Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “real”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Using dual-energy x-ray imaging to enhance automated lung tumor tracking during real-time adaptive radiotherapy

Purpose: Real-time, markerless localization of lung tumors with kV imaging is often inhibited by ribs obscuring the tumor and poor soft-tissue contrast. This study investigates the use of dual-energy imaging, which can generate radiographs with reduced bone visibility, to enhance automated lung tumor tracking for real-time adaptive radiotherapy. Methods: kV images of an anthropomorphic breathing chest phantom were experimentally acquired and radiographs of actual lung cancer patients were Monte-Carlo-simulated at three imaging settings: low-energy (70 kVp, 1.5 mAs), high-energy (140 kVp, 2.5 mAs, 1 mm additional tin filtration), and clinical (120 kVp, 0.25 mAs). Regular dual-energy images were calculated by weighted logarithmic subtraction of high- and low-energy images and filter-free dual-energy images were generated from clinical and low-energy radiographs. The weighting factor to calculate the dual-energy images was determined by means of a novel objective score. The usefulness of dual-energy imaging for real-time tracking with an automated template matching algorithm was investigated. Results: Regular dual-energy imaging was able to increase tracking accuracy in left–right images of the anthropomorphic phantom as well as in 7 out of 24 investigated patient cases. Tracking accuracy remained comparable in three cases and decreased in five cases. Filter-free dual-energy imaging was only able to increase accuracy in 2 out of 24 cases. In four cases no change in accuracy was observed and tracking accuracy worsened in nine cases. In 9 out of 24 cases, it was not possible to define a tracking template due to poor soft-tissue contrast regardless of input images. The mean localization errors using clinical, regular dual-energy, and filter-free dual-energy radiographs were 3.85, 3.32, and 5.24 mm, respectively. Tracking success was dependent on tumor position, tumor size, imaging beam angle, and patient size. Conclusions: This study has highlighted the influence of patient anatomy on the success rate of real-time markerless tumor tracking using dual-energy imaging. Additionally, the importance of the spectral separation of the imaging beams used to generate the dual-energy images has been shown.

60 APPLIED LIFE SCIENCES↗

SU-F-J-44: Development of a Room Laser Based Real-Time Alignment Monitoring System Using An Array of Photodiodes

Purpose: To develop a real-time alignment monitoring system (RAMS) to compensate for the limitations of the conventional room laser based alignment system, and to verify the feasibility of the RAMS. Methods: The RAMS was composed of a room laser sensing array (RLSA), an analog-todigital converter, and a control PC. In the RLSA, seven photodiodes (each in 1 mm width) are arranged in a pattern that the RAMS provides alignment in 1 mm resolution. It works based on detecting laser light aligned on one of photodiodes. When misaligned, the laser would match with different photodiode(s) giving signal at unexpected location. Thus, how much displaced can be determined. To verify the reproducibility of the system with respect to time as well as repeated set-ups, temporal reproducibility and repeatability test was conducted. The accuracy of the system was tested by obtaining detection signals with varying laser-match positions. Results: The signal of the RAMS was found to be stable with respect to time. The repeatability test resulted in a maximum coefficient of variance of 1.14%, suggesting that the signal of the RAMS was stable over repeated set-ups. In the accuracy test, signals between when the laser was aligned and notaligned with any of sensors could be distinguished by signal intensity. The signals of not-aligned sensors were always below 75% of the signal of the aligned sensor. It was confirmed that the system could detect 1 mm of movement by monitoring the pattern of signals, and could observe the movement of the system in real-time. Conclusion: We developed a room laser based alignment monitoring system. The feasibility test verified that the system is capable of quantitative alignment monitoring in real time. The system is relatively simple, not expensive, and considered to be easily incorporated into conventional room laser systems for real-time alignment monitoring. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-91: Development of Real Time Abdominal Compression Force (ACF) Monitoring System

Purpose: Hard-plate based abdominal compression is known to be effective, but no explicit method exists to quantify abdominal compression force (ACF) and maintain the proper ACF through the whole procedure. In addition, even with compression, it is necessary to do 4D CT to manage residual motion but, 4D CT is often not possible due to reduced surrogating sensitivity. In this study, we developed and evaluated a system that both monitors ACF in real time and provides surrogating signal even under compression. The system can also provide visual-biofeedback. Methods: The system developed consists of a compression plate, an ACF monitoring unit and a visual-biofeedback device. The ACF monitoring unit contains a thin air balloon in the size of compression plate and a gas pressure sensor. The unit is attached to the bottom of the plate thus, placed between the plate and the patient when compression is applied, and detects compression pressure. For reliability test, 3 volunteers were directed to take several different breathing patterns and the ACF variation was compared with the respiratory flow and external respiratory signal to assure that the system provides corresponding behavior. In addition, guiding waveform were generated based on free breathing, and then applied for evaluating the effectiveness of visual-biofeedback. Results: We could monitor ACF variation in real time and confirmed that the data was correlated with both respiratory flow data and external respiratory signal. Even under abdominal compression, in addition, it was possible to make the subjects successfully follow the guide patterns using the visual biofeedback system. Conclusion: The developed real time ACF monitoring system was found to be functional as intended and consistent. With the capability of both providing real time surrogating signal under compression and enabling visual-biofeedback, it is considered that the system would improve the quality of respiratory motion management in radiation therapy. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-559: High-Resolution Scintillating Fiber Array for In-Vivo Real-Time SRS and SBRT Patient QA

Purpose: A high-resolution scintillating fiber detector was built for in-vivo real-time patient specific quality assurance (QA). The detector is designed for stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS) to monitor treatment delivery and detect real-time deviations from planned dose to increase patient safety and treatment accuracy. Methods: The detector consists of two high-density scintillating fiber arrays layered to form an X-Y grid which can be attached to the accessory tray of a medical linac for SBRT and cone SRS treatment QA. Fiber arrays consist of 128 scintillating fibers embedded within a precision-machined, high-transmission polymer substrate with 0.8mm pitch. The fibers are coupled on both ends to high-sensitivity photodetectors and the output is recorded through a high-speed analog-to-digital converter to capture the linac pulse sequence as treatment delivery progresses. The detector has a software controlled 360 degree rotational system to capture angular beam projections for high-resolution beam profile reconstruction. Results: The detector was validated using SRS cone sizes from 6mm to 34mm and MLC defined field sizes from 5×5mm2 to 100×100mm2. The detector output response is linear with dose and is dose rate independent. Each field can be reconstructed accurately with a spatial resolution of 0.8mm and the current beam output is displayed every 50msec. Dosimetric errors of 1% with respect to the treatment plan can be identified and clinically significant deviations from the expected treatment can be displayed in real-time to alert the therapists. Conclusion: The high resolution detector is capable of reconstructing beam profiles in real-time with submillimeter resolution and 1% dose resolution. This system has the ability to project in-vivo both spatial and dosimetric errors during SBRT and SRS treatments when only a non-clinically significant fraction of the intended dose was delivered. The device has the potential to establish new standards for in-vivo patient specific QA.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-11: Feasibility Study of Markerless Tracking Using Dual Energy Fluoroscopic Images for Real-Time Tumor-Tracking Radiotherapy System

Purpose: The new real-time tumor-tracking radiotherapy (RTRT) system was installed in our institution. This system consists of two x-ray tubes and color image intensifiers (I.I.s). The fiducial marker which was implanted near the tumor was tracked using color fluoroscopic images. However, the implantation of the fiducial marker is very invasive. Color fluoroscopic images enable to increase the recognition of the tumor. However, these images were not suitable to track the tumor without fiducial marker. The purpose of this study was to investigate the feasibility of markerless tracking using dual energy colored fluoroscopic images for real-time tumor-tracking radiotherapy system. Methods: The colored fluoroscopic images of static and moving phantom that had the simulated tumor (30 mm diameter sphere) were experimentally acquired using the RTRT system. The programmable respiratory motion phantom was driven using the sinusoidal pattern in cranio-caudal direction (Amplitude: 20 mm, Time: 4 s). The x-ray condition was set to 55 kV, 50 mA and 105 kV, 50 mA for low energy and high energy, respectively. Dual energy images were calculated based on the weighted logarithmic subtraction of high and low energy images of RGB images. The usefulness of dual energy imaging for real-time tracking with an automated template image matching algorithm was investigated. Results: Our proposed dual energy subtraction improve the contrast between tumor and background to suppress the bone structure. For static phantom, our results showed that high tracking accuracy using dual energy subtraction images. For moving phantom, our results showed that good tracking accuracy using dual energy subtraction images. However, tracking accuracy was dependent on tumor position, tumor size and x-ray conditions. Conclusion: We indicated that feasibility of markerless tracking using dual energy fluoroscopic images for real-time tumor-tracking radiotherapy system. Furthermore, it is needed to investigate the tracking accuracy using proposed dual energy subtraction images for clinical cases.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-12: Real-Time Organ Motion Monitoring Using Ultrasound and KV Fluoroscopy During Lung SBRT Delivery

Purpose: Real-time ultrasound monitoring during SBRT is advantageous in understanding and identifying motion irregularities which may cause geometric misses. In this work, we propose to utilize real-time ultrasound to track the diaphragm in conjunction with periodical kV fluoroscopy to monitor motion of tumor or landmarks during SBRT delivery. Methods: Transabdominal Ultrasound (TAUS) b-mode images were collected from 10 healthy volunteers using the Clarity Autoscan System (Elekta). The autoscan transducer, which has a center frequency of 5 MHz, was utilized for the scans. The acquired images were contoured using the Clarity Automatic Fusion and Contouring workstation software. Monitoring sessions of 5 minute length were observed and recorded. The position correlation between tumor and diaphragm could be established with periodic kV fluoroscopy periodically acquired during treatment with Elekta XVI. We acquired data using a tissue mimicking ultrasound phantom with embedded spheres placed on a motion stand using ultrasound and kV Fluoroscopy. MIM software was utilized for image fusion. Correlation of diaphragm and target motion was also validated using 4D-MRI and 4D-CBCT. Results: The diaphragm was visualized as a hyperechoic region on the TAUS b-mode images. Volunteer set-up can be adjusted such that TAUS probe will not interfere with treatment beams. A segment of the diaphragm was contoured and selected as our tracking structure. Successful monitoring sessions of the diaphragm were recorded. For some volunteers, diaphragm motion over 2 times larger than the initial motion has been observed during tracking. For the phantom study, we were able to register the 2D kV Fluoroscopy with the US images for position comparison. Conclusion: We demonstrated the feasibility of tracking the diaphragm using real-time ultrasound. Real-time tracking can help in identifying such irregularities in the respiratory motion which is correlated to tumor motion. We also showed the feasibility of acquiring 2D KV Fluoroscopy and registering the images with Ultrasound.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-AB-202-08: A Robust Real-Time Surface Reconstruction Method On Point Clouds Captured From a 3D Surface Photogrammetry System

Purpose: Surface photogrammetry (e.g. VisionRT, C-Rad) provides a noninvasive way to obtain high-frequency measurement for patient motion monitoring in radiotherapy. This work aims to develop a real-time surface reconstruction method on the acquired point clouds, whose acquisitions are subject to noise and missing measurements. In contrast to existing surface reconstruction methods that are usually computationally expensive, the proposed method reconstructs continuous surfaces with comparable accuracy in real-time. Methods: The key idea in our method is to solve and propagate a sparse linear relationship from the point cloud (measurement) manifold to the surface (reconstruction) manifold, taking advantage of the similarity in local geometric topology in both manifolds. With consistent point cloud acquisition, we propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, building the point correspondences by the iterative closest point (ICP) method. To accommodate changing noise levels and/or presence of inconsistent occlusions, we further propose a modified sparse regression (MSR) model to account for the large and sparse error built by ICP, with a Laplacian prior. We evaluated our method on both clinical acquired point clouds under consistent conditions and simulated point clouds with inconsistent occlusions. The reconstruction accuracy was evaluated w.r.t. root-mean-squared-error, by comparing the reconstructed surfaces against those from the variational reconstruction method. Results: On clinical point clouds, both the SR and MSR models achieved sub-millimeter accuracy, with mean reconstruction time reduced from 82.23 seconds to 0.52 seconds and 0.94 seconds, respectively. On simulated point cloud with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent performance despite the introduced occlusions. Conclusion: We have developed a real-time and robust surface reconstruction method on point clouds acquired by photogrammetry systems. It serves an important enabling step for real-time motion tracking in radiotherapy. This work is supported in part by NIH grant R01 CA169102-02.

60 APPLIED LIFE SCIENCES↗

Seeing real-space dynamics of liquid water through inelastic x-ray scattering

Water is ubiquitous on earth, but we know little about the real-space motion of molecules in liquid water. We demonstrate that high-resolution inelastic x-ray scattering measurement over a wide range of momentum and energy transfer makes it possible to probe real-space, real-time dynamics of water molecules through the so-called Van Hove function. Water molecules are found to be strongly correlated in space and time with coupling between the first and second nearest-neighbor molecules. The local dynamic correlation of molecules observed here is crucial to a fundamental understanding of the origin of the physical properties of water, including viscosity. The results also suggest that the quantum-mechanical nature of hydrogen bonds could influence its dynamics. Finally, the approach used here offers a powerful experimental method for investigating real-space dynamics of liquids.

36 MATERIALS SCIENCE↗

DERMS-RT (Distributed Energy Resource Management Solution using Real-Time Optimization) [SWR-20-46]

DERMS-RT provides a distributed energy resource management solution using real-time optimization to control different types of distributed energy resources (DERs) — such as rooftop PVs, battery energy storage systems, HVAC loads, electric water heater loads, and EV charging loads, and use these DERs to provide distribution voltage regulation and peak demand management services. The control approach implemented by DERM-RT is developed based on the real-time optimal power flow and distributed control previously developed by NREL researchers. The software codes are designed to provide modular DER management solution that can be easily applied to control heterogeneous DERs in distribution grids in coordination with centralized utility management systems. Also, DERMS-RT provides application programming interface (API) to extract useful grid model information from an open-source power system simulation software, use the information to solve the optimization problem, and apply the optimal set-points to the controlled DERs. In this way, DERMS-RT provides a plug-and-play function for implementing the real-time DER control on different utility system models, and it can be used as a simulation testbed to demonstrate the impact of real-time DER optimization on improving grid operations.

Ding, Fei↗

Real-time data analysis for medical diagnosis using FPGA-accelerated neural networks

Real-time analysis of patient data during medical procedures can provide vital diagnostic feedback that significantly improves chances of success. With sensors becoming increasingly fast, frameworks such as Deep Neural Networks are required to perform calculations within the strict timing constraints for real-time operation. However, traditional computing platforms responsible for running these algorithms incur a large overhead due to communication protocols, memory accesses, and static (often generic) architectures. In this work, we implement a low-latency Multi-Layer Perceptron (MLP) processor using Field Programmable Gate Arrays (FPGAs). Unlike CPUs and Graphics Processing Units (GPUs), our FPGA-based design can directly interface sensors, storage devices, display devices and even actuators, thus reducing the delays of data movement between ports and compute pipelines. Moreover, the compute pipelines themselves are tailored specifically to the application, improving resource utilization and reducing idle cycles. We demonstrate the effectiveness of our approach using mass-spectrometry data sets for real-time cancer detection. We demonstrate that correct parameter sizing, based on the application, can reduce latency by 20% on average. Furthermore, we show that in an application with tightly coupled data-path and latency constraints, having a large amount of computing resources can actually reduce performance. Using mass-spectrometry benchmarks, we show that our proposed FPGA design outperforms both CPU and GPU implementations, with an average speedup of 144x and 21x, respectively. In our work, we demonstrate the importance of application-specific optimizations in order to minimize latency and maximize resource utilization for MLP inference. By directly interfacing and processing sensor data with ultra-low latency, FPGAs can perform real-time analysis during procedures and provide diagnostic feedback that can be critical to achieving higher percentages of successful patient outcomes.

60 APPLIED LIFE SCIENCES↗

Superior signal persistence of circularly polarized light in polydisperse, real-world fog environments

Here, we present simulation results quantitatively showing that circularly polarized light persists in transmission through several real-world and model fog environments better than linearly polarized light over broad wavelength ranges from the visible through the infrared. We present results for polydisperse particle distributions from realistic and measured fog environments, comparing the polarization persistence of linear and circular polarization. Using a polarization-tracking Monte Carlo program, we simulate polarized light propagation through four MODTRAN fog models (moderate and heavy radiation fog and moderate and heavy advection fog) and four real-world measured fog particle distributions (Garland measured radiation and advection fogs, Kunkel measured advection fog, and Sandia National Laboratories’ Fog Facility’s fog). Simulations were performed for each fog environment with wavelengths ranging from 0.4 to 12 µm for increasing optical thicknesses of 5, 10, and 15 (increasing fog density or sensing range). Circular polarization persists superiorly for all optical wavelength bands from the visible to the long-wave infrared in nearly all fog types for all optical thicknesses. Throughout our analysis, we show that if even a small percentage of a fog’s particle size distribution is made up of large particles, those particles dominate the scattering process. In nearly all real-world fog situations, these large particles and their dominant scattering characteristics are present. Larger particles are predominantly forward-scattering and contribute to circular polarization’s persistence superiority over broad wavelength ranges and optical thicknesses/range. Circularly polarized light can transmit over 30% more signal in its intended state compared to linearly polarized light through real-world fog environments. This work broadens the understanding of how circular polarization persists through natural fog particle distributions with natural variations in mode particle radius and single or bimodal characteristics.

47 OTHER INSTRUMENTATION↗

Xopt and Badger: a machine learning ecosystem for real-time accelerator control and optimization

Machine learning (ML)-based black-box optimization algorithms have demonstrated significant improvements in accelerator optimization speed, often by orders of magnitude. However, deploying these algorithms in real-time facility control remains challenging due to the specialized expertise and infrastructure required. To bridge this gap, we introduce the Xopt ecosystem, a versatile suite of tools designed to make advanced ML-based optimization accessible to the broader accelerator community. This ecosystem includes Xopt, a modular Python framework that facilitates the integration of ML-based optimization algorithms with arbitrary control problems, and Badger, a graphical user interface built on top of Xopt, which enables seamless deployment of ML algorithms in real-time control systems. The Xopt ecosystem has been successfully applied towards solving challenging real-time control problems at leading international accelerator facilities, including SLAC, LBNL, Argonne, Fermilab, BNL, DESY, and ESRF, demonstrating its effectiveness in real-world optimization tasks. In this presentation, we provide an overview of Xopt’s capabilities and illustrate its impact through case studies from SLAC accelerator facilities including LCLS, LCLS-II, and FACET-II.

Roussel, Ryan [SLAC]↗

Advanced Kalman Filter for Real-Time Responsiveness in Complex Systems

Complex engineering systems pose fundamental challenges in real-time operations and control because they are highly dynamic systems consisting of a large number of elements with severe nonlinearities and discontinuities. Today’s tools for real-time complex system operations are mostly based on steady state models, unable to capture the dynamic nature and too slow to prevent system failures. We developed advanced Kalman filtering techniques and the formulation of dynamic state estimation using Kalman filtering techniques to capture complex system dynamics in aiding real-time operations and control. In this work, we looked at complex system issues including severe nonlinearity of system equations, discontinuities caused by system controls and network switches, sparse measurements in space and time, and real-time requirements of power grid operations. We sought to bridge the disciplinary boundaries between Computer Science and Power Systems Engineering, by introducing methods that leverage both existing and new techniques. While our methods were developed in the context of electrical power systems, they should generalize to other large-scale scientific and engineering applications.

97 MATHEMATICS AND COMPUTING↗

Using architecture information and real-time resource state to reduce power consumption and communication costs in parallel applications.

As computer systems grow in both size and complexity, the need for applications and run-time systems to adjust to their dynamic environment also grows. The goal of the RAAMP LDRD was to combine static architecture information and real-time system state with algorithms to conserve power, reduce communication costs, and avoid network contention. We devel- oped new data collection and aggregation tools to extract static hardware information (e.g., node/core hierarchy, network routing) as well as real-time performance data (e.g., CPU uti- lization, power consumption, memory bandwidth saturation, percentage of used bandwidth, number of network stalls). We created application interfaces that allowed this data to be used easily by algorithms. Finally, we demonstrated the benefit of integrating system and application information for two use cases. The first used real-time power consumption and memory bandwidth saturation data to throttle concurrency to save power without increasing application execution time. The second used static or real-time network traffic information to reduce or avoid network congestion by remapping MPI tasks to allocated processors. Results from our work are summarized in this report; more details are available in our publications [2, 6, 14, 16, 22, 29, 38, 44, 51, 54].

Brandt, James M.↗

Making the Grid "Smart" Through "Smart" Microgrids: Real-Time Power Management of Microgrids with Multiple Distributed Generation Sources Using Intelligent Control

In this Project we collaborated with two DOE National Laboratories, Pacific Northwest National Lab (PNNL) and Lawrence Berkeley National Lab (LBL). Dr. Hammerstrom of PNNL initially supported our project and was on the graduate committee of one of the Ph.D. students (graduated in 2014) who was supported by this project. He is also a committee member of a current graduate student of the PI who was supported by this project in the last two years (August 2014-July 2016). The graduate student is now supported be the Electrical and Computer Engineering (ECE) Department at Montana State University (MSU). Dr. Chris Marney of LBL provided actual load data, and the software WEBOPT developed at LBL for microgrid (MG) design for our project. NEC-Labs America, a private industry, also supported our project, providing expert support and modest financial support. We also used the software “HOMER,” originally developed at the National Renewable Energy Laboratory (NREL) and the most recent version made available to us by HOMER Energy, Inc., for MG (hybrid energy system) unit sizing. We compared the findings from WebOpt and HOMER and designed appropriately sized hybrid systems for our case studies. The objective of the project was to investigate real-time power management strategies for MGs using intelligent control, considering maximum feasible energy sustainability, reliability and efficiency while, minimizing cost and undesired environmental impact (emissions). Through analytic and simulation studies, we evaluated the suitability of several heuristic and artificial-intelligence (AI)-based optimization techniques that had potential for real-time MG power management, including genetic algorithms (GA), ant colony optimization (ACO), particle swarm optimization (PSO), and multi-agent systems (MAS), which is based on the negotiation of smart software-based agents. We found that PSO and MAS, in particular, distributed MAS, were more efficient and better suited for our work. We investigated the following: • Intelligent load control - demand response (DR) - for frequency stabilization in islanded MGs (partially supported by PNNL). • The impact of high penetration of solar photovoltaic (PV)-generated power at the distribution level (partially supported by PNNL). • The application of AI approaches to renewable (wind, PV) power forecasting (proposed by the reviewers of our proposal). • Application of AI approaches and DR for real-time MG power management (partially supported by NEC Labs-America) • Application of DR in dealing with the variability of wind power • Real-time MG power management using DR and storage (partially supported by NEC Labs-America) • Application of DR in enhancing the performance of load-frequency controller • MAS-based whole-sale and retail power market design for smart grid A

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Efficiency and the Real Estate Lifecycle: Stakeholder Perspectives

This report characterizes opportunities and pitfalls for leveraging key building lifecycle “events” as intervention points to enhance energy efficiency in real estate portfolios. It is based primarily on 33 interviews conducted with key industry stakeholders, including commercial real estate owners, operators, tenants, investors, developers, vendors, architecture/engineering firms, and construction managers. We focus on the following key events in the real estate life cycle because they are likely to present an opportunity for energy efficiency improvements: a) purchase or sale of a property; b) renovation; c) major equipment replacement; d) lease turnover or renewal; and e) refinancing. The stakeholder interviews covered business roles and processes, priorities, and sensitivities in these commercial real estate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analyze the real-time performance of the optimized fiber-PTR instrument

An instrument to perform in-reactor, real-time thermal property measurements of nuclear fuels and materials was recently designed, optimized, and tested at Massachusetts Institute of Technology Research Reactor. It was the second insertion experiments of a total of two rounds. Here we report the collection and analysis of the real-time captured thermal diffusivity data on the preloaded SiC. With the optimized design, the instrument temperature had been successfully raised as we expected. Only one probe (the top one) returned real-time thermal diffusivity in a time span of approximately two days. Measured thermal diffusivity of the preloaded SiC was significantly lower than the literature value at the same temperature, indicating a significant influence from the irradiation induced microstructure damage. Meanwhile, the real-time thermal diffusivity value continuously reduced with time, indicating the dynamic microstructure evolution. The possible reasons of the probes that did not return data were hypothesized. The further optimization of the instrument with the objective to improve the measurement accuracy and instrument survivability is also discussed.

36 MATERIALS SCIENCE↗

Intelligent Experiments through Real-Time AI: Fast Data Processing and Autonomous Detector Control for High-Energy Nuclear Experiments

The aim of this project is to develop software and hardware for fast real-time data processing and autonomous detector control and calibration for the sPHENIX and the future EIC experiments. Below summarizes Georgia Tech team efforts in the past year: 1. We developed a real-time clustering algorithm and FPGA-based pipeline architecture for processing fired pixel data from ALPIDE sensors in sPHENIX experiments. Our Columnar Clustering Co-Design introduces a hardware-aware, stream-friendly approach that segments pixel data by column pairs using a Column Pair Clustering (CPC) strategy, followed by Cluster Stitching to merge adjacent subclusters. Implemented in Vitis HLS, the pipeline comprises five stages—read-in, subclustering, stitching, analysis, and write-out—connected by tagged HLS streams with custom end-of-event signaling for robust synchronization. We designed a pipelined dataflow model optimized for throughput, low latency, and minimal buffering, enabling scalable clustering across events of arbitrary size. Our system maintains spatial precision via center-of-mass and shape key extraction and efficiently handles edge cases such as fragmented or nested clusters. Compared against DBSCAN in both software and hardware, our approach demonstrates competitive performance under FPGA constraints. 2. We also conducted a comprehensive algorithm-to-hardware co-design of connected component analysis tailored for sPHENIX experiments, focusing on real-time, low-latency processing using FPGAs and High-Level Synthesis (HLS). Starting from a Python-based particle tracking pipeline, the team translated the core logic—graph traversal via DFS and Union-Find—into an HLS-compatible C++ model, replacing dynamic memory and recursion with static arrays and pipelined control flow. The final design includes a fully streamed and dataflow-compatible Union-Find kernel optimized across five iterations, incorporating loop pipelining, array partitioning, AXI/FIFO interface tuning, and function flattening. Experimental results show up to 14.8× speedup over the CPU baseline, reducing per-graph latency to 1.58 μs and demonstrating strong resource efficiency with only ~7k LUTs and zero BRAM usage. The design maintains functional correctness against the Python reference using a Python-based C-simulation framework and Mean Squared Error metrics. This work validates the potential of HLS-driven FPGA designs for edge-level HEP data acquisition, laying a scalable foundation for future integration with real-time detector pipelines and multi-graph processing systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗