pyiron - Rapid-prototyping and Up-scaling Workflows for the Exascale
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A low particulate vacuum and purging system was developed to support PIP-II cryomodule string assembly. The overpressure can be controlled at a precision of 1 mbar above the atmospheric pressure regardless of the cavity or string assembly air volume. The system minimized the risk of uncontrolled nitrogen flow during the string assembly. Design features are presented.
Abstract not provided.
The 60-kilowatt (kW) Zephyr 21/60 wind turbine from Windward Engineering uses a low-cost, full-span independent pitch system that can act as a redundant aerodynamic braking system. This design uses a relatively simple pneumatic rotary vane actuator, allowing each of the turbine's three blades to be pitched independently and any single blade to activate emergency braking for the entire turbine. A previous Competitiveness Improvement Project (CIP) funding award enabled Windward Engineering to design and develop the Zephyr 21/60 wind turbine's aeroelastic model and pitch system. At the end of this current Competitiveness Improvement Project award, a fully validated aeroelastic model will make it possible to certify Windward Engineering's Zephyr 21/60 design and quantify the technology's levelized cost of energy in preparation for certification and entry into the distributed wind market. The Zephyr 21/60 will feature an attractive levelized cost of energy, improved reliability, and a full-span pitch system for safe and redundant protection against rotor overspeed (which occurs when the rotor turns beyond its design limit).
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.
This poster presents a novel modular, scalability receiver design for various Concentrating Solar Thermal (CST)-Concentrating Solar Power (CSP) applications and scale of economics.
Explore the source record for details and available documents.
Light water reactor (LWR) fuel rod cladding picks up hydrogen as it oxidizes in reactor. Once the hydrogen concentration exceeds the solubility limit, zirconium hydride platelets precipitate, generally in the circumferential direction. In preparation for dry storage, elevated temperatures can dissolve some of the circumferential hydrides, which during cooling can then reprecipitate in a direction perpendicular to the hoop stress (radially). From 2019 to 2024, ORNL published a series of reports that included metallographic observations of cladding after a thermal transient to 400°C followed by slow cooling. The simulated dry storage process was performed on three full-length 17x17 PWR fuel rods at their as-discharged rod internal pressure. There were two important observations from the metallographic examinations of these heat-treated rods: (1) the propensity for hydride reorientation is strongly influenced by nearby as-discharged precipitated hydrides, (2) the radial hydrides observed near the cladding inner diameter were often associated with cracks in the pellet. Subsequent modeling using the BISON fuel performance code that considered the effects of pellet cracks and pellet-cladding bonding observed in high-burnup fuel support the conclusion that pellet cracks enhance the local hoop stress in the cladding creating preferential sites for hydride reorientation, and that the influence of the pellet cannot be ignored in accurate fuel rod performance predictions.
Vertical-axis wind turbines offer a compelling path to low-cost, reliable distributed energy that can compete with utility prices for businesses, landowners, and municipalities in rural areas. They generate power by using a main rotor shaft perpendicular to the ground to pick up wind from different directions without a yaw mechanism. However, previous commercialization attempts struggled to account for the unsteady aerodynamics of this design, leading to low power production and/or premature structural failure. To address these challenges, Competitiveness Improvement Project recipient XFlow Energy is building on work completed during three previous CIP funding awards to develop a 30-kW vertical-axis wind turbine that achieves both low costs and high energy output.
Ubiquitous web-based visualization is essential to delivering large-scale data visualization to various stakeholders, from the scientist to the board member. These stakeholders will not tolerate a stalled application or a pop-up window asking them to wait for the processing to complete. They require a responsive and interactive visualization environment with high-quality imagery suitable for detailed analysis and boardroom presentations. At Kitware, Inc., we have accomplished web visualization to this point, leveraging state-of-the-art tools like HTML5, CSS3, SVG, Canvas, and WebGL. Solutions that leverage a combination of these technologies are necessary to handle workloads that vary significantly in data size efficiently. However, it is not always practical to move large data to the web client for visualization. Kitware's ParaView as a Service combines client-side visualization using both distributed processing and remote rendering on big data impractical to move. Existing distributed processing and remote rendering solution's interactivity is below the expectations of web-based applications. Our project examined proposed solutions to the areas outlined above in ParaView as a Service. We have investigated concurrent pipelines, streaming images, progressive rendering, and optimization of algorithms and data movement to address these concerns. For the Phase I project, we completed the proposed work plan. As a result, the project produced three prototypes of essential importance for web visualization and the ParaView as a Service community. We created a simple desktop application for an interactive streamline placement prototype, a web-based interactive streamline placement prototype, and a web-based progressive rendering utilizing raytracing prototype. These prototypes relied on the hardening of emerging software toolkits funded by the Department of Energy (DOE) Advanced Scientific Computing Research (ASCR) program (such as ParaView, VTK-m, and Mochi). We blended these components into web-based visualization prototypes that meet the industry's expectations for interactivity and responsiveness. The Phase I project had four essential focus areas: 1. Develop prototype ParaView as a Service backend server using asynchronous, non-blocking design principles. 2. Develop a prototype web application that uses the ParaView as a Service backend server for remote data visualization. 3. Implement image streaming with encoding/compression and progressive rendering capabilities in the proposed platform. 4. Evaluate the prototype developed and summarize observations, including the challenges and pitfalls of our approach. After our successful completion of Phase I, we are strongly positioned to propose a successful Phase II project.
The design and development of a prototype unmanned mobile floating platform, equipped with a custom low-flow marine current turbine for autonomously seeking and harnessing tidal/coastal currents is described. The platform is an unmanned surface vehicle in the form of a catamaran with two electric outboard motors and capabilities for autonomous navigation. An undershot water wheel, aided by a custom flow concentrator, has been selected as the basic design for the marine current turbine, which is mounted on the stern of the unmanned surface vehicle platform. The concept of operation is that the platform would navigate to a designated marine current resource, autonomously anchor at the location, align itself in the current and deploy the current turbine using a custom cable-lift deployment mechanism. As the turbine harnesses the local current, an onboard power-take-off device converts the harnessed mechanical energy to electricity which is stored in onboard batteries. Considerations of deployment in tidal and coastal waters required obtaining the necessary environmental permits for conducting in-water testing; developing required mitigation measures in protecting local wildlife and their habitats; and identifying potential in-water test sites and surveying them for their suitability in terms of the current resource, bottom type, water depth, and local boat traffic. The design and development of the turbine and the results of initial in-water testing are discussed. The potential for scaling up the system for extended capacity is presented.
Three-dimensional (3-D) Computational Fluid Dynamics (CFD) analysis of a whole nuclear reactor core is a tremendous challenge due to the large geometric volume and complex structures. Here, this research presents a hybrid porous (HP) model to simplify a prismatic High Temperature Gas-cooled Reactor (HTGR) core, so 3-D CFD investigation can be performed on a full reactor core scale. In the HP model, the prototypic small coolant channels in the nuclear fuel blocks are lumped together to form multiple equivalent large coolant channels, and then the porous medium flow model is applied to each of them. Therefore, heat transfer in fuel blocks is computed by a hybrid combination of solid energy and porous flow energy equations. The similarity between the HP model and prototypic model is achieved by deriving the porous flow permeability, inertial resistance factor, and artificial thermophysical properties. Compared with the widely used whole porous (WP) flow model, the HP model preserves more realistic geometric structures, and therefore more accurate physical processes. The General Atomics' Modular High Temperature Gas-cooled Reactor (MHTGR) design was chosen as a prototype to demonstrate the methodology. Simulations were performed using the prototypic CFD model and HP model at steady-state forced circulation, steady-state natural circulation, and transient conditions that correspond to normal operation, extended period of pressurized cool down, and short-term transients after reactor shutdown, respectively. The comparison shows good agreement between the HP model and prototypic model in the maximum fuel temperature, average solid temperature, and helium flow rate, which demonstrates the potential applicability of the HP model for a full reactor core scale simulation in the future. As a benefit, the HP model reduces the mesh quantity by a factor of 50 from a prototypic model. Correspondingly, the computation time was reduced by a factor of at least 30.
GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.