Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radioactive decays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

High-Sensitivity Nuclear-Structure Studies of Rare Isotopes and Few-Electron Systems

This final technical report presents the work that was completed during the award period for DE-SC0017649 related to the structure of nuclei for both astrophysics and tests of the Standard Model, namely: Using trapped bare (and few-electron) radioactive ions to probe the nature of elec- troweak decay modes under extreme conditions for structure and astrophysics, Providing experimental nuclear structure guidance to nuclear theory in systems relevant for testing the Standard Model, and Working with the HPGe sub-group of the FRIB decay station collaboration, which includes the technical development of a next-generation γ-ray spectrometer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microstructural Effects of High Dose Helium Implantation in ErD 2

Metal hydrides can store hydrogen isotopes with high volumetric density. In metal tritides, tritium beta decay can result in accumulation of helium within the solid, in some cases exceeding 10 at.% helium after only 4 years of aging. Helium is insoluble in most materials, but often does not readily escape, and instead coalesces to form nanoscale bubbles when helium concentrations are near 1 at.%. Blistering or spallation often occurs at higher concentrations. Radioactive particles shed during this process present a potential safety hazard. This study investigates the effects of high helium concentrations on erbium deuteride (ErD 2 ), a non-radioactive surrogate material for erbium tritide (ErT 2 ). To simulate tritium decay in the surrogate, high doses of 120 keV helium ions were implanted into ErD 2 films at room temperature. Scanning and transmission electron microscopy indicated spherical helium bubble formation at a critical concentration of 1.5 at.% and bubble linkage leading to nanoscale crack formation at a concentration of 7.5 at.%. Additionally, crack propagation occurred through the nanocrack region, resulting in spallation extending from the implantation peak to the surface. Electron energy loss spectroscopy was utilized to confirm the presence of high-pressure helium in the nanocracks, suggesting that helium gas plays a predominant role in deformation. This work improves the overall understanding of helium behavior in ErD 2 by using modern characterization techniques to determine: the critical helium concentration required for bubble formation, the material failure mechanism at high concentration, and the nanoscale mechanisms responsible for material failure in helium implanted ErD 2 .

36 MATERIALS SCIENCE↗

The LSU-Argonne conversion electron spectrometer: A new detector for the X-Array and SATURN decay station

In this study, a new conversion electron detector has been commissioned at the ATLAS/ CARIBU facility at Argonne National Laboratory. The LSU-Argonne Conversion Electron Spectrometer (LACES) is a LN 2 -cooled Si(Li) detector system designed to be incorporated into a decay station that comprises the dedicated HPGe clover array with a box geometry (X -Array) and the Scintillator and Tape Using Radioactive Nuclei (SATURN) device. This integration enables simultaneous measurements of conversion electrons and gamma-rays in decay experiments, yielding novel information on transition multipolarities, electric monopole transitions, and isomeric states that decay mostly via conversion electrons. A measurement of the energy resolution of LACES yielded 2.3-keV FWHM at 975 keV for electrons and 1.3-keV FWHM at 75 keV for X-rays. A detailed study of the absolute detection efficiency (at 5 mm from the source) was performed, where this quantity was determined experimentally in the range of electron transition energies between 25.5 keV and 1047.8 keV and subsequently simulated using the GEANT4 code. Measurement and simulations are found to be in excellent agreement. A precise characterization, for this type of detector system, of the absolute detection efficiency for such a wide energy range is reported for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring isospin symmetry breaking in exotic nuclei: High-precision mass measurement of 23 Si and shell-model calculations of 𝑇 = 5/2 nuclei

Here, we present a high-precision mass measurement of the proton-rich nucleus 23 Si, performed with the LEBIT Penning trap at the Facility for Rare Isotope Beams (FRIB) utilizing the time-of-flight ion cyclotron resonance (TOF-ICR) technique. We determined a mass excess of 23362.9(5.8) keV, which agrees with a recent storage-ring measurement from the experimental Cooler-Storage Ring (CSRe) in Lanzhou but has a factor of 20 improved precision 23 Si is hence the nucleus with the most precisely known mass among all nuclei with an isospin projection of 𝑇 𝑧 = −5/2. We performed shell-model calculations with the USDC and USDCm Hamiltonians to study binding energy differences and Thomas-Ehrmann shifts in mirror systems with an isospin up to 𝑇 = 5/2. Our experimental result and other recently reported masses of neutron-deficient sd-shell nuclei agree well with the theoretical predictions, demonstrating that isospin symmetry breaking in sd-shell nuclei—even at high isospin values—is well described by modern shell-model calculations.

20 ≤ A ≤ 38↗

$β$-delayed neutron emission studies of 137,138 I and 144,145 Cs performed with trapped ions

A detailed study of the β-delayed neutron emission properties of 137,138 I and 144,145 Cs has been performed by confining ions in the Beta-decay Paul Trap. The daughter ions following β decay emerge from the trapped-ion cloud with negligible scattering allowing reconstruction of the recoil-ion energy from the time of flight. From this information, the neutron-emission branching ratios and neutron-energy spectra were deduced. The results for the 137 I and 144,145 Cs decays are in agreement with previous results performed using direct neutron-detection techniques. In the case of 138 I, a branching ratio of 6.18(50)% is obtained, yielding a value consistent with the more recent results, which are a factor of two larger than measurements made prior to 1978.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two-proton decay from α-cluster states in 10 C and 11 N

Two-proton decay from excited states in 10 C and 11 N has been characterized from an analysis of the 2p + 2α and 3p + 2α exit channels. Data from four previously published invariant-mass studies associated with inelastic excitation, multinucleon knockout, and neutron pickup reactions have been considered. A rotational band in 10 C was identified built on the second 0 + state which has strong α-cluster molecular structure. The members of this band were tentatively identified up to J π = 4 + and all identified states have a prompt 2p decay branch. The spins of the 0 + and 2 + members were deduced from comparisons of the momentum correlations in their 2p branches to those from known 2p emitters. The 2 + and the tentative 4 + members are both above the α threshold and exhibit large reduced decay widths for α emission. This band exhibits a similar moment of inertia to its analog in the mirror nucleus 10 Be. Evidence is also presented for a molecular band in 11 N built on the second 3/2 – state which 2p decays. Furthermore, tentative members of this band have been assigned up to J π = 9/2 – and their excitation energies also match their likely analogs in the mirror nucleus 11 Be.

6 ≤ A ≤ 19↗

High-precision mass measurement of 103 Sn restores smoothness of the mass surface

As a step towards the ultimate goal of a high-precision mass measurement of doubly magic 100 Sn, the mass of 103 Sn was measured at the Low Energy Beam and Ion Trap (LEBIT) located at the Facility for Rare Isotope Beams (FRIB). Utilizing the time-of-flight ion cyclotron resonance technique, a mass uncertainty of 3.7 keV was achieved, an improvement by more than an order of magnitude compared to a recent measurement performed in 2023 at the Cooler Storage Ring (CSRe) in Lanzhou. Although the LEBIT and CSRe mass measurements of 103 Sn are in agreement, they diverge from the experimental mass value reported in the 2016 version of the Atomic Mass Evaluation (AME2016), which was derived from the measured 𝑄 𝛽 + value and the mass of 103 In. In AME2020, this indirectly measured 103 Sn mass was classified as a “seriously irregular mass” and replaced with an extrapolated value, which aligns with the most recent measured values from CSRe and LEBIT. As such, the smoothness of the mass surface is confidently reestablished for 103 Sn. Here, LEBIT's mass measurement of 103 Sn enabled a significant reduction in the mass uncertainties of five parent isotopes which are now dominated by uncertainties in their respective 𝑄 values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced sensitivity to trace 238 U impurity of sapphire via coincidence neutron activation analysis

Sapphire has mechanical and electrical properties that are advantageous for the construction of internal components of radiation detectors such as time projection chambers and bolometers. However, it has proved difficult to assess its 232 Th and 238 U content down to the picogram per gram level. Here, this work reports an experimental verification of a computational study that demonstrates 𝛾⁢𝛾 coincidence counting, coupled with neutron activation analysis (NAA), can reach ppt sensitivities. Combining results from 𝛾⁢𝛾 coincidence counting with those of earlier single-𝛾 counting based NAA shows that a sample of Saint Gobain sapphire has 232 Th and 238 U concentrations of <0.26 ppt and <2.3 ppt, respectively; the best constraints on the radiopurity of sapphire.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the Age of Cosmic Rays as Derived from the Abundance of Be-10

The isotopic composition of cosmic ray Be, B, C, and N was studied using a new range versus total light technique. Special emphasis was placed on the Be isotopes and in particular, on the radioactive isotope Be-10 due to its mean lifetime against decay. The experiment consisted of a thin trigger scintillator, an acrylic plastic Cerenkov detector and a spark chamber, followed by a totally active stack of 14 scintillation detectors. This stack of scintillators made possible the measurement of range, and also permitted the removal of interacting events by continuously monitoring their identities along their trajectories. The experiment was carried by balloon to atmospheric depths ranging from 3.5 to 5.0 g sq cm residual atmosphere for a total exposure time of 23 hr. Results indicate the survival of ( 55 + or -21) % of the Be-10 in the arriving cosmic rays; the data were interpreted using the leaky box model of cosmic ray propagation.

Hagen, F. A.↗

Precision measurement of 65 Zn electron-capture decays with the KDK coincidence setup

65 Zn is a common calibration source, moreover used as a radioactive tracer in medical and biological studies. In many cases, γ-spectroscopy is a preferred method of 65 Zn standardization, which relies directly on the branching ratio of Jπ( 65 Zn) = 5/2- → Jπ( 65 Cu) = 5/2 - via electron capture (EC*). We measure the relative intensity of this branch to that proceeding directly to the ground state (EC 0 ) using a novel coincidence technique, finding I EC 0/IEC* = 0.9684 ± 0.0018. Re-evaluating the decay scheme of 65 Zn by adopting the commonly evaluated branching ratio of I β+ = 1.4271(7)% we obtain IEC* = (50.08 ± 0.06)%, and I EC 0 = (48.50 ± 0.06)%. The associated 1115 keV gamma intensity agrees with the previously reported NNDC value, and is now accessible with a factor of ~2 increase in precision. Our re-evaluation removes reliance on the deduction of this gamma intensity from numerous measurements, some of which disagree and depend directly on total activity determination. The KDK experimental technique provides a new avenue for verification or updates to the decay scheme of 65 Zn, and is applicable to other isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A method for estimating light quenching in inorganic scintillator detectors for radioactive ion beam experiments

In recent experiments, inorganic scintillators have been used to study the decays of exotic nuclei, providing an alternative to silicon detectors and enabling measurements that were previously impossible. However, proper use of these materials requires us to understand and quantify the scintillation process, specifically in response to very heavy nuclei. Here, in this work, we show a simplified method based on the models of Birks (1951) and Meyer and Murray (1962) to parametrize the light output of inorganic scintillators in response to beams of energetic heavy ions over a broad range of energies. We test the accuracy of our parametrization approach by calculating light output and quenching factors for various ions and comparing them with experimental data from Lutetium Yttrium Orthosilicate (LYSO:Ce), a common inorganic scintillator. The Meyer–Murray model suggests that, for sufficiently heavy ions at high energies, the majority of the light output is associated with the creation of delta electrons, which are induced by the passage of the beam through the material. These delta electrons dramatically impact the response of detection systems when subject to ions with velocities typical of beams in modern fragmentation facilities. To illustrate this, we also present a qualitative estimate of the effects of delta rays on overall light output using the Birks–Meyer–Murray parametrization. The approach presented herein will serve as a basic framework for further, more rigorous studies of scintillator response to heavy ions. This work is a crucial first step in planning future experiments where energetic exotic nuclei are interacting with scintillator detectors.

Heavy ion↗

Construction of St. Benedict

The Superallowed Transition Beta-Neutrino Decay Ion Coincidence Trap (St. Benedict) is currently under construction at the University of Notre Dame Nuclear Science Laboratory. It is designed to measure the beta-neutrino angular correlation parameter in superallowed mixed beta-decay transitions between mirror nuclei in order to extract the Fermi-to-Gamow Teller mixing ratio and test theoretical corrections entering in the determination of the V ud element of the Cabibbo–Kobayashi–Maskawa quark mixing matrix. St. Benedict includes a large volume gas catcher to thermalize the radioactive ion beam from TwinSol, a differentially-pumped extraction system, a radiofrequency quadrupole ion cooler and buncher, and a Paul trap for the observation and detection of the β decay products. Finally, the status of each of these components will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signatures of muonic activation in the Majorana Demonstrator

Experiments searching for very rare processes such as neutrinoless double-beta decay require a detailed understanding of all sources of background. Signals from radioactive impurities present in construction and detector materials can be suppressed using a number of well-understood techniques. Background from in situ cosmogenic interactions can be reduced by siting an experiment deep underground. However, the next generation of such experiments have unprecedented sensitivity goals of 10 28 years half-life with background rates of 10 -5 cts/(keV kg yr) in the region of interest. To achieve these goals, the remaining cosmogenic background must be well understood. In the work presented here, Majorana Demonstrator data are used to search for decay signatures of metastable germanium isotopes. Contributions to the region of interest in energy and time are estimated using simulations and compared to Demonstrator data. Correlated time-delayed signals are used to identify decay signatures of isotopes produced in the germanium detectors. A good agreement between expected and measured rate is found and different simulation frameworks are used to estimate the uncertainties of the predictions. The simulation campaign is then extended to characterize the background for the LEGEND experiment, a proposed tonne-scale effort searching for neutrinoless double-beta decay in 76 Ge .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Expected sensitivity to 128 Te neutrinoless double beta decay with the CUORE TeO 2 cryogenic bolometers

The CUORE experiment is a ton-scale array of TeO 2 cryogenic bolometers located at the underground Laboratori Nazionali del Gran Sasso of Istituto Nazionale di Fisica Nucleare (INFN), in Italy. The CUORE detector consists of 988 crystals operated as source and detector at a base temperature of ~ 10 mK. Such cryogenic temperature is reached and maintained by means of a custom built cryogen-free dilution cryostat, designed with the aim of minimizing the vibrational noise and the environmental radioactivity. The primary goal of CUORE is the search for neutrinoless double beta decay of 130 Te , but thanks to its large target mass and ultra-low background it is suitable for the study of other rare processes as well, such as the neutrinoless double beta decay of 128 Te. This tellurium isotope is an attractive candidate for the search of this process, due to its high natural isotopic abundance of 31.75%. The transition energy at (866.7 ± 0.7) keV lies in a highly populated region of the energy spectrum, dominated by the contribution of the two-neutrino double beta decay of 130 Te. As the first ton-scale infrastructure operating cryogenic TeO 2 bolometers in stable conditions, CUORE is able to achieve a factor > 10 higher sensitivity to the neutrinoless double beta decay of this isotope with respect to past direct experiments.

128-Te↗

Plasma instabilities dominate radioactive transients magnetic fields: the self-confinement of leptons in Type Ia and core-collapse supernovae, and kilonovae

The light curves of radioactive transients, such as supernovae and kilonovae, are powered by the decay of radioisotopes, which release high-energy leptons through $\beta ^+$ and $\beta ^-$ decays. These leptons deposit energy into the expanding ejecta. As the ejecta density decreases during expansion, the plasma becomes collisionless, with particle motion governed by electromagnetic forces. In such environments, strong or turbulent magnetic fields are thought to confine particles, though the origin of these fields and the confinement mechanism have remained unclear. Using fully kinetic particle-in-cell (PIC) simulations, we demonstrate that plasma instabilities can naturally confine high-energy leptons. These leptons generate magnetic fields through plasma streaming instabilities, even in the absence of pre-existing fields. The self-generated magnetic fields slow lepton diffusion, enabling confinement, and transferring energy to thermal electrons and ions. Our results naturally explain the positron trapping inferred from late-time observations of thermonuclear and core-collapse supernovae. Furthermore, they suggest potential implications for electron dynamics in the ejecta of kilonovae. We also estimate synchrotron radio luminosities from positrons for Type Ia supernovae and find that such emission could only be detectable with next-generation radio observatories from a Galactic or local-group supernova in an environment without any circumstellar material.

instabilities↗

Clues in the rare gas isotopes to early solar system history

The results of the radioactive dating and the discovery of gas-rich meteorites on the Moon surface are reviewed. Special attention is paid to the extinct radioactivity iodine-129. This radioactivity is produced by r-process of nucleosynthesis and it decays with a half-life of 17 m.y. It provides a clock sensitive to small changes in the early years of the solar system.

Reynolds, J. H.↗

Co/Ni Ratio Between Is Approximately 0.35 - 8.0 GeV/nucleon from the TIGER-2001 Flight

The Trans-Iron Galactic Element Recorder (TIGER) was launched in December 2001 and 2003 from McMurdo, Antarctica and was designed to observe elements ranging from 14 < Z < 40 over an extended energy range. Observations of radioactive isotopes produced during explosive nucleosynthesis such as Ni-59 that decay only through electron capture provide important constraints on the delay between nucleosynthesis and the acceleration of galactic cosmic rays (GCRs). The isotopes of Co and Ni at low energies, in particular, the observations of the Ni-59 and Co-59 from the Cosmic Ray Isotope Spectrometer (CRIS) on the Advanced Composition Explorer, indicate a significant time delay (greater than 7.6 x 10^4 yr) between GCR nucleosynthesis and acceleration. While TIGER is not able to resolve isotopes, observations of the elemental abundances of Co and Ni at high energies further constrain models for the acceleration and propagation of GCRs. The 2001 & 2003 flights of TIGER lasted a total of approx. 50 days and collected sufficient statistics to study the Co/Ni elemental ratio over a wide range in energies. We present the elemental ratio of Co/Ni in galactic cosmic rays between approx. 0.8- 5.0 GeV/nucleon and compare these results with previous measurements and models for cosmic-ray propagation.

deNolfo, G. A.↗

Long-lived isomeric states and quasiparticle band structures in neutron-rich 162,164 Gd nuclei from β decay

Neutron-rich nuclei 162,164 Eu were produced by bombarding a proton beam on a 238 U target at the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory and mass separating the 162,164 Eu products. New level schemes and new γ-ray transitions of the daughters 162,164 Gd were identified from β-decay spectroscopy studies. Additionally, half-lives of the 162,164 Eu were remeasured to clarify the previous ambiguous results. Two quasiparticle band structures were built and compared with neighboring nuclei. The β and γ bands were extended in 162 Gd and a γ band was extended in 164 Gd. Half-lives of the isomeric states at (6 - ) 1449 keV in 162 Gd and (4 - ) 1096 keV in 164 Gd were measured to be 99(3) μs and 0.56(3) μs, respectively. Projected shell model calculations were performed and found to be in good agreement with all of the experimental data.

150 ≤ A ≤ 189↗