent was obtained from all participants. The left ventricular function (LVF) of 31 patients with esophageal cancer who received cisplatin and 5-fluorouracil-based CCRT was evaluated using cardiac cine magnetic resonance imaging. The patients were classified into two groups according to mean LV dose. The parameters related to LVF were compared between before and during (40 Gy) or between before and after CCRT using a Wilcoxon matched-pairs single rank test, and parameter ratios (during/before CCRT, after/before CCRT) were also compared between the groups with a t test. Data were expressed as mean {+-} SE. Results: In the low LV-dose group (n = 10; mean LV dose <0.6 Gy), LV ejection fraction decreased significantly (before vs. during vs. after CCRT; 62.7% {+-} 2.98% vs. 59.8% {+-} 2.56% vs. 60.6% {+-} 3.89%; p < 0.05). In the high LV-dose group (n = 21; mean LV dose of 3.6-41.2 Gy), LV end-diastolic volume index (before vs. after CCRT; 69.1 {+-} 2.93 vs. 57.0 {+-} 3.23 mL/m{sup 2}), LV stroke volume index (38.6 {+-} 1.56 vs. 29.9 {+-} 1.60 mL/m{sup 2}), and LV ejection fraction (56.9% {+-} 1.79% vs. 52.8% {+-} 1.15%) decreased significantly (p < 0.05) after CCRT. Heart rate increased significantly (before vs. during vs. after CCRT; 66.8 {+-} 3.05 vs. 72.4 {+-} 4.04 vs. 85.4 {+-} 3.75 beats per minute, p < 0.01). Left ventricle wall motion decreased significantly (p < 0.05) in segments 8 (before vs. during vs. after CCRT; 6.64 {+-} 0.54 vs. 4.78 {+-} 0.43 vs. 4.79 {+-} 0.50 mm), 9 (6.88 {+-} 0.45 vs. 5.04 {+-} 0.38 vs. 5.27 {+-} 0.47 mm), and 10 (9.22 {+-} 0.48 vs. 8.08 {+-} 0.34 vs. 8.19 {+-} 0.56 mm). The parameter ratios of LV end-diastolic volume index, stroke volume index, wall motion in segment 9, and heart rate showed significant difference (p < 0.05) after CCRT between the groups. Conclusions: Concurrent chemoradiotherapy for esophageal cancer impairs LVF from an early treatment stage. This impairment is prominent in patients with high LV dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Long-Term Outcomes and Toxicity After Stereotactic Phosphorus-32–Based Intracavitary Brachytherapy in Patients With Cystic Craniopharyngioma

Interstitial brachytherapy based on phosphorus-32 (P-32) has an established role as a minimally invasive treatment modality for patients with cystic craniopharyngioma. However, reporting on long-term outcomes with toxicity profiles for large cohorts is lacking in the literature. The purpose of this study is therefore to evaluate the long-term visual, endocrinal, and neurocognitive functions in what is the largest patient series having received this treatment to date.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The defect chemistry of nitrogen in oxides: A review of experimental and theoretical studies

Incorporation of nitrogen into oxides has in recent years received increased attention as a variable for tuning their functional properties. A vast number of reports have been devoted to improving the photocatalytic properties of TiO{sub 2}, p-type charge carrier concentration in ZnO and the ionic transport properties of ZrO{sub 2} by nitrogen doping. In comparison, the fundamentals of the nitrogen related defect chemistry for a wider range of oxides have been less focused upon. In the present contribution, we review experimental and computational investigations of the nitrogen related defect chemistry of insulating and semiconducting oxides. The interaction between nitrogen and protons is important and emphasized. Specifically, the stability of nitrogen defects such as N{sub O}{sup /}, NH{sub O}{sup Multiplication-Sign} and (NH{sub 2}){sub O}{sup Bullet} is evaluated under various conditions and their atomistic and electronic structure is presented. A final discussion is devoted to the role of nitrogen with respect to transport properties and photocatalytic activity of oxides. - Graphical abstract: Experimental and theoretical investigations of the nitrogen related defect chemistry of a range of wide band gap oxides is reviewed. The interaction between nitrogen dopants and protons is emphasized and described through the atomistic and electronic structure as well as defect chemical processes involving NH and NH{sub 2} defects. Consequently, the physical properties of oxides containing such species are discussed with respect to e.g., diffusion and photocatalytic properties. Highlights: Black-Right-Pointing-Pointer Experimental and theoretical investigations of the nitrogen and hydrogen related defect chemistry of wide band gap oxides is reviewed. Black-Right-Pointing-Pointer The interaction between nitrogen dopants and protons is important and emphasized. Black-Right-Pointing-Pointer Diffusion and photocatalytic properties of N-doped oxides are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Studies on phase formation, microstructure development and elastic properties of reduced NiO-8YSZ anode supported bi-layer half-cell structures of solid oxide fuel cells

Highlights: Black-Right-Pointing-Pointer Detailed study on the development of microstructure and phase in NiO-8YSZ anodes. Black-Right-Pointing-Pointer Detailed study on elastic properties at high temperatures in air/reducing atmosphere. Black-Right-Pointing-Pointer Effects of initial porosity, composition and other issues are evaluated in detail. -- Abstract: Half-cell structures of solid oxide fuel cells (SOFCs) with a thin and dense electrolyte layer of 8YSZ supported by a thick and porous NiO-8YSZ anode precursor structure were reduced in a gas mixture of 5% H{sub 2}-95% Ar at 800 Degree-Sign C for selected time periods in order to fabricate cermets with desired microstructure and composition, and to study their effects on the elastic properties at ambient and reactive atmospheres. It appears that 2 h of exposure to the reducing conditions is enough to reduce {approx}80% of NiO with an enhanced porosity value of 35%. The Ni-8YSZ cermet phase formation in the anode was analyzed with X-ray diffraction (XRD) in correlation with its microstructure. The elastic properties were determined after the reduction, at room and elevated temperatures using the impulse excitation technique. At room temperature the decrease in the Young's modulus was about 44% (after 8 h of reduction) and can be attributed mainly to the changes in the microstructure, particularly the increase in porosity from {approx}12% to 37%. Young's moduli of the as-received precursor and reduced anodes were evaluated as a function of temperature in air and reducing atmosphere. The results were explained in correlation to the initial porosity, composition and oxidation of Ni at the elevated temperatures.

36 MATERIALS SCIENCE↗