Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulsing frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Diode-Pumped, Q-Switched, Frequency-Doubling Laser

Experimental Q-switched, diode-pumped, intracavity-frequency-doubling laser generates pulses of radiation at wavelength of 532 nm from excitation at 810 nm. Principal innovative feature distinguishing laser from others of its type: pulsed operation of laser at pulse-repetition frequencies higher than reported previously. Folded resonator keeps most of second-harmonic radiation away from Q-switcher, laser crystal, and laser diodes. Folding mirror highly reflective at fundamental laser wavelength and highly transmissive at second-harmonic laser wavelength. By virtue of difference of about 0.6 percent between reflectivities in two polarizations at fundamental wavelength, folding mirror favors polarized oscillation at fundamental wavelength. This characteristic desirable for doubling of frequency in some intracavity crystals.

Hemmati, Hamid↗

Single-Chip FPGA Azimuth Pre-Filter for SAR

A field-programmable gate array (FPGA) on a single lightweight, low-power integrated-circuit chip has been developed to implement an azimuth pre-filter (AzPF) for a synthetic-aperture radar (SAR) system. The AzPF is needed to enable more efficient use of data-transmission and data-processing resources: In broad terms, the AzPF reduces the volume of SAR data by effectively reducing the azimuth resolution, without loss of range resolution, during times when end users are willing to accept lower azimuth resolution as the price of rapid access to SAR imagery. The data-reduction factor is selectable at a decimation factor, M, of 2, 4, 8, 16, or 32 so that users can trade resolution against processing and transmission delays. In principle, azimuth filtering could be performed in the frequency domain by use of fast-Fourier-transform processors. However, in the AzPF, azimuth filtering is performed in the time domain by use of finite-impulse-response filters. The reason for choosing the time-domain approach over the frequency-domain approach is that the time-domain approach demands less memory and a lower memory-access rate. The AzPF operates on the raw digitized SAR data. The AzPF includes a digital in-phase/quadrature (I/Q) demodulator. In general, an I/Q demodulator effects a complex down-conversion of its input signal followed by low-pass filtering, which eliminates undesired sidebands. In the AzPF case, the I/Q demodulator takes offset video range echo data to the complex baseband domain, ensuring preservation of signal phase through the azimuth pre-filtering process. In general, in an SAR I/Q demodulator, the intermediate frequency (fI) is chosen to be a quarter of the range-sampling frequency and the pulse-repetition frequency (fPR) is chosen to be a multiple of fI. The AzPF also includes a polyphase spatial-domain pre-filter comprising four weighted integrate-and-dump filters with programmable decimation factors and overlapping phases. To prevent aliasing of signals, the bandwidth of the AzPF is made 80 percent of fPR/M. The choice of four as the number of overlapping phases is justified by prior research in which it was shown that a filter of length 4M can effect an acceptable transfer function. The figure depicts prototype hardware comprising the AzPF and ancillary electronic circuits. The hardware was found to satisfy performance requirements in real-time tests at a sampling rate of 100 MHz.

Gudim, Mimi↗

Dual-Pulse Pulse Position Modulation (DPPM) for Deep-Space Optical Communications: Performance and Practicality Analysis

Due to its simplicity and robustness against wavefront distortion, pulse position modulation (PPM) with photon counting detector has been seriously considered for long-haul optical wireless systems. This paper evaluates the dual-pulse case and compares it with the conventional single-pulse case. Analytical expressions for symbol error rate and bit error rate are first derived and numerically evaluated, for the strong, negative-exponential turbulent atmosphere; and bandwidth efficiency and throughput are subsequently assessed. It is shown that, under a set of practical constraints including pulse width and pulse repetition frequency (PRF), dual-pulse PPM enables a better channel utilization and hence a higher throughput than it single-pulse counterpart. This result is new and different from the previous idealistic studies that showed multi-pulse PPM provided no essential information-theoretic gains than single-pulse PPM.

Li, Jing↗

Investigation of pulsed mode operation with the frequency tuned CAPRICE ECRIS

In order to increase the intensity of the highly charged ions produced by the Electron Cyclotron Resonance Ion Sources (ECRISs), techniques like the frequency tuning and the afterglow mode have been developed and in this paper the effect on the ion production is shown for the first time when combining both techniques. Recent experimental results proved that the tuning of the operating frequency of the ECRIS is a promising technique to achieve higher ion currents of higher charge states. On the other hand, it is well known that the afterglow mode of the ECRIS operation can provide more intense pulsed ion beams in comparison with the continuous wave (cw) operation. These two techniques can be combined by pulsing the variable frequency signal driving the traveling wave tube amplifier which provides the high microwave power to the ECRIS. In order to analyze the effect of these two combined techniques on the ion source performance, several experiments were carried out on the pulsed frequency tuned CAPRICE (Compacte source A Plusiers Résonances Ionisantes Cyclotron Electroniques)-type ECRIS. Different waveforms and pulse lengths have been investigated under different settings of the ion source. The results of the pulsed mode have been compared with those of cw operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recombination in liquid-filled ionization chambers beyond the Boag limit

Purpose: The high mass density and low mobilities of charge carriers can cause important recombination in liquid-filled ionization chambers (LICs). Saturation correction methods have been proposed for LICs. Correction methods for pulsed irradiation are based on Boag equation. However, Boag equation assumes that the charge ionized by one pulse is fully collected before the arrival of the next pulse. This condition does not hold in many clinical beams where the pulse repetition period may be shorter than the charge collection time, causing overlapping between charge carriers ionized by different pulses, and Boag equation is not applicable there. In this work, the authors present an experimental and numerical characterization of collection efficiencies in LICs beyond the Boag limit, with overlapping between charge carriers ionized by different pulses. Methods: The authors have studied recombination in a LIC array for different dose-per-pulse, pulse repetition frequency, and polarization voltage values. Measurements were performed in a Truebeam Linac using FF and FFF modalities. Dose-per-pulse and pulse repetition frequency have been obtained by monitoring the target current with an oscilloscope. Experimental collection efficiencies have been obtained by using a combination of the two-dose-rate method and ratios to the readout of a reference chamber (CC13, IBA). The authors have also used numerical simulation to complement the experimental data. Results: The authors have found that overlap significantly increases recombination in LICs, as expected. However, the functional dependence of collection efficiencies on the dose-per-pulse does not change (a linear dependence has been observed in the near-saturation region for different degrees of overlapping, the same dependence observed in the nonoverlapping scenario). On the other hand, the dependence of collection efficiencies on the polarization voltage changes in the overlapping scenario and does not follow that of Boag equation, the reason being that changing the polarization voltage also affects the charge collection time, thus changing the amount of overlapping. Conclusions: These results have important consequences for saturation correction methods for LICs. On one hand, the two-dose-rate method, which relies on the functional dependence of the collection efficiencies on dose-per-pulse, can also be used in the overlapping situation, provided that the two measurements needed to feed the method are performed at the same pulse repetition frequency (monitor unit rate). This result opens the door to computing collection efficiencies in LICs in many clinical setups where charge overlap in the LIC exists. On the other hand, correction methods based on the voltage-dependence of Boag equation like the three-voltage method or the modified two-voltage method will not work in the overlapping scenario due to the different functional dependence of collection efficiencies on the polarization voltage.

60 APPLIED LIFE SCIENCES↗

Generation of nonlinear currents and low-frequency radiation upon interaction of a laser pulse with a metal

Nonlinear currents slowly varying in time are found in the skin layer of a metal irradiated by short laser pulses. The low-frequency field generated by the nonlinear currents in metal and vacuum is studied. The spectral composition, energy and shape of the low-frequency radiation pulse are described. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high-frequency electron paramagnetic resonance spectrometer for multi-dimensional, multi-frequency, and multi-phase pulsed measurements

We describe instrumentation for a high-frequency electron paramagnetic resonance (EPR) and pulsed electron-electron double resonance (PELDOR) spectroscopy. The instrumentation is operated in the frequency range of 107−120 GHz and 215−240 GHz and in the magnetic field range of 0−12.1 T. The spectrometer consisting of a high-frequency high-power solid-state source, a quasioptical system, a phase-sensitive detection system, a cryogenic-free superconducting magnet, and a {sup 4}He cryostat enables multi-frequency continuous-wave EPR spectroscopy as well as pulsed EPR measurements with a few hundred nanosecond pulses. Here we discuss the details of the design and the pulsed EPR sensitivity of the instrumentation. We also present performance of the instrumentation in unique experiments including PELDOR spectroscopy to probe correlations in an insulating electronic spin system and application of dynamical decoupling techniques to extend spin coherence of electron spins in an insulating solid-state system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COMPARISON OF RADIO-FREQUENCY INTERFERENCE MITIGATION STRATEGIES FOR DISPERSED PULSE DETECTION

Impulsive radio-frequency signals from astronomical sources are dispersed by the frequency-dependent index of refraction of the interstellar media and so appear as chirped signals when they reach Earth. Searches for dispersed impulses have been limited by false detections due to radio-frequency interference (RFI) and, in some cases, artifacts of the instrumentation. Many authors have discussed techniques to excise or mitigate RFI in searches for fast transients, but comparisons between different approaches are lacking. This work develops RFI mitigation techniques for use in searches for dispersed pulses, employing data recorded in a 'Fly's Eye' mode of the Allen Telescope Array as a test case. We gauge the performance of several RFI mitigation techniques by adding dispersed signals to data containing RFI and comparing false alarm rates at the observed signal-to-noise ratios of the added signals. We find that Huber filtering is most effective at removing broadband interferers, while frequency centering is most effective at removing narrow frequency interferers. Neither of these methods is effective over a broad range of interferers. A method that combines Huber filtering and adaptive interference cancelation provides the lowest number of false positives over the interferers considered here. The methods developed here have application to other searches for dispersed pulses in incoherent spectra, especially those involving multiple beam systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Multifrequency Raman amplifiers

In its usual implementation, the Raman amplifier features only one pump carrier frequency. However, pulses with well-separated frequencies can also be Raman amplified while compressed in time. Amplification with frequency-separated pumps is shown to hold even in the highly nonlinear, pump-depletion regime, as derived through a fluid model, and demonstrated via particle-in-cell (PIC) simulations. The resulting efficiency is similar to single-frequency amplifiers, but, due to the beat-wave waveform of both the pump lasers and the amplified seed pulses, these amplifiers feature higher seed intensities with a shorter spike duration. Advantageously, these amplifiers also suffer less noise backscattering, because the total fluence is split between the different spectral components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vela X-1 pulse timing. I - Determination of the neutron star orbit

Analysis and interpretation of observations of the pulsed X-ray emission from Vela X-1 are presented. The interrelated tasks of determining the neutron-star orbit and calculating pulse emission times in the rest frame of the source are considered, with the underlying motivation to utilize this time series for analysis of fluctuations in the pulse emission frequency, which are interpreted as noise in the neutron-star rotation rate. However, the redness and strength of this noise in Vela X-1 pose a nontrivial complication, because the parameters of the neutron-star orbit are estimated by pulse timing and hence are themselves affected by fluctuations in the pulse emission frequency. A second challenge is presented by substantial fluctuations in the Vela X-1 pulse shape that, if ignored, would significantly reduce both the precision of the orbital solution and the ability to study fluctuations in the rotation rate. The report emphasizes the analysis techniques that have been developed to obtain the most precise orbital solution possible in the face of these difficulties. These techniques are general and may be applied to other pulsars that exhibit substantial fluctuations in pulse shape and frequency, such as Her X-1 and Cen X-3.

Boynton, P. E.↗

Parameteric studies of nonlinear oblique magnetosonic waves in two-ion-species plasmas

The study of the effects of ion composition on perpendicular magnetosonic waves in two-ion-species plasmas [M. Toida, H. Higashino, and Y. Ohsawa, J. Phys. Soc. Jpn. 76, 104052 (2007)] is extended to include oblique waves. First, the conditions necessary for KdV equations for low- and high-frequency modes to be valid are analytically obtained. The upper limit of the amplitude of the low-frequency-mode pulse is expressed as a function of the propagation angle {theta}, density ratio, and cyclotron frequency ratio of the two ion species. Next, with electromagnetic particle simulations, the nonlinear evolution of a long-wavelength low-frequency-mode disturbance is examined for various {theta}s in two plasmas with different ion densities and cyclotron frequency ratios, and the theory for the low-frequency-mode pulse is confirmed. It is also shown that if the pulse amplitude exceeds the theoretical value of the upper limit of the amplitude, then shorter-wavelength low- and high-frequency-mode waves are generated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser ablation loading of a surface-electrode ion trap

We demonstrate loading of {sup 88}Sr{sup +} ions by laser ablation into a mm-scale surface-electrode ion trap. The laser used for ablation is a pulsed, frequency-tripled Nd:YAG with pulse energies of 1-10 mJ and durations of 4 ns. An additional laser is not required to photoionize the ablated material. The efficiency and lifetime of several candidate materials for the laser ablation target are characterized by measuring the trapped ion fluorescence signal for a number of consecutive loads. Additionally, laser ablation is used to load traps with a trap depth (40 meV) below where electron impact ionization loading is typically successful (> or approx. 500 meV)

74 ATOMIC AND MOLECULAR PHYSICS↗

The ILC P2 Marx and Application of the Marx Topology to Future Accelerators

The SLAC P2 Marx is under development as the linac klystron modulator for the ILC. This modulator builds upon the success of the P1 Marx, which is currently undergoing lifetime evaluation. While the SLAC P2 Marx's (henceforth, 'P2 Marx') target application is the ILC, characteristics of the Marx topology make it equally well-suited for operation at different parameter ranges; for example, increased pulse repetition frequency, increased output current, longer pulse width, etc. Marx parameters such as the number of cells, cell capacitance, and component selection can be optimized for the application. This paper provides an overview of the P2 Marx development. In addition, the scalability of the Marx topology to other long-pulse parameter ranges is discussed.

43 PARTICLE ACCELERATORS↗

Generation of Microwave Pulses with a Carrier Frequency of 3.8 GHz and a Length of 75 ns by a Relativistic Cherenkov Microwave Oscillator without a Guiding Magnetic Field

In the experiment with an electron energy of ≈500 keV, the long-pulse (~300T, where T is the oscillation period) the generation regime of a relativistic Cherenkov microwave oscillator without a guiding magnetic field at a carrier frequency of 3.8 GHz has been obtained. A high-power microwave radiation pulse length of ~75 ns, a peak generation power of 210 ± 30 MW, and a power conversion efficiency of 9 ± 2% were attained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exponential frequency spectrum and Lorentzian pulses in magnetized plasmas

Two different experiments involving pressure gradients across the confinement magnetic field in a large plasma column are found to exhibit a broadband turbulence that displays an exponential frequency spectrum for frequencies below the ion cyclotron frequency. The exponential feature has been traced to the presence of solitary pulses having a Lorentzian temporal signature. These pulses arise from nonlinear interactions of drift-Alfven waves driven by the pressure gradients. In both experiments the width of the pulses is narrowly distributed resulting in exponential spectra with a single characteristic time scale. The temporal width of the pulses is measured to be a fraction of a period of the drift-Alfven waves. The experiments are performed in the Large Plasma Device (LAPD-U) [W. Gekelman et al., Rev. Sci. Instrum. 62, 2875 (1991)] operated by the Basic Plasma Science Facility at the University of California, Los Angeles. One experiment involves a controlled, pure electron temperature gradient associated with a microscopic (6 mm gradient length) hot electron temperature filament created by the injection a small electron beam embedded in the center of a large, cold magnetized plasma. The other experiment is a macroscopic (3.5 cm gradient length) limiter-edge experiment in which a density gradient is established by inserting a metallic plate at the edge of the nominal plasma column of the LAPD-U. The temperature filament experiment permits a detailed study of the transition from coherent to turbulent behavior and the concomitant change from classical to anomalous transport. In the limiter experiment the turbulence sampled is always fully developed. The similarity of the results in the two experiments strongly suggests a universal feature of pressure-gradient driven turbulence in magnetized plasmas that results in nondiffusive cross-field transport. This may explain previous observations in helical confinement devices, research tokamaks, and arc plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗