Spectral and Microclimate Measurements in Relation to Gold-Standard Methods Field Campaign Report

Arable is an agricultural data and analytics company offering an Internet of things (IOT)-enabled irrigation management tool, weather station, and crop monitor: the Arable Mark. The device synthesizes both climate and plant data to produce actionable insights on natural resource management, mainly commercial agriculture at any scale. Arable collected 11 months of microclimate and radiometric data at the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) observatory to compare measurements of the Arable Mark to the ARM-SGP gold-standard sensors, and for demonstrating the ease of installation and system value to stakeholders. A member from Arable labs installed the device on January 10, 2018, at the ARM facilities and the site managers were in charge of maintaining the sensors in a clean state until the unit’s removal on January 15, 2019. The sampling was positively uneventful, except for a period during the winter when the device stopped posting data for about one week. The verdict was that the equipment required an external solar panel to stay powered through the shorter days of winter. A solar panel was shipped to the SGP, and the unit came back to full charge to continue sending data for the rest of the sampling period. The main goal of the project is to use the data collected by the Arable Mark and build a model that can establish a close relationship with the current methodologies applied to measure ecosystem response to environmental changes. During the sampling period, our team discovered that there was a drift in some of the meteorological data and also in the radiometry, so all efforts are focused into the development of models that would reduce the errors in the reported values.

Southern Great Plains, evapotranspiration, photosy↗

Integrated Optical Probes

Optical probes used in velocimetry measurements have typically been individual probes that collect data for a single diagnostic at a single point. These probes have been used in diagnostics such as VISAR, PDV, and radiometry, which measure surface velocity, temperature, and other characteristics. When separate probes are used for these measurements, the different diagnostic points measured must be significantly separated. We have developed integrated probes that collect data for multiple optical diagnostics; these probes measure points in close proximity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral Methods of Remote-Sensing Monitoring of Radioactive Substances and Toxic Chemicals

The physical principles of passive and active methods of remote-sensing monitoring of radioactive substances and toxic chemicals in accidental emissions (leaks) at nuclear fuel cycle objects are examined. The analytical possibilities of the most sensitive methods of remote-sensing monitoring, which are based on the advances made in UV and microwave range radiometry, laser IR-absorption spectroscopy, laser-induced fluorescence, and laser spark emission spectrometry, are discussed. The prospects for the development of spectral methods of remote-sensing monitoring in different ranges are analyzed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ability to Simulate Absorption and Melt Pool Dynamics for Laser Melting of Bare Aluminum Plate: Results and Insights from the 2022 Asynchronous AM-Bench Challenge

The 2022 Asynchronous AM-Bench challenge was designed to test the ability of simulations to accurately predict laser power absorption as well as various melt pool behaviors (width, depth, and solidification) during laser melting of solid metal during stationary and scanned laser illumination. In this challenge, participants were asked to predict a series of experimental outcomes. Experimental data were obtained from a series of experiments performed at the Advanced Photon Source at Argonne National Laboratories in 2019. These experiments combined integrating sphere radiometry with high-speed X-ray imaging, allowing for the simultaneous recording of absolute laser power absorption and two-dimensional, projected images of the melt pool. All challenge problems were based on experiments using bare aluminum solid metal. Participants were provided with pertinent experimental information like laser power, scan speed, laser spot size, and material composition. Additionally, participants were given absorptance and X-ray imaging data from stationary and scanned laser experiments on solid Ti–6Al–4V that could be used for testing their models before attempting challenge problems. In total, this challenge received 56 submissions from eight different research groups for eight individual challenge problems. The data for this challenge, and associated information, are available for download from the NIST Public Data Repository. This paper summarizes the results from the 2022 Asynchronous AM-Bench challenge as well as discusses the lessons learned to help inform future challenges.

36 MATERIALS SCIENCE↗

Impact of Janssen effect on thermal transport in granular flow

Using a modulated photothermal radiometry (MPR) technique capable of measuring thermal transport in particle beds, we find asymptotically increasing effective thermal conductivity and decreasing near-wall thermal resistance along gravity-driven downward granular flows through a 1-meter-long narrow vertical channel owing to the Janssen effect. The Janssen effect is confirmed by similar asymptotic trends from particle bed apparent mass measurements as well as separate MPR heat transfer measurements on stationary particle beds under compression at different heights of the channel with and without pressure screening. Furthermore, local heat transfer coefficient along the 1-meter-long channel was modeled based on measured spatially resolved thermal conductivity and near-wall thermal resistance due to the Janssen effect. This work reveals for the first time the impact of the over century-old Janssen effect on heat transfer in granular media. Furthermore, the results from this work can lead to a better understanding of heat transfer in granular flow.

14 SOLAR ENERGY↗

Optical metrology at the NSLS-II

Rapid progress in synchrotron optics performance places a high demand on optical characterization techniques used to validate surface parameters prior to installation of the X-ray optics. It is now necessary to characterize optical surface figure and slope errors and roughness on meter-long optics over spatial frequencies as short as 0.1 {micro}m The new NSLS-II Optical Metrology Laboratory (OML) includes instruments for measuring: (1) long spatial frequency figure errors with a ZYGO MST Fizeau-type 4* interferometer, capable of 0.1 nm sensitivity, (2) mid spatial frequencies with an upgraded ZYGO NewView 6300 white light interferometric microscope, capable of reaching 0.1 nm accuracy at a lateral resolution of 1 {micro}m, (3) high frequency roughness with an AFM (Nanosurf AG) with linearity better than 0.2% over the 80 {micro}m measurement area and sensitivity approaching 0.01 nm, and (4) slope errors with a long trace profiler currently under development that will be able to reach 50 nrad slope error accuracy. At present, the OML supports the NSLS-II R&D efforts and provides ongoing testing for NSLS optics. Future plans include the construction of a specialized metrology beamline for at-wavelength metrology, radiometry, in situ surface figuring, crystal optics characterization, and instrumentation development.

43 PARTICLE ACCELERATORS↗

Performance of Landsat-8 and Sentinel-2 surface reflectance products for river remote sensing retrievals of chlorophyll-a and turbidity

Rivers and other freshwater systems play a crucial role in ecosystems, industry, transportation and agriculture. Despite the > 40 years of inland water observations made possible by optical remote sensing, a standardized reflectance product for inland waters is yet forthcoming. The aim of this work is to compare the standard USGS land surface reflectance product to two Landsat-8 and Sentinel-2 aquatic remote sensing reflectance products over the Amazon, Columbia and Mississippi rivers. Landsat-8 reflectance products from all three routines are then evaluated for their comparative performance in retrieving chlorophyll-a and turbidity in reference to ship- borne, underway in situ validation measurements. The land surface product shows the best agreement (4% Mean Absolute Percent Difference) with field measurements of radiometry collected on the Amazon River and gen- erates 36% higher reflectance values in the visible bands compared to aquatic methods (ACOLITE and SeaDAS) with larger differences between land and aquatic products observed in Sentinel-2 (0.01sr-1) compared to Landsat-8 (0.001 sr-1). Choice of atmospheric correction routine can bias Landsat-8 retrievals of chlorophyll-a and turbidity by as much as 59% and 35% respectively. Using a more restrictive time window for matching in situ and satellite imagery can reduce differences by 5–31% depending on correction technique. This work highlights the challenges of satellite retrievals over rivers and underscores the need for future optical and biogeochemical research aimed at improving our understanding of the absorbing and scattering properties of river water and their relationships to remote sensing reflectance.

Amazon↗

Mesospheric temperature and circulation response to the Hunga Tonga-Hunga-Ha'apai volcanic eruption

The Hunga Tonga Hunga-Ha'apai (HTHH) volcanic eruption on 15 January 2022 injected water vapor and SO 2 into the stratosphere. Several months after the eruption, significantly stronger westerlies, and a weaker Brewer-Dobson circulation developed in the stratosphere of the Southern Hemisphere and were accompanied by unprecedented temperature anomalies in the stratosphere and mesosphere. In August 2022, the Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) satellite instrument observed record-breaking temperature anomalies in the stratosphere and mesosphere that alternate signs with altitude. Ensemble simulations carried out with the Whole Atmosphere Community Climate Model (WACCM6) indicate that the strengthening of the stratospheric westerlies explains the mesospheric temperature changes. The stronger westerlies cause stronger westward gravity wave drag in the mesosphere. Although the enhanced gravity wave drag is partly balanced by a weakening of planetary wave forcing, the net result is an acceleration of the mesospheric mean meridional circulation. The stronger mesospheric circulation, in turn, plays a dominant role in driving the changes in mesospheric temperatures. This study highlights the impact of large volcanic eruptions on middle atmospheric dynamics and provides insight into their long-term effects in the mesosphere. On the other hand, we could not discern a clear mechanism for the observed changes in stratospheric circulation. In fact, an examination of the WACCM ensemble reveals that not every member reproduces the large changes observed by SABER. We conclude that there is a stochastic component to the stratospheric response to the HTHH eruption.

58 GEOSCIENCES↗

Deep learning approaches for instantaneous laser absorptance prediction in additive manufacturing

Abstract The quantification of absorbed light is essential for understanding laser-material interactions and melt pool dynamics in order to minimize defects in additively manufactured metal components. The geometry of a vapor depression formed during laser melting is closely related to laser energy absorption. This relationship has been observed by the state-of-the-art in situ high-speed synchrotron X-ray visualization and integrating sphere radiometry. These two techniques create a temporally resolved dataset consisting of vapor depression images and corresponding laser absorptance. In this work, we propose two different approaches to predict instantaneous laser absorptance. The end-to-end approach uses deep convolutional neural networks to learn implicit features of X-ray images automatically and predict the laser energy absorptance. The two-stage approach uses a semantic segmentation model to engineer geometric features and predict absorptance using classical regression models. While having distinct advantages, both approaches achieved a consistently low mean absolute error of less than 3.3%.

Chemistry↗

Influence of laser beam size on measurement sensitivity of thermophysical property gradients in layered structures using thermal-wave techniques

The influence of the photothermal laser source beam size on the measurement sensitivity of layered systems using photothermal radiometry (PTR) is presented. Based on an appropriate theoretical model, widely different behaviors of the photothermal amplitude and phase in terms of combinations of thermophysical properties (i.e., thermal conductivity and thermal diffusivity) between a thin coating and the substrate are observed. The beam size effect on PTR measurement sensitivity is theoretically examined and experimentally demonstrated using a carbonitrided C1018 steel sample. The experimental results of using a variable size laser beam for the carbonitrided C1018 sample validate the theoretical prediction, in which an expanded beam exhibits a much larger magnitude change in both amplitude and phase as a function of frequency than measurements with a focused beam. The fitted thermal conductivity and thermal diffusivity based on the assumed industrially relevant range of effective hardness case depth gives the approximate range of the change in thermal conductivity and thermal diffusivity of C1018 steels after the carbonitriding process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiant Flux of Near Field in Temperature Measurements

In this work we present a calculation of the radiant flux exiting from an object which is at a constant temperature. The flux calculation is based in the propagation model of irradiance and it permit to predict the small variations in measurements of infrared radiation sources when the pyrometer is going far from the source, this variation is known as distance effect. The classical radiometry defines the quantity radiance, which is used in temperature measurements of objects through the infrared radiation they emit. Unfortunately the radiance does not permit to take into account the variations of the radiant flux measured by the pyrometer due to the wave propagation of the radiation given that the radiance definition is based in ray propagation, the geometrical model. Due to the anterior in this work we present a radiant flux calculation using wave model and considering the approximation of the near field or Fresnel approximation. We show experimental results that confirm our proposal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A correlation electron cyclotron emission diagnostic and the importance of multifield fluctuation measurements for testing nonlinear gyrokinetic turbulence simulations

A correlation electron cyclotron emission (CECE) diagnostic has been used to measure local, turbulent fluctuations of the electron temperature in the core of DIII-D plasmas. This paper describes the hardware and testing of the CECE diagnostic and highlights the importance of measurements of multifield fluctuation profiles for the testing and validation of nonlinear gyrokinetic codes. The process of testing and validating such codes is critical for extrapolation to next-step fusion devices. For the first time, the radial profiles of electron temperature and density fluctuations are compared to nonlinear gyrokinetic simulations. The CECE diagnostic at DIII-D uses correlation radiometry to measure the rms amplitude and spectrum of the electron temperature fluctuations. Gaussian optics are used to produce a poloidal spot size with w{sub o}{approx}1.75 cm in the plasma. The intermediate frequency filters and the natural linewidth of the EC emission determine the radial resolution of the CECE diagnostic, which can be less than 1 cm. Wavenumbers resolved by the CECE diagnostic are k{sub {theta}}{<=}1.8 cm{sup -1} and k{sub r}{<=}4 cm{sup -1}, relevant for studies of long-wavelength turbulence associated with the trapped electron mode and the ion temperature gradient mode. In neutral beam heated L-mode plasmas, core electron temperature fluctuations in the region 0.5<r/a<0.9, increase with radius from {approx}0.5% to {approx}2%, similar to density fluctuations that are measured simultaneously with beam emission spectroscopy. After incorporating 'synthetic diagnostics' to effectively filter the code output, the simulations reproduce the characteristics of the turbulence and transport at one radial location r/a=0.5, but not at a second location, r/a=0.75. These results illustrate that measurements of the profiles of multiple fluctuating fields can provide a significant constraint on the turbulence models employed by the code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Raman and electron microscopy analysis of carbon nanotubes exposed to high power laser irradiance

High power laser radiometry requires efficient and damage-resistant detectors. The current study explores the evolving nature of carbon nanotube coatings for such detectors upon their exposure to incrementally increasing laser power levels. Electron microscopy images along with the D-band to G-band intensity ratios from the Raman spectra from eight irradiance levels are used to evaluate changes before and after the exposure. Electron microscopy images of the exposed multiwalled carbon nanotubes revealed the formation of intermittent pockets of moundlike structures at high power densities exceeding 11 kW/cm{sup 2}. Raman spectroscopy measurements also demonstrated higher values for the ratio of the D-band intensity to that of the G-band, suggesting the possible transformation of nanotubes into structurally different forms of carbon. Exposure to a sample of single-walled nanotubes did not demonstrate the evolution of structural changes, which could be due in part to the higher irradiance levels relative to the damage threshold, employed in the experiment.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

New plasma measurements with a multichannel millimeter-wave fluctuation diagnostic system in the DIII-D tokamak (invited)

A novel multichannel, tunable Doppler backscattering (DBS)/reflectometry system has recently been developed and applied to a variety of DIII-D plasmas. Either DBS or reflectometry can be easily configured for use in a wide range of plasma conditions using a flexible quasi-optical antenna system. The multiple closely spaced channels, when combined with other fluctuation diagnostic systems, have opened up new measurements of plasma properties. For example, the toroidal and fine-scale radial structure of coherent plasma oscillations, such as geodesic acoustic modes, have been probed simultaneously in the core of high temperature plasmas by applying correlation analysis between two toroidally separated DBS systems, as well as within the multichannel array. When configured as a reflectometer, cross-correlation with electron cyclotron emission radiometry has uncovered detailed information regarding the crossphase relationship between density and temperature fluctuations. The density-temperature crossphase measurement yields insight into the physics of tokamak turbulence at a fundamental level that can be directly compared with predictions from nonlinear gyrokinetic simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation of thermal plasma formation from thick aluminum surfaces by pulsed multimegagauss magnetic field

The thermal ionization of a thick metal surface by pulsed multimegagauss magnetic field has been examined experimentally. Thick 6061-alloy Al rods with initial radii (R{sub 0}) from 1.00 to 0.25 mm, larger than the magnetic field skin depth, are pulsed to 1.0 MA peak current in 100 ns. Surface fields (B{sub s}) rise at 30-80 MG/{mu}s and reach 1.5 and 4 MG, respectively. For this range of parameters, plasma forms at a threshold level of B{sub s}=2.2 MG. Novel load hardware ensures that plasma formation is thermal, by Ohmic or compression heating. Surface-plasma formation is conclusively indicated through radiometry, extreme ultraviolet spectroscopy, and gated imaging. When R{sub 0}=0.50 mm rods reach peak current, B{sub s}=3 MG, the surface temperature is 20 eV, and Al{sup 3+} and Al{sup 4+} spectra and surface instabilities are observed. In contrast, R{sub 0}=1.00 mm rod surfaces [B{sub s}(t)<2.2 MG] reach only 0.7 eV and remain extremely smooth, indicating that no plasma forms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Concentration Of Tritium In Urine And Internal Radiation Dose Estimation Of PTNBR Radiation Workers

The operation of Triga 2000 reactor in Nuclear Technology Center for Materials and Radiometry (PTNBR BATAN) normally produce tritium radionuclide which is the activation product of deuterium atom in reactor primary cooling water. According to previous monitoring, tritium was detected with the concentration of 8.236{+-}0.677 kBq/L and 1.704{+-}0.046 Bq/L in the primary cooling water and in reactor hall air, respectively. The tritium in reactor hall air chronically can be inhaled by the workers. In this research, tritium content in radiation workers' urine was determined to estimate the internal radiation doses received by the workers. About 50-100 mL of urine samples were collected from 48 PTNBR workers that is classified as 24 radiation workers and 24 administration staffs as a control. Urine samples of 25 mL were then prepared by active charcoal and KMnO{sub 4} addition and followed with complete distillation. The 2 mL of distillate was added with 13 mL scintillator, shaked vigorously and remained in cool and dark condition for about 24 hours. The tritium in the samples was then measured using liquid scintillation counter (LSC) for 1 hour. From the measurement results it was obtained that the tritium concentration in the urine of radiation workers were in the range of not detected and 5.191 Bq/mL, whereas in the administration staffs the concentration were between not detected and 4.607 Bq/mL. Internally radiation doses were calculated using the tritium concentration data, and it was found the averages about 0.602 {mu}Sv/year and 0.532 {mu}Sv/year for radiation workers and administration staffs, respectively. The doses received by the workers were lower than that of the permissible doses from tritium, i.e. 40 {mu}Sv/year.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental characterization of multiscale and multifield turbulence as a critical gradient threshold is surpassed in the DIII-D tokamak

A critical gradient for long wavelength (k{sub θ}ρ{sub s}≲0.4) electron temperature fluctuations has been observed in an experiment in the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 42, 614 (2002)], where below a threshold value of L{sub T{sub e}{sup −1}}=|∇T{sub e}|/T{sub e} electron temperature fluctuations are constant and above they steadily increase. Above the critical gradient, the electron heat flux inferred by power balance also increases rapidly. Critical gradients are a predicted attribute of turbulence arising from linear instabilities and are thought to be related to transport stiffness. The presented results are the first direct, systematic demonstration of critical gradient behavior in turbulence measurements in a tokamak. The experiment was performed by changing the deposition location of electron cyclotron heating shot-to-shot to locally scan L{sub T{sub e}{sup −1}} at r/a = 0.6 in L-mode plasmas; rotation was also varied by changing the momentum input from neutral beam injection. Temperature fluctuations were measured with a correlation electron cyclotron emission (CECE) radiometry system. In addition to the CECE measurements, an array of turbulence measurements were acquired to characterize fluctuations in multiple fields and at multiple scales as L{sub T{sub e}{sup −1}} and rotation were modified: long wavelength (k{sub θ}ρ{sub s}≲0.5) density fluctuations were acquired with beam emission spectroscopy, the phase angle between electron temperature and density fluctuations was measured by coupling the CECE system and a reflectometer, intermediate scale (k{sub θ}ρ{sub s}∼0.8) density fluctuations were measured with a Doppler backscattering (DBS) system, and low frequency flows were also measured with DBS. The accumulated measurements and trends constrain identification of the instability responsible for the observed critical gradient to the ∇T{sub e}-driven trapped electron mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High temperature blackbody BB2000/40 for calibration of radiation thermometers and thermocouple

The cavity-type high temperature blackbody (HTBB) models of BB3200/3500 series are the most spread among metrological institutes worldwide as sources for radiometry and radiation thermometry, due to their ultra high working temperatures, high emissivity and stability. The materials of radiating cavities are graphite, pyrolytic graphite (PG) and their combination. The paper describes BB2000/40 blackbody with graphite-tube cavity that was developed for calibration of radiation thermometers at SCEI (Singapore). The peculiarity of BB2000/40 is a possibility to use it, besides calibration of pyrometers, as an instrument for thermocouples calibration. Operating within the temperature range from 900 °C to 2000 °C, the blackbody has a wide cavity opening of 40 mm. Emissivity of the cavity, with PG heater rings replaced partly by graphite elements, was estimated as 0.998 ± 0.0015 in the spectral range from 350 nm to 2000 nm. The uniformity along the cavity axis, accounting for 10 °C, was measured using a B-type thermocouple at 1500 °C. The BB2000/40, if necessary, can be easily modified, by replacing the graphite radiator with a set of PG rings, to be able to reach temperatures as high as 3200 °C. The HTBB utilizes an optical feedback system which allows temperature stabilization within 0.1 °C. This rear-view feedback allows the whole HTBB aperture to be used for measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗