Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Simulating Large PEPs Tensor Networks on Small Quantum Devices

We systematically map low bond dimension PEPs tensor networks to quantum circuits. By measuring and reusing qubits, we are in principle able to simulate an N×M square lattice PEPs network (for arbitrary M) of bond dimension 2 using N+ 2 qubits. We then seek to determine if this mapping can yield useful values for long-range loop observables in the presence of quantum device noise in the topological Wen plaquette model by mapping a 3×3 PEPs tensor network to a 5-qubit quantum circuit and executing it on the Honeywell System Model H1-1 trapped-ion device. We find that, for this system size, the noisy observable values are indeed sufficient for diagnosing topological vs. trivial order as the Wen model is perturbed by a magnetic field term in the Hamiltonian. We provide an overview of the experimental procedure and its results. We then explain in greater detail our method for mapping 2D tensor networks to quantum circuits and its scaling properties. This serves as a proof-of-concept of the utilty of the measure-and-reuse approach for simulating large 2D quantum systems on small quantum devices.

MacCormack, Ian↗

Flux-pumped impedance-engineered broadband Josephson parametric amplifier

Broadband quantum-limited amplifiers play a critical role in the single-shot readout of superconducting qubits, but a popular implementation, the traveling wave parametric amplifier, involves a complex design and fabrication process. Here, we present a simple design for a Josephson parametric amplifier, using a lumped element resonator comprising a superconducting quantum interference device whose useful bandwidth is enhanced with an on-chip impedance-matching circuit. Additionally, we demonstrate a flux-coupling geometry that maximizes the coupling to the Josepson loop and minimizes spurious excitation of the amplifier resonant circuit. The amplifier, which operates in a flux-pumped mode, is demonstrated with a power gain of more than 20dB over a bandwidth of about 300MHz, where approximate noise measurements indicate quantum-limited pehrformance. A procedure is given for optimizing the bandwidth for this kind of amplifier, using a linearized circuit simulation while minimizing non-linearities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hybrid Quantum-Classical Eigensolver without Variation or Parametric Gates

The use of near-term quantum devices that lack quantum error correction, for addressing quantum chemistry and physics problems, requires hybrid quantum-classical algorithms and techniques. Here, we present a process for obtaining the eigenenergy spectrum of electronic quantum systems. This is achieved by projecting the Hamiltonian of a quantum system onto a limited effective Hilbert space specified by a set of computational bases. From this projection, an effective Hamiltonian is obtained. Furthermore, a process for preparing short depth quantum circuits to measure the corresponding diagonal and off-diagonal terms of the effective Hamiltonian is given, whereby quantum entanglement and ancilla qubits are used. The effective Hamiltonian is then diagonalized on a classical computer using numerical algorithms to obtain the eigenvalues. The use case of this approach is demonstrated for ground state and excited states of BeH2 and LiH molecules, and the density of states, which agrees well with exact solutions. Additionally, hardware demonstration is presented using IBM quantum devices for H2 molecule.

Jouzdani, Pejman (ORCID:0000000256470381)↗

Workshop on Squeezed States and Uncertainty Relations

The proceedings from the workshop are presented, and the focus was on the application of squeezed states. There are many who say that the potential for industrial applications is enormous, as the history of the conventional laser suggests. All those who worked so hard to produce squeezed states of light are continuing their efforts to construct more efficient squeezed-state lasers. Quite naturally, they are looking for new experiments using these lasers. The physical basis of squeezed states is the uncertainty relation in Fock space, which is also the basis for the creation and annihilation of particles in quantum field theory. Indeed, squeezed states provide a unique opportunity for field theoreticians to develop a measurement theory for quantum field theory.

Han, Daesoo↗

Characterization and Absolute QE Measurements of Delta-Doped N-Channel and P-Channel CCDs

In this paper we present the methodology for making absolute quantum efficiency (QE) measurements from the vacuum ultraviolet (VUV) through the near infrared (NIR) on delta-doped silicon CCDs. Delta-doped detectors provide an excellent platform to validate measurements through the VUV due to their enhanced UV response. The requirements for measuring QE through the VUV are more strenuous than measurements in the near UV and necessitate, among other things, the use of a vacuum monochromator, and good camera vacuum to prevent chip condensation, and more stringent handling requirements. The system used for these measurements was originally designed for deep UV characterization of CCDs for the WF/PC instrument on Hubble and later for Cassini CCDs.

Jacquot, Blake C.↗

In-situ mid-circuit qubit measurement and reset in a single-species trapped-ion quantum computing system

We implement in-situ mid-circuit measurement and reset (MCMR) operations on a trapped-ion quantum computing system by using metastable qubit states in $^{171}\textrm{Yb}^+$ ions. We introduce and compare two methods for isolating data qubits from measured qubits: one shelves the data qubit into the metastable state and the other drives the measured qubit to the metastable state without disturbing the other qubits. We experimentally demonstrate both methods on a crystal of two $^{171}\textrm{Yb}^+$ ions using both the $S_{1/2}$ ground state hyperfine clock qubit and the $S_{1/2}$-$D_{3/2}$ optical qubit. These MCMR methods result in errors on the data qubit of about $2\%$ without degrading the measurement fidelity. With straightforward reductions in laser noise, these errors can be suppressed to less than $0.1\%$. The demonstrated method allows MCMR to be performed in a single-species ion chain without shuttling or additional qubit-addressing optics, greatly simplifying the architecture.

Atomic Physics (physics.atom-ph)↗

Experimental entropic uncertainty relations in dimensions three to five

We provide experimental validation of tight entropic uncertainty relations for the Shannon entropies of observables with mutually unbiased eigenstates in high dimensions. In particular, we address the cases of dimensions 𝑑 = 3, 4, and 5 and consider from 2 to 𝑑 + 1 mutually unbiased bases. The experiment is based on pulsed frequency bins measured with a multioutput quantum pulse gate, which can perform projective measurements on a complete high-dimensional basis in the time-frequency domain. Our results fit the theoretical predictions: the bound on the sum of the entropies is never violated and is saturated by the states that minimize the uncertainty relations.

Serino, Laura [Paderborn University (Germany)] (OR↗

High density Schottky barrier IRCCD sensors for SWIR applications at intermediate temperature

Monolithic 32 x 64 and 64 x 1:128 palladium silicide (Pd2Si) interline transfer infrared charge coupled devices (IRCCDs) sensitive in the 1 to 3.5 micron spectral band were developed. This silicon imager exhibits a low response nonuniformity of typically 0.2 to 1.6% rms, and was operated in the temperature range between 40 to 140 K. Spectral response measurements of test Pd2Si p-type Si devices yield quantum efficiencies of 7.9% at 1.25 microns, 5.6% at 1.65 microns 2.2% at 2.22 microns. Improvement in quantum efficiency is expected by optimizing the different structural parameters of the Pd2Si detectors. The spectral response of the Pd2Si detectors fit a modified Fowler emission model. The measured photo-electric barrier height for the Pd2Si detectors is 0.34 eV and the measured quantum efficiency coefficient, C1, is 19%/eV. The dark current level of Pd2Si Schottky barrier focal plane arrays (FPAs) is sufficiently low to enable operation at intermediate temperatures at TV frame rates. Typical dark current level measured at 120 K on the FPA is 2 nA/sq cm. The operating temperature of the Pd2Si FPA is compatible with passive cooler performance. In addition, high density Pd2Si Schottky barrier FPAs are manufactured with high yield and therefore represent an economical approach to short wavelength IR imaging. A Pd2Si Schottky barrier image sensor for push-broom multispectral imaging in the 1.25, 1.65, and 2.22 micron bands is being studied. The sensor will have two line arrays (dual band capability) of 512 detectors each, with 30 micron center-to-center detector spacing. The device will be suitable for chip-to-chip abutment, thus providing the capability to produce large, multiple chip focal planes with contiguous, in-line sensors.

Elabd, H.↗

Extreme ultraviolet quantum detection efficiency of rubidium bromide opaque photocathodes

Measurements are presented of the quantum detection efficiency (QDE) of three samples of RbBr photocathode layers over the 44-150-A wavelength range. The QDE of RbBr-coated microchannel plate (MCP) was measured using a back-to-back Z-stack MCP configuration in a detector with a wedge and strip position-sensitive anode, of the type described by Siegmund et al. (1984). To assess the stability of RbBr layer, the RbBr photocathode was exposed to air at about 30 percent humidity for 20 hr. It was found that the QDE values for the aged cathode were within the QDE measurement errors of the original values. A simple QDE model was developed, and it was found that its predictions are in accord with the QDE measurements.

Siegmund, Oswald H. W.↗

QuantumNAT: quantum noise-aware training with noise injection, quantization and normalization

Parameterized Quantum Circuits (PQC) are promising towards quantum advantage on near-term quantum hardware. However, due to the large quantum noises (errors), the performance of PQC models has a severe degradation on real quantum devices. Take Quantum Neural Network (QNN) as an example, the accuracy gap between noise-free simulation and noisy results on IBMQ-Yorktown for MNIST-4 classification is over 60%. Existing noise mitigation methods are general ones without leveraging unique characteristics of PQC; on the other hand, existing PQC work does not consider noise effect. To this end, we present QuantumNAT, a PQC-specific framework to perform noise-aware optimizations in both training and inference stages to improve robustness. We experimentally observe that the effect of quantum noise to PQC measurement outcome is a linear map from noise-free outcome with a scaling and a shift factor. Motivated by that, we propose post-measurement normalization to mitigate the feature distribution differences between noise-free and noisy scenarios. Furthermore, to improve the robustness against noise, we propose noise injection to the training process by inserting quantum error gates to PQC according to realistic noise models of quantum hardware. Lastly, post-measurement quantization is introduced to quantize the measurement outcomes to discrete values, achieving the denoising effect. Extensive experiments on 8 classification tasks using 6 quantum devices demonstrate that QuantumNAT improves accuracy by up to 43%, and achieves over 94% 2-class, 80% 4-class, and 34% 10-class classification accuracy measured on real quantum computers. The code for construction and noise-aware training of PQC is available in the TorchQuantum library.

Wang, Hanrui↗

Bilinear dynamic mode decomposition for quantum control

Abstract Data-driven methods for establishing quantum optimal control (QOC) using time-dependent control pulses tailored to specific quantum dynamical systems and desired control objectives are critical for many emerging quantum technologies. We develop a data-driven regression procedure, bilinear dynamic mode decomposition (biDMD), that leverages time-series measurements to establish quantum system identification for QOC. The biDMD optimization framework is a physics-informed regression that makes use of the known underlying Hamiltonian structure. Further, the biDMD can be modified to model both fast and slow sampling of control signals, the latter by way of stroboscopic sampling strategies. The biDMD method provides a flexible, interpretable, and adaptive regression framework for real-time, online implementation in quantum systems. Further, the method has strong theoretical connections to Koopman theory, which approximates nonlinear dynamics with linear operators. In comparison with many machine learning paradigms minimal data is needed to construct a biDMD model, and the model is easily updated as new data is collected. We demonstrate the efficacy and performance of the approach on a number of representative quantum systems, showing that it also matches experimental results.

97 MATHEMATICS AND COMPUTING↗

Probing Electronic Coherence between Core-Level Vacancies at Different Atomic Sites

The detailed understanding of electronic coherence in quantum systems requires measurements on the attosecond timescale. Attosecond x-ray pulses enable the study of electronic coherence in core-excited molecular systems. Here we report on the coherent motion of electrons in the 1,1-difluoroethylene ion following ionization of the K shell of the two nonequivalent carbon sites with a subfemtosecond x-ray pulse. Using the angular streaking technique to track the Auger-Meitner decay, we observe temporal modulations of the emission, indicating the electronic coherence of the core-excited ionic states, and extract a 6.5 ± 0.8 fs average lifetime of the core-level vacancies. A quantum-mechanical model is employed to interpret the measurement, and we find the observed temporal modulations are independent of charge density oscillations. This work opens a new regime of coherent electronic motion, beyond charge migration, where electronic coherence manifests in the nonlocal quantum correlation between atomic sites while charge density oscillation is absent. Our results broaden the landscape of electronic coherence in molecular systems. Published by the American Physical Society 2025

Wang, Jun (ORCID:000000031962895X)↗

Constraints on the polarization angle oscillations of the Crab Nebula with the Simons Array and its applications to the search for axionlike particles

Here, we present a search for polarization oscillation of the Crab Nebula, also known as Tau A, at millimeter wavelengths using observations with the Simons Array, the successor experiment to POLARBEAR. We follow up on previous work by POLARBEAR using 90 GHz band data of the 2023 observing season of the Simons Array to evaluate the variability of Tau A’s polarization angle. Tau A is widely used as a polarization angle calibration source in millimeter-wave astronomy, and thus it is necessary to validate the stability. Additionally, an interesting application of the time-resolved polarimetry of Tau A is to search for axionlike particles (ALPs). We do not detect a global signal across the frequencies considered in this analysis and place a median 95% upper bound of polarization oscillation amplitude A < 0.12° over oscillation frequencies from 3.39 yr -1 to 1.50 day -1 . This constrains the ALP-photon coupling at a median 95% upper bound of g aγγ < 3.84 × 10 -12 × (m a /10 -21 eV) in the mass range from 4.4 × 10 -22 to 7.2 × 10 -20 eV, assuming the ALP constitutes all of dark matter, its field is a stochastic Gaussian field, and it is the sole source of Tau A’s polarization angle oscillation. Additionally, we do not detect signal at the frequencies where 2.5σ hints were previously reported by POLARBEAR, but we do not exclude these signals at the 95% confidence level.

Adkins, Tylor [University of California, Berkeley]↗

Determining quantum phase diagrams of topological Kitaev-inspired models on NISQ quantum hardware

Topological protection is employed in fault-tolerant error correction and in developing quantum algorithms with topological qubits. But, topological protection intrinsic to models being simulated , also robustly protects calculations, even on NISQ hardware. We leverage it by simulating Kitaev-inspired models on IBM quantum computers and accurately determining their phase diagrams. This requires constructing conventional quantum circuits for Majorana braiding to prepare the ground states of Kitaev-inspired models. The entanglement entropy is then measured to calculate the quantum phase boundaries. We show how maintaining particle-hole symmetry when sampling through the Brillouin zone is critical to obtaining high accuracy. This work illustrates how topological protection intrinsic to a quantum model can be employed to perform robust calculations on NISQ hardware, when one measures the appropriate protected quantum properties. It opens the door for further simulation of topological quantum models on quantum hardware available today.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methane concentration and isotopic composition measurements with a mid-infrared quantum-cascade laser

A quantum-cascade laser operating at a wavelength of 8.1 micrometers was used for high-sensitivity absorption spectroscopy of methane (CH4). The laser frequency was continuously scanned with current over more than 3 cm-1, and absorption spectra of the CH4 nu 4 P branch were recorded. The measured laser linewidth was 50 MHz. A CH4 concentration of 15.6 parts in 10(6) ( ppm) in 50 Torr of air was measured in a 43-cm path length with +/- 0.5-ppm accuracy when the signal was averaged over 400 scans. The minimum detectable absorption in such direct absorption measurements is estimated to be 1.1 x 10(-4). The content of 13CH4 and CH3D species in a CH4 sample was determined.

Non-NASA Center↗

Collapsing of spin-split Fermi surfaces in the magnetic Weyl semimetal candidate EuAuSb

EuAuSb is a magnetic Weyl semimetal candidate that exhibits in-plane ferromagnetic ordering and a helical magnetic order across the plane at temperatures below 3.9 K. These magnetic characteristics can drive an interaction-induced reconstruction of the Fermi surface. Here, we report a rare instance of Fermi surface splitting and collapsing driven by exchange coupling, as revealed by strongly temperature-dependent quantum oscillation frequencies in EuAuSb. Shubnikov–de Haas measurements reveal two distinct quantum oscillation frequencies (𝐹 𝛼 = 80 T and 𝐹 𝛽 = 165 T) at 2 K. As the temperature increases toward 40 K, the oscillation peaks at these two frequencies gradually merge into a single peak centered around 128 T. This behavior signifies the collapse of the spin-split Fermi surfaces, driven by the weakening of short-range magnetic correlations and the exchange coupling between conduction electrons and local magnetic moments as temperature increases. Furthermore, our results are further supported by density functional theory calculations, angle-resolved photoemission spectroscopy, and magnetization measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical tuning of the diamond Fermi level measured by correlated scanning probe microscopy and quantum defect spectroscopy

Quantum technologies based on quantum point defects in crystals require control over the defect charge state. Here we tune the charge state of shallow nitrogen-vacancy and silicon-vacancy centers by locally oxidizing a hydrogenated surface with moderate optical excitation and simultaneous spectral monitoring. The loss of conductivity and change in work function due to oxidation are measured in atmosphere using conductive atomic force microscopy and Kelvin probe force microscopy (KPFM). We correlate these scanning probe measurements with optical spectroscopy of the nitrogen-vacancy and silicon-vacancy centers created via implantation 15–25 nm beneath the diamond surface and annealing. The observed charge state of the defects as a function of optical exposure demonstrates that laser oxidation provides a way to precisely tune the Fermi level over a range of at least 2.00 eV. We also observe a significantly larger oxidation rate for implanted surfaces compared to unimplanted surfaces under ambient conditions. Here, combined with knowledge of the electron affinity of a surface, these results suggest KPFM is a powerful, high-spatial-resolution technique to advance surface Fermi level engineering for charge stabilization of quantum defects.

36 MATERIALS SCIENCE↗

Nuclear spin assisted magnetic field angle sensing

Abstract Quantum sensing exploits the strong sensitivity of quantum systems to measure small external signals. The nitrogen-vacancy (NV) center in diamond is one of the most promising platforms for real-world quantum sensing applications, predominantly used as a magnetometer. However, its magnetic field sensitivity vanishes when a bias magnetic field acts perpendicular to the NV axis. Here, we introduce a different sensing strategy assisted by the nitrogen nuclear spin that uses the entanglement between the electron and nuclear spins to restore the magnetic field sensitivity. This, in turn, allows us to detect small changes in the magnetic field angle relative to the NV axis. Furthermore, based on the same underlying principle, we show that the NV coupling strength to magnetic noise, and hence its coherence time, exhibits a strong asymmetric angle dependence. This allows us to uncover the directional properties of the local magnetic environment and to realize maximal decoupling from anisotropic noise.

Physics↗